PE9345DEV PLETRONICS | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 8

Technical content

Product information is current as of publication date. The product conforms Copyright © 2007, 2008 Pletronics Inc. to specifications per the terms of the Pletronics standard warranty. Production processsing does not necessarily include testing of all parameters. PE93D Series 3.3 V PECL Clock Oscillators February 2008

  • Pletronics’ PE93D Series is a quartz crystal controlled precision square wave generator with a PECL output.
  • The package is designed for high density surface mount designs.
  • Low cost mass produced oscillator.
  • Tape and Reel or cut tape packaging.
  • 5 x 7 mm LCC Ceramic Package
  • Enable/Disable Function on pad 2
  • Output frequency is synthesized.
  • Low Jitter
  • RoHS 6/6 Compliant Pletronics Inc. certifies this device is in accordance with the RoHS 6/6 (2002/95/EC) and WEEE (2002/96/EC) directives. Pletronics Inc. guarantees the device does not contain the following: Cadmium, Hexavalent Chromium, Lead, Mercury, PBB’s, PBDE’s Weight of the Device: 0.16 grams Moisture Sensitivity Level: 1 As defined in J-STD-020C Second Level Interconnect code: e4 Absolute Maximum Ratings: Parameter Unit VCC Supply Voltage -0.5V to +4.6V Vi Input Voltage -0.5V to V CC + 0.5V Vo Output Voltage -0.5V to V CC + 0.5V IO Output Current -50mA Thermal Characteristics The maximum die or junction temperature is 155oC The thermal resistance junction to board is 30 to 50oC/Watt depending on the solder pads, ground plane and construction of the PCB.

PE93D Series 3.3 V PECL Clock Oscillators February 2008 www.pletronics.com 425-776-1880 2 Part Number: PE93 45 D E V -125.0M -XX Packaging code or blank T250 = 250 per Tape and Reel T500 = 500 per Tape and Reel T1K = 1000 per Tape and Reel Frequency in MHZ Supply Voltage V CC V = 3.3V +_ 10% Temperature Range blank = -10 to +70oC E = -40 to +85oC Series Model Frequency Stability 45 = +_ 50 ppm 44 = +_ 25 ppm 20 = +_ 20 ppm Series Model Part Marking: PLE PE93 Marking Legend: FF.FFF M PLE = Pletronics C YMDXX FF.FFF M = Frequency in MHz YMD = Date of Manufacture (year-month-day) All other marking is internal factory codes Codes for Date Code YMD Code 7 8 9 0 1 2 Year 2007 2008 2009 2010 2011 2012 Code A B C D E F G H J K L M Month JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC C o d e 123456789A B C Day 123456789 1 0 1 1 1 2 Code D E F G H J K L M N P R Day 13 14 15 16 17 18 19 20 21 22 23 24 Code T U V W X Y Z Day 25 26 27 28 29 30 31

PE93D Series 3.3 V PECL Clock Oscillators February 2008 www.pletronics.com 425-776-1880 3 Electrical Specification for 3.30V +_10% over the specified temperature range and the frequency range of 10.9 MHZ to 766 MHZ and 876 MHZ to 1,175MHz Item Min Max Unit Condition Frequency Accuracy “45" -50 +50 ppm For all supply voltages, load changes, aging for 1 year, shock, vibration and temperatures “44" -25 +25 “20" -20 +20 Output Waveform PECL / ECL Output High Level 2.12 2.49 volts Referenced to Ground, V CC = 3.3 V 0.82 1.19 volts Referenced to termination voltage, VCC = 3.3 V -1.18 -0.81 volts Referenced to Vcc, V CC = 3.3 V Output Low Level 1.83 1.99 volts Referenced to Ground, V CC = 3.3 V 0.53 0.69 volts Referenced to termination voltage, VCC = 3.3 V -1.47 -1.31 volts Referenced to Vcc, V CC = 3.3 V Output Peak to Peak Level 0.405 1.076 volts Output Symmetry 47 53 % at 50% point of V CC (See load circuit) Jitter - 0.6 pS RMS 12 KHz to 20 MHZ from the output frequency - 2.8 pS RMS 10 Hz to 20 MHZ from the output frequency Output TRISE and TFALL 100 300 pS Vth is 20% and 80% of waveform VCC Supply Current (ICC)- 9 0 m A Enable/Disable Internal Pull-up 50 - Kohm to V CC V disable - 0.8 volts Referenced to pad 3 V enable 2.00 - volts Referenced to pad 3 Output leakage V OUT = VCC -50 +50 uA Pad 1 low, device disabled VOUT = 0V -50 +50 uA Enable time - 10 nS Time for output to reach a logic state Disable time - 10 nS Time for output to reach a high Z state Start up time - 5 mS Time for output to reach specified frequency Operating Temperature Range -10 +70 oC Standard Temperature Range - 40 +85 oC Extended Temperature Range “E” Option Storage Temperature Range -55 +125 oC Specifications with Pad 1 E/D open circuit or connected to VCC

PE93D Series 3.3 V PECL Clock Oscillators February 2008 www.pletronics.com 425-776-1880 4 -160 -140 -120 -100 -80 -60 -40 -20 10 1,000 100,000 10,000,000 Frequency (Hz) dBc/Hz 100MHz dBc/Hz 400MHz dBc/Hz 1000MHz dBc/Hz Showing Out Measurement only Trise Symmetry 20% Vlow 50% 80% Vhigh Tfall Out* Out Typical Phase-Noise Response Load Circuit Test Waveform

