1008 to 1512W Power Factor Correction Module PF1500B-360 Series 1 Features Benefits The full brick size PF1500B-360 converts AC to a regulated 360Vdc for use in distributed power systems utilizing isolated high voltage DC-DC converters, or loads requiring a high voltage source. Rated at 1512W for an input of 170 to 265V and 1008W from 85 to 265V, the module has a 0.98 power factor and an efficiency of up to 96.5%. The baseplate can be conduction cooled via a cold-plate or using an optional heatsink and external airflow. Modules can be connected in parallel for additional power. The remote on/off function can be used to enable DC-DC converters via the ENA (DC good) signal. An auxiliary output and inverter good signal are also provided for control and monitoring.
- Suitable For Developing Custom Supplies
- Up to 96.5% Efficient
- Compact Full Brick Package (116.8 x 61 x 12.7mm)
- Up to 100°C Rated Baseplate Temperature
- Conduction Cooled Via Baseplate
- Module Solution Reduces Risk, Time and Cost
- Less Waste Heat to Manage and Reduced AC Power Consumption
- Utilizes Less Space
- Suitable for Rugged Environments
- For Use in Convection Cooled or Sealed Enclosures https://product.tdk.com/en/power/pf-b www.emea.lambda.tdk.com/pf Model Selector Output Maximum Maximum Maximum Maximum Model Voltage Current (A) Power (W) Current (A) Power (W) (V) 85-265Vac Input 85-265Vac Input 170-265Vac Input 170-265Vac Input PF1500B-360 360 2.8 1008 4.2 1512
Related Products
Type Part Number(s) Size (mm) / Description Heatsink HAF-10L 116.8 x 25.4 x 61 Heatsink HAF-15L 116.8 x 38.1 x 61 Heatsink HAF-15T 116.8 x 38.1 x 61 DC-DC Converters PH-A series 50 to 1200W, 200-425V input Thermal Fuse Resistor for Inrush Circuit DFN51120 5.1R 5W (For TRF1 and TRF2) Blank M3 Threaded mounting hole /T Non threaded mounting holes
Input Voltage Range (Operating) Vac 85 - 265V Nominal Input Voltage Range Vac 100 - 240 (Note: Safety certified for 90 - 264Vac only) Input Frequency Hz 47 - 63 Input Current (100 / 230Vac) A 10.6 / 6.8 Inrush Current at 230Vac (typ) (Cold Start) A 25 Leakage Current - External circuitry - See Instruction Manual Power Factor - >0.98 Harmonic Compliance - Meets IEC61000-3-2 Hold Up Time - External circuitry - See Instruction Manual Efficiency % 100Vac: 93.5; 115Vac: 94, 230Vac: 96.5 Conducted & Radiated EMI - External circuitry - See Evaluation Data on website for EN55032 class A/B circuitry Immunity - See website for Immunity report Safety Certifications and Markings - IEC/UL/CSA/EN62368-1, CE Mark and UKCA Mark Output Output Voltage Tolerance % ±2 Output Voltage Adjustment - Fixed output voltage Switching Frequency kHz 127 Line Regulation V 5 Load Regulation V 10 External Load Capacitance uF 470 to 2,700 (See instruction manual) Ripple & Noise (Peak to Peak) V 20 Temperature Coefficient %/°C 0.02 Minimum Load - No minimum load required Overcurrent Protection - External fuse (See instruction manual) Overvoltage Protection V 390 - 425 Overtemperature Protection °C 105 - 130 Remote Sense - No Remote On/Off - Closed contact = output “on” Power ON (ENA Signal) - Open collector, low when output voltage is >350V IOG (Inverter Operation Good) - Opto-isolated signal, low when inverter is good Auxiliary Voltage V / mA 10 - 16V 10mA Indicators - None Parallel Operation - Up to 3 modules Environmental Operating Temperature °C -40 to +100 (Baseplate), -40 to +85 (Ambient) Storage Temperature °C -40 to +100 Humidity (non condensing) %RH 20 - 95 Operating, 10 - 95 Storage Cooling - Conduction Altitude m 3,000 Withstand Voltage (For 1 minute) Vac Terminal pins to baseplate 2,500. (Input is not isolated from the output) Isolation Resistance MΩ >100 at 25°C, 70%RH & 500Vdc Vibration (Non-operating) - 10-55Hz (Sweep for 1min.) Amplitude 0.825mm constant (maximum 49m/s2) X, Y, Z 1 hour each Shock (In Package) - Less than 196.1m/s2 Other Weight (Typ) g 200 Size (LxWxH) mm 116.8 x 61 x 12.7 Size (LxWxH) Inches 4.6 x 2.4 x 0.5 MTBF - Telcordia SR-332 issue 5* Hours 866,521 Warranty Years 5 Notes See website for detailed specifications, test methods and installation manual *80°C baseplate, full load, 230Vac input
PF1500B-360 Basic connection Derating Curve Input Voltage vs. Output Power
Outline Drawing & Pin Out Block Diagram
PF1500B-360 260955 October 11th, 2022 V1 PF1500B-360 Series 5 TDK-Lambda France SAS TDK-Lambda Americas TDK Electronics do Brasil Ltda T el: +33 1 60 12 71 65 tlf.fr.powersolutions@tdk.com www.emea.lambda.tdk.com/fr Tel: +55 11 3289-9599 sales.br@tdk-electronics.tdk.com www.tdk-electronics.tdk.com/en Tel: +1 800-LAMBDA-4 or 1-800-526-2324 tla.powersolutions@tdk.com www.us.lambda.tdk.com Italy Sales Office T el: +39 02 61 29 38 63 tlf.it.powersolutions@tdk.com www.emea.lambda.tdk.com/it Netherlands tlf.nl.powersolutions@tdk.com www.emea.lambda.tdk.com/nl TDK-Lambda Germany GmbH T el: +49 7841 666 0 tlg.powersolutions@tdk.com www.emea.lambda.tdk.com/de Austria Sales Office T el: +43 2256 655 84 tlg.at.powersolutions@tdk.com www.emea.lambda.tdk.com/at Switzerland Sales Office T el: +41 44 850 53 53 tlg.ch.powersolutions@tdk.com www.emea.lambda.tdk.com/ch Nordic Sales Office T el: +45 8853 8086 tlg.dk.powersolutions@tdk.com www.emea.lambda.tdk.com/dk TDK-Lambda UK Ltd . T el: +44 (0) 12 71 85 66 66 tlu.powersolutions@tdk.com www.emea.lambda.tdk.com/uk TDK-Lambda Ltd. T el: +9 723 902 4333 tli.powersolutions@tdk.com www.emea.lambda.tdk.com/il-en TDK-Lambda Corporation Tel: +81-3-6778-1113 www.jp.lambda.tdk.com TDK-Lambda Singapore Pte Ltd. Tel: +65 6251 7211 tls.marketing@tdk.com www.sg.lambda.tdk.com TDK-Lambda (China) Electronics Co. Ltd . Tel: +86 21 6485-0777 tlc.powersolutions@tdk.com www.lambda.tdk.com.cn TDK India Private Limited, Power Supply Division Tel: +91 80 4039-0660 mathew.philip@tdk.com www.sg.lambda.tdk.com For Additional Information, please visit https://product.tdk.com/en/power/