Features
- RoHS compliant for all six substances
- 75 Watts with 5 CFM forced-air cooling
- Typical 80% efficiency
- 65 Watts with convection cooling
- 85-264 VAC wide-range input
- FCC & CISPR 22, Class "B" – Conducted EMI
- Power Factor Corrected (meets IEC61000-3-2)
- Typical 0.99 power factor
- Height meets 1U chassis constraints
- Two-year limited warranty
- Safety Agency pending to UL60960-1, CSA 22.2No. 60950-1-03, and TUV EN60950/IEC 60950-1
- Compliance with EN 61000-4-2 level 4 (ESD), EN 61000-4-3 (RF), EN 61000-4-4 level 3 (Fast Transient/Burst), EN 61000-4-5 class 3 (Surge)
DEC 04, 2006 revised to JAN 30, 2007 Page 2 of 6 www.power-one.com PLP75 AC-DC Series Data Sheet
75 Watts
Triple-Output Model Selection Model Nominal Output Voltage (VDC) Min-Max Output Current (Amps), Convection Min-Max Output Current (Amps), Forced Air 1 Peak Output Current (Amps) 2 Total Regulation (%) 3 Ripple & Noise pk-pk % 4 PLP75-3300G +3.3 5 +5 5 +12 0.2 - 7.5 0.3 - 3 0.0 - 0.7 0.2 - 8 0.3 - 4 0.0 - 1 4.6 1.5 PLP75-3301G +3.3 5 +12 -12 0.2 - 7.5 0.3 - 3 0.0 - 0.7 0.2 - 8 0.3 - 4 0.0 - 1 4.6 1.5 PLP75-3000G +5 5 +12 -12 0.2 - 7.5 0.3 - 3 0.0 - 0.7 0.2 - 8 0.3 - 4 0.0 - 1 4.6 1.5 PLP75-3003G +5 5 +15 -15 0.2 - 7.5 0.3 - 2.4 0.0 - 0.7 0.2 - 8 0.3 - 3.2 0.0 - 1 3.7 1.5 PLP75-3001G +5 5 +24 -12 0.2 - 7.5 0.3 - 2 0.0 - 0.7 0.2 - 8 0.3 - 2.6 0.0 - 1 2.6 1.5 1 CFM or 150 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm cross-sectional area) with power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC side to the DC side. 2 Peak current duration for less than 30 Sec with a max duty cycle of 10%. 3 At 25 °C ambient including voltage set point tolerance, line and load regulation. 4 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 5 Output is adjustable ±10 % of nominal. ELECTRICAL SPECIFICATIONS Input Specifications Parameter Conditions/Descripti on Min. Nom. Max. Units AC Input Voltage Range Continuous voltage range 85 100 - 250 264 VAC DC Input Voltage Range Continuous voltage range; For input above 250 VDC, consult factory. 120 170 250 VDC Frequency AC Input 47 50 - 60 63 Hz Power Factor Complies with EN61000-3-2 Standard for Line Current Harmonics Input current 85 VAC at 75 W 1.5 Amps rms Inrush current 115 VAC, Max power, 25 °C 16 A pk
230 VAC, Max power, 25 °C 32 A pk
Input fuse Non-user serviceable internally located AC input line fuse is provided. 2.5 A Efficiency At maximum output power, nominal line 80 %
DEC 04, 2006 revised to JAN 30, 2007 Page 3 of 6 www.power-one.com PLP75 AC-DC Series Data Sheet Parameter Conditions/Descripti on Min. Nom. Max. Units Output power With convection cooling With 5 CFM forced-air cooling
1 Watts
Output DC voltages Vo1 is adjustable ±10% of nominal. Vo2 is adjustable ±10% of nominal on PLP75- 3300G. Vo3 is not adjustable. VDC Output DC current 1 A Minimum load No damage occurs to the power supply when operating at zero load. 1 A Output ripple & noise 1 mV pk-pk CM noise 50 mV pk-pk Overshoot Vo1 overshoot at turn-on 3 % Load transient Vo1 deviation due to a 50 to 100% load change at a rate of 1A/µs ±3 % Turn-On & Turn-Off characteristics Outputs turn ON monotonically. Turn-on time from AC ON Time required for output within regulation after initial application of AC input. 0.2 1.5 Sec Turn-on Delay Tme required for output voltage to rise from 10% to 90%. 0.2 20 ms Hold-up Time Time Vo1 is required to stay within 95% regulation after removal of AC measure from the last peak of the AC line at 115 VAC. 20 ms Remote Sense Not available. Control loop stability Phase margin. 45 Degrees Gain margin. 10 dB 1 See Model Selection tables. Fault Protection Parameter Conditions/Descripti on Min. Nom. Max. Units Current Limit set point Overload protected - power limit. 145 % of peak rating Short-circuit protection Prov ided on all outputs. OVP Trip Vo1, Vo2 115 125 135 % of set point
