308 Constitution Drive
Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com ESD Protector Overvoltage Protection Device Raychem Circuit Protection Products PRODUCT: PESD1206Q-140 DOCUMENT: SCD 26108 REV LETTER: I REV DATE: DECEMBER 7, 2007 PAGE NO.: 1 OF 6 Specification Status: Released MATERIALS INFORMATION ROHS Compliant ELV Compliant PART NUMBERING PESD 1206 Q - 140 Series Operating Voltage Designator 14 x 100 = 14VDC EIA Size Q: Array of 4 elements The operating voltage is used to measure leakage current @ 1s BENEFITS
- Suitable for high speed data transmission applications
- Board space savings
- Help to protect sensitive electronic circuits against damage from electrostatic discharge (ESD) events
- Assist equipment to pass IEC 61000-4-2, level 4 testing
FEATURES
- Thick film technology
- Low capacitance (0.25 pF typical)
- Low clamping voltage
- Capable of withstanding numerous ESD strikes
- Compatible with standard reflow installation procedures
- Bi-directional protection
APPLICATIONS
- Cellular Phones Caution: This part is not intended to be used under bias, nor for application with a power bus. Not to be used for new designs. For new design please contact Tyco Electronics Sales
Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com ESD Protector Overvoltage Protection Device Raychem Circuit Protection Products PRODUCT: PESD1206Q-140 DOCUMENT: SCD 26108 REV LETTER: I REV DATE: DECEMBER 7, 2007 PAGE NO.: 2 OF 6 TYPICAL DEVICE RATINGS AND CHARACTERISTICS Typical IEC Trigger Voltage1 Typical IEC Clamping Voltage1 after 30ns Typical TLP Trigger Voltage2 Typical TLP Clamping Voltage2 after 30ns Typical TLP Clamping Voltage2 after 60ns Typical Capacitance @ 1 MHz, 1Vrms VT(IEC) V C(IEC) V T(TLP) V C(TLP 30) V C(TLP 60) Cp V V V V V pF Symbol Unit Value 350 30 320 75 65 0.25 Note 1: IEC61000-4-2, level 4, 8kV contact test method Note 2: TLP test method at 1000V (refer to graph on next page) Note 3: PESD0603-140 can be used only in application without DC bias GENERAL CHARACTERISTICS Storage temperature: -55°C … +110°C Storage temperature: -40°C … + 85°C ESD voltage capability (tested per IEC 61000-4-2) o Contact discharge mode: typical 8kV, max 15kV o Air discharge mode: typical 15kV, max 25kV ESD pulse withstand: Minimum 1,000 pulses (tested per IEC 61000-4-2, level 4, contact method) Environmental Specifications Thermal Shock Heat Storage Test Solderability Solder Heat Vibration Mechanical Shock Solvent Resistance Test Conditions -55 o C to 125ºC 30min dwell 1000 cycles 110 o 1000hours 230 o C±5 o C 3±1s, 95% coverage 260 o 10s 10 to 50Hz,60s cycle, 2hrs each in X-Y-Z axis 1500G, 0.5ms, X-Y- Z axis, 3 times IPA ultrasonic 300s Pass/Fail Criteria IL≤10µA I L≤10µA I L≤10µA I L≤10µA I L≤10µA I L≤10µA I L≤10µA
Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com ESD Protector Overvoltage Protection Device Raychem Circuit Protection Products PRODUCT: PESD1206Q-140 DOCUMENT: SCD 26108 REV LETTER: I REV DATE: DECEMBER 7, 2007 PAGE NO.: 3 OF 6 MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX Width E Width FLength A Height B End Terminal Width C Width D VW X Y Z Ref Ref Ref Ref Ref DIMENSIONS Drawing Not To Scale *Rounded off approximation RECOMMENDED LAND PATTERN: Solder thickness 0.15 to 0.2mm *Rounded off approximation. V W Z Y x D A B C E F
Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com ESD Protector Overvoltage Protection Device Raychem Circuit Protection Products PRODUCT: PESD1206Q-140 DOCUMENT: SCD 26108 REV LETTER: I REV DATE: DECEMBER 7, 2007 PAGE NO.: 4 OF 6 SOLDER REFLOW RECOMMENDATIONS: A Temperature ramp up 1 From ambient to Preheating temperature 30s to 60s B Preheating 140°C - 160°C 60s to 120s C Temperature ramp up 2 From Preheating to Main heating temperature 20s to 40s at 200°C 60s ~ 70s D at 220°C 50s ~ 60s at 240°C 30s ~ 40s Main heating at 260°C 5s ~ 10s E Cooling From main heating temperature to 100°C max 4°C/s
Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com ESD Protector Overvoltage Protection Device Raychem Circuit Protection Products PRODUCT: PESD1206Q-140 DOCUMENT: SCD 26108 REV LETTER: I REV DATE: DECEMBER 7, 2007 PAGE NO.: 5 OF 6 PACKAGING Packaging Tape & Reel Standard Box PESD1206Q-140 5,000 25,000 EIA referenced Reel Dimensions for PESD Devices Reel Dimensions (mm): Carrier Dimensions (mm): Product Orientation – always face up (meaning the substrate is at the bottom), but parts do not have polarity mark. A B C D E F G A B C D E F L W T1
Menlo Park, CA 94025-1164 Phone: 800-227-4856 www.circuitprotection.com ESD Protector Overvoltage Protection Device Raychem Circuit Protection Products PRODUCT: PESD1206Q-140 DOCUMENT: SCD 26108 REV LETTER: I REV DATE: DECEMBER 7, 2007 PAGE NO.: 6 OF 6 POST REFLOW, CLEANING CONDITIONS A 5% saponofier combined with water during wash. For Ultrasonic process water temperature should be at 50°C and board should be submerged for a minimum of one minute in the solutions, then rinse and dry. For in-line washing, the temperature of the water sp rayed should be at 110°C, rinse and drying is done in-line. Warning: Application Limitations for PESD1206Q-140. This part is not intended to be used under bias, nor for power bus applications. Users should independently evaluate the suitability of and test each product selected for their own applications Information furnished is believed to be accurate and reliable . However, users should independently evaluate the suitability of and test each product selected for their own applications. Tyco Electroni cs reserves the right to change or update, without notice, any information contained in this publication; to change, without notice, the design, cons truction, processing, or specification of any product; and to discontinue or limit production or distribution of any product. This publication supersedes and replaces all i nformation previously supplied. Without expressed or written consent by an officer of Tyco Electronics, Tyco Electronics does not authori ze the use of any of its products as components in nuclear facility applications, aerospace, or in critical life support devices or systems. Tyco Electronics expressly disclaims all implied warranties regard ing the information contained herei n, including, but not limited t o, any implied warranties of merchantability or fitness for a particular purpose. Tyco Electronics’ only obligations are those in the Tyco Electronics Standard Terms and Conditions of Sale and in no ca se will Tyco Electronics be liable for any incidental, indirect, or consequential damages arising from the sale, resale, use, or misuse of its products. © 2004, 2007 Tyco Electronics Corporation. All rights reserved.