PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) PMF Highlights & Features – Universal AC input voltage – Built-in active PFC and fan speed control – Full corrosion resistant aluminium chassis – Conforms to harmonic current IEC/EN 61000-3-2, Class A and Class D – Cold start -20°C at 100% load (320W) – Remote ON/OFF is available as an option Safety Standards CB Certified for worldwide use Model Number: PMF-24V320WC☐☐ Unit Weight: 0.84 kg Dimensions (L x W x D): 215 x 115 x 50 mm General Description The PMF panel mount power supply series currently offers nominal output voltages of 24V . These power supply units come with universal AC input from 85Vac to 264Vac and wide operating temperature of - 10°C to +70 °C. The built-in active PFC provides high power factor and conforms to harmonic current IEC/EN 61000-3 -2, Class A and Class D. This versatile series has two different connector options (Front Face and Terminal Block) to satisfy different application needs. Remote ON/OFF function is also available for the PMF series. All PMF power supplies conform to major international safety standards including IEC/EN/UL 60950- 1 standards and are fully compliant with RoHS Directive 2011/65/EU for environmental protection. Model Information PMF Panel Mount Power Supply Model Number Input Voltage Range Output Voltage Output Current PMF-24V320WC☐☐ 85-264Vac 24Vdc 13.3A Model Numbering CC Code PM F – 24V 320W C □ □ Panel Mount Product Series F – PFC Series Output Voltage Output Power Package Type C – Enclosed Connector Type G – Front Face A – Terminal Block* Variable B – No Remote ON/OFF R – With Remote ON/OFF* *Options

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) Specifications Input Ratings / Characteristics Nominal Input Voltage 100-240Vac Input Voltage Range 85-264Vac Nominal Input Frequency 50-60Hz Input Frequency Range 47-63Hz Input Current < 5.00A @ 115Vac, < 2.50A @ 230Vac Efficiency at 100% Load 87.0% typ. @ 230Vac Max Inrush Current < 20A @ 115Vac, < 40A @ 230Vac Power Factor 0.98 typ. @ 115Vac, 0.95 typ. @ 230Vac Leakage Current < 1mA @ 240Vac Output Ratings / Characteristics Nominal Output Voltage 24Vdc Output Voltage Tolerance ± 1% (initial set point tolerance from factory) Output Voltage Adjustment Range 21.6-26.4Vdc Output Current 13.3A Output Power 320W Line Regulation ± 0.2% typ. (@ 115Vac & 230Vac) Load Regulation ± 1.0% typ. (@ 115Vac & 230Vac) PARD (20MHz) < 150mVpp @ 25°C < 300mVpp @ -10°C Rise Time 50ms typ. @ 115Vac & 230Vac (100% load) Start-up Time 2500ms typ. @ 115Vac, 800ms typ. @ 230Vac (100% load) Hold-up Time 20ms typ. @ 115Vac & 230Vac Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% (2.4V pk-pk) @ 115Vac & 230Vac (0-100% load) Start-up with Capacitive Loads 8,000µF Max Remote ON/OFF Function (Option) CN102 Output ON: 5-12.5V Output OFF: 0-0.5V (For more information, please refer to the details in the Functional Manual section on Page 10)

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) Mechanical Case Chassis Aluminium Case Cover Aluminium Dimensions (L x W x D) 215 x 115 x 50 mm Unit Weight 0.84 kg Indicator Green LED (DC OK) Cooling System Forced Cooling Terminal PMF-24V320WCG☐ M3.5 x 9 Pins (Rated 300V/20A) PMF-24V320WCA☐ M3.5 x 9 Pins (Rated 300V/15A) Wire AWG 20-12 Environment Surrounding Air Temperature Operating -10°C to +70°C (Cold start at -20°C) Storage -25°C to +85°C Power De-rating > 50°C de-rate power by 2.5% / °C < 100Vac de-rate power by 1.33% / 1V Operating Humidity 5 to 95% RH (Non-Condensing) Operating Altitude 0 to 5,000 Meters Shock Test (Non-Operating) IEC 60068-2-27, Half Sine: 50G for a duration of 11ms, 3 shocks for each 3 directions Vibration (Non-Operating) IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction Pollution Degree 2 Protections Overvoltage 27.6-32.4V, Latch Mode (AC power is recycled) Overload / Overcurrent 105-150%, Hiccup Mode, Non-Latching (Auto-Recovery) Over Temperature Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) Short Circuit Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) Protection Against Shock Class I with PE* connection *PE: Primary Earth Reliability Data MTBF > 700,000 hrs. as per Telcordia SR-332 I/P: 100Vac, O/P: 100% load, Ta: 35°C Expected Cap Life Time 10 years (115Vac & 230Vac, 50% load @ 40°C)

