The PerFormanCe Power PFC250 Series combines Power Factor Correction (PFC) with wide-range outputs to meet the requirements of data communications and industrial controls. The PFC250-4530G and PFC250-4350G provide high current +3.3 V and +5 V on a single platform to support mixed-mode, high-speed digital circuitry. Bel Power Solutions unique dual-converter architecture combines high reliability with exceptional regulation. All models feature remote sense on outputs V1 and V2 to provide independent compensation of output cable losses. Other standard features include independent current sharing on V1 and V2, thermal shutdown, and remote inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of 3.0 watts per cubic inch. The PerF ormanCe Power PFC250 meets international safety requirements and is CE Marked to the Low Voltage Directive.
- RoHS Compliant
- Greater than 1 million hours demonstrated MTBF
- Active Power Factor Correction (PFC) meets EN61000-3-2
- Dual main outputs provide 3.3 V and 5 V for mixed-mode applications
- Single-wire current sense on outputs V1 and V2
- Remote sense on outputs V1 and V2
- Overtemperature, overload, and overvoltage protection
- Available with metric or SAE mountings
- Isolated V3 and V4 can be used as positive or negative outputs
2 PFC250 Series
tech.support@psbel.com MODEL3 OUTPUT VOLTAGE ADJUSTMENT RANGE MAX. OUTPUT CURRENT 1 LINE REGULATION LOAD REGULATION RIPPLE & NOISE % p-p2 INITIAL SETTING ACCURACY NOTES: 1 Output currents ratings are expressed with 300 LFM forced air. 2 Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3 Models without suffix G use the lead solder exemption
250 W with 300 LFM Forced-Air Cooling. Isolated V3 and V4 can be used as Positive or Negative Outputs MODEL5 OUTPUT VOLTAGE ADJUSTMENT RANGE OUTPUT CURRENT LINE REGULATION LOAD REGULATION RIPPLE & NOISE % p-p1 INITIAL SETTING ACCURACY PFC250-4000G2 PFC250-4001G2,4 PFC250-4004G3, 4 PFC250-4350G2, 4 PFC250-4530G 2, 4
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2019 Bel Power Solutions & Protection BCD.00593_AC NOTES: 1 Maximum peak-to-peak expressed as a percentage of output voltage, 20 MHz bandwidth. 2 Total current available from V1 + V2 is 40 amperes, total current available from V3 + V4 is 6.6 amperes. 3 Total current available from V1 + V2 is 40 amperes, total current available from V3 + V4 is 6.0 amperes. 4 One adjustment pot is provided for both V3 and V4 outputs. One-to-one tracking is provided on V3 and V4 when equally loaded.
5 Models without suffix G use the lead solder exemption
Ooo Model numbers highlighted in yellow are not recommended for new designs or EOL. PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC Input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 80 VAC Hold-up Time After last AC line peak at 250 watts. 20 ms Input Current 85 VAC at full rated load. 4.5 ARMS Input Protection Non-user serviceable internally located AC input line fuse. Inrush Surge Current Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C. 35 APK Power Factor Per EN61000-3-2. 0.95 W/VA Operating Frequency Switching frequency of main output transformer. Switching frequency of secondary transformer. Switching frequency of Power Factor Correction circuit. 129 kHz PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Efficiency Full rated load, 110 VAC. Varies with distribution of loads among outputs. 65 75 % Minimum Load, V1 Min. load required to maintain regulation on V2 Single output models All other models
4 Amps
Minimum Load, V3 Min. load required to maintain regulation on V4 Single output models PFC250-4000G All other models N/A 1.25 0.6 Amps Ripple and Noise Full load, 20 MHz bandwidth. See Model Selections Output Power 300 LFM forced-air cooling. 250 Watts Overshoot /Undershoot Output voltage overshoot/undershoot at turn-on. 0 % Regulation Varies by output. Total regulation includes: line changes over the specified input range, changes in load starting at 20% load and changing to 100% load. See Model Selections Transient Response Recovery time to within 1% of initial set point due to a 25% step load from any load setting from minimum to maximum load. 500 µs Turn-on Delay Time required for initial output voltage stabilization. 2 s Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 20 ms
4 PFC250 Series
tech.support@psbel.com PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Latch style overvoltage protection. Available on all single output models and V1, V2, and V3 on all multiple-output models. 3.3V output, V1 3.3V output, V2 5V output, V1, V2 12V output, V1, V2 15V output, V1 24V output, V1 48V output, V1 4.1 4.2 6.0 14.0 18.3 27.0 60.0 4.65 4.2 6.4 16.0 19.8 30.7 70.0 V Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Output Good TTL compatible signal. Signal is high when V1 output is within 5% of nominal. Signal shall remain low for 20 milliseconds following loss of Output Good. 3.3 V 5 V 3.16 4.75 V Input Power Fail Warning TTL compatible logic signal. Time before regulation dropout due to loss of input power. May be used as independent PSOK signal in redundant applications. 5 ms Current Share Accuracy of shared current with up to 6 parallel units. Single-wire current share on V1 and V2 with return via negative (-) Sense return. Minimum current share load is 6 A or 50 W, whichever is smaller. 10 % Remote Sense Available on V1 and V2. Total voltage compensation for cable losses with respect to the main output. 250 mV Inhibit Output voltage is inhibited by application of external high (5 V) signal. Standby Power Available with fan option versions only (+5 VDC). 100 mA PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Agency Approvals Approved to the latest edition of the following standards. UL/CSA60950-1, EN60950-1 and IEC60950-1 Approved Dielectric Withstand Voltage Input to Output per EN60950. 2600 VDC Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - Conducted. EN55022 / CISPR 22 Conducted. B B Class ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst Per EN61000-4-4, level 4. ± 4 kV Input Transient Protection Per EN61000-4-5 level 3. Line-to-Line Line-to-Ground 2 kV Insulation Resistance Input-to-Output. 10 MΩ Leakage Current Per EN60950, 264 VAC. 1500 µA
+86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2019 Bel Power Solutions & Protection BCD.00593_AC PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Altitude Operating. Non-Operating. 10k 40k ASL Ft. Operating Temperature Derate linearly above 50°C by 2.5% per °C. At 100% load: At 50% load: 70 °C Storage Temperature -55 85 °C Temperature Coefficient 0°C to 70°C (after 15 minute warmup). ± 0.02 ± 0.05 %/°C Relative Humidity Non-Condensing. 5 95 %RH Shock Peak acceleration. 20 GPK Vibration Random vibration, 10 Hz to 2 kHz, 3 axes. 6 GRMS PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Dimensions Overall Size 215.9 x 120.7 x 50.8 8.50 x 4.75 x 2.00 mm in Overall Length With Fan 250.4 10.00 mm in Weight 1.12 2.75 kg lb PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Metric Mounting Add “M” as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. 215.9 x 120.7 x 50.8 8.50 x 4.75 x 2.00 mm in Fan Add “F” as a suffix to the model number to order integral fan. 250.4 x 120.7 x 63.5 10.00 x 4.75 x 2.50 mm in CONNECTOR MOLEX SERIES HOUSING PIN SERIES PINS (LOOSE) PINS (CHAIN) WIRE GAUGE 41695 09-50-8051 6838 08-50-0189 08-50-0187 18-20 AWG 41695 09-50-8051 2478 08-50-0106 08-50-0105 18-20 AWG 2139 09-50-3051 2478 08-50-0106 08-50-0105 18-20 AWG 41695 09-50-8061 6838 08-50-0189 08-50-0187 18-20 AWG 41695 09-50-8061 2478 08-50-0106 08-50-0105 18-20 AWG 2139 09-50-3061 2478 08-50-0106 08-50-0105 18-20 AWG J6 * 5264-N 50-37-5113 5263 08-70-1040 08-70-1039 22-28 AWG NOTE: * The +5V @ 100mA standby power output (J6-11) is available only on units with the fan option.
6 PFC250 Series
Figure 1. Mechanical Drawing PFC250 equipment used in hazardous environments, or nuclear control systems. the date manufactured. Specifications are subject to change without notice.