PFR 120 x 120 x 38 MM SERIES OUTLET SIDE INLET SIDE mm (INCH)UNIT: UNIT : (INCH) mm 105.0±0.3 (4.134±0.012) 120.0±0.5 (4.724±0.020) 8-Ø4.5±0.3 330 ±10.0 LABEL 120.0±0.5 (4.724±0.020) 105.0±0.3 (4.134±0.012) 10.0 (0.394) (0.197±0.012) (1.496±0.020) 38.0±0.5 5.0±0.3 (0.197±0.012) 5.0±0.3 PFR1212XE (mm H2O) (IN H2O) Air Flow 0 50 150100 250 8.0 16.0 0.31 0.63 0 1.6 24.0 32.0 40.0 1.26 0.94 1.57 3.2 4.8 6.4 8.0 (CFM) (M3/MIN) 48.0 Air Pressure DH UH 200 4-Ø4.5 (4-Ø0.177) 105.0 (4.134) Ø132.5 (Ø5.216) (4.645) 105.0 (4.134) (4.645) 4-Ø4.5 (4-Ø0.177) 105.0 (4.134) Ø126.8 (Ø4.992) (4.645) 105.0 (4.134) (4.645) 118.0 118.0 118.0 118.0 108 http://www.deltaww.com ■ DIMENSIONS DRAWING * Bearing Type Ball Bearings * Material Impeller & Frame: Plastic (UL 94V-0) * Lead Wires : UL 1430 AWG #22 OR Equivalent Red Wire Positive(+) Black Wire Negative(-) * Weight : 410g (14.46 oz) ■ P & Q CURVE (AT RATED VOLTAGE) ■ MOUNTING PANEL CUTOUT MODEL Rated Voltage Operating Voltage Range Input Current Input Power Speed Maximum Air Flow Maximum Air Pressure Noise PART NO. FUNCTION VDC VDC Amp Watt R.P.M. m3 /min CFM mmH2O IN H2O dB-A * Function type is optional. * The max. air flow and the speed are measured in free air ; max. air pressure is measured at zero air flow. * Noise is measured in anechoic chamber in free air, one meter from intake side. * All readings are typical values at rated voltage. * Specifications are subject to change without notice.