cui.com date 08/11/2021 page 1 of 8 SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date page 1 of 8

FEATURES

  • 1 W isolated output
  • smaller package
  • single/dual unregulated outputs
  • 3,000 Vdc isolation
  • short circuit protection
  • extended temperature range (-40~105°C)
  • antistatic protection up to 8kV
  • high efficiency at light load
  • efficiency up to 82%
  • EN 62368-1 MODEL input voltage output voltage output current output power ripple and noise2 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) typ (mVp-p) typ (%) PES1-S3-S3-M 3.3 2.97~3.63 3.3 30 303 1 60 69 PES1-S3-S5-M1 3.3 2.97~3.63 5 20 200 1 60 74 PES1-S5-S3-M1 5 4.5~5.5 3.3 30 303 1 60 72 PES1-S5-S5-M1 5 4.5~5.5 5 20 200 1 60 80 PES1-S5-S9-M1 5 4.5~5.5 9 12 111 1 60 80 PES1-S5-S12-M1 5 4.5~5.5 12 9 84 1 60 80 PES1-S5-S15-M1 5 4.5~5.5 15 7 67 1 60 80 PES1-S5-S24-M1 5 4.5~5.5 24 4 42 1 60 80 PES1-S5-D5-M 5 4.5~5.5 ±5 ±10 ±100 1 60 80 PES1-S5-D9-M 5 4.5~5.5 ±9 ±6 ±56 1 60 80 PES1-S5-D12-M 5 4.5~5.5 ±12 ±5 ±42 1 60 79 PES1-S5-D15-M 5 4.5~5.5 ±15 ±3 ±33 1 60 81 PES1-S5-D24-M 5 4.5~5.5 ±24 ±2 ±21 1 60 81 PES1-S12-S3-M1 12 10.8~13.2 3.3 30 303 1 60 72 PES1-S12-S5-M1 12 10.8~13.2 5 20 200 1 60 80 PES1-S12-S9-M1 12 10.8~13.2 9 12 111 1 60 80 PES1-S12-S12-M1 12 10.8~13.2 12 9 84 1 60 80 PES1-S12-S15-M1 12 10.8~13.2 15 7 67 1 60 80 PES1-S12-D5-M 12 10.8~13.2 ±5 ±10 ±100 1 60 80 PES1-S12-D9-M 12 10.8~13.2 ±9 ±6 ±56 1 60 80 PES1-S12-D12-M 12 10.8~13.2 ±12 ±5 ±42 1 60 81 PES1-S12-D15-M 12 10.8~13.2 ±15 ±3 ±33 1 60 81 PES1-S12-D24-M 12 10.8~13.2 ±24 ±2 ±21 1 60 81 PES1-S15-S15-M 15 13.5~16.5 15 7 67 1 60 80 PES1-S24-S5-M1 24 21.6~26.4 5 20 200 1 60 80 PES1-S24-S9-M1 24 21.6~26.4 9 12 111 1 60 80 PES1-S24-S15-M1 24 21.6~26.4 15 7 67 1 60 80 Notes: 1. UL approved 2. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output. Additional Resources: Product Page

cui.com CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 08/11/2021 │ page 2 of 8 MODEL (CONTINUED) input voltage output voltage output current output power ripple and noise2 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) typ (mVp-p) typ (%) PES1-S24-S24-M1 24 21.6~26.4 24 4 42 1 60 80 PES1-S24-D5-M 24 21.6~26.4 ±5 ±10 ±100 1 60 80 PES1-S24-D9-M 24 21.6~26.4 ±9 ±6 ±56 1 60 80 PES1-S24-D12-M 24 21.6~26.4 ±12 ±5 ±42 1 60 81 PES1-S24-D15-M 24 21.6~26.4 ±15 ±3 ±33 1 60 82 PES1-S24-D24-M 24 21.6~26.4 ±24 ±2 ±21 1 60 76 Notes: 1. UL approved 2. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output. PART NUMBER KEY INPUT parameter conditions/description min typ max units operating input voltage

3.3 Vdc input models

5 Vdc input models

12 Vdc input models

15 Vdc input models

24 Vdc input models

2.97 4.5 10.8 13.5 21.6 3.3 3.63 5.5 13.2 16.5 26.4 Vdc Vdc Vdc Vdc Vdc surge voltage for maximum of 1 second -0.7 -0.7 -0.7 -0.7 -0.7 Vdc Vdc Vdc Vdc Vdc filter capacitance filter OUTPUT parameter conditions/description min typ max units line regulation for Vin change of 1%

3.3 Vdc output models

±1.5 ±1.2 load regulation measured from 10% load to full load

5 Vdc output models

9 Vdc output models

12 Vdc output models

15 Vdc output models

24 Vdc output models

voltage accuracy see tolerance envelope curve switching frequency 100% load, nominal input voltage 100 kHz temperature coefficient 100% load ±0.03 %/°C PES1 - SXX - XXX - M - X Input Voltage Output Voltage Packaging StyleBase Number Output S = single D = dual "blank" = tube TR = tape & reel Additional Resources: Product Page

