PM22 SENSATA | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 7
Technical content
Features
- Output ratings up to 95 Amps at 600VAC
- Built-in overvoltage protection
- DBC substrate for superior thermal performance
- LED input status indicator
- IP20 touch-safe housing
- AC or DC control
- 4000 VAC optical isolation
- C-UL-US and TUV approved PRODUCT SELECTION Description 25 A 50 A 95 A Operating Voltage (47-440Hz) [Vrms] 48-600 48-600 48-600 Transient Overvoltage [Vpk] 3 1200 1200 1200 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 1 1 1 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] 500 500 500 Load Current, General Use UL508/LC A IEC 62314 @ 40°C [Arms] 4 25 50 95 Load Current, Motor Starting UL508 FLA/LC B IEC 62314 @ 40°C [Arms] 4 8.5/4.8 14/7.6 26/14 Minimum Load Current [Arms] 100 100 150 Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 286/300 716/750 1290/1350 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.35 1.35 1.30 Thermal Resistance Juntion to Case (Rjc) [°C/W] 0.49 0.27 0.2 Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 409/375 2563/2343 8320/7593 Minimum Heat Sink for Rated Current @ 40ºC [°C/W] 2 0.7 0.25 Minimum Power Factor (at Maximum Load) 5 0.5 0.5 0.5 Motor Rating UL 508/IEC62314 [HP (kW)]: 120 VAC 0.5 (0.37) 1 (0.74) 2 (1.5) Motor Rating UL 508/IEC62314 [HP (kW)]: 240 VAC 1.5 (1.1) 3 (2.2) 5 (3.73) Motor Rating UL 508/IEC62314 [HP (kW)]: 480 VAC 3 (2.24) 5 (3.7) 10 (7.4) SPECIFICATIONS Output (1)
www.sensata.com Page 2 Copyright © 2020 Sensata Technologies, Inc. Description PM2260DxxV PM2260AxxV Control Voltage Range 4-32 VDC 6 90-280 VAC/VDC 7 Maximum Reverse Voltage -32 VDC - Minimum Turn-On Voltage 4 VDC 90 VAC/VDC Must Turn-Off Voltage 1 VDC 5 VAC/VDC Minimum Input Current (for on-state) 7 mA 6 mA Maximum Input Current 15 mA 10 mA Nominal Input Impedance Current Regulated Current Limited Maximum Turn-On Time [msec] 1/2 Cycle 8 20 Maximum Turn-Off Time [msec] 1/2 Cycle 30 Description Parameters Dielectric Strength, Input to Output (50/60Hz) 4000 Vrms Dielectric Strength, Input/Output to Baseplate (50/60Hz) 4000 Vrms Minimum Insulation Resistance (@ 500 VDC) 109 Ohms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range 9 -40 to 80 °C Ambient Storage Temperature Range -40 to 100 °C Short Circuit Current Rating 10 100kA Weight (typical) 2.3 oz (65 g) Housing Material UL94 V-0 Baseplate Material Aluminum Hardware Finish Nickel Plating Input Terminal Screw Torque Range (lb-in/Nm) 5/0.5 11 Load Terminal Screw Torque Range (lb-in/Nm) 18-20 / 2-2.2 SSR Mounting Screw Torque Range (lb-in/Nm) 20-25/2.2-2.8 Humidity 95% non-condensing LED Input Status Indicator Green Input (1) General (1)
www.sensata.com Page 3 Copyright © 2020 Sensata Technologies, Inc. INPUT CURRENT INFORMATION SURGE CURRENT INFORMATION THERMAL DERATE INFORMATION 9 4-32 VDC Input 90-280 VAC/VDC Input PM2260x25V PM2260x50V PM2260x95V PM22xxx25x PM2260x50V PM2260x95V
www.sensata.com Page 4 Copyright © 2020 Sensata Technologies, Inc. EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAM *Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters] AD/DC Control DC Control Recommended Wire Sizes Terminal Configuration Wire Size (Solid / Stranded) Wire Pull-Out Strength (lb) [N] Output 2 x 20 AWG (0.75 mm2) [minimum] 25 [111] 2 x 10 AWG (6 mm2) 80 [355] Input Screw 2 x 8 AWG (10 mm2) [maximum] 90 [400] 30 AWG (0.05 mm2) [minimum] 4.5 [20] 12 AWG (3.3 mm2) [maximum] 30 [133] Spring 26 AWG (0.13 mm2) [minimum] 5 [22] 12 AWG (3.3 mm2) [maximum] 5 [22] MECHANICAL SPECIFICATIONS Input Connector Screw Terminal Spring Terminal
