PM2_V01 ETC | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 6
Technical content
SYSTEMS Convergent Reflective Micro Photoelectric Sensor Amplifier Built-in PM2 SERIES Convergent reflection sensing ensures stable detection Conforming to EMC Directive Stable detection by convergent reflective mode Stable detection characteristics are obtained since it is convergent reflective type and senses a limited area. Hardly affected by background Even a specular background does not affect the sensing performance if the sensor is located 30 mm 1.181 in away from it. Detects an object within the convergent area 30 mm 1.181 in Background Sensing object However, the specular background should be a plane surface, directly facing the sensor. A spherical or curved background may be detected. Dark object detectable Since the sensor is very sensitive, it can detect even a dark object of low reflectivity. Optimum setting distance is 5 mm 0.197 in approx. Minute object detectable A ø0.05 mm ø0.002 in copper wire can be detected at a distance of 5 mm 0.197 in under the optimum condition. 5 mm 0.197 in approx. ø0.05 mm ø0.002 in copper wire Cable type is also available Cumbersome soldering is not required. It saves space and improves reliability. PM2 -LH10 PM2 -LH10 Cable type With connector 50 mm 1.969 in approx. 25 mm 0.984 in approx. Certified panasonic.net/id/pidsx/global
Convergent Reflective Micro Photoelectric Sensor PM2 SERIES 454 Selection Guide U-shaped Convergent Reflective PM2 FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS ORDER GUIDE Type Appearance Sensing range Model No. Output Output operation Connector type Top sensing 2.5 to 8 mm 0.098 to 0.315 in (Convergent point: 5 mm 0.197 in) PM2-LH10 NPN open-collector transistor Light-ON PM2-LH10B Dark-ON Front sensing PM2-LF10 Light-ON PM2-LF10B Dark-ON L type (Top sensing) PM2-LL10 Light-ON PM2-LL10B Dark-ON Cable type Top sensing PM2-LH10-C1 Light-ON PM2-LH10B-C1 Dark-ON Front sensing PM2-LF10-C1 Light-ON PM2-LF10B-C1 Dark-ON L type (Top sensing) PM2-LL10-C1 Light-ON PM2-LL10B-C1 Dark-ON
APPLICATIONS
Sensing capacitors in a tray OPTIONS Designation Model No. Description Connector CN-13 Dedicated connector Connector attached cable CN-13-C1 0.2 mm2 3-core cabtyre cable, 1 m 3.281 ft long CN-13-C3 0.2 mm2 3-core cabtyre cable, 3 m 9.843 ft long Connector
- CN-13 Connector attached cable
- CN-13-C1
- CN-13-C3 Positioning and passage confirmation of a printed circuit board
Convergent Reflective Micro Photoelectric Sensor PM2 SERIES Selection Guide U-shaped Convergent Reflective PM2 FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Color code of cable type and connector attached cable Brown Black Blue Output 0 V Load + 5 to 24 V DC ±10 % Type Connector type Cable type Top sensing Front sensing L type (Top sensing) Top sensing Front sensing L type (Top sensing) Model No. Light-ON PM2-LH10 PM2-LF10 PM2-LL10 PM2-LH10-C1 PM2-LF10-C1 PM2-LL10-C1 Item Dark-ON PM2-LH10B PM2-LF10B PM2-LL10B PM2-LH10B-C1 PM2-LF10B-C1 PM2-LL10B-C1 Min. sensing object ø0.05 mm ø0.002 in copper wire (Setting distance: 5 mm 0.197 in) Hysteresis 20 % or less of operation distance with white non-glossy paper (15 × 15 mm 0.591 × 0.591 in) Repeatability (perpendicular to sensing axis) 0.08 mm 0.003 in or less (Note 3) Supply voltage 5 to 24 V DC ±10 % Ripple P-P 5 % or less Current consumption Average: 25 mA or less, Peak: 80 mA or less Output NPN open-collector transistor
- Maximum sink current: 100 mA
- Applied voltage: 30 V DC or less (between output and 0 V)
- Residual voltage: 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
Utilization category DC-12 or DC-13 Overcurrent protection Incorporated Response time 0.8 ms or less Operation indicator Red LED (lights up when the output is ON) Environmental resistance Pollution degree 3 (Industrial environment) Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +80 °C –13 to +176 °F Ambient humidity 45 to 85 % RH, Storage: 45 to 85 % RH Ambient illuminance Incandescent light: 3,500 ℓx at the light-receiving face EMC EN 60947-5 Vibration resistance 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each Emitting element Infrared LED (Peak emission wavelength: 880 nm 0.035 mil, modulated) Material Enclosure: Polycarbonate, Terminal part: Copper alloy (Ag plated) Enclosure: Polycarbonate, Fixed cable part: PBT Cable – 0.2 mm2 3-core cabtyre cable, 1 m 3.281 ft long (Note 4) Wiring length Total length up to 2 m 6.562 ft is possible with 0.3 mm2, or more, cable. If the cable is extended for 2 m 6.562 ft, or more, a capacitor of 10 µF must be connected between +V and 0 V terminals. Weight Net weight: 4.5 g approx. Gross weight: 85 g approx. (10 piece package) Net weight: 4 g approx. Gross weight: 80 g approx. (10 piece package) Net weight: 25 g approx Gross weight: 330 g approx (10 piece package) SPECIFICATIONS Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) The sensing range may extend up to 12.5 mm 0.492 in with white non-glossy paper due to product variation. 3) The repeatability is specified for white non-glossy paper (15 × 15 mm 0.591 × 0.591 in) at a setting distance of 5 mm 0.197 in. 4) Cable cannot be extended. I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram Color code of cable type and connector attached cable Users‚ circuit Internal circuit Sensor circuit (Brown) +V 100 mA max. Load (Black) Output (Blue) 0 V 5 to 24 V DC ±10 % Tr Z D Note: Make sure to connect terminals correctly as the sensor does not incorporate a reverse polarity protection circuit. Symbols ... ZD: Surge absorption zener diode Tr: NPN output transistor Wiring diagram
Convergent Reflective Micro Photoelectric Sensor PM2 SERIES 456 Selection Guide U-shaped Convergent Reflective PM2 FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS SENSING CHARACTERISTICS (TYPICAL) Sensing fields
- Horizontal (left and right) direction The sensors can be mounted side by side. However, if the sensor is slanted, there may be interference. Verify first whether there is any interference prior to use.
