PF480D25 SENSATA | Alldatasheet

Document overview

  • Manufacturer or author: Provided By alldatasheet.com(free datasheet download site)
  • PDF pages: 5

Technical content

Features

  • SIP style SSR
  • Ratings up to 25 A (forced air) @ 660 VAC
  • SCR output for heavy industrial loads
  • AC or DC control
  • Zero voltage (resistive loads) or instantaneous (inductive loads) turn-on output PRODUCT SELECTION SPECIFICATIONS Control Voltage 25 A 25 A 25 A 3-15 VDC PF240D25 4-15 VDC PF380D25 PF480D25 15-32 VDC PFE240D25 PFE380D25 PFE480D25 18-36 VAC PFE240A25 90-140 VAC PF240A25 Description PF240 PF380 PF480 Operating Voltage (47-63 Hz) [Vrms] 12-280 48-530 48-660 Transient Overvoltage [Vpk] 600 1200 1200 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 0.1 0.1 0.1 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/ μsec] 2 500 500 500 Maximum Load Current (Convection Air) [Arms] 3 10 10 10 Maximum Load Current (Forced Air) [Arms] 3 25 25 25 Minimum Load Current [Arms] 0.06 0.06 0.06 Maximum Surge Current (16.6 msec) [Apk] 250 250 250 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 Maximum I² t for fusing (8.3 msec) [A² sec] 260 260 260 Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5 Output1

www.sensata.com Page 2 Copyright © 2024 Sensata Technologies, Inc. Description PF240D25 PF380D/480D PFExxxD25 PF240A25 PFE240A25 Control Voltage Range 3-15 VDC 4-15 VDC 15-32 VDC 90-140 Vrms 18-36 Vrms Typical Input Current @ Nominal Voltage [mA] 15 15 15 10 10 Nominal Input Impedance [Ohm] 300 240 1.5K 14.1K 2.1K Maximum Turn-On Time [msec] 4 1/2 Cycle 1/2 Cycle 1/2 Cycle 10 10 Maximum Turn-Off Time [msec] 1/2 Cycle 1/2 Cycle 1/2 Cycle 40 40 Description Parameters Dielectric Strength, Input/Output (50/60 Hz) 4000 Vrms Minimum Insulation Resistance (@ 500 V DC) 109 Ohms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -30ºC to 80ºC Ambient Storage Temperature Range -30ºC to 125ºC Weight (typical) 1.02 oz. (29g) Encapsulation Thermally Conductive Epoxy LOAD TRIGGER CIRCUI T B A AC -DC+ DC Load can be wired in location A or B AC 2 1LOAD Load can be wired in location A or B LOAD TRIGGER CIRCUIT 4 V LOAD B A AC AC AC AC 2 1 AC/DC Converter EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAMS Input1 General

www.sensata.com Page 3 Copyright © 2024 Sensata Technologies, Inc. THERMAL DERATE INFORMATION MECHANICAL SPECIFICATIONS *Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters]

1.55 TYP

(39.4) 1.35 MAX (34.3) .100 (2.5) 1.6 T Y P. (38.1)

www.sensata.com Page 4 Copyright © 2024 Sensata Technologies, Inc. PF E 240 D 25 R Series PF Control Voltage Blank: 3-15 VDC (240, D suffix only) 4-15 VDC (380/480, D suffix only) 90-140 VAC (A suffix only) E: 15-32 VDC (D suffix only) 18-36 VAC (A suffix only) Operating Voltage 240: 12-280 VAC 380: 48-530 VAC 480: 48-660 VAC Control Input Type D: DC Input A: AC Input Rated Load Current 25: 25 Amps Switching Mode Blank: Zero Voltage Turn-On R: Instantaneous Turn-On AVAILABLE OPTIONS Example : PFE240D25R Required for valid part number For options only and not required for valid part number

www.sensata.com CONTACT US Americas +1(800) 350 2727 sales.crydom@sensata.com Europe, Middle East & Africa +44 (1202) 416170 ssr-info.eu@sensata.com Asia Pacific sales.isasia@list.sensata.com China +86 (21) 2306 1500 Japan +81 (45) 277 7117 Korea +82 (31) 601 2004 India +91 (80) 67920890 Rest of Asia +886 (2) 27602006 ext 2808 Copyright © 2024 Sensata Technologies, Inc. Datasheets provided by Sensata Technologies, Inc., its subsidiaries and/or affiliates (“Sensata”) are solely intended to assist third parties (“Buyers”) who are developing systems that incorporate Sensata products (also referred to herein as “components”). Buyer understands and agrees that Buyer remains responsible for using its independent analysis, valuation, and judgment in designing Buyer’s systems and products. Sensata datasheets have been created using standard laboratory conditions and engineering practices. Sensata has not conducted any testing other than that specifically described in the published documentation for a particular datasheet. Sensata may make corrections, enhancements, improvements, and other changes to its datasheets or components without notice. Buyers are authorized to use Sensata datasheets with the Sensata component(s) identified in each particular datasheet. HOWEVER, NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER SENSATA INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY THIRD PARTY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT, IS GRANTED HEREIN. SENSATA DATASHEETS ARE PROVIDED “AS IS”. SENSATA MAKES NO WARRANTIES OR REPRESENTATIONS WITH REGARD TO THE DATASHEETS OR USE OF THE DATASHEETS, EXPRESS, IMPLIED, OR STATUTORY , INCLUDING ACCURACY OR COMPLETENESS. SENSATA DISCLAIMS ANY WARRANTY OF TITLE AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY , FITNESS FOR A PARTICULAR PURPOSE, QUIET ENJOYMENT, QUIET POSSESSION, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS WITH REGARD TO SENSATA DATASHEETS OR USE THEREOF. All products are sold subject to Sensata’s terms and conditions of sale supplied at www.sensata.com. SENSATA ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR THE DESIGN OF BUYERS’ PRODUCTS. BUYER ACKNOWLEDGES AND AGREES THAT IT IS SOLELY RESPONSIBLE FOR COMPLIANCE WITH ALL LEGAL, REGULATORY , AND SAFETY-RELATED REQUIREMENTS CONCERNING ITS PRODUCTS, AND ANY USE OF SENSATA COMPONENTS IN ITS APPLICATIONS, NOTWITHSTANDING ANY APPLICATIONS-RELATED INFORMATION OR SUPPORT THAT MAY BE PROVIDED BY SENSATA. Mailing Address: Sensata Technologies, Inc., 529 Pleasant Street, Attleboro, MA 02703, USA Rev. 07/09/2024 ECN 21039 FDE-07-01 Rev. B WARNINGS GENERAL NOTES (1) All parameters at 25°C unless otherwise specified. (2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (3) Heatsink temperature 85°C Maximum for 25A forced air cooling. (4) Turn-On Time for Instantaneous Turn-On versions 0.1 msec (DC Control Models) AGENCY APPROVALS & CERTIFICATIONS Designed in accordance with the requirements of IEC 62314 RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE

  • The product’s side panels may be hot, allow the product to cool before touching
  • Follow proper mounting instructions including torque values
  • Do not allow liquids or foreign objects to enter this product Failure to follow these instructions can result in serious injury, or equipment damage. HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
  • Disconnect all power before installing or working with this equipment
  • Verify all connections and replace all covers before turning on power Failure to follow these instructions will result in death or serious injury. (Except AC Control and 380V, DC Control, Instantaneous)