DRV8452 Stepper Motor Driver with Auto-torque, Silent Step Decay Mode and Automatic Microstepping

1 Features

  • Stepper motor driver – SPI or H/W interface with STEP/DIR pins – Up to 1/256 microstepping indexer
  • 4.5 V to 48 V operating supply voltage range
  • Low RDS(ON): 100 mΩ HS + LS at 24 V, 25°C
  • High current capacity per bridge: – DDW Package: 5A full-scale, 3.5A RMS – PWP Package: 4A full-scale, 2.8A RMS
  • DDW package pin-to-pin compatible with - – DRV8462DDWR
  • PWP package pin-to-pin compatible with - – SPI Interface: DRV8434S – H/W Interface: DRV8424, DRV8426, DRV8434
  • Integrated current sensing and regulation – 5% full-scale current accuracy
  • Smart tune and mixed decay regulation options
  • Silent step decay mode for silent operation at standstill and low speed
  • Automatic Microstepping mode for step frequency interpolation
  • Customizable microstepping indexer table
  • Auto-torque for load dependent current control
  • Standstill Power Saving mode
  • Supports 1.8-V, 3.3-V, 5.0-V logic inputs
  • Low-current sleep mode (3 µA)
  • Separate logic supply voltage (VCC)
  • Protection and diagnostic features – Sensorless Stall Detection – VM undervoltage lockout (UVLO) – Open-load detection (OL) – Overcurrent protection (OCP) – Thermal shutdown (OTSD) – Fault condition output (nFAULT) – Indexer zero position output (nHOME)

2 Applications

  • Textile Machines
  • Factory Automation, Stepper Drives and Robotics
  • Medical Imaging, Diagnostics and Equipment
  • Stage Lighting
  • ATMs and Currency Counters
  • PLC
  • Printers
  • 3D Printer
  • Outdoor IP Camera

3 Description

The DRV8452 is a wide-voltage, high-power, high- performance stepper motor driver. The device supports up to 48-V supply voltage, and integrated MOSFETs with 100 m Ω HS + LS on-resistance allow up to 5-A current with the DDW package; and up to 4-A current with the PWP package. The auto-torque feature boosts system efficiency by adjusting the coil current according to load torque. The standstill power saving mode reduces power loss during motor holding condition. The silent step decay guarantees noiseless operation. The internal current sense architecture eliminates the need for external sense resistors, therefore saving PCB area and system cost. The built-in indexer supports up to 1/256 microstepping, and the automatic microstepping mode interpolates the input STEP signal to reduce overhead on the controller. Stall detection eliminates end stops from the system. The device supports other protection and diagnostic features for robust and reliable operation. The DRV8452 requires only minimal tuning to configure the advanced features. High energy efficiency coupled with precise, noiseless operation makes the DRV8452 an ideal choice for high- performance stepper motor systems. Device Information Part Number Interface Package Body Size DRV8452DDWR SPI or H/W HTSSOP (44) 14 x 6.1 mm DRV8452SPWPR SPI HTSSOP (28) 9.7 x 4.4 mm DRV8452PWPR H/W HTSSOP (28) 9.7 x 4.4 mm STEP nSLEEP ENABLE 4.5 to 48 V Controller M + – DRV8452 Protection 5 A 1/256 µ-step DIR nFAULT Smart tune + – SPI or H/W nHOME Auto Microstep Auto-torque Silent step Decay Stall Detection 5 A Custom Microstep Figure 3-1. Simplified Schematic ADVANCE INFORMATION DRV8452 SLOSE84 – AUGUST 2022 An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. ADVANCE INFORMATION for preproduction products; subject to change without notice.

12.2 Receiving Notification of Documentation Updates105

13 Mechanical, Packaging, and Orderable

4 Revision History

NOTE: Page numbers for previous revisions may differ from page numbers in the current version. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

2 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

5 Pin Configuration and Functions

Figure 5-1. DDW Package (44-Pin HTSSOP), Top View www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 3 Product Folder Links: DRV8452

Figure 5-2. PWP Package (28-Pin HTSSOP) with SPI Interface, Top View 23AOUT2 BOUT2 BOUT1 PGNDB VM nSLEEP ENABLE DIR STEP DECAY0 Thermal PAD CPL CPHVCP VM PGNDA AOUT1 DECAY1 VREF nFAULT DVDD AOUT1 AOUT2 BOUT2 15GND BOUT1 TOFF Figure 5-3. PWP Package (28-Pin HTSSOP) with H/W Interface, Top View PIN TYPE DESCRIPTION NAME DDW PWP SPI Interface H/W Interface VCC 25 19 - Power Supply voltage for internal logic blocks. When separate logic supply voltage is not available, tie the VCC pin to the DVDD pin. When configured with SPI interface, the VCC pin also acts as the supply pin for SDO output. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

4 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

This pin is not used with SPI interface. With H/W interface, this pin programs the OFF time for PWM current regulation. VCP 1 1 Power Charge pump output. Connect a X7R, 1-μF, 16-V ceramic capacitor from VCP to VM. VM 2, 11, 12, 21 2, 13 Power Power supply. Connect to motor supply voltage and bypass to PGNDA and PGNDB with two 0.01-μF ceramic capacitors plus a bulk capacitor rated for VM. PGNDA 3, 10 3 Power Power ground. Connect to system ground. PGNDB 13, 20 12 Power Power ground. Connect to system ground. AOUT1 4, 5, 6 4, 5 Output Winding A output. Connect to motor winding. AOUT2 7, 8, 9 6, 7 Output Winding A output. Connect to motor winding. BOUT2 14, 15, 16 8, 9 Output Winding B output. Connect to motor winding. BOUT1 17, 18, 19 10, 11 Output Winding B output. Connect to motor winding. GND 22, 23 14 Power Device ground. Connect to system ground. DVDD 24 15 Power Internal LDO output. Connect a X7R, 1-μF, 6.3-V or 10-V rated ceramic capacitor to GND. nFAULT 26 16 Open Drain Fault indication output. Pulled logic low with fault condition. Open-drain nFAULT requires an external pullup resistor. nHOME 27 - Open Drain Pulled logic low when the internal indexer is at home position (45°) of step table. The nHOME pin outputs one low pulse per 360º electrical rotation (four fullsteps). Only available with DDW package. MODE 28 - Input For the DDW package, MODE pin programs the device with either SPI or hardware (H/W) pin interface. RSVD 29 - - Reserved. Leave unconnected. RSVD 30 - - Reserved. Leave unconnected. RSVD 31 - - Reserved. Leave unconnected. RSVD 32 - - Reserved. Leave unconnected. VREF 33 17 Input Voltage reference input for setting full-scale current. DVDD can be used to generate VREF through a resistor divider. When configured with SPI interface, the VREF pin can be left unconnected if VREF_INT_EN = 1b. nSCS/M0 34 18 Input With SPI interface, this pin acts as serial chip select. An active low on this pin enables the serial interface communications. With H/W interface, this pin programs the microstepping mode. SDO/ DECAY1 36 20 Push-Pull/Input With SPI interface, this pin acts as serial data output. Data is shifted out on the rising edge of the SCLK pin. With H/W interface, this pin programs the decay-mode. SDI/DECAY0 37 21 Input With SPI interface, this pin acts as serial data input. Data is captured on the falling edge of the SCLK pin. With H/W interface, this pin programs the decay-mode. SCLK/M1 38 22 Input With SPI interface, this pin acts as serial clock input. Serial data is shifted out and captured on the corresponding rising and falling edge on this pin. With H/W interface, this pin programs the microstepping mode. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 5 Product Folder Links: DRV8452

Step input. An active edge causes the indexer to advance one step. With SPI interface, STEP active edge can be either rising edge or both rising and falling edge. With H/W interface, STEP active edge is always the rising edge. DIR 40 24 Input Direction input. Logic level sets the direction of stepping. ENABLE 41 25 Input Logic low to disable device outputs; logic high to enable. When the device operates with H/W interface, the ENABLE pin also determines the OCP, OL and OTSD fault recovery methods. nSLEEP 42 26 Input Sleep mode input. Logic high to enable device; logic low to enter low-power sleep mode. A narrow nSLEEP reset pulse clears latched faults. CPL 43 27 Power Charge pump switching node. Connect a X7R, 0.1-μF, VM- rated ceramic capacitor from CPH to CPL.CPH 44 28 Power PAD - - - Thermal pad. Connect to system ground. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

6 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

6 Specifications

6.1 Absolute Maximum Ratings

Power supply voltage (VM) –0.3 50 V Charge pump voltage (VCP, CPH) -0.3 VVM + 5.75 V Charge pump negative switching pin (CPL) -0.3 VVM V nSLEEP pin voltage (nSLEEP) –0.3 VVM V Internal regulator voltage (DVDD) –0.3 5.75 V External logic supply (VCC) -0.3 5.75 V Control pin voltage –0.3 5.75 V Reference input pin voltage (VREF) –0.3 5.75 V PGNDx to GND voltage -0.5 0.5 V PGNDx to GND voltage, < 1 μs -2.5 2.5 V Open drain output current (nFAULT, nHOME) 0 10 mA Continuous Output pin voltage (AOUT1, AOUT2, BOUT1, BOUT2) –1 VVM + 1 V Transient 100 ns Output pin voltage (AOUT1, AOUT2, BOUT1, BOUT2) –3 VVM + 3 V Peak drive current (AOUT1, AOUT2, BOUT1, BOUT2) Internally Limited A Operating ambient temperature, TA –40 125 °C Operating junction temperature, TJ –40 150 °C Storage temperature, Tstg –65 150 °C over operating free-air temperature range (unless otherwise noted)12 1. Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating conditions is not implied. Exposure to absolute-maximum- rated conditions for extended periods may affect device reliability. 2. All voltage values are with respect to network ground terminal GND.

