Features

  • Power and fault status indicators
  • Provides identification of a ground fault vs. short circuit trip
  • Chemical and UV resistant enclosure
  • Trip level of sensing device < 30mA (27mA nominal) at trip time of < 100mS (60mS nominal) per E-11
  • Protection range and operating voltage: 0 - 50 Amps, 120 VAC, 120/240 VAC
  • Unit operating temperature is -35°C to +66°C
  • Accommodates up to 3 wires, 6 AWG, with no twisting of the wires required Type E-11 GFP - UL 943 Category FTTJ2 when used in tandem with Airpax LEL series (UL 489 listed circuit breaker with shunt trip) Operating Voltage 120 VAC or 120/240 VAC, 50/60 Hz Interrupting Voltage Rating of UL 489 listed circuit breaker Sensing Coil Voltage Limit 600 VAC maximum Phase Interrupt Single (120 VAC 3 wire), Split (120/240 VAC 4 wire) , 240VAC 3-wire (L1, L2, N) Interrupting Current 120VAC, 50A, 5kAIC 120/240VAC, 50A, 5kAIC Trip Time of Combined Assembly 100mS or less (60mS nominal) Trip Level 27mA +/- 3mA Operating Temperature -35°C to +66°C Reset Type Automatic on power up ABYC E-11 Acceptability The LineGard™ PGFM ELCI module used in tandem with the Airpax™ circuit breaker meets the requirements of the ABYC (American Boat and Yacht Council) E-11 standard covering AC and DC systems on boats Note: 1. Manual configuration should be specified if automatic start-up after power restoration of circuit power creates an unsafe condition. 2. As per UL 943 requirements, portable devices may require breaking of neutral during ground fault detection. Please contact the factory. 3. Please contact Airpax for optional ELCI, UL 1053 compliant devices.

www.sensata.com Page 2 Copyright © 2018 Sensata Technologies, Inc. WIRING DIAGRAM Voltage Current Frequency Short Circuit Poles 125VAC 0.05 to 50 amps 50/60 Hz 5,000 amps 1 to 3 120/240VAC .05 to 50 amps 50/60 Hz 5,000 amps 2 to 3 AIRPAX™ LEL & IDLNK SERIES CIRCUIT BREAKER RATINGS (PER UL489) AIRPAX™ LEL & IDLNK SERIES CIRCUIT BREAKER SPECIFICATIONS Wiring Diagram (120VAC APPLICATION) Wiring Diagram (240 VAC APPLICATION) Moisture Resistance MIL-STD-202, Method 106 Salt Spray (Corrosion) MIL-STD-202, Method 101 Shock MIL-STD-202, Method 213, Test Condition I with 100% rated current applied Vibration MIL-STD-202, Method 204, Test Condition A with 100% rated current applied LEL Agency Approvals UL489 Listed, CSA Certified, VDE Approved, CCC Approved, CE Compliant IDLNK Agency Approvals UL 1077 Recognized, C22.2 No. 235 complaint to UL 1500 or SAE J1171 ignition protection Salt Fog (Corrosion) ASTM B117 Shock 33CFR183.534 - modified to supply 5,000 shocks @ 25G, instead of test standard of 1,000 shock Vibration MIL-STD-810 (random vibe 4G RMS), IEC 6945 (sine sweep 5 to 100 Hz for low frequency) Ignition Protection SAE J1171 (UL1500) NEUTRAL (white) to breaker line side NEUTRAL HOT (black) to master pole* of breaker NEUTRAL (white) to breaker line input HOT (black) to master pole* of breaker SHUNT (yellow) to breaker auxiliary switch (NO terminal) NEUTRAL (white) from power supply (source) HOT (black) from power supply (source) L1 (black) to master pole* of breaker L2 (red) to breaker line side L2 L1 (black) to master pole* of breaker L2 (red) to circuit breaker line input SHUNT (yellow) to breaker auxiliary switch (NO terminal) L1 (black) from power supply (source) L2 (red) from power supply (source)