- Vertical (up and down) direction 0.079 0.039 0 1 0.039 0.079 Operating point ℓ (mm in) Setting distance L (mm in) Center Right Left Distance to convergent point White 0.079 0.197 0.394 0.315 0.157 0.236 Distance to convergent point Operating point ℓ (mm in) Setting distance L (mm in) Center Down Up White 0.079 0.157 0.197 0.236 0.315 0.394 0.079 0.039 0 1 0.039 0.079 The sensors can be mounted side by side. However, if the sensor is slanted, there may be interference. Verify first whether there is any interference prior to use. Vertical direction ℓ L 15 × 15 mm 0.591 × 0.591 in Non-glossy paper Sensor Correlation between lightness and sensing range N2 0 Lightness Light Dark N4 N6 N8 N2 N1 N3 N4 N5 N6 N7 N8 N9 Sensing range L (mm in) Distance to convergent point 0.079 0.157 0.197 0.236 0.315 0.394 Sensing region The sensing region (typical) is represented by oblique lines in the left figure. However, the sensitivity should be set with enough margin because of slight variation in products. Correlation between material (15 × 15 mm 0.591 × 0.591 in) and sensing range The bars in the graph indicate the sensing range (typical) for the respective material. However, there is a slight variation in the sensing range depending on the product. Further, if there is a reflective object (conveyer, etc.) in the background of the sensing object, since it affects the sensing, separate it by more than twice the sensing range shown in the left graph. Mirror Glossy stainless steel Glossy copper plate Non-glossy aluminum plate White non-glossy paper White ceramic circuit board Glass epoxy printed circuit board (Green masked surface) Black-painted, non-glossy iron plate Gray non-glossy paper (N5) Sensing range L (mm in) Distance to convergent point 0.197 0.394 0.591 0.787 Lightness shown on the left may differ slightly from the actual object condition. PRECAUTIONS FOR PROPER USE All models
- When fixing the sensor with screws, use M3 screws and the tightening torque should be 0.49 N·m or less. Further, use small, round type plain washers (ø6 mm ø0.236 in). O M3 screws Plain washer (Outer dia: ø6 mm ø0.236 in) Spring washer Purchase separately. Mounting Others
- Do not use during the initial transient time (50 ms) after the power supply is switched on.
- Take care that the product does not come in direct contact with oil, grease, or organic solvents, such as, thinner, etc. Wiring
- Make sure to connect terminals correctly as the sensor does not incorporate a reverse polarity protection circuit.
- If the sensor is being used in a noisy environment, examine the extent of noise. Further, if equipment, such as motor, solenoid or electromagnetic valve, which generates a large surge, is present near the sensor, connect a surge absorber to the equipment. Setting
- The optimum setting distance (distance to convergent point) is 5 mm 0.197 in. The sensor is not affected even by a specular background if it is located 30 mm 1.181 in, or more, away from the sensor. 5 mm 0.197 in Sensor Sensing object Background 30 mm 1.181 in or more However, the specular background should be a plane surface, directly facing the sensor. A spherical or curved background may be detected. Sensor 15 × 15 mm 0.591 × 0.591 in Non-glossy paper L ℓ Horizontal direction
- Never use this product as a sensing device for personnel protection.
- In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Refer to p.1458~ for general precautions.
Convergent Reflective Micro Photoelectric Sensor PM2 SERIES Selection Guide U-shaped Convergent Reflective PM2 FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Connector type Cautions in plugging or unplugging a connector Procedures of plugging or unplugging a connector
1 Insert a connector straight into a
sensor until the connector lug is locked by the sensor hook.