6.2 ESD Ratings

V(ESD) Electrostatic discharge Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001 ±2000 V Charged-device model (CDM), per ANSI/ESDA/JEDEC JS-002 Corner pins ±750 Other pins ±500

  • JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
  • JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process. Over operating free-air temperature range (unless otherwise noted).

6.3 Recommended Operating Conditions

VVM Supply voltage range for normal (DC) operation 4.5 48 V VI Logic level input voltage 0 5.5 V www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 7 Product Folder Links: DRV8452

6.3 Recommended Operating Conditions (continued)

VVCC VCC pin voltage 3.05 5.5 V VREF Reference voltage (VREF) 0.05 3.3 V ƒSTEP Applied STEP signal (STEP) 0 100 (1) kHz IFS Motor full-scale current with DDW package (xOUTx) 0 5 (2) A IFS Motor full-scale current with PWP package (xOUTx) 0 4 (2) A IRMS Motor RMS current with DDW package (xOUTx) 0 3.5 (2) A IRMS Motor RMS current with PWP package (xOUTx) 0 2.8 (2) A TA Operating ambient temperature –40 125 °C TJ Operating junction temperature –40 150 °C 1. STEP input can operate up to 500 kHz, but system bandwidth is limited by the motor load. 2. Power dissipation and thermal limits must be observed.

6.4 Thermal Information

THERMAL METRIC DDW PWP UNIT RθJA Junction-to-ambient thermal resistance 22.5 24.5 °C/W RθJC(top) Junction-to-case (top) thermal resistance 9.8 13.5 °C/W RθJB Junction-to-board thermal resistance 5.9 5.2 °C/W ψJT Junction-to-top characterization parameter 0.2 0.2 °C/W ψJB Junction-to-board characterization parameter 5.8 5.1 °C/W RθJC(bot) Junction-to-case (bottom) thermal resistance 0.9 0.9 °C/W

6.5 Electrical Characteristics

Typical values are at TA = 25°C and VVM = 24 V. All limits are over recommended operating conditions, unless otherwise noted. PARAMETER TEST CONDITIONS MIN TYP MAX UNIT POWER SUPPLIES (VM, DVDD) IVM VM operating supply current ENABLE = 1, nSLEEP = 1, No motor load, VCC = External 5V 5 9 mA ENABLE = 1, nSLEEP = 1, No motor load, VCC = DVDD 7 12 IVMQ VM sleep mode supply current nSLEEP = 0 3 8 μA tSLEEP Sleep time nSLEEP = 0 to sleep-mode 120 μs tRESET nSLEEP reset pulse nSLEEP low to clear fault 20 40 μs tWAKE Wake-up time H/W interface, nSLEEP = 1 to output transition 0.8 1.2 ms SPI interface, nSLEEP = 1 to SPI ready 0.15 0.25 ms tON Turn-on time VM > UVLO to output transition 0.8 1.3 ms VDVDD Internal regulator voltage No external load, 6 V < VVM < 48 V 4.75 5 5.25 V No external load, VVM = 4.5 V 4.2 4.35 V CHARGE PUMP (VCP, CPH, CPL) VVCP VCP operating voltage 6 V < VVM < 48 V VVM + 5 V DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

8 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Typical values are at TA = 25°C and VVM = 24 V. All limits are over recommended operating conditions, unless otherwise noted. PARAMETER TEST CONDITIONS MIN TYP MAX UNIT f VCP Charge pump switching frequency VVM > UVLO; nSLEEP = 1 357 kHz fCLK Internal digital clock frequency VVM > UVLO; nSLEEP = 1 10 MHz LOGIC-LEVEL INPUTS (STEP, DIR, MODE, nSCS, SCLK, SDI, nSLEEP) VIL Input logic-low voltage 0 0.6 V VIH Input logic-high voltage 1.5 5.5 V VHYS Input logic hysteresis (all pins except nSLEEP) 150 mV VHYS_SLEEP nSLEEP logic hysteresis 250 mV IIL Input logic-low current VIN = 0 V –1 1 μA IIL(nSCS) nSCS logic-low current nSCS = 0V 8 12 μA IIH Input logic-high current VIN = DVDD 50 μA IIH(nSCS) nSCS logic-high current nSCS = DVDD 0.1 μA TRI-LEVEL INPUTS (M0, DECAY0, DECAY1, ENABLE) VI1 Input logic-low voltage Tied to GND 0 0.6 V VI2 Input Hi-Z voltage Hi-Z 1.8 2 2.2 V VI3 Input logic-high voltage Tied to DVDD 2.7 5.5 V IO Output pull-up current 10 μA QUAD-LEVEL INPUTS (M1, TOFF) VI1 Input logic-low voltage Tied to GND 0 0.6 V VI2 330kΩ ± 5% to GND 1 1.25 1.4 V VI3 Input Hi-Z voltage Hi-Z 1.8 2 2.2 V VI4 Input logic-high voltage Tied to DVDD 2.7 5.5 V IO Output pull-up current 10 μA PUSH-PULL OUTPUT (SDO) RPD,SDO Internal pull-down resistance 5mA load, with respect to GND 30 70 Ω RPU,SDO Internal pull-up resistance 5mA load, with respect to VCC 60 110 Ω ISDO SDO Leakage Current VVM > 6 V, SDO = VCC and 0V -1 1 μA CONTROL OUTPUTS (nFAULT, nHOME) VOL Output logic-low voltage IO = 5 mA 0.5 V IOH Output logic-high leakage -1 1 μA MOTOR DRIVER OUTPUTS (AOUT1, AOUT2, BOUT1, BOUT2) RDS(ONH,DD High-side FET on resistance, TJ = 25 °C, IO = -5 A 50 64 mΩ TJ = 125 °C, IO = -5 A 80 96 mΩ TJ = 150 °C, IO = -5 A 90 108 mΩ RDS(ONL,DD Low-side FET on resistancec, TJ = 25 °C, IO = 5 A 50 62 mΩ TJ = 125 °C, IO = 5 A 80 94 mΩ TJ = 150 °C, IO = 5 A 90 106 mΩ RDS(ONH,PW High-side FET on resistance, TJ = 25 °C, IO = -4 A 55 66 mΩ TJ = 125 °C, IO = -4 A 83 100 mΩ TJ = 150 °C, IO = -4 A 94 116 mΩ www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 9 Product Folder Links: DRV8452

Typical values are at TA = 25°C and VVM = 24 V. All limits are over recommended operating conditions, unless otherwise noted. PARAMETER TEST CONDITIONS MIN TYP MAX UNIT RDS(ONL,PW Low-side FET on resistance, TJ = 25 °C, IO = 4 A 55 66 mΩ TJ = 125 °C, IO = 4 A 83 100 mΩ TJ = 150 °C, IO = 4 A 94 116 mΩ tRF Output rise/fall time H/W Interface, IO = 5 A, between 10% and 90% 140 nsSPI Interface, SR = 0b, IO = 5 A, between 10% and 90% 140 SPI Interface, SR = 1b, IO = 5 A, between 10% and 90% 70 tD Output dead time VM = 24V, IO = 5 A 300 ns PWM CURRENT CONTROL (VREF) KV Transimpedance gain VREF = 3.3 V 0.635 0.66 0.705 V/A IVREF VREF Pin Leakage Current VREF = 3.3 V 0.1 µA tOFF PWM off-time TOFF = 0 or TOFF = 00b 7 μs TOFF = 1 or TOFF = 01b 16 TOFF = Hi-Z or TOFF = 10b 24 TOFF = 330kΩ to GND or TOFF = 11b 32 ΔITRIP_EXT Current trip accuracy, external VREF input 10% to 20% full-scale current -12 12 %20% to 40% full-scale current -8 5 40% to 100% full-scale current -5 4 ΔITRIP_INT Current trip accuracy, internal VREF 10% to 20% full-scale current -12 12 %20% to 40% full-scale current -9 6 40% to 100% full-scale current -6 5 IO,CH AOUT and BOUT current matching 100% full-scale current -2.5 2.5 % tBLK Current regulation blanking time SPI interface, TBLANK_TIME = 00b 1 μs H/W interface or SPI interface, TBLANK_TIME = 01b 1.5 SPI interface, TBLANK_TIME = 10b 2 SPI interface, TBLANK_TIME = 11b 2.5 tDEG Current regulation deglitch time 0.5 μs PROTECTION CIRCUITS VMUVLO VM UVLO lockout VM falling 4.1 4.25 4.35 V VM rising 4.2 4.35 4.45 VCCUVLO VCC UVLO lockout VCC connected to external voltage, VCC falling 2.7 2.8 2.9 V VCC connected to external voltage, VCC rising 2.8 2.9 3.05 VUVLO,HYS Undervoltage hysteresis Rising to falling threshold 100 mV VRST VM UVLO reset VCC = DVDD, SPI Interface, VM falling, device reset, no SPI communications 3.9 V DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

