PM200 POWERBOX | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

Features

  • Low safety ground leakage current.  Autoranging input.  Overvoltage protection.  Overcurrent protection.  Power fail detection (PFD) signal.  Optional cover and fan assembly.  100% burn-in at full rated load.  Short curcuit protected with auto-recvery Specifications INPUT Input Voltage 90-130/180-264Vac (Autoranging) Frequency 47Hz–67Hz Input Current 4.5A (rms) for 115Vac. 2.6A (rms) for 230Vac. Leakage current 90µA max. @ 115Vac. 60Hz. 150µA max. @ 230Vac. 50Hz. Isolation Input – Output: 4000VAC Input – Ground: 1500VAC Output – Ground: 500VAC Inrush Current 20A @ 115V, 40A @ 230V OUTPUT Output Voltage See table Output Voltage Adjustment V1 ±10% Output Current See table Ripple & Noise 2% peak to peak Line Regulation ±0.5% maximum at full load. Load Regulation See table Transient Response Max. deviation 4% recovering to 1% within 500µs after 25% load charge Overvoltage Protection Provided on V1 only. Set at 110%–132% of nominal Overcurrent Protection All outputs protected for short circuit conditions Temperature Coefficient All outputs ±0.04% per °C Holdup Time Typically 12mS at 110VAC PFD Signal Power fail detection signal. TTL logic low upon loss of input power. OPERATING MTBF 450,000 hrs @ 25°C Efficiency 70% minimum. ENVIRONMENTAL Operating Temperature 0°C to 70°C Derating Derate to 50% at 70°C Storage Temperature -40°C to 85°C Relative Humidity 5%–95% non-condensing Cooling 25 CFM forced air, provided on “C” version, to be provided for “B”version by user. STANDARDS AND APPROVALS Safety standards UL2601-1, CSA C22.2, TUV EN60601-1 C-Tick AS/NZS CISPR11 Group 1, Class A EMC standards EN60601-1-2: 2001,EN61000-3-2, -3, EMI standards EN55011 Class B, FCC Class B, VCCI Class B MECHANICAL Dimensions 229x127x65mm Weight 1.4Kgs for “B” version. 1.6Kgs for “C” version.

MEDICAL & MILITARY 343Your dependable power partner – www.powerbox.com.au Selection Table MAX. MODEL OUTPUT #1 OUTPUT #2 (2) OUTPUT #3 OUTPUT #4 (3) OUTPUT NUMBER(1)(5)(6) VNOM IMIN IMAX TOL VNOM IMIN IMAX TOL VNOM IMIN IMAX TOL VNOM IMIN IMAX TOL POWER (4) PM200-10 5V 3.0A 40A 2% 200W PM200-12 12V 1.2A 16.7A 2% 200W PM200-13 15V 1.0A 13.4A 2% 200W PM200-14 24V 0.6A 8.4A 2% 200W PM200-16 30V 0.5A 6.7A 2% 200W PM200-18 48V 0.5A 4.2A 2% 200W PM200-23 +5V 3.0A 30A 2% +12V 0A 8A 4% 200W PM200-24 +5V 3.0A 30A 2% +15V 0A 6A 4% 200W PM200-25 +5V 3.0A 30A 2% +24V 0A 4A 4% 200W PM200-30 +5V 3.0A 30A 2% +12V 0A 8A 4% -5V 0A 6A 4% 200W PM200-31 +5V 3.0A 30A 2% +12V 0A 8A 4% -12V 0A 4A 4% 200W PM200-32 +5V 3.0A 30A 2% +15V 0A 6A 4% -15V 0A 4A 4% 200W PM200-33 +5V 3.0A 30A 2% +15V 0A 6A 4% -12V 0A 4A 4% 200W PM200-40 +5V 3.0A 30A 2% +12V 0A 8A 4% -12V 0A 4A 4% 5V 0A 6A 4% 200W PM200-41 +5V 3.0A 30A 2% +15V 0A 6A 4% -15V 0A 4A 4% 24V 0A 4A 4% 200W PM200-42 +5V 3.0A 30A 2% +12V 0A 8A 4% -12V 0A 4A 4% 12V 0A 4A 4% 200W PM200-44 +5V 3.0A 30A 2% +12V 0A 8A 4% -15V 0A 4A 4% 15V 0A 4A 4% 200W PM200-45 +5V 3.0A 30A 2% +12V 0A 8A 4% -12V 0A 4A 4% 24V 0A 4A 4% 200W NOTES: (1) Add suffix “B” for U-bracket format and “C” for enclosed format. (2) Peak current is 12A on +12V, 9A on +15V and 6A on +24V. (3) Output #4 is floating. It can be connected externally for positive or negative output. (4) 200 watts for “C” version with a cover and fan assembly 150 watts for “B” version without moving air (maximum current of ouput #1 & #2 derated to 70%), or 200 watts with 25 CFM forced air provided by user. (5) When the remote Sense facility is not used, +Sense must be connected to +V, and -Sense to Return, on P2 connector. (6) All models may be operated at no-load. At no-load, output voltage tolerance increases to 10%. P1 P2 P3 MODEL/PIN 1 2 3 1,2 3,4,5 6 7 8 9 1 2 3 4 PM200-10 PM200-13 PM200-16 PM200-12 PM200-14 PM200-18 AC Live AC Neutral AC Ground -Sense RET. Output 1 Output 1 Output 1 +Sense Fan COM RET. COM RET. P. F. D. PM200-23 PM200-25 PM200-24 AC Live AC Neutral AC Ground Output 1 COM RET. RET. COM RET. P. F. D. PM200-30 PM200-32 PM200-31 PM200-33 AC Live AC Neutral AC Ground Output 1 COM RET. Output 2 Output 3 N.C. N.C. Fan COM RET. COM RET. P. F. D. PM200-40A PM200-42A PM200-45-1A PM200-41 PM200-44 AC Live AC Neutral AC Ground Output 1 COM RET. Output 2 Output 3 Output 4 Return Output 4 Fan COM RET. COM RET. P. F. D. PM200 Series

200 WATTS SINGLE & MULTIPLE OUTPUT AC/DC MEDICAL