Features

Single-Phase 32A 200-240V ATS PDU Distributes and Monitors Network-Grade Power in Real Time This monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via its built-in network interface. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMNH32HVAT2 features 16 C13 and 2 C19 outlets in two load banks, each bank protected by a 20A circuit breaker. Dual three-meter power cords with IEC 309 32A Blue inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources. Switches from Primary to Secondary Power Source in Milliseconds Dynamic solid-state automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 1-5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source. Built-In LX Platform Network Management Card Allows Remote Access 24/7 The Java-free HTML5-based WEBCARDLX network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. The latest version of PowerAlert Device Manager (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. Digital Load Meter Helps Prevent Potentially Expensive Overloads A digital ammeter reports the total load for all connected equipment in amps and kilowatts. Monitoring capacity helps ensure load levels remain well below maximum capacity levels with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low. Current monitoring provides 1% billing grade accuracy. Mounts into 2U of Rack Space or on a Wall Highlights Built-in HTML5-based LX Platform interface allows you 24/7 remote access Enables redundant A/B power option for single-corded network devices Digital meter for real-time voltage, amp and load monitoring helps prevent overloads 3 m cords with IEC 309 32A Blue inputs connect to separate power sources Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases Package Includes PDUMNH32HVAT2 7.4kW Single-Phase ATS/Monitored PDU Configuration cable, USB-A to USB Micro-B Rack-mounting hardware● Installable plug-retention sleeves Cable ties● Owner's manuals●

Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter. TAA-Compliant for GSA Schedule Purchases The PDUMNH32HVAT2 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts. OVERVIEW UPC Code 037332261441 PDU Type Auto-Transfer Switch; Local Metered; Monitored INPUT PDU Input Voltage 200-240V Recommended Electrical Service 32A 230V Maximum Input Amps 32 PDU Plug Type (2) IEC-309 32A BLUE (2P+E) Input Phase Single-Phase Input Cord Details Set of two inputs connect to separate PRIMARY and SECONDARY power sources Input Cord Length (ft.) 10 Input Cord Length (m) 3.05 OUTPUT Output kW Capacity (kW) 7.4 Output Capacity Details 7.4kW (230V), 7.0kW (220V), 6.4kW (200V); 32A maximum; 16A max per breakered outlet bank; 16A max per C19 outlet; 10A max per C13 outlet Frequency Compatibility 50 / 60 Hz Output Receptacles (16) C13; (2) C19 Output Nominal Voltage 200; 220; 230 Overload Protection Includes two 20A output circuit breakers; Breaker 1 controls the upper row of 9 outlets (8 C13, 1 C19); Breaker 2 controls the lower row of outlets (8 C13, 1 C19) USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display Digital display reports output amps and kilowatts in 4 separately metered loading segments (BANK 1: Outlets #1-9; BANK 2: Outlets #10-18), whole-PDU output kW load level and input voltage on primary and secondary input lines, IP address. Temperature and Humidity will report through display when an optional Envirosense2 module is attached. Front Panel LEDs Front panel LEDs confirm amp / kilowatt / voltage reporting information. Two AC active source LEDs for primary and secondary input availability. Switches ENTER and MODE switches toggle the digital display to show output amps (Banks 1-4), total kW output and input voltage (primary, secondary), and IP address..

Material of Construction Metal Form Factors Supported 2U rackmount Minimum Required Rack Depth (cm)40.64 Minimum Required Rack Depth (inches) 16 PDU Form Factor Horizontal (2U) Shipping Dimensions (hwd / in.) 7.70 x 16.70 x 19.30 Shipping Weight (kg) 9.21 Unit Dimensions (hwd / in.) 3.5 x 17.5 x 12.5 Unit Dimensions (hwd / cm) 8.8 x 44.4 x 31.7 Unit Weight (lbs.) 13.7 Unit Weight (kg) 6.21 ENVIRONMENTAL Operating Temperature Range 0C ~ 40C (32F ~ 104F) Storage Temperature Range -30°C to +50°C (-22°F to +122°F) Relative Humidity 5-95% non condensing Operating Elevation (ft.) 0-10,000 Operating Elevation (m) 0-3000 COMMUNICATIONS PowerAlert Software LX Platform Interface: PowerAlert Device Manager Communications Cable Micro-USB- to-USB A configuration/console Access cable Network Monitoring Port RJ45 Network port, Micro-USB Configuration port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. SNMP Compatibility Yes Network Compatibility 10 Mbps; 100 Mbps (Fast Ethernet) Network Speed Details 10 / 100 Network Management Card Description PowerAlert Device Manager 20 (PADM20) supports SNMP / HTTP / HTTPS / TELNET / SSH / CLI user interfaces Communications Interface (1) DB9 Serial; (1) Micro-USB; (1) Pre-installed network card; (1) RJ45 Network; (1) USB-A FEATURES & SPECIFICATIONS High Availability PDU Features Auto-Transfer Switching

© 2022 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies: https://www.tripplite.com/products/product-certification-agencies STANDARDS & COMPLIANCE Product Certifications IEC 62368-1; RETIE (Colombia) Product Compliance RoHS; CE (Europe); FCC Part 15 Class A (USA) WARRANTY Product Warranty Period (Worldwide) 2-year limited warranty