www.sensata.com Page 5 Copyright © 2020 Sensata Technologies, Inc. ORDERING OPTIONS Example : PM2260A25VRJH PM22 60 A 25 V R J H Series PM22 Operating Voltage 60: 48-600 VAC Control Voltage 1 A: 90-280 VAC/VDC D: 4-32 VDC Rated Load Current 25: 25 Amps 50: 50 Amps 95: 95 Amps Terminal Layout V: Contactor Configuration Switching Type Blank: Zero Voltage Turn-On R: Instantaneous Turn-On (Motor Rating Certified) Input Connector Blank: Screw Terminal J: Spring Terminal Thermal Pad Blank: Not Included H: Included GENERAL NOTES (1) Control voltage 18-52 VAC/VDC is available upon request. (2) All parameters at 25°C unless otherwise specified. (3) Output will self trigger between 900-1200 Vpk, not suitable for capacitive loads. (4) Heat sinking required, see derating curves. For load currents greater than 50A use conduc tors with at least 75°C insulation. (5) High inductive loads requires nominal control voltage; AC input models only. (6) Increase minimum voltage by 1 V for operations from -20 to -40°C. (7) For ambient temperatures above 40°C the maximum control voltage must not exceed 250 VAC/VDC. (8) Turn-on time for Instantaneous turn-on versions is 0.1 msec. (9) AC input models operating range is -20 to 60°C. (10) When protected with the appropriate class and rated fuse. For detailed info please contact Sensata Technical Support. (11) Input torque to screw terminals Connector. (12) For single surge pulse Tc=25°C; Tj=125°C. For AC Output SSRs, AC RMS value of surge current equals the peak value divided by √2 (1.414). Required for valid part number For options only and not required for valid part number
www.sensata.com Page 6 Copyright © 2020 Sensata Technologies, Inc. ACCESSORIES Connectors Part number: CP201, CP202 Hardware Kit Part number: HK8 Pluggable input connectors, 2 position, with screw terminals (CP201) or spring type terminals (CP202). Compatible with Contactor configuration NOVA22 SSRs. Bag with 2 SSR mounting screws 8-32 x 3/8, Hex Socket Cap, compatible with PM22 Series Panel Mount SSRs. Used to mount the SSR onto any of our compatible heat sinks. Heat Sink Part number: HS259DR Thermal Pad Part number: HSP-7 DIN Rail mountable heat sink with 2.5°C/W thermal resistance. Heat sink material is aluminum with black anodized finish. Suitable for mounting a single PM22 Series Panel Mount SSRs. Non-adhesive thermal pad for half-puck package SSRs. Compatible with PM22 Series Panel Mount SSRs. Recommended Accessories Connectors ID Marker Hardware Kit Thermal PadHeat Sink Part No. Thermal Resistance [ºC/W] CP201 CP202 CNLB CNLN CNL2 HK8 HS259DR HS073 HS072 HS053 HS033 HS023 2.5 0.7 0.7 0.5 0.36 0.25 HSP-7
www.sensata.com CONTACT US Americas +1 (877) 502 5500 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2020 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY, INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Rev. 04/27/2020 ECN 20395 FD E-07-01 Rev. B WARNINGS AGENCY APPROVALS & CERTIFICATIONS Certification in accordance with: United States Standard for Industrial Control Equipment - UL 508 and Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14. TUV Certified in accordance to EN62314 Vibration Resistance: IEC 60068-2-6: Amplitude Range 10-500 Hz, Displacement 0.75mm Shock Resistance: IEC 60068-2-27: Peak Acceleration 50g, Duration11ms. Electromagnetic Compatibility Generic Standard Immunity Tests Test Specification Level Performance IEC 61000-6-2 Immunity for Industrial Environments Electrostatic Discharge IEC 61000-4-2 8kV air discharge Criterion A 6kV contact discharge Criterion A Fast transients (burst) IEC 61000-4-4 Output 2kV, 5kHz, 100kHz Criterion B Input 1kV, 5kHz, 100kHz Criterion B Surge IEC 61000-4-5 Output 1kV Line to Earth Criterion B 2kV Line to Earth Criterion B AC Input Option 1kV Line to Earth Criterion A 2kV Line to Earth Criterion A RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE
- The product’s side panels may be hot, allow the product to cool before touching
- Follow proper mounting instructions including torque values
- Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power before installing or working with this equipment
- V erify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury.