+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 866 513 2839 © 2015 Bel Power Solutions, Inc. BCD.00595_AB The PFC500 products of the PerFormanCe Power Series combine high performance midrange power with high power density (4.4 watts/in 3) and high reliability to meet the requirements of communications, commercial, and industrial systems. Providing tightly regulated DC power, the PFC500 delivers full output performance with only 300 Linear Feet per Minute (LFM) forced -air cooling (factory-installed fan optional). Main channel current sha ring is provided for redundant applications. Units are available with SAE mountings or optional metric mountings. The PFC500 product line is approved to the latest international regulatory standards, and displays the CE Mark.  RoHS Compliant  Power Factor Correction meets EN61000-3-2 (AC input versions)  Fully-regulated outputs  Remote sense  Logic level Inhibit  Current Share, Power Fail, and Power Good Signals  Overtemperature, overvoltage, and overcurrent protected  Available with metric or SAE mountings  Input transient & ESD compliance to EN61000-4-2/-3/-4/-5  Fan output voltage and optional fan  Optional isolation diodes for parallel or redundant operation  DC input versions (36-75 VDC)

tech.support@psbel.com MODEL5 OUTPUT VOLTAGE ADJUSTMENT RANGE MAX. OUTPUT CURRENT2 LINE REGULATION LOAD REGULATION3 RIPPLE & NOISE % p-p4 INITIAL SETTING ACCURACY NOTES: 1 Consult factory for availability of 28V and 48V units with DC input. 2 Output currents ratings are expressed with 300 LFM forced air. 3 Remote sense connected. See Application Note #P1 for load regulation when using the D option for 24V units. 4 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. For ripple/noise on “D” option models, see options data.

5 Models without suffix G use the lead solder exemption

PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC Input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-Up Time Over full AC input voltage range at full rated load. 20 ms Input Current 85 VAC at full rated load. 7.8 ARMS Input Protection Non-user serviceable internally located AC input line fuse, F10A, 250 V. Inrush Surge Current Internally limited by thermistor, one cycle, 25°C. 110 VAC

220 VAC 35

65 APK

Power Factor Per EN61000-3-2. 0.98 W/VA Operating Frequency Switching frequency of main transformer. 100 kHz PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Efficiency Full rated load, 110 VAC. 75 % Minimum loads PFC500-1024G PFC500-1028G PFC500-1048G 0.6 0.6 1.2 Amps Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Charts Output Power 300 LFM forced air cooling required for operation. See optional fan. Continuous power, multiple output models. 500 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 V Regulation Without connection of remote sense. PFC500-1024G PFC500-1028G PFC500-1048G 0.8 0.7 1.0 Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 3% max. deviation. 1 ms Turn-on Delay Time required for initial output voltage stabilization. 1 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 10 ms

tech.support@psbel.com PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection PFC500-1024G PFC500-1028G PFC500-1048G 27.0 32.0 60.0 30.7 35.0 70.0 V Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Remote Sense Total voltage compensation for cable losses with respect to the main output. 250 mV Current Share Accuracy of shared current with up to 6 parallel units. 10 % Inhibit TTL compatible logic signal will inhibit outputs by the application of a logic low signal. An open circuit or external TTL high signal allows normal operation. Input Power Fail Warning TTL compatible logic signal. Time before regulation dropout due to loss of input power at 110 VAC. 4 ms Power Good TTL compatible signal. Signal is low if main output is greater or less than 10% of nominal. For models without the “D” option, internal pull-up resistor is 1k> For “D” option, pull-up resistor is 475. See Apps Note #P1 for details. PFC500-1024G PFC500-1028G PFC500-1048G 22.08 25.20 44.20 27.36 30.80 54.72 V Fan Voltage Provides 170 mA current to user supplied fan if fan option is not selected. 12 V PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Agency Approvals Approved to the latest edition of the following standards. UL/CSA60950-1, EN60950-1 and IEC60950-1 Approved Dielectric Withstand Meets reinforced insulation of IEC60950. Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. B B Class ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 4. ±4 kV Input Transient Protection Per EN61000-4-5 class 3. Line to Line Line to Ground 2 kV Insulation Resistance Input to output. 10 M Leakage Current Per EN60950, 264 VAC. 2.0 mA

tech.support@psbel.com PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Altitude Operating. Non-Operating. 10k 40k ASL Ft. Operating Temperature Derate linearly above 50°C by 2.5% per °C. At 100% load At 50% load 0 50 70 °C Storage Temperature -55 85 °C Forced Air Cooling Forced air cooling of 300 LFM is required if the internal fan is not specified. Cooling air velocity is measured at the output exiting window (2.5” x 5”). Airflow direction is from the input section to the output section. Temperature Coefficient 0°C to 70°C (after 15 minute warm-up). ±0.02 ±0.05 %/°C Relative Humidity Non-Condensing. 5 95 %RH Shock Operating: 10±3mSec, 3 axis, Half Sine. Non-operating: 10±3mSec, 3 axis, Half Sine. 20 40 G Vibration Operating: 5-32 Hz 32-2000 Hz Sinusoidal Non-operating: 0.02 6.15 in (DA) GPK GRMS PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Dimensions Overall Size 228.6 x 127.0 x 63.5 9.00 x 5.00 x 2.50 mm in Overall Length With Fan 266.7 10.50 mm in Weight 1.95 4.3 kg lb PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Isolation Diodes Add “D” as a suffix to the model number to order factory installed isolation diodes for parallel or redundant operation. For 24V models with the “D” option, external caps are required to meet the 1% noise/ripple spec. Power Good has a pull-up resistor of 475 on the 24V models. See Application Note #P1 for details. N/A Fan Add “F” as a suffix to the model number to order integral fan. Fan provides the required 300 LFM of forced air cooling, or otherwise provided by the end user. 266.7 x 127.0 x 63.5 10.50 x 5.00 x 2.50 mm in Metric Mounting Add “M” as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. N/A

*Airflow should be measured at the exiting window (5” x 2.5”). Figure 1. Mechanical Drawing PFC500 equipment used in hazardous environments, or nuclear control systems. the date manufactured. Specifications are subject to change without notice.