www.sensata.com Page 3 Copyright © 2018 Sensata Technologies, Inc. Wiring Diagram (120/240 VAC APPLICATION) Wiring Diagram (Orange Jumper Wire For Circuit Breaker) Installation Instructions Testing And Troubleshooting L1 (black) to master pole* of breaker NEUTRAL (white) to breaker line side NEUTRAL L1 (black) to master pole* of breaker L2 (red) to circuit breaker line input NEUTRAL (white) to circuit breaker line input SHUNT (yellow) to breaker auxiliary switch (NO terminal) L1 (black) from power supply (source) L2 (red) from power supply (source) NEUTRAL (white) from power supply (source) *Master pole is the pole that houses the toggle handle on the breaker 1. Read and follow all instructions 2. Identify all the features and wires (see drawings) 3. Identify line wires and load wires 4. Verify that the ratings on the device, including the circuit breaker, match your field line ratings 5. Strip wires to 5/8”, or as recommended for your connections (module may include field terminations) 6. Choose the right wiring application (120VAC or 120/240VAC split phase) and connect wires according to diagrams 7. Place supplied test instruction label in close proximity to the ground fault sensing module mounting location. NOTE: The ground wire should be connected externally. The Ground wire does not enter or exit the ground fault sensing module. Although the PGFM does not monitor ground leads or require ground to operate, ground connection is recommended and should be made at junction box. In the normal operating state, the PGFM green LED is “ON” and circuit breaker is in the “ON” position. 1. Press “TEST” button: Green LED should go “OFF” and red LED should come “ON” and circuit breaker should trigger to “OFF” position 2. If sensing device red LED does not illuminate or breaker does not trip or change state, DO NOT USE and consult an electrician for assistance 3. Press “RESET” button: Red LED should turn “OFF” and green LED should turn “ON” 4. Manually reset (switch) the circuit breaker to the “ON” position to restore circuit power WARNING: If the test fails, do not use this ELCI. Consult a qualified electrician for repair or replacement C NO LINE LOAD DANGER! Hazard of electrical shock, burn or explosion. Disconnect power at main power feed before you start installation. Failure to do so may cause severe shock, personal injury, or death.

www.sensata.com Page 4 Copyright © 2018 Sensata Technologies, Inc. DIMENSIONAL DRAWINGS Dimensional Drawings (Pgfm Marine) Dimensional Drawings (Example Of Lel, Typical 2-Pole Configuration) 1.850 [46.99] 0.007 [0.18] 2.353 [59.77] 1.320 [33.53] 0.657 [16.68] 2.655 [67.44] DIAMETER 2.788 [70.82] DIAMETERM3.0 x .5 THREADED BRASS INSERTS FOR MOUNTING (2) PLACES .710 [18.03] DIAMETER (LARGE ENOUGH FOR THREE 6GA. WIRES) 16 GA. WIRE 105 DEGREES C UL STYLE 1015 / 1230 600V CSA TEW 10 IN LONG +/- 1 IN COLOR WIRE 1: WHITE 120V, RED 240V COLOR WIRE 2: BLACK 120V, BLACK 240V COLOR WIRE 3: YELLOW 120V, YELLOW 240V WIRE 3 WITH QUICK DISCONNECT MOLEX PN 19006-0015 OR EQUIVALENT [7.14] .281 [49.28] 1.940 [16.46] .648 [26.80] 1.055 [5.59] .220 [52.32] 2.060 [61.93] 2.438 MAX. [10.21] .402 [36.53] 1.438 [63.25] 2.490 [38.48] 1.515 MAX. 4X M3 ISO THD. .140 [3.56] DEEP [29.13] 1.147 [18.31] .721 [65.02] 2.560 [3.56] .140 [47.22] 1.859 [3.61] .142 [17.53] .690 32˚ 32˚ ON OFF [6.35] .250 [9.03] .356 [0.76] .030 [24.25] .955 CNONC [6.35] .250 [4.75] .187 1REC5 C & NO 4X M5 SCREW [19.05] .750 Panel MountingDetail Tolerance ±.005[.13] unless noted. 1.30 [33.0] 2.18 [55.4] 2.52 [64.0] 3.41 [86.6] 2.62 [66.5] 3.67 [93.2] 3.28 [83.3] M3 inserts Recommended torque 4 - 5 inch pounds

www.sensata.com Page 5 Copyright © 2018 Sensata Technologies, Inc. Compatible Airpax™ Circuit Breakers - Ul 1077 Recognized; Ignition Protected Per Sae J1171 (Ul 1500) Dimensional Drawings (Example Of Idlnk, Typical 2-Pole Configuration) Amps Poles Part Number Voltage Trip Coil Short Circuit Delay Curve 30 2 IDLNK21-1REC5-38140-30-G1 120V 120V 5000A 800700600500400300200150 125 1000 TIME IN SECONDS 1000 100 .01 10000 .001 PERCENT OF RATED CURRENT 1000900 DELAY 63 MAY TRIP 30 2 IDLNK21-1REC5-38140-30-G2 240V 240V 5000A 30 3 IDLNK121-1REC5-39945-30-G1 120/240V 120V 5000A 50 2 IDLNK21-1REC5-38140-50-G1 120V 120V 5000A 50 2 IDLNK21-1REC5-38140-50-G2 240V 240V 5000A 50 3 IDLNK121-1REC5-39945-50-G1 120/240V 120V 5000A 6-32 Mtg Screw for High Shock Mtg [51.82] 2.040 [3.61] .142 [24.25] .955 [19.05] .750 [34.92] 1.375 [16.66] .656 [63.25] 2.490 .0325 ± 0.0025 [0.83 ± 0.064] DEEP .0625 ± 0.0025 [1.59 ± 0.064] WIDE [15.88] .625 [3.30] .130 [19.05] .750 [13.08] .515 [16.66] .656 1/2-32 Hex Nut OFF 13˚ ± 3˚ ON 13˚ ± 3˚ Lockwasher Rubber “O” Ring [38.48] 1.515 KEYWAY MAX Panel MountingDetail Tolerance ±.005[.13] unless noted. Compatible Airpax™ Circuit Breakers - Ul 489 Listed; Vde Per En 60934 (Non-Ignition Protected) Amps Poles Part Number Voltage Trip Coil Short Circuit Delay Curve 30 2 LEL12-1REC5-37583-30-G1-V 120V 120V 5000A 800700600500400300200150 125 1000 TIME IN SECONDS 1000 100 .01 10000 .001 PERCENT OF RATED CURRENT 1000900 DELAY 63 MAY TRIP 30 2 LEL12-1REC5-37583-30-G2-V 240V 240V 5000A 30 3 LEL121-1REC5-37275-30-G1-V 120/240V 120V 5000A 50 2 LELK12-1REC5-37583-50-G1-V 120V 120V 5000A 50 2 LELK12-1REC5-37583-50-G2-V 240V 240V 5000A 50 3 LELK121-1REC5-37275-50-G1-V 120/240V 120V 5000A

www.sensata.com CONTACT US Americas 508-236-2551 electrical-protection-sales@ sensata.com Europe, Middle East & Africa +31743578156 info-sse@list.sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2018 Sensata Technologies, Inc. Sensata Technologies, Inc. (“Sensata”) data sheets are solely intended to assist designers (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, evaluation and judgment in designing Buyer’s systems and products. Sensata data sheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular data sheet. Sensata may make corrections, enhancements, improvements and other changes to its data sheets or components without notice. Buyers are authorized to use Sensata data sheets with the Sensata component(s) identified in each particular data sheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATA SHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATA SHEETS OR USE OF THE DATA SHEETS, EXPRESS, IMPLIED OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATA SHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA. Revised 7/31/18 ORDERING OPTIONS WARNINGS RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions can result in death or serious injury. PGFM-111-B-A1-188 UP TO 50A 120V AUTO ROUND MARINE 27mA +/- 3mA ELCI PGFM-211-B-A1-188 UP TO 50A 240V AUTO ROUND MARINE 27mA +/- 3mA ELCI PGFM-111-B-A1-188A UP TO 50A 120V AUTO ROUND MARINE 27mA +/- 3mA (Turned 90 Degrees) ELCI PGFM-111-B-A1-187 UP TO 50A 120V AUTO RECT. MOD (POTTED) 27mA +/- 3mA ELwCI PGFM-211-B-A1-187 UP TO 50A 240V AUTO RECT. MOD (POTTED) 27mA +/- 3mA ELCI PGFM-211-B-A1-291 UP TO 50A 240V AUTO RECT. MOD 18mA +/- 2mA ELCI PGFM-111-B-A1 UP TO 50A 120V AUTO RECT. MOD (W/ SHUNT TRIP) 5mA +/- 1mA GFCI ELCI Marine (Round) Modules Elevated Trip Mod’s Class A Mod’s