PES1-M CUI | Alldatasheet

Document overview

  • Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 6

Technical content

cui.com date 03/19/2013 page 1 of 6 SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date page 1 of 6

FEATURES

  • 1 W isolated output
  • smaller package
  • single unregulated output
  • 3,000 Vdc isolation
  • continuous short circuit protection
  • extended temperature range (-40~105°C)
  • antistatic protection up to 8kV
  • high efficiency at light load
  • efficiency up to 81% MODEL input voltage output voltage output current output power ripple and noise1 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) typ (mVp-p) typ (%) PES1-S5-S5-M 5 4.5~5.5 5 20 200 1 30 80 PES1-S5-S9-M 5 4.5~5.5 9 12 111 1 30 80 PES1-S5-S12-M 5 4.5~5.5 12 9 84 1 30 80 PES1-S5-S15-M 5 4.5~5.5 15 7 67 1 60 80 PES1-S5-S24-M 5 4.5~5.5 24 4 42 1 60 80 PES1-S12-S5-M 12 10.8~13.2 5 20 200 1 30 80 PES1-S12-S9-M 12 10.8~13.2 9 12 111 1 30 80 PES1-S12-S12-M 12 10.8~13.2 12 9 84 1 30 81 PES1-S12-S15-M 12 10.8~13.2 15 7 67 1 60 81 PES1-S15-S15-M 15 13.5~16.5 15 7 67 1 60 81 PES1-S24-S5-M 24 21.6~26.4 5 20 200 1 30 80 PES1-S24-S9-M 24 21.6~26.4 9 11 110 1 30 80 PES1-S24-S15-M 24 21.6~26.4 15 7 67 1 60 81 PES1-S24-S24-M 24 21.6~26.4 24 4 42 1 60 81 Notes: 1. ripple and noise are measured at 20 MHz BW by “parallel cable” method

cui.com CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 03/19/2013 │ page 2 of 6 PART NUMBER KEY PES1 - SXX - SXX - M - X Input Voltage Output VoltageBase Number Packaging Style Package Options "blank" = standard INPUT parameter conditions/description min typ max units operating input voltage

5 V input models

12 V input models

15 V input models

24 V input models

4.5 10.8 13.5 21.6 5.5 13.2 16.5 26.4 Vdc Vdc Vdc Vdc surge voltage for maximum of 1 second -0.7 -0.7 -0.7 -0.7 Vdc Vdc Vdc Vdc filter capacitance filter OUTPUT parameter conditions/description min typ max units line regulation for Vin change of 1% ±1.2 % load regulation measured from 10% load to full load 15 % voltage accuracy see tolerance envelope curve switching frequency 100% load, nominal input voltage 100 300 kHz temperature coefficient 100% load ±0.03 %/°C PROTECTIONS parameter conditions/description min typ max units short circuit protection continuous, automatic recovery SAFETY AND COMPLIANCE parameter conditions/description min typ max units isolation voltage for 1 minute at 1 mA max. 3,000 Vdc isolation resistance at 500 Vdc 1,000 MΩ conducted emissions CISPR22/EN55022, class B, (external circuit required) radiated emissions CISPR22/EN55022, class B, (external circuit required) ESD IEC/EN61000-4-2, class B, contact ±8kV MTBF MIL-HDBK-217F @ 25°C 3,500,000 hours RoHS compliant yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature see derating curve -40 105 °C storage temperature -55 125 °C storage humidity non-condensing 95 % temperature rise at full load 25 °C SMT TR = Tape & Reel

cui.com CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 03/19/2013 │ page 3 of 6 0~5° 2.10 [0.083] 0.25 [0.010 ] ± 0.10 ± 0.004 10.20[ 0.402] 1.00[0.039] 7.00 [0.276] 11.20 [0.441 ] ± 0.30 ± 0.012 8.30 [0.327 ] ± 0.20 ± 0.008 12.70± 0.20 [0.500 ]± 0.008 1 24 A A 2.54 [0.100] 7.62 [0.300] 0.60± 0.10 [0.020 ]± 0.004 2.54 [0.100 ] ± 0.20 ± 0.08 7.25 [0.285] 2.25 [0.089] 0.10 9.77 [0.385 ] ± 0.20 ± 0.079 0.88 [0.035 ] ± 0.20 ± 0.008 1.45 [0.057 ] ± 0.20 ± 0.008 2.54 [0.100] 7.62 [0.300] Top View Front View Side View Top View PCB Layout Grid Size: 2.54mm x 2.54mm MECHANICAL parameter conditions/description min typ max units case material epoxy resin (UL94-V0) weight 1.52 g MECHANICAL DRAWING PIN CONNECTIONS PIN Function

1 GND

2 Vin

units: mm[inch] tolerance: ±0.20[±0.010] pin section tolerance: ±0.10[±0.008] parameter conditions/description min typ max units hand soldering 1.5 mm from case for 10 seconds 300 °C reflow soldering see reflow soldering profile 245 °C SOLDERABILITY 100 150 200 250 245 217

60 Max

(>217) Sec Temperature (°C) Time (sec.) Peak Temp 245°C(max.)

cui.com CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 03/19/2013 │ page 4 of 6 EMC RECOMMENDED CIRCUIT Recommended external circuit patterns Vin (Vdc) C1 LDM C2 5 4.7μF/50V 6.8μH NC 12 4.7μF/50V 6.8μH NC 15 4.7μF/50V 6.8μH 470pF/3KV 24 4.7μF/50V 6.8μH 470pF/3KV Vi n GN D +Vo EUT LO AD LD M Vi n GN D TEST CONFIGURATION DCCin Lin DC Load Oscilloscope Current Probe Note: Input reflected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance. DERATING CURVES 100 Ambient Temperature (°C) Load (%) -40- 20 02 04 06 0 80 105 120 Temperature Derating Curve Safe operating area 10010 20 30 40 50 60 70 80 90 100 -10 2.5 7.5 -2.5 -7.5 Typical Load Line Rated Output Voltage 2.5 -2.5 -7.5 Output Current Percentage (%) (Nominal Input Voltage) Tolerance Envelope Curve Output Voltage Accuracy (%) External components Lin 4.7μH Cin 220μF, ESR < 1.0Ω at 100 KHz

CUI Inc │ SERIES: PES1-M │ DESCRIPTION: DC-DC CONVERTER date 03/19/2013 │ page 6 of 6 CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com rev. description date 1.0 initial release 03/19/2013 The revision history provided is for informational purposes only and is believed to be accurate.

REVISION HISTORY