6833007 TURCK | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 4

Technical content

Features

■Compact design ■For pressure and vacuum monitoring ■Rotatable sensor body ■Display rotatable by 360° ■Excellent EMC properties ■2 × PNP outputs, IO-Link ■Pressure range 0…10 bar rel. Wiring diagram Functional principle The pressure sensors of the PK product series operate using a silicon measuring cell. As a result of the pressure acting on the silicon, a signal that is proportional to the pressure is generated and processed electronically. The processed signal is available as a switching output or as digital process parameters. The sensors are intended only for use in non-aggressive gas and compressed- air applications. In the case of lubricated compressed air, it is recommended that the pressure connection points downward.

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 2|4 PK010R-P14-2UP8X-V1141 | 11/07/2023 23-59 | technical changes reserved Technical data IO-Link IO-Link specification V 1.1 Transmission physics Complies with 3-wire technology (PHY2) Frame type 2.2 Transmission rate COM 2/38.4 kbps Programming FDT/DTM Programming options Switching/release points; NC/NO; hysteresis/window mode; switch-on/ switch-off delay; pressure unit; diagnostic mode Mechanical data Housing material Plastic, ABS Process connection 1/4" NPT male thread Pressure transducer material Silicon Wrench size pressure connection / coupling nut SW 16 Electrical connection Connector, M8 × 1 Protection class IP65 Environmental conditions Ambient temperature -10…+60 °C Storage temperature -20…+85 °C Shock resistance 10 g (11 ms) acc. to IEC 68-2-27 Vibration resistance 10 to 55 Hz, 1.5 mm, XYZ 2 h EMV Emitted interference acc. to EN 61000 EN 61000‐6‐4* Intrinsically safe acc. to EN 61000‐6‐2* * shielded connection cable recommended Tests/approvals Reference conditions acc. to IEC 61298-1 Temperature 15…+25 °C Atmospheric pressure 860…1060 hPa abs. Humidity 45…75 % rel. Auxiliary power 24 VDC Displays/Operating elements Display 3-digit 7-segment display, rotatable by 360° Switching state 2 × LEDs, Yellow/yellow Temperature behaviour MTTF 318 years acc. to SN 29500 (Ed. 99) 40

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 3|4 PK010R-P14-2UP8X-V1141 | 11/07/2023 23-59 | technical changes reserved Technical data Type PK010R-P14-2UP8X-V1141 ID 6833007 Pressure range Pressure type Relative pressure Pressure range 0…10 bar 0…145.04 psi 0…1 MPa Admissible overpressure ≤ 15 bar Response time < 2.8 ms Power supply Operating voltage 10.8…30 VDC Short-circuit/reverse polarity protection yes / yes Protection type and class IP65 Outputs Output 1 Switching output or IO-Link mode Output 2 Switching output Switching output Output function NO/NC, PNP Accuracy ± 2 % FS BSL Rated operational current 0.25 A Switching frequency ≤ 200 Hz Switch point: 0…100 % IO-Link IO-Link specification V 1.1 Programming FDT/DTM Transmission physics Complies with 3-wire technology (PHY2) Transmission rate COM 2/38.4 kbps Frame type 2.2 Temperature behaviour Medium temperature 0…+60 °C Temperature coefficient ± 0.2 % of full scale/10 K Environmental conditions Ambient temperature -10…+60 °C Storage temperature -20…+85 °C Vibration resistance 10 to 55 Hz, 1.5 mm, XYZ 2 h Shock resistance 10 g (11 ms) acc. to IEC 68-2-27 EMV Emitted interference acc. to EN 61000 EN 61000‐6‐4* Intrinsically safe acc. to EN 61000‐6‐2*

TURCK Inc. | 3000 Campus Drive Minneapolis, MN 55441-2656 | Phone: 763-553-7300 | Application Support: 1-800-544-7769 | Fax 763-553-0708 | www.turck.com 4|4 PK010R-P14-2UP8X-V1141 | 11/07/2023 23-59 | technical changes reserved Technical data * shielded connection cable recommended Mechanical data Housing material Plastic, ABS Pressure transducer material Silicon Process connection 1/4" NPT male thread Wrench size pressure connection / coupling nut SW 16 Electrical connection Connector, M8 × 1 Reference conditions acc. to IEC 61298-1 Temperature 15…+25 °C Atmospheric pressure 860…1060 hPa abs. Humidity 45…75 % rel. Auxiliary power 24 VDC Displays/Operating elements Display 3-digit 7-segment display, rotatable by 360° Switching state 2 × LEDs, Yellow/yellow Programming options Switching/release points; NC/NO; hysteresis/window mode; switch-on/ switch-off delay; pressure unit; diagnostic mode Tests/approvals MTTF 318 years acc. to SN 29500 (Ed. 99) 40