3-BIT, ECL-INTERFACED PROGRAMMABLE DELAY LINE (SERIES PDU53) data delay devices, inc.

FEATURES

Digitally programmable in 8 delay steps Monotonic delay-versus-address variation Precise and stable delays Input & outputs fully 100K-ECL interfaced & buffered Available in 16-pin DIP (600 mil) socket or SMD PDU53-xx DIP PDU53-xxM Military DIP PDU53-xxC3 SMD PDU53-xxMC3 Mil SMD FUNCTIONAL DESCRIPTION The PDU53-series device is a 3-bit digitally programmable delay line. The delay, TDA, from the input pin (IN) to the output pin (OUT) depends on the address code (A2-A0) according to the following formula: TDA = TD0 + TINC * A where A is the address code, TINC is the incremental delay of the device, and TD0 is the inherent delay of the device. The incremental delay is specified by the dash number of the device and can range from 100ps through 3000ps, inclusively. The address is not latched and must remain asserted during normal operation. PIN DESCRIPTIONS IN Signal Input OUT Signal Output Address Bit 2 Address Bit 1 Address Bit 0 VEE -5 Volts GND Ground SERIES SPECIFICATIONS Total programmed delay tolerance: 5% or 40ps, whichever is greater Inherent delay (TD0): 2.2ns typical Address to input setup (TAIS): 2.9ns Operating temperature: 0° to 85° C Temperature coefficient: 100PPM/°C (excludes TD0) Supply voltage VEE: -5VDC ± 0.7V Power Supply Current: -150ma typical (50Ω to -2V) Minimum pulse width: 3ns or 15% of total delay, whichever is greater Minimum period: 8ns or 2 x pulse width, whichever is greater DASH NUMBER SPECIFICATIONS Part Number Incremental Delay Per Step (ps) Total Delay Change (ns) PDU53-100 100 ± 50 0.70 PDU53-200 200 ± 60 1.40 PDU53-250 250 ± 60 1.75 PDU53-400 400 ± 80 2.80 PDU53-500 500 ± 100 3.50 PDU53-750 750 ± 100 5.25 PDU53-1000 1000 ± 200 7.00 PDU53-1200 1200 ± 200 8.40 PDU53-1500 1500 ± 200 10.50 PDU53-2000 2000 ± 400 14.00 PDU53-2500 2500 ± 400 17.50 PDU53-3000 3000 ± 500 21.00 NOTE: Any dash number between 100 and 3000 not shown is also available. TOAX PWIN TDA PWOUT A2-A0 IN OUT Figure 1: Timing Diagram A i-1 Ai TAIS 1997 Data Delay Devices Doc #98003 DATA DELAY DEVICES, INC. 3/18/98 3 Mt. Prospect Ave. Clifton, NJ 07013

The PDU53 is a memory device. As such, special precautions must be taken when changing the delay address in order to prevent spurious output signals. The timing restrictions are shown in Figure 1. After the last signal edge to be delayed has appeared on the OUT pin, a minimum time, TOAX, is required before the address lines can change. This time is given by the following relation: TOAX = max { (Ai - A i-1) * TINC , 0 } where A i-1 and Ai are the old and new address codes, respectively. Violation of this constraint may, depending on the history of the input signal, cause spurious signals to appear on the OUT pin. The possibility of spurious signals persists until the required TOAX has elapsed. INPUT RESTRICTIONS There are three types of restrictions on input pulse width and period listed in the AC Characteristics table. The recommended conditions are those for which the delay tolerance specifications and monotonicity are guaranteed. The suggested conditions are those for which signals will propagate through the unit without significant distortion. The absolute conditions are those for which the unit will produce some type of output for a given input. When operating the unit between the recommended and absolute conditions, the delays may deviate from their values at low frequency. However, these deviations will remain constant from pulse to pulse if the input pulse width and period remain fixed. In other words, the delay of the unit exhibits frequency and pulse width dependence when operated beyond the recommended conditions. Please consult the technical staff at Data Delay Devices if your application has specific high-frequency requirements. Please note that the increment tolerances listed represent a design goal. Although most delay increments will fall within tolerance, they are not guaranteed throughout the address range of the unit. Monotonicity is, however, guaranteed over all addresses. PACKAGE DIMENSIONS .870±.010 16 15 14 13 12 11 10 .380 MAX. .015 TYP. .070 MAX. .018 TYP. .700±.010

