Features

  • Best”in”class, 80 PLUS certified “Platinum” efficiency
  • Wide input voltage range: 90”264 VAC
  • AC input with power factor correction
  • Always”On 16.5W programmable standby output (3.3/5 V)
  • Hot”plug capable
  • Parallel operation with active digital current sharing
  • Full digital controls for improved performance
  • High density design: 14.0 W/in
  • Small form factor: 54.5 x 40.0 x 321.5 mm
  • I 2C communication interface for control, programming and monitoring with PSMI and PMBus™ protocol
  • Overtemperature, output overvoltage and overcurrent protection
  • 256 Bytes of EEPROM for user information
  • 2 Status LEDs: AC OK and DC OK with fault signaling

Description

The PFE600”12”054NA is a 600 watt, AC to DC power”f actor”corrected (PFC) power supply that converts st andard AC mains power into a main output of 12 VDC for powering int ermediate bus architectures (IBA) in high performan ce and reliability servers, routers, and network switches. The PFE600”12”054NA meets international safety standards and displays the CE”Mark for the European Low Voltage Directive (LVD). 0 100 200 300 400 500 600 Po [W] Power Factor Vi = 230VAC; fan external Vi = 230VAC; fan internal Platinum 0.8 0.82 0.84 0.86 0.88 0.9 0.92 0.94 0.96 0.98 0 100 200 300 400 500 600 Po [W] Power Factor 230VAC 115VAC

ORDERING INFORMATION

PFE Front”Ends Power Level 600W Dash V1 Output 12V Dash Width 54mm Airflow N: normal R: reversed Input A: AC D: DC

BCD.00037 Rev. AB, 19”Jan”2011 Page 2 / 8 www.power-one.com PFE600-12-054NA Short Form Data Sheet

600 Watts, 12 VDC Output

1 ENVIRONMENTAL AND MECHANICAL

Parameter Conditions / Description Min Nom Max Unit T A Ambient temperature V i min to V i max , I1 nom , ISB nom 0 +45 °C T Aext Extended temp range Derated output (600 to 450W out put power) +45 +65 °C T S Storage temperature Non”operational ”20 +70 °C N a Audible noise V i nom , 50% Io nom , T A = 25°C 42 dBA Dimensions Width 54.5 mm Height 40.0 mm Depth 321.5 mm M Weight 950 g

2 INPUT SPECIFICATIONS

General Condition: T A = 0… 45 °C unless otherwise noted. Parameter Conditions / Description Min Nom Max Unit V i nom Nominal input voltage 100 230 240 VAC V i Input voltage ranges Normal operating (V i min to V i max ) 90 264 VAC Ii max Max input current 8.5 A rms Ii p Inrush Current Limitation V i min to V i max , 90°, T NTC = 25°C 40 A p F i Input frequency 47 50/60 64 Hz PF Power Factor V i nom , 50Hz, > 0.2 I1 nom 0.9 W/VA V i on Turn”on input voltage 1) Ramping up 80 87 VAC V i off Turn”off input voltage 1) Ramping down 75 85 VAC η Efficiency without fan V i nom , 0.1·Ix nom , V x nom , T A = 25 °C 85.4 % V i nom , 0.2·Ix nom , V x nom , T A = 25 °C 92.8 V i nom , 0.5·Ix nom , V x nom , T A = 25 °C 94.5 V i nom , Ix nom , V x nom , T A = 25 °C 94.0 T hold Hold”up Time After last AC zero point, V 1 > 10.8 V, V SB within regulation, V i = 230 VAC, P x nom 20 ms 1) The Front”End is provided with a minimum hysteresis of 3 V during turn”on and turn”off within the ranges.