10 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Typical values are at TA = 25°C and VVM = 24 V. All limits are over recommended operating conditions, unless otherwise noted. PARAMETER TEST CONDITIONS MIN TYP MAX UNIT VCPUV Charge pump undervoltage VCP falling VVM + 2 V IOCP Overcurrent protection Current through any FET 8 A tOCP Overcurrent detection delay H/W Interface 2 μsSPI Interface, TOCP = 0b 1 SPI Interface, TOCP = 1b 2 tRETRY Overcurrent retry time 4 ms tOL Open load detection time H/W Interface 60 ms SPI Interface, OL_T = 00b 30 SPI Interface, OL_T = 01b 60 SPI Interface, OL_T = 10b 120 IOL Open load current threshold 150 mA TOTW Overtemperature warning SPI Interface, Die temperature TJ 135 150 165 °C THYS_OTW Overtemperature warning hysteresis SPI Interface, Die temperature TJ 20 °C TOTSD Thermal shutdown Die temperature TJ 150 165 180 °C THYS_OTSD Thermal shutdown hysteresis Die temperature TJ 20 °C

6.5.1 SPI Timing Requirements

tREADY SPI ready, VM > VRST 1 ms tSCLK SCLK minimum period 100 ns tSCLKH SCLK minimum high time 50 ns tSCLKL SCLK minimum low time 50 ns tSU_SDI SDI input setup time 20 ns tH_SDI SDI input hold time 30 ns tD_SDO SDO output delay time, SCLK high to SDO valid, CL = 20 pF 30 ns tSU_nSCS nSCS input setup time 50 ns tH_nSCS nSCS input hold time 50 ns tHI_nSCS nSCS minimum high time before active low 2 µs tDIS_nSCS nSCS disable time, nSCS high to SDO high impedance 10 ns www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 11 Product Folder Links: DRV8452

tHI_nSCS tSU_nSCS tSCLK tSCLKH tSCLKL MSB LSB tH_SDItSU_SDI Z ZMSB LSB tH_nSCS tDIS_nSCS X X tD_SDO nSCS SCLK SDI SDO

6.5.2 STEP and DIR Timing Requirements

Typical limits are at TJ = 25°C and VVM = 24 V. Over recommended operating conditions unless otherwise noted. NO. MIN MAX UNIT 1 ƒSTEP Step frequency 500(1) kHz 2 tWH_STEP Pulse duration, STEP high 970 ns 3 tWL_STEP Pulse duration, STEP low 970 ns 4 tSU_DIR, Mx Setup time, DIR or MODEx to STEP rising 200 ns 5 tH_DIR, Mx Hold time, DIR or Mx to STEP rising 200 ns (1) STEP input can operate up to 500 kHz, but system bandwidth is limited by the motor load. STEP DIR, Mx 4 5 2 3 Figure 6-1. STEP and DIR Timing Diagram DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

12 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

7 Detailed Description

7.1 Overview

The DRV8452 is an integrated motor-driver solution for bipolar stepper motors. The device integrates two N-channel power MOSFET H-bridges, current sense resistors, current regulation circuitry, and a microstepping indexer. The DRV8452 is capable of supporting wide supply voltage of 4.5 V to 48 V. The device is available in two packages - a 44-pin HTSSOP (DDW) package; and another 28-pin HTSSOP (PWP) package. The DDW package provides an output current up to 5-A full-scale, or 3.5-A root mean square (rms). The PWP package provides an output current up to 4-A full-scale, or 2.8-A root mean square (rms). The actual full-scale and rms current depends on the ambient temperature, supply voltage, and PCB thermal design. The PWP package with SPI interface is pin-to-pin compatible with the DRV8434S. The PWP package with H/W interface is pin-to-pin compatible with the DRV8424, DRV8426 and DRV8434. The DDW package is pin-to-pin compatible with the DRV8462. The DRV8452 integrates the auto-torque feature to reduce power loss and improve system efficiency by adjusting output current according to the load torque. The SPI interface provides various options to optimize the performance of the auto-torque algorithm for specific motor and system use case. The stall detection feature detects and reports a stall condition to the controller when the motor is obstructed or has reached an end-of-travel stop. Additionally, the standstill power saving mode reduces power loss when the motor is at holding position. The DRV8452 uses an integrated current-sense architecture which eliminates the need for two external power sense resistors, hence saving significant board space, BOM cost, design efforts and reduces significant power consumption. This architecture eliminates the power dissipated in the sense resistors by using a current mirror approach and using the internal power MOSFETs for current sensing. Optional external power sense resistors can also be connected between the PGND pins and board ground to monitor motor health and for implementing closed-loop algorithms such as Field Oriented Control. The current regulation set point is adjusted by the voltage at the VREF pin. For the SPI interface, an 8-bit register allows the controller to scale the output current without needing to scale the VREF voltage reference; and another 8-bit register allows configuration of the holding current level for the purpose of reducing power loss at motor standstill. A STEP/DIR pin interface allows an external controller to manage the direction and step rate of the stepper motor. The internal microstepping indexer can execute high-accuracy micro-stepping without requiring the external controller to manage the winding current level. The indexer is capable of full step, half step, and 1/4,1/8, 1/16, 1/32, 1/64, 1/128, and 1/256 microstepping. High microstepping contributes to significant audible noise reduction and smooth motion. The automatic microstepping mode interpolates the input step frequency to high resolution, thereby improving current regulation and reducing audible noise while running with a low frequency step input from the controller. The custom microstepping table allows adjusting the current waveform to the needs of a particular motor. Stepper motor drivers need to re-circulate the winding current by implementing several types of decay modes, such as slow decay, mixed decay and fast decay. The DRV8452 supports smart tune decay modes. The smart tune is an innovative decay mechanism that automatically adjusts for optimal current regulation performance agnostic of supply voltage and motor speed variations and aging effects. Smart tune Ripple Control uses a variable off-time ripple current control scheme to minimize distortion of the motor winding current. Smart tune Dynamic Decay uses a fixed off-time dynamic fast decay percentage scheme. Along with the smart tune decay modes, the DRV8452 also features a silent step decay mode for noiseless operation at standstill and low speeds of rotation. The device integrates a spread spectrum clocking feature for both the internal digital oscillator and internal charge pump. This feature minimizes the electromagnetic emissions from the device. A low-power sleep mode is included which allows the system to save power when not actively driving the motor. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 13 Product Folder Links: DRV8452

7.2 Functional Block Diagram

0.1 F Power Charge Pump DVDD Regulator DVDD 1 F STEP DIR ENABLE nSLEEP Control Inputs VREF Analog Input Smart tune Gate Drivers VM Current Sense VM Current Sense SINE DAC AOUT1 AOUT2 PGNDA VVREF Stepper Motor Fault Output nFAULT DVDD Protection Overcurrent PPAD GND Undervoltage Open Load Overtemperature RnFAULT Microstepping Indexer 1 µF VVREF BOUT1 BOUT2 PGNDB Gate Drivers VM Current Sense VM Current Sense SINE DAC VVREF KV KV 0.1 F VCCnHOME RnHOME MODE = 1 Indexer Position DVDD SDI SCLK SDO nSCS SPI VCC VREF RREF2 RREF1 VCC Silent step Decay Auto-torque Automatic Microstepping Customizable Microstepping Standstill Power Saving DIGITAL CORE Stall Detection VCC Figure 7-1. DRV8452 Block Diagram with SPI Interface DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

14 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

7.3 Functional Block Diagram

0.1 F Power Charge Pump DVDD Regulator DVDD 1 F STEP DIR ENABLE nSLEEP DECAY0 DECAY1 Control Inputs VREF Analog InputVREF Digital Core Smart tune Gate Drivers VM Current Sense VM Current Sense SINE DAC AOUT1 AOUT2 PGNDA VVREF Stepper Motor Fault Output nFAULT DVDD Protection Overcurrent PPAD GND Undervoltage Open Load Overtemperature RnFAULT Microstepping Indexer 1 µF VVREF BOUT1 BOUT2 PGNDB Gate Drivers VM Current Sense VM Current Sense SINE DAC VVREF KV KV RREF2 RREF1 VCC TOFF 0.1 F VCCnHOME RnHOME MODE = 0 Indexer Position DVDD VCC Figure 7-2. DRV8452 Block Diagram with Hardware Interface www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 15 Product Folder Links: DRV8452

7.4 Feature Description

Table 7-1 lists the recommended external components for the DRV8452. Table 7-1. External Components COMPONENT PIN 1 PIN 2 RECOMMENDED CVM1 VM PGNDA X7R, 0.01-µF, VM-rated ceramic capacitors CVM2 VM PGNDB X7R, 0.01-µF, VM-rated ceramic capacitors CVM3 VM PGNDA Bulk, VM-rated capacitor CVCP VCP VM X7R, 1-µF, 16-V ceramic capacitor CSW CPH CPL X7R, 0.1-µF, VM-rated ceramic capacitor CDVDD DVDD GND X7R, 1-µF, 6.3-V ceramic capacitor CVCC VCC GND X7R, 0.1-µF, 6.3-V ceramic capacitor RnFAULT DVDD or VCC nFAULT 10-kΩ resistor RnHOME (only for DDW) DVDD or VCC nHOME 10-kΩ resistor RREF1 VREF DVDD or VCC Resistor to set chopping current. RREF2 VREF GND

