DF-G2_V01 BANNER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 9

Technical content

energized or de-energized sensor output condition. Figure 1. DF-G2 Model Features

1 Output LED

2 LO/DO Switch

3 RUN/PRG/ADJ Mode Switch

4 Lever Action Fiber Clamp

5 Red Signal Level

6 Green Threshold

1 Connector options:

  • For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G2-NC-9M)
  • For 150 mm (6 in) PVC cable with a 5-pin M8/Pico-style QD model, change the suffix 2M to Q3 in the 2 m model number (example, DF-G2-NC-Q3)
  • For Q3 and Q7 models, use a 5-pin M8/Pico-style or a 6-pin M8/Pico-style mating cordset DF-G2 High Speed Expert™ Dual Display Small Object Counter Original Document 178061 Rev. E

9 September 2015

Dimensions Fiber Exit Minimum Object Size 3 PFCVA-10X25-S 10 mm x 25 mm Side exit 1.5 mm PFCVA-10X25-E End exit PFCVA-25X25-S 25 mm x 25 mm Side exit 3 mm PFCVA-25X25-E End exit PFCVA-34X25-S 34 mm x 25 mm Side exit 4 mm PFCVA-34X25-E End exit Installation Instructions Mounting Instructions Mount on a DIN Rail 1. Hook the DIN rail clip on the bottom of the DF-G2 over the edge of the DIN rail (1). Push the DF-G2 up on the DIN rail (1). 3. Pivot the DF-G2 onto the DIN rail, pressing until it snaps into place (2). Mount to the Accessory Bracket 1. Position the DF-G2 in the SA-DIN-BRACKET. Insert the supplied M3 screws. 3. Tighten the screws. Remove from a DIN rail 1. Push the DF-G2 up on the DIN rail (1). Pivot the DF-G2 away from the DIN rail and remove it (2). 2 Custom fiber arrays and mounting configurations are possible. Consult factory for assistance with your small object counting application.

3 With 2% threshold offset percentage

DF-G2 High Speed Expert™ Dual Display Small Object Counter 2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 178061 Rev. E

Follow these steps to install glass or plastic fibers. Open the dust cover. 2. Move the fiber clamp forward to unlock it. 3. Insert the fiber(s) into the fiber port(s) until they stop. 4. Move the fiber clamp backward to lock the fiber(s). 5. Close the dust cover. Fiber Emitter Port Fiber Receiver Fiber Clamp Port Move forward to release the fibers Fiber Adapters NOTE: If a thin fiber with less than 2.2 mm outer diameter is used, install the fiber adapter provided with the fiber assembly to ensure a reliable fit in the fiber holder. Banner includes the adapters with all fiber assemblies. TO FIBERS TO SENSOR Fiber Outer Diameter (mm) Adapter Color Ø 1.0 Black Ø 1.3 Red Ø 2.2 No adapter needed When connecting coaxial-type fiber assemblies to the amplifier, install the single-core fiber to the Transmitter port, and the multi-core fiber to the Receiver port. This will result in the most reliable detection. TRANSMITTER RECEIVER Single-core fiber Multi-core fiber DF-G2 High Speed Expert™ Dual Display Small Object Counter P/N 178061 Rev. E www.bannerengineering.com - Tel: +1-763-544-3164 3