PE93D Series 3.3 V PECL Clock Oscillators February 2008 www.pletronics.com 425-776-1880 5 Reliability: Environmental Compliance Parameter Condition Mechanical Shock MIL-STD-883 Method 2002, Condition B Vibration MIL-STD-883 Method 2007, Condition A Solderability MIL-STD-883 Method 2003 Thermal Shock MIL-STD-883 Method 1011, Condition A ESD Rating Model Minimum Voltage Conditions Human Body Model 2000 MIL-STD-883 Method 3115 Charged Device Model 1500 JESD 22-C101 Package Labeling Font is Courier New Font is Arial Bar code is 39-Full ASCII

PE93D Series 3.3 V PECL Clock Oscillators February 2008 www.pletronics.com 425-776-1880 6 5 6 Mechanical: Inches mm C 0.067 max 1.70 max D 1 0.038 0.96 E1 0.200 5.08 F1 0.004 0.10 G1 0.050 1.27 H1 0.055 1.40 Contacts: Gold 11.8 µinches 0.3 µm minimum over Nickel 50 to 350 µinches 1.27 to 8.89 µm

1 Typical dimensions

I1 0.024 0.60 J1 0.004r 0.10r K1 0.008r 0.20r L1 0.089 2.25 Center metalized pad on the base is not connected. M1 0.010r 0.25r Pad Function Note 1 No connect The pad can be connected to Vcc, Ground or left open. This pad is internally connected. Connect to Vcc or Ground for best thermal resistance.

2 Output

When this pad is not connected the oscillator shall operate. When this pad is <0.80 volts, the output will be inhibited (high impedance state.) Recommend connecting this pad to VCC if the oscillator is to be always on.

3 Ground (GND)

4 Output Both outputs must be terminated and biased for proper operation. The ideal termination is 50 ohms connected to 2.0V below the Supply Voltage. The outputs become a High Z when disabled and the voltage level is determined by the termination circuitry.5 Output*

6 Supply Voltage

CC) Recommend connecting appropriate power supply bypass capacitors as close as possible.

PE93D Series 3.3 V PECL Clock Oscillators February 2008 www.pletronics.com 425-776-1880 7 260°C Maximum

10 Seconds Maximum

215°C±10°C Approximately 50 Seconds Allowed rate of temperature change Maximum 4°C per second 120 to 160 Seconds 100 150 200 250Temperature (°C) 175°C±10°C Reflow Cycle (typical for lead free processing) The part may be reflowed 2 times without degradation. Tape and Reel: available for quantities of 250 to 1000 per reel, cut tape for < 250 Constant Dimensions Table 1 Tape Size D0 D1 Min E1 P0 P2 S1 Min T Max Max 8mm 1.5 +0.1 -0.0 1.0 1.75 +_0.1 4.0 +_0.1 2.0 +_0.05 0.6 0.6 0.1 12mm 1.5 16mm 1.5 2.0 +_0.1 24mm 1.5 Variable Dimensions Table 2 Tape Size Max E2 Min F P1 T2 Max W Max Ao, Bo & Ko Note 1: Embossed cavity to conform to EIA-481-B Dimensions in mm Not to scale REEL DIMENSIONS A inches 7.0 10.0 13.0 mm 177.8 254.0 330.2 B inches 2.50 4.00 3.75 mm 63.5 101.6 95.3 Tape Width D mm 16.4 +2.0 -0.0 16.4 +2.0 -0.0 16.4 +2.0 -0.0 16.0 mm --- --- 24.4 +2.0 -0.0 24.0 mm --- --- 32.4 +2.0 -0.0 32.0 Reel dimensions may vary from the above

PE93D Series 3.3 V PECL Clock Oscillators February 2008 www.pletronics.com 425-776-1880 8 IMPORTANT NOTICE Pletronics Incorporated (PLE) reserves the right to make corrections, improvements, modifications and other changes to this product at anytime. PLE reserves the right to discontinue any product or service without notice. Customers are responsible for obtaining the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to PLE’s terms and conditions of sale supplied at the time of order acknowledgment. PLE warrants performance of this product to the specifications applicable at the time of sale in accordance with PLE’s limited warranty. Testing and other quality control techniques are used to the extent PLE deems necessary to support this warranty. Except where mandated by specific contractual documents, testing of all parameters of each product is not necessarily performed. PLE assumes no liability for application assistance or customer product design. Customers are responsible for their products and applications using PLE components. To minimize the risks associated with the customer products and applications, customers should provide adequate design and operating safeguards. PLE products are not designed, intended, authorized or warranted to be suitable for use in life support applications, devices or systems or other critical applications that may involve potential risks of death, personal injury or severe property or environmental damage. Inclusion of PLE products in such applications is understood to be fully at the risk of the customer. Use of PLE products in such applications requires the written approval of an appropriate PLE officer. Questions concerning potential risk applications should be directed to PLE. PLE does not warrant or represent that any license, either express or implied, is granted under any PLE patent right, copyright, artwork or other intellectual property right relating to any combination, machine or process which PLE product or services are used. Information published by PLE regarding third-party products or services does not constitute a license from PLE to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from PLE under the patents or other intellectual property of PLE. Reproduction of information in PLE data sheets or web site is permissible only if the reproduction is without alteration and is accompanied by associated warranties, conditions, limitations and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. PLE is not responsible or liable for such altered documents. Resale of PLE products or services with statements different from or beyond the parameters stated by PLE for that product or service voids all express and implied warranties for the associated PLE product or service and is an unfair or deceptive business practice. PLE is not responsible for any such statements. Contacting Pletronics Inc. Pletronics Inc. Tel: 425-776-1880 19013 36 th Ave. West Fax: 425-776-2760 Lynnwood, WA 98036-5761 USA E-mail: ple-sales@pletronics.com URL: www.pletronics.com Copyright © 2005, 2006, 2008 Pletronics Inc.