7.4.1 Operation Interface

The DRV8452 can operate with hardware (H/W) pin interface or SPI interface. When operating with SPI interface, the device supports additional features and detailed diagnostics, as shown in Table 7-4. For the DDW package option, the logic-level MODE pin latches the operating interface information at power up or after nSLEEP cycling -

  • If the MODE pin is grounded at this time, the device operates with H/W pin interface.
  • If the MODE pin is logic high at this time, the device operates with SPI interface.
  • Do not change MODE pin logic level on the fly after power up or after nSLEEP cycling. The functionality of five pins depend on the interface of operation, as shown in Table 7-2 and Table 7-3 - Table 7-2. Pin function, DDW package Pin Number MODE = 0, H/W interface MODE = 1, SPI Interface

34 M0 nSCS

35 TOFF Reserved

36 DECAY1 SDO

37 DECAY0 SDI

38 M1 SCLK

Table 7-3. Pin function, PWP package Pin Number DRV8452SPWPR (SPI Interface) DRV8452PWPR (H/W Interface) 18 nSCS M0

19 VCC TOFF

20 SDO DECAY1

21 SDI DECAY0

22 SCLK M1

SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

16 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Table 7-4 compares the feature set and diagnostic features for the two operating interfaces - Table 7-4. Feature Set Difference Feature H/W interface SPI interface Smart tune Yes Yes Up to 1/256 microstepping Yes Yes Separate logic supply (VCC) Yes Yes nHOME output Yes Yes nFAULT output Yes Yes Automatic microstepping No Yes Customizable microstepping No Yes Indexer output No Yes Internal 3.3V reference voltage No Yes Dual STEP active edge No Yes Silent step decay No Yes Auto-torque No Yes Standstill power saving No Yes Spread spectrum No Yes Protection features VM and VCP UVLO Yes Yes VCC Power on Reset Yes Yes Overcurrent Protection Yes Yes Open-load detection Yes Yes Thermal shutdown Yes Yes Stall detection No Yes Overtemperature warning No Yes Note For pre-production samples, if the device is operating with H/W interface, and the M0 pin is Hi-z at power-up, then the nFAULT pin will stay low even if there are no faults. To release the nFAULT, the user has to apply an nSLEEP reset pulse. This behavior will not be present in the production samples - nFAULT will be pulled-high after power- up if there are no faults.

7.4.2 Stepper Motor Driver Current Ratings

Stepper motor drivers can be classified using three different numbers to describe the output current: peak, RMS, and full-scale.

7.4.2.1 Peak Current Rating

The peak current in a stepper driver is limited by the overcurrent protection trip threshold I OCP. In general the minimum value of IOCP specifies the peak current rating of the stepper motor driver. For the DRV8452, the peak current rating is 8 A per bridge. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 17 Product Folder Links: DRV8452

7.4.2.2 RMS Current Rating

The RMS current is determined by the thermal considerations of the IC. The RMS current is calculated based on the RDS(ON), rise and fall time, PWM frequency, device quiescent current, and package thermal performance in a typical system at 25°C. The actual operating RMS current may be higher or lower depending on heatsinking and ambient temperature. For the DRV8452 in DDW package, the RMS current rating is 3.5 A per bridge. For the PWP package, the RMS current rating is 2.8 A per bridge.

7.4.2.3 Full-Scale Current Rating

The full-scale current describes the top of the sinusoid current waveform while microstepping. Because the sinusoid amplitude is related to the RMS current, the full-scale current is also determined by the thermal considerations of the device. The full-scale current rating is approximately √2 × IRMS for a sinusoidal current waveform, and IRMS for a square wave current waveform (full step). Output Current AOUT Step Input BOUT Full-scale current RMS current Figure 7-3. Full-Scale and RMS Current

7.4.3 PWM Motor Drivers

The DRV8452 has drivers for two full H-bridges to drive the two windings of a bipolar stepper motor. Figure 7-4 shows the block diagram of the circuitry. Gate Drivers VM Current Sense VM Current Sense AOUT1 AOUT2 PGNDA Microstepping and Current Regulation Logic Figure 7-4. PWM Motor Driver Block Diagram DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

18 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

7.4.4 Microstepping Indexer

Built-in indexer logic in the device allows a number of different step modes. The MICROSTEP_MODE bits in the SPI register or the M0 and M1 pins are used to configure the step mode as shown in Table 7-5. Table 7-5. Microstepping Indexer Settings MODE = 1 MODE = 0 MICROSTEP_MODE M0 M1 STEP MODE 0000b 0 0 Full step (2-phase excitation) with 100% current 0001b 0 330 kΩ to GND Full step (2-phase excitation) with 71% current 0010b 1 0 Non-circular 1/2 step 0011b Hi-Z 0 1/2 step 0100b 0 1 1/4 step 0101b 1 1 1/8 step 0110b Hi-Z 1 1/16 step 0111b 0 Hi-Z 1/32 step 1000b Hi-Z 330kΩ to GND 1/64 step 1001b Hi-Z Hi-Z 1/128 step 1010b 1 Hi-Z 1/256 step Table 7-6 shows the relative current and step directions for full-step (71% current), 1/2 step, 1/4 step and 1/8 step operation. Higher microstepping resolutions follow the same pattern. The AOUT current is the sine of the electrical angle and the BOUT current is the cosine of the electrical angle. Positive current is defined as current flowing from the xOUT1 pin to the xOUT2 pin while driving. Table 7-6. Relative Current and Step Directions 1/8 STEP 1/4 STEP 1/2 STEP FULL STEP 71% AOUT CURRENT (% FULL-SCALE) BOUT CURRENT (% FULL-SCALE) ELECTRICAL ANGLE (DEGREES) 1 1 1 0% 100% 0.00 2 20% 98% 11.25 3 2 38% 92% 22.50 4 56% 83% 33.75 5 3 2 1 71% 71% 45.00 6 83% 56% 56.25 7 4 92% 38% 67.50 8 98% 20% 78.75 9 5 3 100% 0% 90.00 10 98% -20% 101.25 11 6 92% -38% 112.50 12 83% -56% 123.75 13 7 4 2 71% -71% 135.00 14 56% -83% 146.25 15 8 38% -92% 157.50 16 20% -98% 168.75 17 9 5 0% -100% 180.00 www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 19 Product Folder Links: DRV8452

Table 7-6. Relative Current and Step Directions (continued) 1/8 STEP 1/4 STEP 1/2 STEP FULL STEP 71% AOUT CURRENT (% FULL-SCALE) BOUT CURRENT (% FULL-SCALE) ELECTRICAL ANGLE (DEGREES) 19 10 -38% -92% 202.50 21 11 6 3 -71% -71% 225.00 23 12 -92% -38% 247.50 25 13 7 -100% 0% 270.00 26 -98% 20% 281.25 27 14 -92% 38% 292.50 28 -83% 56% 303.75 29 15 8 4 -71% 71% 315.00 30 -56% 83% 326.25 31 16 -38% 92% 337.50 32 -20% 98% 348.75 Table 7-7 shows the full step operation with 100% full-scale current. This stepping mode consumes more power than full-step mode with 71% current, but provides a higher torque at high motor RPM. Table 7-7. Full Step with 100% Current FULL STEP 100% AOUT CURRENT (% FULL-SCALE) BOUT CURRENT (% FULL-SCALE) ELECTRICAL ANGLE (DEGREES) 1 100 100 45 2 100 -100 135 3 -100 -100 225 4 -100 100 315 Table 7-8 shows the noncircular 1/2–step operation. This stepping mode consumes more power than circular 1/2-step operation, but provides a higher torque at high motor RPM. Table 7-8. Non-Circular 1/2-Stepping Current NON-CIRCULAR 1/2-STEP AOUT CURRENT (% FULL-SCALE) BOUT CURRENT (% FULL-SCALE) ELECTRICAL ANGLE (DEGREES) 1 0 100 0 2 100 100 45 3 100 0 90 4 100 –100 135 5 0 –100 180 6 –100 –100 225 7 –100 0 270 8 –100 100 315 When operating with SPI interface, the device allows stepping and direction change over SPI. Four bits are dedicated for this purpose -

  • SPI_DIR: – When this bit is '0', the driver changes direction based on DIR pin inputs. – If this bit is '1', the direction changes depend on the DIR bit. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

20 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

  • SPI_STEP: – When this bit is '0', the stepping depends on the STEP pin inputs. – If this bit is '1', the step changes depend on the STEP bit.
  • DIR: When SPI_DIR = '1' - – If DIR = '1', motor moves in the forward direction – If DIR = '0', motor moves in the reverse direction.
  • STEP: When SPI_STEP = '1' - – If STEP = '1', the indexer advances by one step. – STEP bit is self-clearing, it becomes '0' after writing '1' to it. When operating with the SPI interface, depending on the STEP_EDGE bit, STEP active edge can be either rising edge or both rising and falling edge, as shown in Table 7-9. When configured with H/W interface, the STEP active edge is only the rising edge. For applications that need to run at high input STEP rate, configuring both edges as active edge reduces controller overhead by half, because the input STEP rate is effectively doubled. Table 7-9. STEP Active Edge MODE STEP_EDGE STEP Active Edge 1 0b (default) Rising edge 1 1b Rising edge and falling edge

0 X Rising edge

At each active edge of the STEP input the indexer advances to the next state in the table. The direction shown is with the DIR pin logic high. If the DIR pin is logic low, the sequence table is reversed. After power-up, after exiting logic undervoltage lockout, or after exiting sleep mode, the indexer moves to an initial excitation state (home position) of 45° electrical angle, corresponding to 71% of full-scale current in both coils. All the registers are restored to their deafult values in such scenario. Note

