The PFC500 products of the PerFormanCe Power series combine high performance midrange power with high power density (4.4 watts/in3), active Power Factor Correction (PFC) and high reliability to meet the requirements of commercial and industrial systems. Providing tightly regulated DC power, the PFC500 is delivers full output performance with only 300 Linear Feet per Minute (LFM) forced air cooling (factory installed fan optional). Other features include remote sense, power fail, logic level inhibit, DC power good. Main channel current sharing is provided for redundant applications. The PFC500 is available with SAE mountings or optional metric mountings. The PFC500 product line is approved to the latest international regulatory standards, and displays the CE Mark.

FEATURES

  • Power Factor Correction (PFC) Meets EN61000-3-2
  • Fully Regulated Outputs
  • Remote Sense
  • Current Share, Power Fail, and Power Good Signals
  • Overtemperature, Overvoltage, and Overcurrent Protected
  • Available with Metric or SAE Mountings
  • Input Transient & ESD Compliance to EN61000-4-2/-3/-4/-5
  • Fan Output Voltage and Optional Fan
  • Optional Isolation Diodes for Parallel or Redundant Operation INPUT SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC Input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-Up Time Over full AC input voltage range at full rated load. 20 mS Input Current 85 VAC at full rated load. 7.8 A RMS Input Protection Non-user serviceable internally located AC input line fuse, F10A, 250V. Inrush Surge Current Internally limited by thermistor, one cycle, 25°C. 110 VAC 35 APK

220 VAC 65

Power Factor Per EN61000-3-2. 0.98 W/VA Operating Frequency Switching frequency of main transformer. 100 kHz SINGLE OUTPUT MODEL SELECTION CHART MODEL OUTPUT ADJUSTMENT MAXIMUM OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION (NOTE 3) %p-p (NOTE 2) ACCURACY NOTES: 1) Output currents ratings are expressed with 300 LFM forced air. 2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 3) Remote sense connected. Rev. 04/2000

PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full rated load, 110 VAC. Varies with distribution of loads among outputs. 75 % Minimum loads PFC500-1024 0.6 PFC500-1028 0.6 Amps PFC500-1048 1.2 Ripple and Noise Full load, 20MHz bandwidth. See Model Selection Charts Output Power 300 LFM forced air cooling required for operation. See optional fan. 500 Watts Continuous power, multiple output models. Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 V Regulation Without connection of remote sense. PFC500-1024 0.8 PFC500-1028 0.7 % PFC500-1048 1.0 Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 1m S3% max. deviation. (Main output of multi-output units). Turn-on Delay Time required for initial output voltage stabilization. 1 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 10 mS INTERFACE SIGNALS AND INTERNAL PROTECTION PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection PFC500-1024 27.0 30.7 PFC500-1028 32.0 35.0 V PFC500-1048 60.0 70.0 Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condi tion. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Remote Sense Total voltage compensation for cable losses with respect to the main output. 250 mV Current Share Accuracy of shared current with up to 6 parallel units. 10 % Inhibit TTL compatible logic signal will inhibit outputs by the application of a logic low signal. An open circuit or external TTL high signal allows normal operation. Input Power TTL compatible logic signal. Time before regulation dropout due to 4m SFail Warning loss of input power at 110 VAC. Power Good TTL compatible signal. Signal is low if main output is greater PFC500-1024 22.08 27.36 or less than 10% of nominal. PFC500-1028 25.20 30.80 V PFC500-1048 44.20 54.72 Fan Voltage Provides 170mA current to user supplied fan if fan option is not selected. 12 V SAFETY, REGULATORY, AND EMI SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. CSA 22.2 NO. 234/950. Approved EN60950 (TÜV). Dielectric Withstand Voltage Input to output. 2600 VDC Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - Conducted. B Class EN55022 / CISPR 22 Conducted. B ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 4. ±4 kV Input Transient Protection Per EN61000-4-5 class 3. Line to Line 1 kVLine to Ground 2 Insulation Resistance Input to output. 10 M Ω Leakage Current Per EN60950, 264 VAC. 2.0 mA

ENVIRONMENTAL SPECIFICATIONS PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating. 10k ASL Ft. Non-Operating. 40k ASL Ft. Operating Temperature At 100% load 0 50 °C Derate linearly above 50°C by 2.5% per °C. At 50% load 0 70 °C Storage Temperature -55 85 °C Forced Air Cooling Forced air cooling of 300 LFM is required if the internal fan is not specified. Cooling air velocity is measured 1/4" above, at the middle of the chassis. Airflow direction is from the input section to the output section. Temperature Coefficient 0°C to 70°C (after 15 minute warm-up). ±0.02 ±0.05 %/°C Relative Humidity Non-Condensing. 5 95 %RH Shock Operating: 10±3mSec, 3 axis, Half Sine. 20 G Non-operating: 10±3mSec, 3 axis, Half Sine. 40 Vibration Operating: 5-32Hz 0.02 in (DA) 32-2000Hz Sinusoidal 1 G PK Non-operating: 6.15 G RMS OPTIONS DESCRIPTION NOTES SIZE IMPACT Isolation Diodes Add “D” as a suffix to the model number to order factory installed isolation diodes N/Afor parallel or redundant operation. Fan Add “F” as a suffix to the model number to order integral fan. 10.50" x 5.00" x 2.50" (provides required 300 LFM of forced air cooling). (266.7mm x 127.0mm x 63.5mm) Metric Mounting Add “M” as a suffix to the model number to order chassis with N/AM4 x 0.7 mounting inserts. www.power-one.comwww.power-one.com For the Most Up-To-Date Information

24 Hours/Day—7 Days/Week

NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems , equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. Specifications are subject to change without notice.

OVERALL LENGTH WITH FAN: 10.50" (266.7mm) WEIGHT: 4.3 LBS (1.95 kg) INPUT & OUTPUT CONNECTIONS: 6-32 SCREW TERMINAL ON 0.375" (9.5mm) CENTERS CHASSIS: 0.090" (2.3mm) ALUMINUM ALLOY, WITH CLEAR FINISH FAN OPTION 3.900" (99.1mm) 0.70" (17.8mm) 5.00" (127.0mm) 2.50" (63.5mm) 1.20" (30.4mm) 1.50" (38.1mm) (31.8mm) 9.00" (228.6mm) SUGGESTED AIR FLOW (BOTTOM VIEW) J3J4 PIN 4 N/C PIN 3 PWR GOOD PIN 2 PF PIN 1 SIG GND PIN 4 +FAN FAN OPTION CHASSIS GND AC-N AC-L TB1 Customer connection: P4,P3,P5 Mating Housing: Molex 5051, 5102, or Equiv. P4,P3,P5 Mating Terminals: J5 +SHARE N/C PIN 1 +SENSE PIN 2 —SENSE PIN 3 INHIBIT +V1 -V1/RTN TB2 V1 ADJ Molex 4809 or 40445, or Equiv. (TOP VIEW) J4, J3, J5 Molex Series 5048, 0.46mm Square pins on 2.50mm centers. 8-32 FLUSH NUT 8 PLACES BOTH SIDES TYP. WITH METRIC MOUNTING OPTION: M4 X 0.7, 8 PLACES 3.12" (79.2mm)