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) Safety Standards / Directives Electrical Safety TUV Bauart to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1, CB scheme to IEC 60950-1, CCC to GB4943 CE In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC Material and Parts RoHS Directive 2011/65/EU Compliant Galvanic Isolation Input to Output 3.0KVac Input to Ground 2.0KVac Output to Ground 0.5KVac EMC EMC / Emissions CISPR 22, EN 55022, FCC Title 47: Class B Immunity to EN 55024 Electrostatic Discharge IEC 61000-4-2 Criteria A1) Level 3 Air Discharge: 8kV Level 2 Contact Discharge: 4kV Radiated Field IEC 61000-4-3 Level 2 Criteria A1) 80MHz-1GHz, 10V/M with 1kHz tone / 80% modulation Electrical Fast Transient / Burst IEC 61000-4-4 Level 3 Criteria A1) 1kV Surge IEC 61000-4-5 Level 3 Criteria A1) Common Mode2): 2kV Differential Mode3): 1kV Conducted IEC 61000-4-6 Level 2 Criteria A1) 150kHz-80MHz, 3Vrms Power Frequency Magnetic Fields IEC 61000-4-8 Criteria A1) 1A/Meter Voltage Dips IEC 61000-4-11 100% dip; 1 cycle (20ms); Self Recoverable Harmonic Current Emission IEC/EN 61000-3-2, Class A and Class D Voltage Fluctuation and Flicker IEC/EN 61000-3-3 1) Criteria A: Normal performance within the specification limits 2) Asymmetrical: Common mode (Line to earth) 3) Symmetrical: Differential mode (Line to line)

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) Block Diagram Device Descriptions 1) Input & Output terminal block connector 2) DC voltage adjustment potentiometer 3) DC OK control LED (Green) 4) Remote ON/OFF function connector (Option) PMF-24V320WCG☐: Front Face PMF-24V320WCA☐: Terminal Block

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) Dimensions L x W x D: 215 x 115 x 50 mm (PMF-24V320WCG☐: Front Face)

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) L x W x D: 215 x 115 x 50 mm (PMF-24V320WCA☐: Terminal Block)

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) Engineering Data De-rating Output De-rating VS. Input Voltage Note 1. Power supply components may degrade, or be damaged, when the power supply is continuously used outside the shaded region, refer to the graph shown in Fig. 1. 2. If the output capacity is not reduced when the surrounding air temperature >50 °C, the device will run into Over Temperature Protection. When activated, the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition. 3. In order for the device to function in the manner intended, it is also necessary to keep a safety distance of 20mm with adjacent units while the device is in operation. 4. Depending on the surrounding air temperature and output load delivered by the power supply, the device can be very hot! 5. If the device has to be mounted in any other orientation, please do not hesitate to contact info@deltapsu.com for more details. Fig. 1 De-rating for Vertical and Horizontal Mounting Orientation > 50°C de-rate power by 2.5% / °C  No output power de -rating for the input voltage from 100Vac to 264Vac