  • The production samples will feature an INDEX_RESET bit located in CTRL1 register bit 5. This bit will reset the indexer to 45° electrical angle, but the contents of the registers will not change. In pre-production samples, this bit will be reserved.
  • If the step mode is changed dynamically while stepping, the indexer advances to the next valid state for the new step mode setting at the active edge of STEP. If the STEP input frequency is jittery, the device filters the signal for the purpose of stall detection. The FRQ_CHG and STEP_FRQ_TOL bits program the filter setting, as shown in Table 7-10. 2% filtering means up to 2% jitter around the center frequency will be filtered out to generate a clean STEP signal for internal circuits to detect motor stall. Table 7-10. STEP frequency filtering FRQ_CHG STEP_FRQ_TOL Filtering 0 (default) 00 1% 01 (default) 2% 10 4% 11 6%

1 Don't care No filtering

7.4.5 Indexer Output

  • A 10-bit INDEX_POS register indicates actual position in the microstep table for coil A current. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 21 Product Folder Links: DRV8452
  • 8 bit CUR_A register and CUR_A_SIGN bit indicate the microstep current for motor coil A for the position indicated by the INDEX_POS bits.
  • 8 bit CUR_B register and CUR_B_SIGN bit indicate the microstep current for motor coil B.
  • When the microstep indexer advances within the table through each possible value of the INDEX_POS bits, the actual current values in the motor coils can be calculated by - – Coil A current = IFS x sin (90° x CUR_A / 255) – Coil B current = IFS x sin (90° x CUR_B / 255) – Current will be positive if the corresponding sign bit is '1' and negative if the sign bit is '0'
  • CUR_A and CUR_B become initialized to 0 and 255 respectively whenever INDEX_POS passes zero. The following table shows the outputs of the indexer registers for a current waveform corresponding to 1/256 microstepping. Table 7-11. Indexer Output Table Current Quadrant INDEX_POS CUR_A CUR_A_SIGN CUR_B CUR_B_SIGN First (0° -> 90°) 0 -> 255 0 -> 255 1 255 -> 0 1 Second (90° -> 180°) 256 -> 511 255 -> 0 1 0 -> 255 0 Third (180° -> 270°) 512 -> 767 0 -> 255 0 255 -> 0 0 Fourth (270° -> 360°) 768 -> 1023 255 -> 0 0 0 -> 255 1 The Indexer outputs together with the nHOME signal allow determination of the motor position within the electrical wave. They can be compared with an encoder output to detect discrepancies in the movement of the motor - such as detecting step loss. Note In production samples, the INDEX_POS bits will output the actual coil A current -> sin (90° x CUR_A / 255). 7.4.5.1 nHOME Output For the DDW package, when the microstepping indexer reaches the home position (electrical angle of 45°), corresponding to 71% of full-scale current in both coils, the open-drain nHOME output is pulled low. At all other times, the nHOME output will be pulled high. When the device operates with SPI interface, additionally the NHOME bit in SPI register goes low when the indexer reaches home position for both DDW and PWP packages. Therefore, the nHOME output gives one low pulse per electrical rotation, i.e. one pulse per each four fullsteps, as shown in Figure 7-5. The nHOME low pulse thus corresponds to a defined position of the motor for every four fullsteps. A more precise homing of the motor can be achieved by combining nHOME with a mechanical home switch. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

22 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Pull up the nHOME to a 5-V, 3.3-V or 1.8-V supply using a pull-up resistor. For a 5-V pullup, the nHOME pin can be tied to the DVDD pin with a resistor. For a 3.3-V or 1.8-V pullup, an external supply must be used. Traces from top to bottom: BOUT2, BOUT1, coil B current, coil A current, nHOME Figure 7-5. nHOME Pin Waveform

7.4.6 Automatic Microstepping Mode

When the DRV8452 is operating with SPI interface, automatic microstepping mode interpolates the input step pulses to generate a current waveform corresponding to higher resolution microstep. This results in smooth sinusoidal current and noiseless operation at any step frequency. The EN_AUTO bit should be '1' to enable the automatic microstepping mode. Motor Angle STEP Figure 7-6. Automatic Microstepping Interpolation Figure 7-6 shows increment in motor angle with and without automatic microstepping. Without automatic microstepping (red plot), the motor angle increments by a large amount on every step input active edge. Automatic microstepping (green plot) results in a much smoother change in motor angle. The DRV8452 supports interpolation to 1/32, 1/64, 1/128 or 1/256 microstepping levels, configured by the RES_AUTO bits as shown in Table 7-12. The interpolation setting can be changed on the fly. Table 7-12. Automatic Microstepping Interpolation Level RES_AUTO Interpolation 00 (default) 1/256 01 1/128 10 1/64 11 1/32 The following scopeshots show both coil currents and the smooth transition between half-step mode and automatic microstepping mode by writing '1' and '0' respectively to the EN_AUTO bit. Notice that the step frequency is same in both half-step and 1/256 automatic microstepping modes. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 23 Product Folder Links: DRV8452

Transition from half-step mode to 1/256 automatic microstepping Transition from 1/256 automatic microstepping to half-step mode STEP Motor Angle 1 2 3 Figure 7-7. Automatic Microstepping with Changing STEP Frequency As shown in Figure 7-7, the interpolation is done based on the time between the two previous step pulses. The previous interval time is interpolated to equal divisions, depending on the RES_AUTO bit setting. When input step frequency reduces from previous interval (shown in segment '1'), the motor holds its position till the next STEP active edge occurs. Device will go to standstill power saving mode if the EN_STSL bit is '1', and the next active edge does not come before t STSL_DLY expires. Standstill power saving mode is exited on the next STEP active edge. When step frequency increases from previous interval (shown in segment '2'), the motor angle auto-corrects when the next STEP active edge comes, because the indexer moves to a position corresponding to the STEP input. In segment '3', the motor angle is incremented at a faster rate, corresponding to the step frequency of segment '2'. If automatic microstepping is disabled, the system controller will be forced to output high frequency STEP signals to generate current waveforms corresponding to 1/256 microstep. When automatic microstepping is enabled, smooth current waveform can be generated by low frequency STEP signals. This drastically reduces controller overhead and is beneficial for applications such as 3D printer, factory automation and medical. It should be ensured that the interpolated frequency does not fall in the resonant frequency band of the stepper motor. The frequency of the STEP input in automatic microstepping mode should not exceed 300 kHz.

7.4.7 Custom Microstepping Table

The performance and audible noise of any stepper motor system depends on the torque ripple generated by both the motor and the load. The torque ripple is defined by the variation in torque at each microstep. For most stepper motors, the standard sinusoidal microstep indexer is sufficient to achieve acceptable torque ripple and a good performance. However, for some motor and load torque combinations, altering the current profile can reduce torque ripple, resulting in lower vibration and audible noise. When properly programmed, the customized current waveform DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

24 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

ensures equally distanced microstep positions with constant torque and therefore also the best positional accuracy. For example, in case of permanent magnet motors, variations in torque are more prominent due to larger step angle (3.6° to 18°) than that of hybrid motors (0.9° or 1.8°). Due to fewer number of stator teeths, less amount of flux interacts between the stator teeth and the rotor when the rotor is in between two stator teeths. If the current level is increased at these intermediate positions, the torque ripple will be lower compared to the default sinusoidal indexer. The DRV8452 features a lookup table for tailoring the microstepping current profile to suit the requirements of a specific motor. The modified current profile is used in place of the default sinusoidal profile by writing '1' to the EN_CUSTOM bit. The frequency of the STEP input in custom microstepping mode should not exceed 300 kHz. The details of the interpolation process is described below -

  • The user should program the current (% of TRQ_DAC) corresponding to the first quadrant of coil A current in a 1/8 microstepping setting.
  • These current values are stored in CUSTOM_CURRENT1 to CUSTOM_CURRENT8 registers. electrical angles.
  • The current value for 0° position is assumed to be zero.
  • The nine current values (including 0% full-scale current) are interpolated to a total of 256 points using a piecewise-linear approach to build the complete current waveform. The interpolated waveform always corresponds to 1/256 microstep, irrespective of the programmed microstepping mode.
  • The values for the first quadrant are then mirrored and repeated for the other three quadrants of coil A and again for the four quadrants of coil B current to construct the complete current waveform. Table 7-13 shows an example of the user inputs. Table 7-13. Custom Microstepping Table Values Position (degrees) Sine Indexer Value Modified Value (CUSTOM_CURRENTx) 0 0 0 11.25 49.7 24 22.5 97.6 56 33.75 141.7 96 45 180.3 152 56.25 212 192 67.5 235.6 224 78.75 250.1 240 90 255 255 Figure 7-8 shows the corresponding modified current waveform (red plot) of coil A for one full electrical angle, compared to waveform generated by sine indexer (blue plot). www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 25 Product Folder Links: DRV8452