(N.O.) 10–30 V dc3 Health Load NPN Models Remote Programming (N.O.) 10-30V dc Load Health Key 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray (6 = no connection) NOTE: Open lead wires must be connected to a terminal block. Top Panel Interface Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ mode switch, LO/DO switch, +/SET/- rocker button, dual red/green digital displays, and output LED. RUN/PRG/ADJ Mode Switch The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode. RUN mode allows the sensor to operate normally and prevents unintentional programming changes via the +/SET/- rocker button. PRG mode allows the sensor to be programmed through the display-driven programming menu (see Program Mode below). ADJ mode allows the user to perform Expert TEACH/SET methods and Manual Adjust (see Adjust Mode below). LO/DO Switch The LO/DO switch selects Light Operate or Dark Operate mode. In Light Operate mode, the output is ON when the sensing condition is above the threshold. (For Window SET, the output is ON when the sensing condition is inside the window.) In Dark Operate mode, the output is ON when the sensing condition is below the threshold. (For Window SET, the output is ON when the sensing condition is outside the window.) +/SET/- Rocker Button The +/SET/- rocker button is a 3-way button. The +/- positions are engaged by rocking the button left/ right. The SET position is engaged by clicking down the button while the rocker is in the middle position. All three button positions are used during PRG mode to navigate the display-driven programming menu. During ADJ mode, SET is used to perform TEACH/SET methods. The rocker button is disabled during RUN mode, except when using Window SET, see Window SET on page Red/Green Digital Displays During RUN and ADJ modes, the Red display shows the signal level, and the Green display shows the threshold or the total counts. During PRG mode, both displays are used to navigate the display-driven programming menu. Output LED The output LED provides a visible indication when the output is activated. DF-G2 High Speed Expert™ Dual Display Small Object Counter 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 178061 Rev. E

For more information about how to perform TEACH/SET methods and to program the sensor remotely, see www.bannerengineering.com and search 178236. Run Mode Run mode allows the sensor to operate normally and prevents unintentional programming changes. The +/SET/- rocker button is disabled during RUN mode, except when using Window SET, see Window SET on page 6. In RUN Mode, the SET function of the +/SET/- rocker button allows the user to toggle between the threshold center value and the total number of counts on the Green display. If the Totalizer function is enabled, the total counts value increments to the programmed value and then starts over at 0. If the Totalizer function is disabled, the total counts value increments to 9999 and then starts over at 0. Changing any operational setting causes the total counts value to reset to 0. Program Mode (+) or (-) to set value (+) or (-) to set value (+) or (-) to set value (display flips 180˚) Click SET to enter choice list Press and hold SET to exit choice list without saving DISPLAY LOOP Return to Menu List PROGRAM MODE Mode Switch to “PRG” Click SET to enter choice list DISPLAY LOOP Click SET to enter choice list Click SET to enter choice list Click SET to enter choice list Click SET to enter choice list Click SET to enter choice list DISPLAY LOOP Click SET to enter choice list DISPLAY LOOP To scroll through menu lists: Press “+” or “-” To enter a choice list or to select and save: Click SET To exit a choice list without saving: Press and hold SET for 2 seconds + - SET rocker button Click SET to select and save a choice in any list Menu List on display represents a “w” on display represents a “m” (+) or (-) to set value Figure 2. Program (PRG) mode allows the following settings to be programmed in the DF-G2 DF-G2 High Speed Expert™ Dual Display Small Object Counter P/N 178061 Rev. E www.bannerengineering.com - Tel: +1-763-544-3164 5

Sliding the RUN/PRG/ADJ mode switch to the ADJ position allows the user to perform Expert TEACH/SET methods.

  • Light SET
  • Dynamic TEACH Window SET
  • Sets window thresholds that extend a programmable % offset above and below the presented condition
  • All other conditions (lighter or darker) cause the output to change state
  • Recommended for applications where a product may not always appear in the same place, or when other signals may appear
  • See Program Mode in the user's manual for programming the Offset Percent setting (to increase/decrease the window size) A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and below the presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside the window, and the Output OFF conditions outside the window. Sensor positions window thresholds a programmable % offset from the presented condition Darkest (no signal) Most Light (saturated signal) Condition Presented Sensing Window Output OFF Output OFFOutput ON

Figure 3. Window SET (Light Operate shown) Output ON and OFF conditions can be reversed using the LO/DO switch.

