Features
- 83% V elocity of Propagation Shielding ef fectiveness > 95 dB Maximum VSWR is < 1.35:1 to 18 GHz Minimum Bend Radius of 1 inch Operating Temperature range of -55 to +125 °C ROHS and REACH Compliant Same day shipment of custom lengths 100% Continuity , Hi-Pot, and RF tested
Description
The PE340 series high performance test cable’s 0.195 inch diameter and 83% phase velocity offer very low loss performance up to 18 GHz. The durable stainless steel connectors and FEP jacket provide a cost effective design ideal for test environ - ments where a rugged cable assembly is required. The series is offered with Type N, TNC, and SMA connectors all rated to 18 GHz. A heavy duty boot provides improved strain relief and adds to the durability of the cable assemblies. These cable assemblies are built using a double shielded flexible cable, providing excellent shielding effectiveness of greater than 95 dB. All PE340 cable assemblies are 100% Continuity, Hi-POT, and RF tested to published specifications. Custom lengths are built to order and shipped same day. Electrical Specifications Description Minimum T ypical Maximum Units Frequency Range DC 18 GHz VSWR 1.35:1 Velocity of Propagation 83 % RF Shielding 95 dB Capacitance 25 [82.02] pF/ft [pF/m] Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price, inventory and certifications: SMA Male to SMA Male Low Loss Test Cable Using PE-P142LL Coax, RoHS PE341 PE341 REV 1.3 SMA Male to SMA Male Low Loss Test Cable Using PE-P142LL Coax, RoHS RF Cable Assemblies Technical Data Sheet PE341
Specifications by Frequency Description F1 F2 F3 F4 F5 Units Frequency 1 2 5 10 18 GHz Power Handling (Max.) 700 400 300 220 160 Watts Electrical Specification Notes: Power handling values are calculated based on Cable properties. Power handling will vary based on the actual VSWR of the cable assembly. Insertion Loss does not include the loss of the connectors. Insertion Loss is estimated as .05dB x SQRT (Frequency GHz) per connector. Mechanical Specifications Cable Assembly Diameter 0.37 in [9.4 mm] Weight 0.12 lbs [54.43 g] Cable Cable Type PE-P142LL Impedance 50 Ohms Inner Conductor Type Solid Inner Conductor Material and Plating Copper , Silver Dielectric Type PTFE Number of Shields 3 Shield Layer 1 Silver Plated Copper Tape Shield Layer 2 Aluminum Polyester Shield Layer 3 Silver Plated Copper Wire Jacket Material FEP , Green Jacket Diameter 0.195 in [4.95 mm] Repeated Minimum Bend Radius 1 in [25.4 mm] PE341 REV 1.3 Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price, inventory and certifications: SMA Male to SMA Male Low Loss Test Cable Using PE-P142LL Coax, RoHS PE341 RF Cable Assemblies Technical Data Sheet PE341 SMA Male to SMA Male Low Loss Test Cable Using PE-P142LL Coax, RoHS
Description Connector 1 Connector 2 Type SMA Male SMA Male Specification MIL-STD-348, Fig 310-1 MIL-STD-348, Fig 310-1 Impedance 50 Ohms 50 Ohms Contact Material and Plating Beryllium Copper , Gold Beryllium Copper , Gold Contact Plating Specification ASTM-B488 50µ In. Minimum ASTM-B488 50µ In. Minimum Dielectric Type PTFE PTFE Coupling Nut Material and Plating Passivated Stainless Steel Passivated Stainless Steel Coupling Nut Plating Specification SAE-AMS-2700 SAE-AMS-2700 Hex Size 5/16 Inch 5/16 Inch Torque 8 in-lbs [0.9 Nm] 8 in-lbs [0.9 Nm] Body Material and Plating Passivated Stainless Steel Passivated Stainless Steel Body Plating Specification SAE-AMS-2700 SAE-AMS-2700 Environmental Specifications Temperature Operating Range -55 to +125 deg C Compliance Certifications (visit www.Pasternack.com for current document) RoHS Compliant Y es REACH Compliant 12/17/2015 Plotted and Other Data Notes:
- Values at 25°C, sea level. PE341 REV 1.3 Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price, inventory and certifications: SMA Male to SMA Male Low Loss Test Cable Using PE-P142LL Coax, RoHS PE341 RF Cable Assemblies Technical Data Sheet SMA Male to SMA Male Low Loss Test Cable Using PE-P142LL Coax, RoHS PE341
Part Number Configuration: PE341 - xx uu | | | Unit of Measure: | | cm = Centimeters | | <blank> = Inches | Length | Base Number Example: PE341-12 = 12 inches long cable PE341-100cm = 100 cm long cable SMA Male to SMA Male Low Loss Test Cable Using PE-P142LL Coax, RoHS from Pasternack Enterprises has same day shipment for domestic and International orders. Our RF, microwave and millimeter wave products maintain a 99% availability and are part of the broadest selection in the industry. Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price, inventory and certifications: SMA Male to SMA Male Low Loss Test Cable Using PE-P142LL Coax, RoHS PE341 URL: http://www.pasternack.com/sma-male-sma-male-pe-p142ll-cable-assembly-pe341-p.aspx PE341 REV 1.3 RF Cable Assemblies Technical Data Sheet SMA Male to SMA Male Low Loss Test Cable Using PE-P142LL Coax, RoHS PE341
5PE341 REV 1.3 SMA Male to SMA Male Low Loss Test Cable Using PE-P142LL Coax, RoHS PE341 CAD Drawing