Figure 7-8. Customizable Microstepping

7.4.8 Current Regulation

The current through the motor windings is regulated by a PWM current-regulation circuit. When an H-bridge is enabled, current rises through the winding at a rate dependent on the DC voltage, inductance of the winding, and the magnitude of the back EMF present. When the current hits the current regulation threshold, the bridge enters a decay mode for the OFF time to decrease the current. After the off-time expires, the bridge is re-enabled, starting another PWM cycle. ITRIP Motor Current tBLANK tOFF Figure 7-9. Current Chopping Waveform The PWM regulation current is set by a comparator which monitors the voltage across the current sense MOSFETs in parallel with the low-side power MOSFETs. When the device is configured with H/W interface, the current sense MOSFETs are biased with a reference current that is the output of a current-mode sine-weighted DAC whose full-scale reference current is set by the voltage at the VREF pin. When operating with SPI interface, two registers (TRQ_DAC and ISTSL) can further scale the reference current. Use Equation 1 to calculate the full-scale regulation current for H/W interface. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

26 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

IFS (A) = VREF (V) / KV (V/A) (1) For the SPI interface, the 8-bit TRQ_DAC register further scales the full-scale current as follows - IFS (A) = VREF (V) x TRQ_DAC / KV (V/A) (2) Table 7-14. TRQ_DAC Settings TRQ_DAC CURRENT SCALAR 11111111b 100% 11111110b 99.61% 11111101b 99.22% 11111100b 98.83% 00000000b 0.39% Another 8-bit register ISTSL programs the holding current (I HOLD) when STEP pulses are not applied and the motor is being held at same position. Transitioning to a lower value of holding current reduces motor and driver power loss. See Standstill Power Saving Mode for details. IHOLD (A) = VREF (V) x ISTSL / KV (V/A) (3) Table 7-15. ISTSL Settings ISTSL Holding Current Value 11111111b 100% 11111110b 99.61% 11111101b 99.22% 11111110b 98.83% 00000000b 0.39% Note Always set ISTSL to a value lower than the TRQ_DAC value.

7.4.8.1 Internal Reference Voltage

When operating with the SPI interface, the DRV8452 features an internal 3.3V reference voltage by writing '1' to the VREF_INT_EN bit. The voltage on the VREF pin will be ignored in this case, and the VREF pin can be left open or connected to ground. The full-scale current and the holding current will be calculated as - IFS (A) = 3.3 V x TRQ_DAC / KV (V/A) (4) IHOLD (A) = 3.3 V x ISTSL / KV (V/A) (5) Using the internal 3.3V as reference for setting full-scale current and holding current will save BOM cost by eliminating the two resistors connected to the VREF pin. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 27 Product Folder Links: DRV8452

The VREF_INT_EN bit is located in ATQ_CTRL18 register bit 5 in pre-production samples. For production samples, the VREF_INT_EN bit will be located in CTRL13 register bit 1.

7.4.9 Current Regulation Decay Modes

During PWM current chopping, the H-bridge is enabled to drive through the motor winding until the PWM current chopping threshold is reached. This is shown in Figure 7-10, Item 1. Once the chopping current threshold is reached, the H-bridge can operate in two different states, fast decay or slow decay. In fast decay mode, as soon as the PWM chopping current level is reached, the H-bridge reverses state by switching on the opposite arm MOSFETs to allow the winding current to flow in the opposite direction. As the winding current approaches zero, the H-bridge is disabled to prevent further reverse current flow. Fast decay mode is shown in Figure 7-10 , item 2. In slow decay mode, the winding current is re-circulated by enabling both low-side MOSFETs in the H-bridge. This is shown in Figure 7-10, Item 3. xOUT1 xOUT2 Forward drive Slow decay VM

3 Fast decay (Reverse drive)

Figure 7-10. Decay Modes The decay mode is selected by the DECAY register or the DECAY0 and DECAY1 pins, as shown in Table 7-16. The decay modes can be changed on the fly. In full step and noncircular 1/2-step, the decay mode corresponding to decreasing steps is always used. Table 7-16. Decay Mode Settings SPI Interface H/W Interface INCREASING STEPS DECREASING STEPS DECAY DECAY0 DECAY1 000b Hi-Z 1 Reserved 001b 1 1 Slow decay Mixed decay: 30% fast 010b 0 Hi-Z Slow decay Mixed decay: 60% fast 011b 1 Hi-Z Slow decay Fast decay 100b 1 0 Mixed decay: 30% fast Mixed decay: 30% fast 101b Hi-Z 0 Mixed decay: 60% fast Mixed decay: 60% fast 110b 0 0 Smart tune Dynamic Decay Smart tune Dynamic Decay DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

28 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

7.4.9.1 Slow Decay for Increasing Current, Fast Decay for Decreasing Current

Decreasing Phase Current (A) ITRIP tOFF tBLANK tDRIVE tOFF tBLANK tDRIVE tOFF tBLANK tDRIVE Increasing Phase Current (A) ITRIP tBLANK tDRIVE tOFFtBLANK tDRIVE Please note that these graphs are not the same scale; tOFF is the same tOFF Figure 7-12. Slow/Fast Decay Mode During fast decay, the polarity of the H-bridge is reversed. The H-bridge will be turned off as current approaches zero in order to prevent current flow in the reverse direction. In this mode, fast decay only occurs during decreasing current. Slow decay is used for increasing current. Fast decay exhibits the highest current ripple of the decay modes for a given t OFF. Transition time on decreasing current steps is much faster than slow decay since the current is allowed to decrease much faster. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

30 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

7.4.9.2 Slow Decay for Increasing Current, Mixed Decay for Decreasing Current

Decreasing Phase Current (A) ITRIP Increasing Phase Current (A) ITRIP tBLANK tDRIVE tOFF tBLANK tDRIVE tFAST tBLANK tOFF tFAST tDRIVE tBLANK tDRIVE tOFF tOFF tBLANK tDRIVE Figure 7-13. Slow-Mixed Decay Mode Mixed decay begins as fast decay for an initial duration of the t OFF, followed by slow decay for the remainder of the tOFF time. Mixed decay only occurs during decreasing current. Slow decay is used for increasing current. This decay mode exhibits the same current ripple as slow decay mode does for increasing current, because for increasing current, only slow decay is used in this mode. For decreasing current, the ripple is larger than slow decay, but smaller than fast decay. On decreasing current steps, mixed decay settles to the new ITRIP level faster than slow decay. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 31 Product Folder Links: DRV8452

7.4.9.3 Mixed Decay for Increasing and Decreasing Current

Decreasing Phase Current (A) ITRIP tBLANK tDRIVE Increasing Phase Current (A) ITRIP tBLANK tDRIVEtDRIVE tOFF tBLANK tDRIVE tFAST tBLANK tOFF tFAST tDRIVE tOFFtOFF Figure 7-14. Mixed-Mixed Decay Mode Mixed decay begins as fast decay for an initial duration of the t OFF time, followed by slow decay for the remainder of tOFF time. In this mode, mixed decay occurs for both increasing and decreasing current steps. This mode exhibits ripple larger than slow decay, but smaller than fast decay. On decreasing current steps, mixed decay settles to the new ITRIP level faster than slow decay. When the winding current is held static for a long time (for example while no STEP input is present) or at very low step rates, slow decay may not properly regulate the current because back-EMF will be small or absent across the motor windings. In this case the motor current can rise rapidly and require an extremely long off-time to regulate the current. Increasing and decreasing current mixed decay mode allows the current to stay in regulation when no back-EMF is present across the motor windings.

7.4.9.4 Smart tune Dynamic Decay

The smart tune current regulation schemes are advanced current-regulation control methods compared to traditional fixed off-time current regulation schemes. Smart tune current regulation schemes help the stepper motor driver adjust the decay scheme based on operating factors such as the ones listed as follows:

  • Motor winding resistance and inductance
  • Motor aging effects
  • Motor dynamic speed and load
  • Motor supply voltage variation
  • Motor back-EMF difference on rising and falling steps
  • Step transitions
  • Low-current versus high-current dI/dt The device provides two different smart tune current regulation modes, named smart tune Dynamic Decay and smart tune Ripple Control. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

32 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Decreasing Phase Current (A) ITRIP tBLANK tDRIVE tBLANK tDRIVE Increasing Phase Current (A) ITRIP tBLANK tDRIVE tOFF tOFF tBLANK tDRIVE tFAST tOFF tBLANK tDRIVE tFAST Figure 7-15. Smart tune Dynamic Decay Mode Smart tune Dynamic Decay greatly simplifies the decay mode selection by automatically configuring the decay mode between slow, mixed, and fast decay. In mixed decay, smart tune dynamically adjusts the fast decay percentage of the total mixed decay time. This feature eliminates motor tuning by automatically determining the best decay setting that results in the lowest ripple for the motor. The decay mode setting is optimized iteratively each PWM cycle. If the motor current overshoots the target trip level, then the decay mode becomes more aggressive (add fast decay percentage) on the next cycle to prevent regulation loss. If a long drive time must occur to reach the target trip level, the decay mode becomes less aggressive (remove fast decay percentage) on the next cycle to operate with less ripple and more efficiently. On falling steps, smart tune Dynamic Decay automatically switches to fast decay to reach the next step quickly. Smart tune Dynamic Decay is optimal for applications that require minimal current ripple but want to maintain a fixed frequency in the current regulation scheme. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 33 Product Folder Links: DRV8452

7.4.9.5 Smart tune Ripple Control

Decreasing Phase Current (A) ITRIP tBLANK tDRIVE tOFF tBLANK tDRIVE Increasing Phase Current (A) ITRIP tBLANK tDRIVE tOFF IVALLEY tOFF tOFFtBLANK tDRIVE tBLANK tDRIVE IVALLEY tBLANK tDRIVE tOFF Figure 7-16. Smart tune Ripple Control Decay Mode Smart tune Ripple Control operates by setting an I VALLEY level along with the I TRIP level. When the current level reaches ITRIP, instead of entering slow decay until the t OFF time expires, the driver enters slow decay until IVALLEY is reached. Slow decay operates similar to slow/slow decay where both low-side MOSFETs are turned on allowing the current to recirculate. In this mode, t OFF is variable depending on the current level and operating parameters. The ripple current in smart tune ripple control mode is programmed by the RC_RIPPLE[1:0] bits or the TOFF pin, as shown below. Table 7-17. Current Ripple Settings MODE = 0, H/W Interface MODE = 1, SPI Interface Current Ripple at a specific microstep levelTOFF RC_RIPPLE 0 00b 25 mA + 1% of ITRIP 1 01b 25 mA + 2% of ITRIP Hi-Z 10b 25 mA + 4% of ITRIP 330kΩ to GND 11b 25 mA + 6% of ITRIP The ripple control method allows much tighter regulation of the current level, thereby increasing motor efficiency and system performance. Smart tune Ripple Control can be used in systems that can tolerate a variable off-time regulation scheme to achieve low current ripple with current regulation. Select a lowest possible ripple current setting that ensures the PWM frequency does not fall in the audible range (< 20 kHz).