cui.com CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 08/11/2021 │ page 3 of 8 PROTECTIONS parameter conditions/description min typ max units short circuit protection PES1-S5-S24-M, PES1-S5-D24-M and all 24 V input models1 all other models: continuous, automatic recovery 1 s Note: 1. If maximum protection time is exceeded input power must me cycled to restart device. SAFETY AND COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute at 1 mA max. 3,000 Vdc isolation resistance input to output at 500 Vdc 1,000 MΩ safety approvals2 certified to 62368-1: EN certified to 60950-1: UL conducted emissions CISPR22/EN55022 class B (external circuit required, see Figure 1) radiated emissions CISPR22/EN55022 class B (external circuit required, see Figure 1) ESD IEC/EN61000-4-2, class B, contact ± 8kV for single outputs IEC/EN61000-4-2, class B, contact ± 6kV for dual outputs MTBF as per MIL-HDBK-217F @ 25°C 3,500,000 hours RoHS 2011/65/EU Note: 2. See specific models noted on page 1 & 2. ENVIRONMENTAL parameter conditions/description min typ max units operating temperature see derating curve -40 105 °C storage temperature -55 125 °C storage humidity non-condensing 95 % temperature rise at full load, Ta = 25°C 25 °C SOLDERABILITY parameter conditions/description min typ max units hand soldering 1.5 mm from case for 10 seconds 300 °C reflow soldering see reflow soldering profile 245 °C Additional Resources: Product Page

cui.com CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 08/11/2021 │ page 4 of 8 4UZK -XOJSS A C A C dq AC$$ AC rArC A C ,XUTZ<OK] :UV<OK] 8OMNZ<OK] :UV<OK] AC AC AC AC AC A C AC AC A C PIN CONNECTIONS PIN Function

1 GND

2 Vin

units: mm[inch] tolerance: ±0.25[±0.010] pin section tolerance: ±0.10[±0.004] MECHANICAL parameter conditions/description min typ max units dimensions single output models: 12.70 x 8.30 x 7.25 dual output models: 15.24 x 8.30 x 7.25 mm mm case material epoxy resin (UL94-V0) weight single output models dual output models 1.6 2.0 g g MECHANICAL DRAWING SINGLE OUTPUT MODELS NC: No Connection Additional Resources: Product Page

cui.com CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 08/11/2021 │ page 5 of 8 PIN CONNECTIONS PIN Function units: mm[inch] tolerance: ±0.25[±0.010] pin section tolerance: ±0.10[±0.004] MECHANICAL DRAWING (CONTINUED) DUAL OUTPUT MODELS NC: No Connection 10.16 [0.400] 0.88 [0.035] 0.25 [0.010] 11.20 [0.441] 8.30 [0.327] 2.54 [0.100] 0.60 [0.024] 0.10 7.25 [0.285] 7.00 [0.276] 1 5 710 2 4 1.00 [0.039] 2.54 [0.100] 2.10 [0.083] 12.20 [0.480] 10.16 [0.400] Top View Front View Right View Top View Note: Grid 2.54*2.54mm Additional Resources: Product Page

cui.com CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 08/11/2021 │ page 6 of 8 DERATING CURVES EMC RECOMMENDED CIRCUIT Recommended external circuit components Vin (Vdc) C1 LDM 3.3 4.7μF/50V 6.8μH 5 4.7μF/50V 6.8μH 12 4.7μF/50V 6.8μH 15 4.7μF/50V 6.8μH 24 4.7μF/50V 6.8μH Figure 1 Table 1 Single Outputs Dual Outputs Note: 1. See Table 2 for Cout values. 2. CY: 1nF/3kV for 24 Vdc input dual output models, PES1-S5-D24-M, and PES1-S12-D24-M only Additional Resources: Product Page

cui.com CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 08/11/2021 │ page 7 of 8 1. Output load requirement To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load. 2. Overload Protection Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add this is to add a circuit breaker to the circuit. 3. Recommended circuit If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low ESR(see Figure 2 & Table 2). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance must be less than the maximum capacitive load (see Table 3). APPLICATION NOTES Note: 1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed. 2. Max. capacitive load tested at input voltage range and full load. 3. It is recommended to use either ceramic capacitors or electrolytic capacitors on the input and the output. Using tantalum capacitors may increase the risk of failure. 4. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified. Single Vout (Vdc) Max. Capacitive Load (μF) Dual Vout (Vdc) Max. Capacitive Load1 (μF) 3.3 220 -- -- 5 220 5 100 9 220 9 100 12 220 12 100 15 220 15 100 24 220 24 100 Figure 2 Table 2 Vin (Vdc) Cin (µF) Single Vo (Vdc) Cout (µF) Dual Vo (Vdc) Cout (µF) 5 4.7 5 10 ±5 4.7 -- -- 9 4.7 ±9 2.2 12 2.2 12 2.2 ±12 1 15 2.2 15 1 ±15 1 24 1 24 0.47 ±24 0.47 Table 3 Note: 1. For each output. Single Outputs Dual Outputs Additional Resources: Product Page

CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 08/11/2021 │ page 8 of 8 CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com rev. description date 1.0 initial release 03/19/2013 1.01 added models, updated spec 04/04/2014 1.02 added UL approval to some models 10/21/2014 1.03 updated tolerance envelope curves 06/26/2015 1.04 safeties updated in features and safety approvals line 01/18/2021 1.05 derating curves and circuit figures updated, short circuit protection note updated 08/11/2021 The revision history provided is for informational purposes only and is believed to be accurate.

REVISION HISTORY

Additional Resources: Product Page