POWR-GARD® Protection Relays, Monitors & Systems © 2010 Littelfuse • POWR-GARD® Protection Relay Catalogwww.littelfuse.com/pgm-8600 PGM-8600 Serie S (GF r4001- iM) Insulation Monitor

Description

The PGM-8600 relay monitors the insulation resistance to ground for failures. It provides two warnings, one alarm, and an analog output for predictive maintenance. The relay can operate on 1 or 3-phase grounded, resistance grounded or ungrounded systems up to 6 kV . When the power system is de-energized, the relay monitors the insulation for damage, allowing for predictive maintenance and troubleshooting for developing ground faults. When the power system is energized in ungrounded systems, the relay continues to monitor the insulation. In grounded systems, the relay switches off to prevent nuisance tripping. The mode of operation terminals (27-28) are connected to the circuit breaker or contactor auxiliary contacts to toggle the relay off when the contactor or breaker is closed. PGH FAMILY POWR-GARD® HIGH-TENSION COUPLER PHASE CONDUCTOR (<1300V) INSULATION MONITOR PGM-8600 SERIES POWR-GARD ® CONTROL POWER 10 k /uni03A9 TRIP RELA Y50 k /uni03A9 ALARM RELA Y 0-1mA RESET 50 k /uni03A9 RESET 10 k /uni03A9 ANALOG OUTPUT MODE OF OPERATION 2 5 6 10 11 12 13 14 15 18 19 21 22 27 28 29 30 PHASE CONDUCTOR (>1300 V) N 240 V PGA-0510 (optional) POWR-GARD® ANALOG OHM METER 25 26 (required >1300 V) Specifications IEEE Device Numbers Lockout Relay (86) Input Voltage 240 Vac, 50–60 Hz Dimensions H 99.7 mm (3.9"); W 75 mm (3"); D 110 mm (4.3") Resistance Ratings Insulation warnings (30 k Ω and 50 kΩ) Insulation alarm (10 kΩ) Contact Operating Mode Non-fail-safe Test Button Standard feature Reset Button Standard feature Output Contacts Two Form C Communications Analog output Conformally Coated Optional Warranty 5 years Mounting DIN, Surface CataloG/ SySteM NUMBer CoNtrol Power PGM-8600 240 Vac

Ordering Information

Supplemental Monitoring (PGM 8000 Family) PGA-0510 Analog Ohm Meter Optional PGA-0510 Analog meter allows for remote metering of insulation resistance. PGH Family High T ension Couplers Required (for systems >1,300 V) PGH Family high-tension coupler must be connected between the phase conductor and the PGM-8600 insulation monitor. Accessories A B aCCeSSorieS reqUireMeNt PaGe PGH Family Required >1300 V 42 PGA-0510 Optional 41 Wiring Diagram A B FeatUreS BeNeFitS Analog Output (0 – 1 mA) Provides means for connecting an optional PGA-0510 meter to display insulation resistance. Output Contacts (50 kΩ) Form C output contact for alarming purposes Output Contacts (10 kΩ) Form C output contact for tripping purposes Features & Benefits Note: For optional conformal coating please consult factory.