BCD.00037 Rev. AB, 19”Jan”2011 Page 3 / 8 www.power-one.com PFE600-12-054NA Short Form Data Sheet

3 OUTPUT SPECIFICATIONS

General Condition: T a = 0 … +45 °C unless otherwise noted. Parameter Conditions / Description Min Nom Max Unit Main Output V1 V 1 nom Nominal output voltage 0.5 ·I1 nom , T amb = 25 °C 12.0 VDC V 1 set Output setpoint accuracy ”0.5 +0.5 % V 1 nom dV 1 tot Total regulation V i min to V i max , 0 to 100% I1 nom , T a min to T a max ”1 +1 % V 1 nom P 1 nom Nominal output power V 1 = 12 VDC 600 W I1 nom Nominal output current V 1 = 12 VDC 50.0 ADC v 1 pp Output ripple voltage V 1 nom , I1 nom , 20 MHz BW, 2Pcs 47µF/16V/X5R/1210 at V 1 150 mVpp dV 1 Load Load regulation V i = V i nom , 0 ” 100 % I1 nom 33 mV dV 1 Line Line regulation V i =V i min… V i max 0 mV I1 max Current limitation T a < 45 °C 52.5 55 ADC dIshare Current sharing Deviation from I1 tot / N, I1 > 10A ”3 +3 A dV dyn Dynamic load regulation ∆ I1 = 50% I1 nom , I1 = 5 … 100% I1 nom , dI1/d t = 1 A/µs, recovery within 1% of V 1 nom ”0.6 0.6 V T rec Recovery time 1 ms tAC V1 Start”up time from AC V 1 = 10.8 VDC 2 sec tV1 rise Rise time V 1 = 10…90% V 1 nom 1 10 ms C Load Capacitive loading V1 T a = 25 °C 30000 µF Standby Output VSB V SB nom Nominal output voltage 0.5 ·ISB nom , T amb = 25 °C VSB_SEL = 1 3.3 VDC VSB_SEL = 0 5.0 VDC V SB set Output setpoint accuracy VSB_SEL = 0 / 1 ”0.5 +0.5 %V SBnom dV SB tot Total regulation V i min to V i max , 0 to 100% ISB nom , T a min to T a max ”1 +1 %V SBnom P SB nom Nominal output power VSB_SEL = 0 / 1 16.5 W ISB nom Nominal output current V SB = 3.3 VDC 5 ADC V SB = 5.0 VDC 3.3 ADC v SB pp Output ripple voltage V SB nom , ISB nom , 20 MHz BW, 10µF/16V/X7R/1206 at V SB 40 mVpp dV SB Droop 0 ” 100 % ISB nom VSB_SEL = 1 67 mV VSB_SEL = 0 44 mV ISB max Current limitation VSB_SEL = 1 5.25 6 ADC VSB_SEL = 0 3.45 4.3 ADC dV SBdyn Dynamic load regulation ∆ ISB = 50% ISB nom , ISB = 5 … 100% ISB nom , dIo/d t = 0.5 A/µs, recovery within 1% of V 1 nom ”3 3 %V SBnom T rec Recovery time 250 µs tAC VSB Start”up time from AC V SB = 90% V SB nom 2 sec tVSB rise Rise time V SB = 10…90% V SB nom 4 20 ms

BCD.00037 Rev. AB, 19”Jan”2011 Page 4 / 8 www.power-one.com PFE600-12-054NA Short Form Data Sheet Parameter Conditions / Description Min Nom Max Unit Standby Output VSB (Cont.) C Load Capacitive loading T amb = 25 °C 10000 µF

