Technical content

Features

  • hermetic shielded case
  • very small phase variation

Applications

  • military, hi-rel applications
  • stabilizing generator outputs
  • reducing amplitude variations
  • providing constant amplitude signals in phase sensitive systemsPin Connections INPUT 1 OUTPUT 8 CONTROL 3,4^ GROUND 2,5,6,7 CASE GROUND 2 PLS-1+ POWER OUTPUT -7.0 -6.0 -5.0 -4.0 -3.0 -2.0 0 30 60 90 120 150 FREQUENCY (MHz) POWER OUTPUT (dBm) 20(dBm) 6(dBm) PLS-1+ AMPLITUDE Δ, OUT 0.0 0.1 0.2 0.3 0.4 0.5 0 30 60 90 120 150 FREQUENCY (MHz) AMPLITUDE DELTA, OUT (dB) 20-16(dBm) 16-10(dBm) 10-6(dBm) PLS-1+ PHASE Δ, OUT 0.0 1.0 2.0 3.0 4.0 5.0 0 30 60 90 120 150 FREQUENCY (MHz) PHASE DELTA, OUT (deg) 20-16(deg) 16-10(deg) 10-6(deg) ^ pins must be connected together externally Frequency (MHz) Power Output Delta (dB) Amplitude Delta, out dBm Input Phase Delta, Out dBm Input (20 dBm IN) (dBm) (6 dBm IN) (dBm) 20-16 (dB) 16-10 (dB) 10-6 (dB) 20-16 (deg.) 16-10 (deg.) 10-6 (deg.) * Typical output level at typical control current, level may be changed by varying current. Permanent damage may occur if any of these limits are exceeded. Parameter Condition Min. Typ. Max. Units Frequency Range — 0.1 — 150 MHz Input Power — 6.0 — 20 dBm Output Power* — — -4.0 — dBm Control Current — — 3.0 — mA Limiting ∆ Output/1dB ∆ Input Amplitude Input Power Range (dBm) 6 to 10 10 to 16 16 to 20 0.10 0.15 0.15 dB/dB Phase 6 to 10 10 to 16 16 to 20 0.8 0.8 0.7 °/dB Electrical Specifications +RoHS Compliant The +Suffix identifies RoHS Compliance. See our web site for RoHS Compliance methodologies and qualifications