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) Assembly & Installation Ⓐ Side Mounting: Fig. 2 and Fig. 3 show the mounting hole locations for power supply assembly onto a metal mounting surface. The power supply shall be mounted on minimum of 4 mounting holes using M4 screw of maximum 5 mm length (Refer to Fig. 4). This is to maintain a safety distance between the screw and internal components. Ⓑ Base Mounting: Fig. 2 and Fig. 3 show the mounting hole locations for power supply assembly onto a metal mounting surface. The power supply shall be mounted on minimum of 4 mounting holes using M4 screw of maximum 4mm length (Refer to Fig. 4). This is to maintain a safety distance between the screw and internal components. Ⓒ Connector Ⓓ This surface belongs to customer’s end system or panel where the power supply is mounted. Base Mounting (Horizontal) Base Mounting (Vertical) Side Mounting (Horizontal) Fig. 2 Recommended Mounting Orientations – Use flexible cable (stranded or solid) of AWG No. 20-12. The input/output connectors’ allowable current is 23A max per pin. User should calculate and select the suitable wire specification (type/quantity/diameter) according to actual output current. The torque at the connector shall not exceed 13Kgf.cm. The insulation stripping length should not exceed 0.275” or 7mm. – Recommended mounting torque of the product and its mounting accessories is 9~12Kgf.cm. Fig. 4 Assembly Reference  Only use M4 screw ≤ 5mm through the base mounting holes at Ⓐ. This is to keep a safe distance between the screw and internal components.  Only use M4 screws ≤ 4mm through the base mounting holes at Ⓑ. This is to keep a safe distance between the screw and internal components. Fig. 3 Mounting Hole Locations and the Safety Distance Ensure the mounted device is kept at ≥ 4mm safety distance at all sides from other components and equipments. In addition, to ensure sufficient convection cooling, always maintain a distance of ≥ 20mm from ventilated surfaces while the device is in operation. Safety Distance D1 = 4.0mm Min. D2 = 20.0mm Min.

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) Safety Instructions – If user’s mounting orientation is not according to the recommended mounting orientations, please consult Delta for further information. – The device is not recommended to be placed on low thermal conductive surface. For example, plastics. – The enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! – Do not touch the terminals while power is being supplied. Risk of electric shock. – Prevent any foreign metal, particles or conductors from entering the device through the openings during i nstallation. It may cause electric shock, safety hazard, fire and/or product failure. – Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Eart h connection. The power supply must be mounted by metal screws onto a grounded metal surface. It is highly recommended that the Earth terminal on the connector be connected to the grounded metal surface. Accessories LM-01: Top Fixing Bracket This bracket is used to fix the power supply onto a flat surface from the top.

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) Functional Manual Remote ON/OFF Function You can remotely control the power supply unit to turn ON/OFF by using an external DC source. Follow the DC power source voltage and current limiting defined in the table below. Built-in Resistor Ri (ohm) Voltage Between RC+ and RC- (V) Input Current (mA) Output ON Output OFF 820 5-12.5 0-0.5 20 Max Notes 1. Remote ON/OFF circuits are isolated from input, output and PE. 2. Please check if the polarity of the wire connector is the same as the external DC source. If not, the power would not turn on and the internal components may be damaged. 3. You do not need an external resistance R O for current limit while the output voltage of external DC source is within the range of 5-12.5V. If the output voltage exceeds 12.5V, please use the following equation for the value of current limit resistance RO. 𝑅𝑂 = 𝑉𝑐𝑐 −(3.5 + 0.006𝑅𝑖) 0.006

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) Functions Start-up Time The time required for the output voltage to reach 90% of its set value, after the input voltage is applied. Rise Time The time required for the output voltage to change from 10% to 90% of its set value. Hold-up Time Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time required for the output to reach 95% of its set value, after the input voltage is removed. ■ Graph illustrating the Start-up Time, Rise Time, and Hold-up Time Inrush Current Inrush current is the peak, instantaneous, input current measured and, occurs when the input voltage is first applied. For AC input voltages, the maximum peak value of inrush current will occur during the first half cycle of the applied AC voltage. This peak value decreases exponentially during subsequent cycles of AC voltage. Dynamic Response The power supply output voltage will remains within ±5% of its steady state value, when subjected to a dynamic load from 0 to 100% of its rated current.

