cui.com date 05/10/2019 page 1 of 7 SERIES: PEME1-S │ DESCRIPTION: DC-DC CONVERTER

FEATURES

  • 1 W isolated output
  • unregulated output
  • compact SIP package
  • single/dual output models
  • continuous short circuit protection
  • extended temperature range (-40~105°C)
  • 3 kVdc isolation
  • no load input current as low as 5 mA
  • UL 62368 approval
  • efficiency up to 85% MODEL input voltage output voltage output current output power ripple & noise1 efficiency2 typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) max (mVp-p) typ (%) PEME1-S5-S3-S 5 4.5~5.5 3.3 30 303 1 75 74 PEME1-S5-S5-S 5 4.5~5.5 5 20 200 1 75 82 PEME1-S5-S9-S 5 4.5~5.5 9 12 111 1 75 83 PEME1-S5-S12-S 5 4.5~5.5 12 9 84 1 75 83 PEME1-S5-S15-S 5 4.5~5.5 15 7 67 1 75 83 PEME1-S5-S24-S 5 4.5~5.5 24 4 42 1 100 85 PEME1-S5-D3-S3 5 4.5~5.5 ±3.3 ±15 ±152 1 75 74 PEME1-S5-D5-S 5 4.5~5.5 ±5 ±10 ±100 1 75 82 PEME1-S5-D9-S 5 4.5~5.5 ±9 ±6 ±56 1 75 83 PEME1-S5-D12-S 5 4.5~5.5 ±12 ±5 ±42 1 75 83 PEME1-S5-D15-S 5 4.5~5.5 ±15 ±4 ±34 1 75 83 PEME1-S5-D24-S 5 4.5~5.5 ±24 ±3 ±21 1 100 85 Notes: 1. Measured at nominal input, 20 MHz bandwidth oscilloscope, with 10 µF tantalum and 1 µF ceramic capacitors on the output. 2. Measured at nominal input voltage, full load. 3. Model is not UL or CE certified. 4. All specifications are measured at Ta=25°C, humidity < 75%, nominal input voltage, and rated output load unless otherwise specified. For more information, please visit the product page.

cui.com date 05/10/2019 │ page 2 of 7CUI Inc │ SERIES: PEME1-S │ DESCRIPTION: DC-DC CONVERTER PART NUMBER KEY Base Number PEME1-S XX - X XX - S Input Voltage Output Voltage Mounting Style: SIPOutput: S = single D = dual INPUT parameter conditions/description min typ max units operating input voltage 4.5 5 5.5 Vdc surge voltage for maximum of 1 second -0.7 9 Vdc current 3.3, 5 Vdc output models 9, 12 Vdc output models all other models 286 254 254 mA mA mA filter filter capacitor OUTPUT parameter conditions/description min typ max units maximum capacitive load5 3.3, 5 Vdc output models

9 Vdc output models

12, 15 Vdc output models 24, ±12, ±15 Vdc output models ±3.3, ±5 Vdc output models ±9 Vdc output models all other models 2,400 1,000 560 220 1,200 470 100 μF μF μF μF μF μF μF voltage accuracy see tolerance envelope curves line regulation for Vin change of 1%

3.3 Vdc output models

±1.5 ±1.2 load regulation from 10% to full load

5 Vdc output models

±20 ±15 ±10 switching frequency at nominal input, full load 270 kHz temperature coefficient at full load ±0.02 %/°C Note: 5. Tested at input voltage range and full load. PROTECTIONS parameter conditions/description min typ max units short circuit protection continuous, self recovery SAFETY AND COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute at 1 mA 3,000 Vdc isolation resistance input to output at 500 Vdc 1,000 MΩ isolation capacitance input to output, 100 kHz / 0.1 V 20 pF safety approvals6 UL 62368-1, EN 62368-1 conducted emissions CISPR32/EN55032, class B (external circuit required, see Figure 3) Note: 6. Model PEME1-S5-D3-S does not have UL or CE certification. For more information, please visit the product page.

cui.com date 05/10/2019 │ page 3 of 7CUI Inc │ SERIES: PEME1-S │ DESCRIPTION: DC-DC CONVERTER Ambient Temperature (°C) Output Load (%) -40 100 04 0 105 Temperature Derating Curve (Natural Convection) 120 120 8520 60-20 Rated Output Voltage Output Current Percentage (%) (Nominal Input Voltage) Tolerance Envelope Curve (all other models) Output Voltage Accuracy (%) 10 20 40 60 80 100 Rated Output Voltage -12 Output Current Percentage (%) (Nominal Input Voltage) Tolerance Envelope Curve (3.3 Vdc output only) Output Voltage Accuracy (%) Typical Load Line -10 -15 10 20 40 60 80 100 2.5 -2.5 Typical Load Line -10 -7.5 Max Max Min Min SAFETY AND COMPLIANCE (CONTINUED) parameter conditions/description min typ max units radiated emissions CISPR32/EN55032, class B (external circuit required, see Figure 3) ESD IEC/EN61000-4-2, air ± 8 kV; contact ± 4 kV, class B MTBF as per MIL-HDBK-217F, 25°C 3,500,000 hours RoHS yes ENVIRONMENTAL parameter conditions/description min typ max units operating temperature see derating curves -40 105 °C storage temperature -55 125 °C storage humidity non-condensing 95 % case temperature rise 3.3 Vdc output model at 25°C all other models at 25°C DERATING CURVES For more information, please visit the product page.

cui.com date 05/10/2019 │ page 4 of 7CUI Inc │ SERIES: PEME1-S │ DESCRIPTION: DC-DC CONVERTER units: mm [inch] tolerance: ±0.25[±0.010] pin section tolerance: ±0.10[±0.004] MECHANICAL parameter conditions/description min typ max units case material black flame-retardant and heat-resistant plastic (UL94V-0) weight 2.1 g MECHANICAL DRAWING PIN CONNECTIONS PIN Function Single Dual

1 Vin Vin

2 GND GND

6 No Pin 0V

10 Sec. Max. Wave Soldering Time 4 Sec. Max. Peak Temp. 260°C Max. Time (sec.) Temperature (°C) 250 200 150 100 SOLDERABILITY parameter conditions/description min typ max units hand soldering 1.5 mm from case for 10 seconds 300 °C wave soldering see wave soldering profile 260 °C For more information, please visit the product page.

cui.com date 05/10/2019 │ page 6 of 7CUI Inc │ SERIES: PEME1-S │ DESCRIPTION: DC-DC CONVERTER PACKAGING units: mm Tube Size: 16.9 x 9.6 mm Inner Carton Size: 575 x 135 x 100 mm Outer Carton Size: 610 x 285 x 125 mm Outer Carton QTY: 3,200 pcs For more information, please visit the product page.

date 05/10/2019 │ page 7 of 7CUI Inc │ SERIES: PEME1-S │ DESCRIPTION: DC-DC CONVERTER CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com rev. description date 1.0 initial release 05/10/2019 The revision history provided is for informational purposes only and is believed to be accurate.

REVISION HISTORY

For more information, please visit the product page.