PM12-T01-00-LOAD-20A E-T-A | Alldatasheet
Document overview
- Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
- PDF pages: 10
Technical content
PM12-T (LOAD) PM12-T (LOAD) The REX system’s PM12-T potential distribution modules can be divided into tw o m ain groups. Besides the + D C 24 V distribution, the 0 V minus distribution (GND) can be easily implemented in the same system. The slim modules save space and allow direct as- signment of the power distribution in the system. The direct assi- gnment can be easily displayed functionally in the related EPLAN providing support for wiring and trouble-shooting. POTENTIAL MODULES PM12-T (LOAD) TYPICAL FEATURES YOUR BENEFITS
- Device combination of supply module, overcurrent protection and power distribution module
- No accessories required for connecting the components
- Width per module only 12.5 mm
- Saves costs as no further accessories are required
- Saves 50 % tim e through innovative and flexible m ounting and connection technology
- Saves space with only 12.5 mm slim modules
- Provides flexibility through facilitated assem bly and disassem bly and modular design TYP. APPLICATIONS APPROVALS / CERTIFICATIONS Automation, machine building industry, process industry WEB LINKS COMPLIANCE Further information, Mounting and operation (videos), International approvals, Technical basics, REACH , RoHS , Contact global.e-t-a.com 3125
PM12-T (LOAD) GENERAL INFORMATION SAFETY AND INSTALLATION INSTRUCTIONS Installation must be done by a qualified electrician. Caution: Exchange / disassembly only in dead-voltage condition! Potentials will be interrupted. Mounting instruction: Mounting or actuation of the REX connector arm must only be effected at dead-voltage. For start-up, the REX connector arm must be closed. Note: Observe the data sheets for electronic circuit protectors in the REX portfolio, assembly /disassembly on DIN rail / moun- ting direction / m ounting area / sealing / application exam ple and m any m ore. FURTHER INFORMATION Mounting and operation (videos) https://www.e-t-a.de/index.php?id=17311 TECHNICAL DATA (T u = +23 °C, Ub = DC 24 V) ELECTRICAL DATA Rated voltage Un 0 V (GND); DC 24 V (LOAD) Operating voltage Ub 0...30 V (no battery-buffered applications) Dielectric strength Max. DC 30 V (load circuit) Maximum rated current 20 A (per module); max. 10 A per terminal Quiescent current I0 Typ. 20 m A Reverse polarity protection Yes, w ithout load Power failure bridging time 10 ms (tolerated up to 10 ms) Insulation co-ordination (EN IEC 60664)0.5 kV / Pollution degree: 2 MECHANICAL DATA Mounting dimensions (WxHxD) 12.5 x 80 x 98 mm (tolerances according to DIN ISO 286 part 1 IT13) Mass Approx. 52 g Enclosure material Plastic Mounting data DIN rail according to EN 60715-35x7.5 MOUNTING VALUES - PUSH-IN TERMINAL - PM12-T01-00-LOAD-20A Terminal connection capacity LOAD+ Cable cross section [mm2 ] Cable cross section [AWG]Stripping length [mm] flexible w ith w ire end ferrule w ith plastic sleeve flexible w ith w ire end ferrule w ithout plas- tic sleeve MOUNTING VALUES - PUSH-IN TERMINAL - PM12-T02-00-LOAD-20A Terminal connection capacity LOAD+ Cable cross section [mm2 ] Cable cross section [AWG]Stripping length [mm] flexible w ith w ire end ferrule w ith plastic sleeve global.e-t-a.com 3125
PM12-T (LOAD) flexible w ith w ire end ferrule w ithout plas- tic sleeve AMBIENT CONDITIONS Ambient temperature -30...+60 °C (without condensation, cf. EN 60204-1) Storage temperature -40...+70 °C Mounting temperature +5...+60 °C Damp heat Test according to IEC 60068-2-78, 3K3 climate class according to EN 6072196 hours at 95 % relative humidity, 40 °C Vibration Test according to IEC 60068-2-6 test Fc 5 g Corrosion Test according to IEC 60068-2-11, test Ka 96 hours at 5 % salt mist, IP code standard IEC 60529, DIN VDE 0470 Terminal area IP code (standard) IP20 (Terminals) Operating altitude 2,000 m a. sea level (SL) 3,000 m a. SL up to +55 °C 4,000 m a. SL up to +50 °C Maximum ambient pressure during ope- ration 4 bar above atmospheric pressure ORDERING NUMBER CODE P M T L O A D A
1 TYPE NUMBER
PM12 Potential module for REX system with PT connection technology, DC 24 V
2 MOUNTING
3 VERSION
01 1 x power input, 9 x LOAD+ 02 2 x separate power input, 4 x LOAD+ each 03 10 x GND / 0 V
4 ADDITIONAL FUNCTION 1
0 Without
5 ADDITIONAL FUNCTION 2