2 When unplugging, give as much
stress as a connector lug can be relieved from a hook. Then unplug it. Hook Lug
5 N or less
Caution: Be sure to hold a connector when plugging or unplugging it. Do not hold a terminal or a cable when plugging or unplugging the connector. Otherwise, it will cause a poor contact. CN 13 0V OUT +V 1.5 mm 0.059 in Soldering position 0V OUT+V Soldering (Both connector CN-13 and sensor)
- If soldering is done directly on the terminals, strictly adhere to the conditions given below. Soldering temperature 260 °C 500 °F or less Soldering time 10 sec. or less Soldering position Refer to the below figure Sensor Connector Wiring
- The cable length must be 2 m 6.562 ft, or less, with 0.3 mm2, or more, cable. If the cable is extended for more than 2 m 6.562 ft, connect a capacitor of 10 µF approx. between +V and 0 V terminals. 0V OUT + V 10 µF Cable 5 to 24 V DC ±10 % SensorPM2-LH10 PM2-LH10B 0.394 0.197 3.3 0.130 7.2 0.283 Sensing surface 1.024 0.787
0.551 Operation
indicator (Red) 2-mounting oblong holes 3.2 0.126 0.236 0.984 1 0.039 8.4 0.331 0.157 3.2 0.126 0.591 0.669 0.591 SensorPM2-LF10 PM2-LF10B 1.024 0.787 0.551 7.2 0.283 3.2 0.126 0.236 0.984 0.512 0.591 1 0.039 8.4 0.331 0.157 4 0.157 0.394 Sensing surface 2-mounting oblong holes Operation indicator (Red) 3.3 0.130 0.591 3.2 0.126 0.197 DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. PRECAUTIONS FOR PROPER USE
- Do not plug or unplug a connector more than 10 times.
- Be sure not to give stress more than 5 N to a terminal of both a connector and a sensor. If you do not follow the above cautions, it will cause a poor contact. Refer to p.1458~ for general precautions.
Convergent Reflective Micro Photoelectric Sensor PM2 SERIES 458 Selection Guide U-shaped Convergent Reflective PM2 FIBER SENSORS LASER SENSORS PHOTO- ELECTRIC SENSORS MICRO PHOTO- ELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASURE- MENT SENSORS STATIC ELECTRICITY PREVENTION DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 0.394 0.039 (6) (0.236) 0.157 0.5 0.020 t 0.2 t 0.008 2.8 0.110 0.197 0.039 0.039 0.8 0.031 1.6 0.063 (2.54) (0.100) (2.54) (0.100) 0.433 0.433 SensorPM2-LL10 PM2-LL10B CN-13 Connector (Optional) Sensing surface Operation indicator (Red) 2-mounting oblong holes 0.394 0.197 8.4 0.331 14.4 0.567 0.157 7 0.276 0.551 3.3 0.130 0.984 20 0.787 0.236 0.591 0.394 0.394 0.079 2 0.079 11.4 0.449 7.2 0.283 3.2 0.126 3.2 0.126 0.236 SensorPM2-LH10-C1 PM2-LH10B-C1 SensorPM2-LL10-C1 PM2-LL10B-C1SensorPM2-LF10-C1 PM2-LF10B-C1 0.039 0.8 0.031 1.6 0.063 2.1 0.083 1.3 0.051 0.039
0 V OUT
t 0.3 t 0.012 2.54 0.100 2.54 0.100 * Terminal part (Connector type) DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. 0.591 0.551 0.079 7.2 0.283 Operation indicator (Red) ø3.7 ø0.146 cable, 1 m 3.281 ft long 2-mounting oblong holes Sensing surface 0.394 3.2 0.126 ø5.2 ø0.205 8.4 0.331 0.157 5.4 0.213 3.1 0.122 0.197 0.591 0.039 3.3 0.130 0.551 20 0.787 1.024 0.276 12.4 0.488 0.669 25 0.984 Sensing surface 0.276 ø5.2 ø0.205 12.4 0.488 ø3.7 ø0.146 cable, 1 m 3.281 ft long 3.3 0.130 5.4 0.213 3.2 0.126 3.1 0.122 11.4 0.449 7.2 0.283 0.984 0.591 0.551 0.079 0.787 2-mounting oblong holes2 0.079 0.079 0.394 0.551 0.157 7 0.276 0.197 8.4 0.331 0.236 14.4 0.567 0.394 0.394 Operation indicator (Red) 8.4 0.331 4 0.157 3.1 0.122 1.024 0.551 20 0.787 Operation indicator (Red) 0.591 13 0.512 25 0.984 3.2 0.126 0.039 4 0.157 ø3.7 ø0.146 cable, 1 m 3.281 ft long 0.276 ø5.2 ø0.205 12.4 0.488 0.591 0.551 0.079 7.2 0.283 2-mounting oblong holes Sensing surface 5.4 0.213 0.394 3.3 0.130 0.197