  • Changes output state on any condition darker than the threshold condition
  • Recommended for applications where only one condition is known, for example a stable light background with varying darker targets
  • See Program Mode on page 5 for programming the Offset Percent setting DF-G2 High Speed Expert™ Dual Display Small Object Counter 6 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 178061 Rev. E

SET Result % Offset Meaning PASS (with % Offset) Displays the % offset used for the SET method FAIL (with % Offset) Displays the minimum required % offset necessary to PASS the SET method FAIL (without % Offset) Presented condition cannot be used for the SET method Health Mode Alarm The Health Mode Alarm alerts you when preventative maintenance becomes necessary to ensure reliable sensing. The Health Mode output 2 is Active when the system is OK and operating normally. Health Mode output 2 becomes Inactive when the system is in a marginal state because of contamination. The system still operates normally and can detect small objects, but is nearing the alarm state. When the system is completely contaminated and unable to ensure reliable sensing, the system goes into the alarm state. In the alarm state, the discrete output 1 is forced to the blocked state and can no longer be used to detect small objects. Threshold Alert displays when Health Mode output 2 is inactive because of contamination. The system operates normally but is nearing the alarm state. Threshold Error displays when discrete output 1 is forced to the blocked state and can no longer be used to detect small objects. The sensor may enter Health Mode Alarm for any of these reasons: When first powered up; the fiber optic array may already be contaminated 2. If the Window SET procedure fails, indicating the fiber optic array is contaminated and the sensor could not set a valid clear-state light level for reliable detection 3. If the fiber optic array is contaminated enough that the auto compensation tracking algorithm cannot sufficiently adjust the thresholds to ensure reliable detection 4. If the fiber optic array is blocked for more than 2 seconds Return the system to normal operation by cleaning the fiber optic array and performing a Window SET to reset the clear- state light level (see Window SET on page 6). Specifications Sensing Beam Visible red, 635 nm Supply Voltage 10 to 30 V dc Class 2 (10% maximum ripple) Power and Current Consumption (exclusive of load) Standard display mode: 960 mW, Current consumption < 40 mA at 24 V dc ECO display mode: 720 mW, Current consumption < 30 mA at 24 V dc Supply Protection Circuitry Protected against reverse polarity and transient overvoltages Delay at Power-Up 500 milliseconds maximum; outputs do not conduct during this time Output Configuration 1 current sinking (NPN) or 1 current sourcing (PNP) output, depending on model, plus 1 Health Mode output Output Rating 100 mA maximum combined load (derate 1 mA per °C above 30 °C) OFF-state leakage current: < 5 μ A at 30 V dc; ON-state saturation voltage: NPN: < 1.5 V; PNP : < 2 V Output Protection Protected against output short-circuit, continuous overload, transient overvoltages, and false pulse on power-up Output Response Time 25 µs 50 µs 150 µs 250 µs 500 µs Repeatability 12 µs 12 µs 30 µs 50 µs 80 µs Connections PVC-jacketed 2 m or 9 m (6.5 ft or 30 ft) 5-wire integral cable; or integral 5-pin M8/Pico-style quick disconnect; or 150 mm (6 in) cable with a 5-pin M12/Euro-style quick disconnect; or 150 mm (6 in) cable with a 5-pin M8/Pico-style quick disconnect For Q3 or Q7 5-pin models, either a 5-pin M8/Pico-style or a 6-pin M8/Pico-style mating cordset may be used Construction Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear polycarbonate cover Environmental Rating IEC IEC IP50 , NEMA 1 Operating Conditions Temperature: − 10 °C to +55 °C (+14 °F to +131 °F) Storage Temperature: − 20 °C to +85 °C (− 4 °F to +185 °F) Humidity: 90% at +60 °C maximum relative humidity (non- condensing) DF-G2 High Speed Expert™ Dual Display Small Object Counter 8 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 178061 Rev. E

Required Overcurrent Protection WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to http://www.bannerengineering.com. Supply Wiring Required Overcurrent Protection 20 5.0 Amps 22 3.0 Amps 24 2.0 Amps 26 1.0 Amps 28 0.8 Amps 30 0.5 Amps Certifications Industrial Control Equipment 3TJJ Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. DF-G2 High Speed Expert™ Dual Display Small Object Counter www.bannerengineering.com - Tel: +1-763-544-3164