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) Overload & Overcurrent Protections The power supply’s Overload (OLP) and Overcurrent (OCP) Protections will be activated when output current exceeds 105-150% of I O (Max load). In such occurrence, the V O will start to droop and once the power supply has reached its maximum power limit, the protection is activated and the power supply will go into “Hiccup mode” (Auto- Recovery). The power supply will recover once the fault condition of the OLP and OCP is removed and IO is back within the specifications. It is not recommended to prolong the duration of I O when it is <105% but >100%, since it may cause damage to the PSU. Short Circuit Protection The power supply’s output OLP/OCP function also provides protection against short circuits. When a short circuit is applied, the output current will operate in “Hiccup mode”, as shown in the illustration in the OLP/OCP section on this page. The power supply will return to normal operation after the short circuit is removed. Overvoltage Protection The power supply’s overvoltage circuit will be activated when its internal feedback circuit fails. The output voltage shall not exceed its specifications defined on Page 3 under “Protections”. The power supply should be latch. Over Temperature Protection As mentioned above, the power supply also has Over Temperature Protection (OTP). In the event of a higher operating temperature at 100% load, the power supply will run into OTP when the operating temperature is beyond what is recomme nded in the de-rating graph. When activated, the output voltage will go into bouncing mode until the temperature drops to its normal operating temperature as recommended in the de-rating graph.

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) Operating Mode  Redundancy Operation In order to ensure proper redundancy operation for the power supply unit (PSU), ensure that the output voltage difference bet ween the two units is kept at 0.45~0.50V for 24V supplies. Follow simple steps given below to verify: Step 1. Measure output voltage of PSU 1 and PSU 2. If PSU 1 is the master unit, then V O of PSU 1 must be higher than PSU 2. In order to set the output voltage, connect the power supply to 50% load and set the PSU 1 and PSU 2 output voltage. Step 2. Connect the right DRR module, 4 0A as per the system requirement to the power supply units PSU 1 and PSU 2 at V in 1 & V in 2 respectively. Step 3. Connect the system load from V out. Please note that output voltage V out from DRR module will be = V O (output voltage of power supply) – Vdrop* (in DRR module).  Parallel Operation + 2.5A + 2.5A = 7.5A) or current sharing, and thus increasing the power supply and system reliability. Though the PMF-24V320WC☐☐ is not designed for current sharing, a good current sharing between two power supplies can be achieved by following simple steps as below (Refer to Fig. 5 for the Connection Diagram). drop will vary from 0.60V to 0.90V (Typical 0.65V) depending on the load current and surrounding air temperature. Fig. 5 Redundancy / Parallel Operation Connection Diagram Step 1. Set output load condition for both supplies at 50% and measure the output voltages. Step 2. Adjust output voltages to the same level or within ±25mV difference. Step 3. Connect PSU 1 and PSU 2 with the DRR -40A module and measure at Vin 1 & Vin 2 to verify the voltage difference. Ensure the voltages are within ±25mV. Step 4. Output voltage from DRR module V out will be = V O (output voltage of power supply) – Vdrop* (in DRR module).

PMF Panel Mount Power Supply 24V 320W 1 Phase / PMF-24V320WC□□ All parameters are specified at 25°C ambient unless otherwise indicated. www.DeltaPSU.com (June 2014, Rev. 00) Others Delta RoHS Compliant Restriction of the usage of hazardous substances The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and electronic equipment. RoHS is the abbreviation f or “Restriction of the use of certain hazardous substances in electrical and electronic equipment”. This product conforms to this standard. PFC – Norm EN 61000-3-2 Line Current Harmonic content Typically, the input current waveform is not sinusoidal due to the periodical peak charging of the input capacitor. In industrial environment, complying with EN 61000- 3-2 is only necessary under special conditions. Complying to this standard can have some technical drawbacks, such as lower efficiency as well as some commercial aspects such as higher purchasing costs. Frequently, the user does not profit from fulfilling this standard, therefore, it is important to know whether it is mandatory to meet this st andard for a specific application.