cui.com date 07/06/2021 page 1 of 6 SERIES: PEP1-M │ DESCRIPTION: DC-DC CONVERTER date 07/06/2021 page 1 of 6

FEATURES

  • 1W isolated output
  • 3000 Vdc isolation
  • compact SMD package
  • continuous short circut protection
  • no-load input current as low as 5mA
  • wide temperature range: -40°C to +105°C
  • high efficiency up to 85%
  • UL 62368, EN 62368, IEC 62368 Approval PART NUMBER KEY PEP1 - S5 - XXX - M Input Voltage Output S = single D = dual Packaging Style SMT Output VoltageBase Number MODEL input voltage output voltage output current output power output capacitance ripple and noise1 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) max (µF) max (mVp-p) typ (%) PEP1-S5-D3-M 5 4.5~5.5 ±3.3 ±15 ±151 1 1200 75 74 PEP1-S5-D5-M 5 4.5~5.5 ±5 ±10 ±100 1 1200 75 82 PEP1-S5-D9-M 5 4.5~5.5 ±9 ±6 ±56 1 470 75 83 PEP1-S5-D12-M 5 4.5~5.5 ±12 ±5 ±42 1 220 75 83 PEP1-S5-D15-M 5 4.5~5.5 ±15 ±4 ±34 1 220 75 83 PEP1-S5-D24-M 5 4.5~5.5 ±24 ±2 ±21 1 100 100 85 PEP1-S5-S3-M 5 4.5~5.5 3.3 30 303 1 2400 75 74 PEP1-S5-S5-M 5 4.5~5.5 5 20 200 1 2400 75 82 PEP1-S5-S9-M 5 4.5~5.5 9 12 111 1 1000 75 83 PEP1-S5-S12-M 5 4.5~5.5 12 9 84 1 560 75 83 PEP1-S5-S15-M 5 4.5~5.5 15 7 67 1 560 75 83 PEP1-S5-S24-M 5 4.5~5.5 24 4 42 1 220 100 85 Notes: 1. Ripple & noise testing condition at nominal input voltage and 10%~100% load, 20 MHz bandwidth Additional Resources: Product Page | 3D Model | PCB Footprint

cui.com CUI Inc │ SERIES: PEP1-M │ DESCRIPTION: DC-DC CONVERTER date 07/06/2021 │ page 2 of 6 INPUT parameter conditions/description min typ max units input voltage 4.5 5 5.5 Vdc surge voltage 5 Vdc input, for maximum of 1 second -0.7 9 Vdc filter capacitance filter current full load/no load 3.3/5 Vdc output 9/12 Vdc output 15/24 Vdc output mA mA mA OUTPUT parameter conditions/description min typ max units line regulation Vin change ±1%

3.3 Vdc output

1.5 1.2 %/% %/% load regulation 10% ~ 100% load

5 Vdc output

9 Vdc output

12 Vdc output

15 Vdc output

24 Vdc output

set-point accuracy see regulation curve switching frequency full load, nominal input 270 kHz temperature coefficient full load ±0.02 %/°C PROTECTIONS parameter conditions/description min typ max units short circuit protection Continuous, self-recovery Additional Resources: Product Page | 3D Model | PCB Footprint

cui.com CUI Inc │ SERIES: PEP1-M │ DESCRIPTION: DC-DC CONVERTER date 07/06/2021 │ page 3 of 6 ENVIRONMENTAL parameter conditions/description min typ max units operating temperature -40 105 °C storage temperature -55 125 °C humidity non-condensing 5 95 % SOLDERABILITY parameter conditions/description min typ max units reflow soldering 60 s max over 217°C 245 °C SAFETY AND COMPLIANCE parameter conditions/description min typ max units isolation voltage input-output electric strength test for 1 minute 3000 Vdc isolation resistance input-output insulation at 500 Vdc 1000 MΩ isolation capacitance input-output capacitance at 100 KHz / 0.1 V 20 pF safety approvals UL62368/EN62368/IEC62368 EMC CISPR32/EN55032 Class B (see recommended circuit) ESD IEC/EN61000-4-2, Air ±8kV, Contact ±4kV, perf. Criteria B RoHS yes MTBF MIL-HDBK-217F @ 25°C 3500 kHours DERATING CURVE Additional Resources: Product Page | 3D Model | PCB Footprint

cui.com CUI Inc │ SERIES: PEP1-M │ DESCRIPTION: DC-DC CONVERTER date 07/06/2021 │ page 4 of 6 MECHANICAL parameter conditions/description min typ max units dimensions 15.24 x 11.40 x 7.25 mm case material Black plastic; flame-retardant and heat-resistant (UL94-V0) weight 1.3 g MECHANICAL DRAWING PIN CONNECTIONS PIN Single Dual

1 GND GND

2 Vin Vin

6 NC -Vo

units: mm [inches] tolerance: ± 0.25 [±0.010] Note: NC pin to be isolated from other circuitry Additional Resources: Product Page | 3D Model | PCB Footprint

cui.com CUI Inc │ SERIES: PEP1-M │ DESCRIPTION: DC-DC CONVERTER date 07/06/2021 │ page 5 of 6 RECOMMENDED CIRCUITS EMC COMPLIANCE CIRCUITS Parameter Description Vin (Vdc) Cin (µF) Vo (Vdc) Cout (µF) 5 4.7 3.3/5 10 9 4.7 12 2.2 15 1 24 0.47 Note: For EMC tests we use Part ① in Fig. 3 for immunity and part ➁ for emissions test. Selecting based on needs. Recommended EMC Filter Values Output Voltage (Vdc) 3.3/5/9 12/15/24 EMI C1/C2 47µF / 25V 47µF / 25V CY - - 1nF/4KVDC VISHAY HGZ102MBP TDK CD45-E2GA102M-GKA C3 refer to the Cout in table 1 LDM 6.8µH 6.8µH Additional Resources: Product Page | 3D Model | PCB Footprint

CUI Inc │ SERIES: PEP1-M │ DESCRIPTION: DC-DC CONVERTER date 07/06/2021 │ page 6 of 6 CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com rev. description date 1.0 initial release 03/28/2020 1.01 units updated in mechanical drawing section 01/20/2021 1.02 derating curves and circuit figures updated 07/06/2021 The revision history provided is for informational purposes only and is believed to be accurate.