7.4.9.6 PWM OFF Time

The TOFF bits or the TOFF pin configure the PWM OFF time for all decay modes except smart tune ripple control and silent step decay modes, as shown in Table 7-18. The OFF time settings can be changed on-the-fly. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

34 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Table 7-18. OFF Time Settings SPI Interface H/W Interface OFF Time TOFF TOFF 00b 0 7 µs 01b 1 16 µs 10b Hi-Z 24 µs 11b 330kΩ to GND 32 µs

7.4.9.7 Current Regulation Blanking Time and Deglitch Time

After the current is enabled (start of drive phase) in an H-bridge, the current sense comparator is ignored for a period of time (tBLK) before enabling the current-sense circuitry. The blanking time also sets the minimum drive time of the PWM.

  • When the device operates with hardware interface, the blanking time is fixed at 1.5 μs.
  • When the device is operating with SPI interface, the blanking time can be programmed by the TBLANK_TIME bits, with a default value of 1.5 μs. Table 7-19. TBLANK_TIME Settings TBLANK_TIME Blanking Time 00 1 μs 01 1.5 μs 10 2 μs 11 2.5 μs When the current is close to the ITRIP level, a 0.5 μs deglitch time ensures proper current regulation.

7.4.10 Current Sensing with External Resistor

PWM current regulation is based on the voltage sensed across the internal sense resistor of the DRV8452. Optional external resistors can be placed between the PGND pins and system ground (or in series with the VM pins) to sense the coil current, as shown in Figure 7-17. The DRV8452 has two PGNDA pins and two PGNDB pins - one pair for each H-bridge. So, the current of each stepper motor coil can be sensed separately by placing sense resistors between PGND pins and system ground. All the VM pins are shorted internally - so if a sense resistor is placed in the VM path, it will sense the combined current of both the H-bridges. The voltage drop across the external sense resistor should not exceed 300 mV. The sensed coil current can be processed to monitor motor health, or used to generate necessary signals in a field-oriented-control loop to improve overall system efficiency. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 35 Product Folder Links: DRV8452

(Motor Health or FOC) Figure 7-17. Current Sensing with External Resistor No current flows through the sense resistor during the slow decay, so the sense resistor conducts less than the coil RMS current. Place the sense resistors as close as possible to the corresponding IC pins. Use a symmetrical sense resistor layout to ensure good matching. Low-inductance sense resistors should be used to prevent voltage spikes and ringing. For optimal performance, the sense resistor should be a surface-mount resistor rated for high enough power.

7.4.11 Silent step decay mode

Conventional peak current mode control looks at instantaneous current in the sensing MOSFETs to determine drive and decay durations. As a result, the motor driver reacts to instantaneous inaccuracies in the system. These sudden changes in current cause audible noise from the motor. To ensure noiseless stepper motor operation, the DRV8452 features the silent step decay mode. The silent step is a voltage mode PWM regulation scheme to remove noise due to PWM switching at standstill and low speeds. Thus, silent step operated stepper motor applications are highly suitable for applications such as 3D printer, medical equipment and factory automation. Note When the device is operating in silent step decay mode, open-load fault detection and stall detection are not supported, and spread spectrum feature is disabled. The silent step loop is designed with low bandwidth, therefore at moderate to high motor speeds, the decay mode can be switched back to one of the conventional current-mode decay schemes programmed by the DECAY bits. Transition from silent step to another decay mode is immediate, whereas the transition from other decay modes to silent step happens at the boundary of electrical half-cycles. Figure 7-18 shows the block diagram of the silent step decay mode implementation - DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

36 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

(KP, KI, KP_DIV_SEL, KI_DIV_SEL) MStepper Driver Current Sense Coil Current Ramp Generator FPWM Figure 7-18. Silent step block diagram Table 7-20 shows the SPI register parameters related to the silent step decay mode. Table 7-20. Silent step Parameter Table Parameter Description EN_SS When EN_SS bit is '1', silent step decay mode is enabled. Device starts operating with silent step after one zero cross each for currents in coil A and coil B. SS_PWM_FREQ Represents the PWM frequency (FPWM) in silent step decay mode. '00' = 25 kHz '01' = 33 kHz '10' = 42 kHz '11' = 50 kHz Default value of FPWM is 25 kHz. Higher PWM frequency results in higher switching loss. SS_KP Represents the proportional gain of the silent step PI controller. Has a range of 0 to 127. SS_KI Represents the integral gain of the silent step PI controller. Has a range of 0 to 127. SS_KP_DIV_SEL Divider factor for KP. Actual KP = SS_KP / SS_KP_DIV_SEL. 000b - SS_KP/32 001b - SS_KP/64 010b - SS_KP/128 011b - SS_KP/256 100b - SS_KP/512 101b - SS_KP/16 110b - SS_KP SS_KI_DIV_SEL Divider factor for KI. Actual KI = SS_KI / SS_KI_DIV_SEL. 000b - SS_KI/32 001b - SS_KI/64 010b - SS_KI/128 011b - SS_KI/256 100b - SS_KI/512 101b - SS_KI/16 110b - SS_KI SS_THR Programs the frequency at which the device transitions from silent step decay mode to another decay mode programmed by the DECAY bits. This frequency corresponds to the frequency of the sinusoidal current waveform. 00000001b = 2 Hz 00000010b = 4 Hz 11111111b = 510 Hz To convert the SS_THR threshold to STEP frequency (f STEP) for a specified microstepping setting, the following formula should be used - www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 37 Product Folder Links: DRV8452

fSTEP = (SS_THR * 1000 * usm) / 256 (6) Where usm corresponds to the number of microsteps (4, 16, 256 etc.). When the device is operating with custom microstepping mode, use usm = 256 in Equation 6 when calculating the STEP frequency. The gain vs frequency plot of the silent step loop is shown in Figure 7-18 - Loop Gain (dB) Frequency Pole at Origin UGB Motor Pole PI Zero Attenuated FrequencyAllowed Frequency UGB reduced UGB increased Figure 7-19. Silent step Gain vs. Frequency The loop transfer function has two poles and one zero -

  • One pole at origin
  • One pole (fP) due to the motor coil resistance and inductance - fP = RMOTOR / (2 * π * LMOTOR) (7)
  • One zero (fZ) created by the PI loop fZ = (KI * FPWM) / (2 * π * KP) (8) The proportional gain KP should be chosen to achieve the desired loop gain. Use the following equation to calculate the KP - KP = 10 * π * UGB * LMOTOR / VM (9) Where UGB is the unity-gain bandwidth of the loop, RMOTOR is the motor coil resistance, LMOTOR is the motor coil inductance, IFS is the full-scale current and VM is the supply voltage.
  • If any frequency is less than UGB, it is allowed to propagate.
  • Frequencies higher than UGB, such as PWM frequency or STEP frequency are attenuate and do not contribute to motor noise.
  • 200 Hz is a reasonable choice for UGB to attenuate most frequencies in the audible range.
  • In the event of supply voltage change, UGB can be changed by modifying the value of KP. This way similar audio noise suppression can be achieved across a wide range of operating conditions.
  • If the zero is chosen to be at a lower frequency than the motor pole, UGB will increase, as shown in Figure 7-18. The zero should be placed to cancel the motor pole. By equating f P and fZ for a discretized implementation, the following equation can be used to calculate KI. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

38 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

KI = KP * RMOTOR / (FPWM * LMOTOR) (10) As an example, consider the following use case -

  • VM = 24 V
  • IFS = 5 A
  • RMOTOR = 0.3 Ω
  • LMOTOR = 0.7 mH
  • UGB = 200 Hz
  • FPWM = 25 kHz
  • Above 50 RPM, the decay mode should change from silent step to smart tune ripple control. Using the previous equations, KP = 0.18326 and KI = 0.00314. The following register values can be set -
  • SS_KP = 0101111b = 47
  • SS_KI = 0000001b = 1
  • SS_KP_DIV_SEL = 011b = 1/256
  • SS_KI_DIV_SEL = 011b = 1/256
  • 50 RPM corresponds to roughly 42.6 kpps at 1/256 microstepping, so SS_THR = 00010101b = 21 Figure 7-20 shows the smooth sinusoidal coil current waveforms when the motor operates in silent step decay mode. Figure 7-20. Coil Current Waveform with Silent Step Decay Note For pre-production samples, writing 1b to EN_SS latches the part to operate with silent step decay mode, and transition between silent step and other decay modes happen when motor speed exceeds or drops below the SS_THR threshold. If EN_SS bit is toggled, a nSLEEP cycling is required. For production samples, EN_SS can be toggled to enable or disable silent step decay mode.