4 SIGNALING AND CONTROL

4.1 FRONT LEDS

Table 1: LED Status Operating Condition LED Signaling AC LED AC Line within range Solid Green AC Line UV condition Off DC LED 1) PSON High Blinking Yellow (1:1) Hot”Standby Mode Blinking Yellow/Green (1:2) V 1 or V SB out of regulation Solid Yellow Over temperature shutdown Output over voltage shutdown ( V 1 or V SB ) Output over current shutdown ( V 1 or V SB ) Fan error (>15%) Over temperature warning Blinking Yellow/Green (2:1 ) Minor fan regulation error (>5%, <15%) Blinking Yel low/Green (1:1) 1) The order of the criteria in the table corresponds to the testing precedence in the controller. The front”end has 2 front LEDs showing the status o f the supply. LED number one is green and indicates AC po wer is on or off, while LED number two is bi”colored: g reen and yellow, and indicates DC power presence or fault situations. For the position of the LEDs see Figure 5. 4.2 GRAPHICAL USER INTERFACE Power”One provides with its “Power”One I 2C Utility” a Windows® XP/Vista/Win7 compatible graphical user interface allowing the programming and monitoring o f the PFE600”12”054NA Front”End. The utility can be downloaded on www.power”one.com and supports both the PSMI and PMBus™ protocols. The GUI allows automatic discovery of the units connected to the communication bus and will show them in the navigation tree. In the monitoring view the pow er supply can be controlled and monitored. If the GUI is used in conjunction with the PFE600”1 2” 054NA Evaluation Kit it is also possible to control the PSON pin(s) of the power supply. Further there is a button to disable the internal f an for approximately 10 seconds. This allows the user to t ake input power measurements without fan consumptions t o check efficiency compliance to the Climate Saver Computing Platinum specification. Figure 1: I2C Bus to DSP and EEPROM The monitoring screen also allows to enable the hot ” standby mode on the power supply. The mode status i s monitored and by changing the load current it can b e monitored when the power supply is being disabled f or further energy savings. This obviously requires 2 p ower supplies being operated as a redundant system (like the evaluation kit). Note: The user of the GUI needs to ensure that only one of the power supplies have the hot”standby mode enabled.

BCD.00037 Rev. AB, 19”Jan”2011 Page 5 / 8 www.power-one.com PFE600-12-054NA Short Form Data Sheet

5 ELECTROMAGNETIC COMPATIBILITY

5.1 IMMUNITY

Note: Most of the immunity requirements are derived from EN 55024:1998/A2:2003. Test Standard / Description Criteria ESD Contact Discharge IEC / EN 61000”4”2, ±8 kV, 25+25 discharges per test point (metallic case, LEDs, connector body) B ESD Air Discharge IEC / EN 61000”4”2, ±15 kV, 25+25 discharges per test point (non ”metallic user accessible surfaces) B Radiated Electromagnetic Field IEC / EN 61000”4”3, 10 V/m, 1 kHz/80% Amplitude Modulation, 1 µ s Pulse Modulation, 10 kHz…2 GHz A Burst IEC / EN 61000”4”4, level 3 AC port ±2 kV, 1 minute DC port ±1 kV, 1 minute B Surge IEC / EN 61000”4”5 Line to earth: level 3, ±2 kV Line to line: level 2, ±1 kV B RF Conducted Immunity IEC/EN 61000 ”4”6, Level 3, 10 Vrms, CW, 0.1 … 80 MHz A Voltage Dips and Interruptions IEC/EN 61000”4”11 1: Vi 230V, 100% Load, Phase 0°, Dip 100%, Duration 10 ms 2: Vi 230V, 100% Load, Phase 0°, Dip 100%, Duration 20 ms 3: Vi 230V, 100% Load, Phase 0°, Dip 100%, Duration >20ms A A B 5.2 EMISSION Test Standard / Description Criteria Conducted Emission EN55022 / CISPR 22: 0.15 … 30 MHz, QP and AVG, single unit Class A 6 dB margin EN55022 / CISPR 22: 0.15 … 30 MHz, QP and AVG, 2 units in rack system Class A 6 dB margin Radiated Emission EN55022 / CISPR 22: 30 MHz … 1 GHz, QP, single unit Class A 6 dB margin EN55022 / CISPR 22: 30 MHz … 1 GHz, QP, 2 units in rack system Class A 6 dB margin Harmonic Emissions IEC61000 ”3”2, Vin = 100 VAC/ 60 Hz, 100% Load Class A IEC61000 ”3”2, Vin = 120 VAC/ 60 Hz, 100% Load Class A IEC61000 ”3”2, Vin = 200 VAC/ 60 Hz, 100% Load Class A IEC61000 ”3”2, Vin = 230 VAC/ 50 Hz, 100% Load Class A IEC61000 ”3”2, Vin = 240 VAC/ 50 Hz, 100% Load Class A Acoustical Noise Sound power statistical declaration (ISO 9296, ISO 7779, IS9295) @ 50% load 42 dBA