6 OPERATING VOLTAGE
LOAD Rated voltage DC 24 V GND Rated voltage DC 0...24 V
7 RATED CURRENT
8 ATEX APPROVAL
[No entry if no ATEX approval] -E ATEX/IECEx approval global.e-t-a.com 3125
PM12-T (LOAD) APPROVALS APPROVALS EM12-T Approval authority Test standard File Certificate No.Rated voltage [V] for types UL UL 1059 E335289 DC 24 PM12-T01-00- LOAD-20A PM12-T02-00- LOAD-20A PM12-T03-00-GN- D-20A Bureau Veritas ATEX 2014/34/EU EN 60079-0 EN 60079-7 EN 60079-15 EPS 24 ATEX 1 287 U DC 24 PM12-T01-00- LOAD-20A PM12-T02-00- LOAD-20A PM12-T03-00-GN- D-20A IECEx IEC 60079-0 IEC 60079-7 IEC 60079-15 IECEx EPS 24.0117U DC 24V PM12-T01-00- LOAD-20A PM12-T02-00- LOAD-20A PM12-T03-00-GN- D-20A UKEX EN IEC 60079-0 EN IEC 60079-7 EN IEC 60079-15 EPS 24 UKEX 1 289 U DC 24V PM12-T01-00- LOAD-20A PM12-T02-00- LOAD-20A PM12-T03-00-GN- D-20A UL APPROVALS UL 1059, File # E335289 COMPLIANCE According to 2014/30/EU global.e-t-a.com 3125
PM12-T (LOAD) DIMENSIONS DIMENSIONS DIMENSIONS global.e-t-a.com 3125
PM12-T (LOAD) INSTALLATION INSTRUCTIONS PREFERRED MOUNTING POSITION IN THE REX SYSTEM HORIZONTAL SCHEMATIC DIAGRAMS SCHEMATIC DIAGRAM SCHEMATIC DIAGRAM global.e-t-a.com 3125
PM12-T (LOAD) APPLICATION EXAMPLES MOUNTING / DISMOUNTING ON DIN RAIL IN THE REX SYSTEM EXCHANGE IN / DISMOUNTING FROM THE REX SYSTEM NETWORK global.e-t-a.com 3125
PM12-T (LOAD) MOUNTING / EXPANSION ON DIN RAIL IN THE REX SYSTEM APPLICATION EXAMPLE: EM12-T … WITH REX12-TAX… AND PM12-… global.e-t-a.com 3125
PM12-T (LOAD) DISTANCES BETWEEN CABLE DUCT AND LEVER IN THE REX SYSTEM global.e-t-a.com 3125
PM12-T (LOAD) SEALING OF THE REX SYSTEM ACCESSORIES OPTIONAL ACCESSORIES FROM REX12D-T W ith the com pact and flexible R EX system , E-T-A offers a sophisticated D C
24 V solution for protection and power distribution in mechanical and plant
engineering - consisting of power supply, overcurrent protection, distributi- on and bus controller. The REX12D-T circuit protector provides selective pro- tection, reacts faster than the switch mode power supply to short circuits or overloads and reliably sw itches on capacitive loads up to 20,000 µF. Available w ith fixed and adjustable current ratings from 1 A to 10 A, it fulfils not only UL508listed and NEC Class 2 but also exclusively EN 60204-1 for line pro- tection. All REX12D-T modules support BASE and COM mode - with simple message signalling or extensive communication and diagnostics just as re- quired. The operating mode is automatically recognised. REX12-T W ith the com pact and flexible R EX system , E-T-A offers a sophisticated D C engineering - consisting of power supply, overcurrent protection, distributi- on and bus controller. The REX12D-T circuit protector provides selective pro- tection, reacts faster than the switch mode power supply to short circuits or overloads and reliably sw itches on capacitive loads up to 20,000 µF. Available w ith fixed and adjustable current ratings from 1 A to 10 A, it fulfils not only UL508listed and NEC Class 2 but also exclusively EN 60204-1 for line protec- tion. REX22D-T E-T-A’s com pact and flexible R EX system represents a com prehensive D C 24 V protection- and power distribution solution for the machine building indus- try. It is a perfectly harmonised system including power supply, overcurrent protection, power distribution and bus controller. The REX22D-T selectively protects all DC 24 V load circuits up to 20 A and li- nearly limits the output current when switching on or before tripping. The li- mitation limits the rated current in the event of a short circuit. This allows ef- fective and calculable protection of switch mode power supplies, even with small power reserves. All information and data given on our products are accurate and reliable to the best of our knowledge, but E-T-A does not accept any responsibility for the use in applications which are not in accordance with the present specification. E-T-A reserves the right to change specifications at any time in the interest of technical improvement. Dimensions are subject to change without notice. Please enquire for the latest dimensional drawing with tolerances if required. All dimensions, data, pictures and descriptions are for information only and are not binding. Amendments, errors and omissions excepted. Ordering part numbers may differ from the device marking. global.e-t-a.com 3125