7 Equal spaces

each .100±.010 Non-Accumulative .580 MAX. .600 ±.00 .010 ±.002 Lead Material: Nickel-Iron alloy 42 TIN PLATE PDU53-xx (Commercial DIP) PDU53-xxM (Military DIP) Doc #98003 DATA DELAY DEVICES, INC. 3/18/98 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com

Doc #98003 DATA DELAY DEVICES, INC. 3/18/98 3 Mt. Prospect Ave. Clifton, NJ 07013 PACKAGE DIMENSIONS (cont’d) PDU53-xxC3 (Commercial SMD) PDU53-xxMC3 (Military SMD) .880±.020 .882 ±.00 .020 TYP. .040 TYP. .100 .090 .700 .380 MAX. .590 MAX. .010±.002 .050 ±.01 .710 ±.00 .007 ±.00 DEVICE SPECIFICATIONS TABLE 1: AC CHARACTERISTICS PARAMETER SYMBOL MIN TYP UNITS Total Programmable Delay TDT TINC Inherent Delay TD0 2.2 ns Address to Input Setup Time TAIS 2.9 ns Output to Address Change TOAX See Text Absolute PERIN % of TDT Input Period Suggested PERIN % of TDT Recommended PERIN 200 % of TDT Absolute PWIN % of TDT Input Pulse Width Suggested PWIN % of TDT Recommended PWIN 100 % of TDT TABLE 2: ABSOLUTE MAXIMUM RATINGS PARAMETER SYMBOL MIN MAX UNITS NOTES DC Supply Voltage VEE -7.0 0.3 V Input Pin Voltage VIN VEE - 0.3 0.3 V Storage Temperature TSTRG -65 150 C Lead Temperature TLEAD 300 C 10 sec TABLE 3: DC ELECTRICAL CHARACTERISTICS (0C to 85C) PARAMETER SYMBOL MIN MAX UNITS NOTES High Level Output Voltage VOH -1.025 -0.880 V VIH = MAX,50Ω to -2V Low Level Output Voltage VOL -1.810 -1.620 V VIL = MIN, 50Ω to -2V High Level Input Voltage VIH -1.165 -0.880 V Low Level Input Voltage VIL -1.810 -1.475 V High Level Input Current IIH 340 µA VIH = MAX Low Level Input Current IIL 0.5 µA VIL = MIN

DELAY LINE AUTOMATED TESTING TEST CONDITIONS INPUT: OUTPUT: Ambient Temperature: 25oC ± 3oC Load: 50Ω to -2V Supply Voltage (Vcc): -4.5V ± 0.1V Cload: 5pf ± 10% Input Pulse: Standard 100K ECL Threshold: (VOH + VOL) / 2 levels (Rising & Falling) Source Impedance: 50Ω Max. Rise/Fall Time: 1.0 ns Max. (measured between 20% and 80%) Pulse Width: PWIN = 10ns Period: PERIN = 100ns NOTE: The above conditions are for test only and do not in any way restrict the operation of the device. OUT OUT TRIG IN REF TRIG Test Setup DEVICE UNDER TEST (DUT) OSCILLOSCOPE PULSE GENERATOR IN ADDRESS SELECT Timing Diagram For Testing TRISE TFALL PERIN PWIN TRISE TFALL 20% 20% 50% 50% 80% 80% 50% 50% VIH VIL VOH VOL INPUT SIGNAL OUTPUT SIGNAL Doc #98003 DATA DELAY DEVICES, INC. 3/18/98 Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com