BCD.00037 Rev. AB, 19”Jan”2011 Page 6 / 8 www.power-one.com PFE600-12-054NA Short Form Data Sheet

6 MECHANICAL

6.1 DIMENSIONS

321.5 ±0.4 25 2.4 34.6 14 0.6 13.4 Figure 2: Side view 1 9.5 80 12.25 4.4 Figure 3: Top view 0.6 8.75 Figure 4: Side view 2 Main PCB 8.75 0.6 2.15 12.258 54.5 10.5 22 1.6 44.04 9.44 5.23 0.6 14 Figure 5: Front view AC LED DC LED Note: A 3D step file of the power supply casing is available on request. Air Flow Direction Note: Unlatching the supply is performed by pulling the green trigger in the handle.

BCD.00037 Rev. AB, 19”Jan”2011 Page 7 / 8 www.power-one.com PFE600-12-054NA Short Form Data Sheet

6.2 CONNECTIONS

Unit: Tyco Electronics P/N 2”1926736”3 Note: Colu mn 5 is lagging (short pins) Counter part: Tyco Electronics P/N 2”1926733”5 Pin Name Description Output 6, 7, 8, 9, 10 V1 +12 VDC main output 1, 2, 3, 4, 5 PGND Power ground (return) Control Pins A1 VSB Standby positive output (+3.3/5 V) B1 VSB Standby positive output (+3.3/5 V) C1 VSB Standby pos itive output (+3.3/5 V) D1 VSB Standby positive output (+3.3/5 V) E1 VSB Standby positive output (+3.3/5 V) A2 SGND Signal ground (return) B2 SGND Signal ground (return) C2 HOTSTANDBYEN Hot standby enable signal D2 VSB_SENSE_R Standby output negative sense E2 VSB_SENSE Standby output positive sense A3 APS I2C address and protocol selection (select by a pull down resistor) B3 nc Reserved C3 SDA I2C data signal line D3 V1_SENSE_R Main output negative sense E3 V1_SENSE Main output positive sense A4 SCL I2C clock signal line B4 PS ON Power supply on input (connect to A2/B2 to turn unit on) C4 SMB_ALERT SMB Alert signal output D4 nc Reserved E4 AC OK AC input OK signal A5 PSKILL Power supply kill (lagging pin) B5 ISHARE Current share bus (laggin g pin) C5 PW OK Power OK signal output (lagging pin) D5 VSB_SEL Standby voltage selection (lagging pin) E5 PRESENT_L Power supply present (lagging pin)

BCD.00037 Rev. AB, 19”Jan”2011 Page 8 / 8 www.power-one.com PFE600-12-054NA Short Form Data Sheet

7 ACCESSORIES

Item Description Ordering Part Number Source Power-One I 2 C Utility Windows XP/Vista/7 compatible GUI to program, control and monitor PFE Front”Ends (and other I units) N/A www.power”one.com USB to I 2 C Converter Master I 2C device to program, control and monitor I2C units in conjunction with the Power-One I 2 C Utility ZM”00056 Power”One Dual Connector Board Connector board to operate 2 PFE units in parallel. Includes an on”board USB to I 2C converter (use Power-One I 2 C Utility as desktop software). SNP”OP”BOARD”01 Power”One Copyright © 2010 Power”One Inc. All rights reserved . Words and logos that are identified as trademarks and/or service marks are, unless noted otherwise, the trademarks are protected under numerous U.S. and foreign paten ts and pending applications, maskwork rights, and c opyrights. Power”One reserves the right to make cha nges to any products and services at any time without notice. P ower”One assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in writing by Power”One Inc. 1. NUCLEAR AND MEDICAL APPLICATIONS ” Power”One pr oducts are not designed, intended for use in, or au thorized for use as critical components in life sup port systems, equipment used in hazardous environments, or nuclear control systems without the express writ ten consent of the respective divisional president of Power”One, Inc. 2. TECHNICAL REVISIONS ” The appearance of products , including safety agency certifications pictured o n labels, may change depending on the date manufact ured. Specifications are subject to change without notice.