DEC 04, 2006 revised to JAN 30, 2007 Page 4 of 6 www.power-one.com PLP75 AC-DC Series Data Sheet Parameter Conditions/Descripti on Min. Nom. Max. Units Input-to-Chassis 2121 VDC Input-to-Output 4242 VDC Output-to-Chassis 500 VDC Output-to-Output 1 1 All outputs share the same common. EMC Immunity Parameter Conditions/Description ESD EN 61000-4-2 Level 4. RF Susceptibility EN 61000-4-3 Level 3. Fast Transient/Burst EN 61000-4-4 Level 3. Surge EN 61000-4-5 Class 3. RF Immunity EN 61000-4-6. Magnetic Fields EN 61000-4-8. Voltage Interruptions EN 61000-4-11. EMC Emmisions Parameter Conditions/Description FCC Part 15 Conducted Class B, Radiated Class A. CISPR 22 and CISPR 11 Conducted Class B, Radiated Class A. Environmental Specifications Parameter Conditions/Descripti on Min. Nom. Max. Units Cooling Rated for convection and forced-air cooling. Audible Noise 0 dBA Operating Temp 0 ºC to 70 ºC with linear derating to 50% above 50 ºC. Unit will start-up at -20 ºC, but will not meet all published specifications. -20 50 70 ºC Altitude Operating. Non-Operating. 10K 50K ASL ft ASL ft Storage Temp -40 85 ºC Humidity 95% relative humidity @ 40 ºC, non-condensing Vibration Operating: Random vibration; 5 to 500 Hz (10 minutes, each axis). Non-Operating: Random vibration; 5 to 500 Hz (10 minutes, each axis). 2.4 Grms Grms Shock Operating: half-sine, 11 ±3 ms, 3-axis. Non-Operating: half-sine, 11 ±3 ms, 3-axis. G G
DEC 04, 2006 revised to JAN 30, 2007 Page 5 of 6 www.power-one.com PLP75 AC-DC Series Data Sheet Regulatory & Safety Approvals Parameter Conditions/Descripti on Min. Nom. Max. Units UL60950-1 All single-output models are approved. Triple- output models are pending. CSA-C22.2, No. 60950-1-03 All single-output models are approved. Triple- output models are pending. EN 60950-1 /IEC 60950-1 All single-output models are approved. Triple- output models are pending. CE Mark for LVD All single-output models are approved. Triple- output models are pending. CB Approval Completed for single-output models. Pending for triple-output models. Ground Leakage Current At 230 VAC. 1.4 mA Mechanical Specifications Parameter Conditions/Descripti on Min. Nom. Max. Units Dimensions Length 127 mm Width 76.2 mm Height, including component or component lead protrusion on the bottom of the PCB. 35 mm Power Density With forced-air cooling. 4 W/cu in Mounting (Location/Hardware); see Outline Drawing. Input (Location/Connector); J1 - Molex 26-62-4030 or equivalent. Ground connector for plastic chassis Provided. Output (Location/Connector); J2 - Molex 26-60-4060 or equivalent. Outline Drawing Pins/Functions See Mechanical Drawing. Weight 0.36 kg Mounting distance Note 1 0.113 in Optional Accessories Bracket, enclosure with IEC connector and switch, and cover options are offered. Consult factory for details. 1 The minimum distance from the bottom of the component leads (sol der side) or top of the components (component side) to the cust omer's metal chassis should be at least 0.113 " (2.85 mm).
DEC 04, 2006 revised to JAN 30, 2007 Page 6 of 6 www.power-one.com PLP75 AC-DC Series Data Sheet NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not des igned, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous envir onments, or nuclear control systems without the express wr itten consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safe ty agency certifications pictured on labels, may change dependi ng on the date manufactured. Specifications are subject to change without notice. 5.00 +/- 02 3.00 +/-.02 1.37 +/-.02 1.2 0.1 0.06 4.55 2.55 Ø 0.16 (4 places) Printed Circuit Board fastener clearance area 4 places) safety ground connection point J1 input connector J2 - DC output connector (see pin-out table) TOP VIEW SIDE VIEW END VIEW Pin 1 NEUTRAL Pin 2 missing pin Pin 3 LINE J1 - AC CONN. Pin #1 Pin #1 Pin 1* Vo1 Pin 2 Vo1 Pin 3 Vo1 Pin 4 DC COM Pin 5 DC COM Pin 6 DC COM J2 - DC CON (-1xxx models) safety ground connection point Pin 1 Vo2 Pin 2 Vo1 Pin 3 Vo1 Pin 4 DC COM Pin 5 DC COM Pin 6 Vo3 J2 - DC CON (-3xxx models)