7.4.12 Auto-torque Dynamic Current Adjustment

For a typical stepper motor driver, the full-scale current is designed based on the peak load torque demand and ensures that the motor does not lose steps any time peak load is demanded. The current therefore is always constant irrespective of the load torque. As a result, when the load torque is lower than peak load, the driver and the motor dissipate some of the input power as resistive power loss, as represented in Figure 7-21. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 39 Product Folder Links: DRV8452

Op mal Current Output Current Time Motor CurrentLow High Figure 7-21. Power Loss with Conventional Stepper Driver In most systems, the demand for peak load torque occurs only rarely. For example, in an ATM machine, the stepper motors might be needed to deliver peak load for less than 15% of their overall run time. A typical stepper driver though ends up delivering full-scale current to the motors all the time - leading to lower system efficiency due to the unwanted power loss, larger system size and shorter lifetime of components. The auto-torque algorithm implemented in the DRV8452 improves system efficiency by dynamically changing the output current according to the load torque. Whenever the load torque is low, the output current is lower to reduce resistive losses; and when the load torque goes up, the output current increases immediately to prevent motor step loss. This concept is shown in Figure 7-22. As a result of improved efficiency due to auto-torque, the system runs at a lower temperature, which extends the lifetime of the components. Auto-torque can also enable the use of cheaper and smaller sized stepper motors. Power Saving Op mal Current Output Current Time Motor CurrentLow High Maximum Torque Figure 7-22. Power Saving with Auto-torque DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

40 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

The auto-torque feature is enabled by writing '1' to the ATQ_EN bit. To dynamically adapt the full-scale current, the auto-torque algorithm generates the ATQ_CNT parameter, which varies linearly with load torque. Figure 7-23 shows the block diagram of the closed-loop auto-torque algorithm - MOutput Power Stage DRV8452 Digital Core ATQ_CALC ATQ_LRN ATQ_CNT ATQ_UL ATQ_LL Hysteretic Comparator PID Controller (KP, KI, KD, ATQ_AVG, ATQ_FRZ) ATQ_TRQ_DAC ATQ_TRQ_DAC VREF Error Figure 7-23. Auto-torque Block Diagram Note When auto-torque is enabled, program ISTSL between ATQ_TRQ_MAX and ATQ_TRQ_MIN.

7.4.12.1 Auto-torque Learning Routine

For auto-torque algorithm to work, it is mandatory to estimate the ATQ_LRN parameter using the auto-torque learning routine. The ATQ_LRN parameter depends on the operating conditions and motor parameters, therefore re-learning is required everytime motor is changed or operating conditions are significantly changed. Table 7-21. Description of auto-torque learning parameters Parameter Description ATQ_LRN ATQ_LRN is the output of the auto-torque learning routine. It represents losses in the system at minimum load - such as I2R losses in the motor and the driver and friction in the motor. ATQ_LRN is proportional to the full-scale current setting of the driver. ATQ_LRN is represented by two parameters - ATQ_LRN_CONST1 and ATQ_LRN_CONST2. ATQ_LRN_MIN_CURRENT Represents the initial current level for auto torque learning routine. Initial current level = ATQ_LRN_MIN_CURRENT * 8 ATQ_LRN_STEP Represents the increase to initial current level for the learning routine. Final current level = ATQ_LRN_MIN_CURRENT + ATQ_LRN_STEP

  • 00b : ATQ_LRN_STEP = 128
  • 01b : ATQ_LRN_STEP = 16
  • 10b : ATQ_LRN_STEP = 32
  • 11b : ATQ_LRN_STEP = 64 Example : If ATQ_LRN_STEP = 10b and ATQ_LRN_MIN_CURRENT = 11000b, then Initial learn current level = 24*8 = 192 Final learn current level = 192 + 32 = 224 ATQ_LRN_CYCLE_SELECT Number of sine half cycles in one current level after which the learning routine lets the current jump to the next level.
  • 00b : 8 half-cycles
  • 01b : 16 half-cycles
  • 10b : 24 half-cycles
  • 11b : 32 half-cycles www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 41 Product Folder Links: DRV8452

Table 7-21. Description of auto-torque learning parameters (continued) LRN_START Writing '1' to this bit enables the auto torque learning process. After learning is completed, this bit automatically goes to '0'. LRN_DONE This bit becomes '1' after learning is complete. ATQ_LRN_CONST1 Indicates the ATQ_LRN parameter at the initial learning current level. ATQ_LRN_CONST2 Indicates the ATQ_LRN parameter at the final learning current level. Note ATQ_LRN_MIN_CURRENT and ATQ_LRN_STEP should be chosen such that the final current level does not exceed 255. The ATQ_LRN parameter has a linear relation with full-scale current. So, the learning routine needs to run at two different currents to deduce the values of the necessary parameters, as is shown in Figure 7-24. Once learning is enabled, the algorithm changes ATQ_TRQ_DAC automatically for few electrical cycles to extract the learning parameters. The learning finishes in less than 100 ms. ATQ_LRN Full-scale Current ATQ_LRN_CONST1 ATQ_LRN_CONST2 IFS1 IFS2 Figure 7-24. ATQ_LRN at two currents To enable automatic learning, following sequence of commands should be applied:

  • Write 1b to ATQ_EN
  • Run the motor with minimum load
  • Program ATQ_LRN_MIN_CURRENT.
  • Program ATQ_LRN_STEP.
  • Program ATQ_LRN_CYCLE_SELECT.
  • Write 1b to ATQ_LRN_START
  • The algorithm runs the motor with minimum current level for ATQ_LRN_CYCLE_SELECT number of half cycles
  • Next, the algorithm runs the motor with final current level for ATQ_LRN_CYCLE_SELECT number of half cycles
  • After learning is complete, – ATQ_LRN_START bit is auto cleared DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

42 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

– ATQ_LRN_DONE bit goes high

  • ATQ_LRN_CONST1 and ATQ_LRN_CONST2 are populated in their respective registers Once the ATQ_LRN_CONST1 and ATQ_LRN_CONST2 are known from the prototyping phase, they can be used in the mass production phase without invoking the learning routine. The following sequence of commands should be applied:
  • Program ATQ_LRN_MIN_CURRENT
  • Program ATQ_LRN_STEP
  • Program ATQ_LRN_CONST1
  • Program ATQ_LRN_CONST2
  • Enable ATQ Figure 7-25 shows the consolidated flowchart of the auto-torque learning routine. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 43 Product Folder Links: DRV8452

DRVOFF = 0 Spin Motor with desired DIR, STEP SPI WRITE Ini alize Con gura on Registers 4.5V /g1/g2VM /g1 65V MODE = 1 Wait tWAKE nSLEEP = 1 EN_OUT = 0 SPI WRITE ATQ_CTRL4 = Ini al Current ATQ_CTRL15 = Current step, No. of cycles ATQ_CTRL2, 3, 4, 5 = Learn parameter 1, 2 Run Motor with Min Load SPI WRITE ATQ_CTRL4 = Ini al Current ATQ_CTRL15 = Current step, No. of cycles ATQ_LRN_START = 1 SPI WRITE EN_OUT = 1 ATQ_EN = 1 ATQ_LRN_DONE = 1? ATQ_LRN_START = 0? No Use ATQ_LRN_CONST1, 2 for mass produc on No Yes Yes No Yes VM, Motor speed changed? Ini al Current + Step > 255? Figure 7-25. Auto-torque Learning Flowchart DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

44 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

The scopeshot below shows an automatic learning process with 740 mA initial current (I FS1) and 2.2 A final current (IFS2). The ATQ_LEARN_CYCLE_SELECT corresponds to 32 half-cycles. Traces from top to bottom: Load torque, coil current, supply current, nSCS Figure 7-26. Automatic learning Note The production samples will feature a VM_SCALE bit located in ATQ_CTRL17 bit 6. When enabled, this bit will automatically modify the auto-torque learning routine parameters in the event of a supply voltage change. In pre-production samples, this bit will be reserved.

7.4.12.2 ATQ_CNT and PID Control Loop

Figure 7-27 shows the ATQ_CALC parameter shown in the auto-torque block diagram. ATQ_CNTATQ_LRN ATQ_CALC Load Torque Peak Load Figure 7-27. ATQ_CALC Therefore, ATQ_CALC = ATQ_LRN + ATQ_CNT. As mentioned before, the ATQ_CNT parameter is proportional to load torque and inversely proportional to the full-scale current setting of the stepper driver. This relation is represented by Figure 7-28- www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 45 Product Folder Links: DRV8452

ATQ_CNT Load Torque AMAX AMIN TMIN TMAX IFS1 IFS2 ATQ_UL T1 T2 ATQ_LL IFS3 IFS4 IFS5 IFS1 < IFS2 < IFS3 < IFS4 < IFS5 Figure 7-28. ATQ_CNT change with load torque and full-scale current A high value of ATQ_CNT corresponding to a lower full-scale current is preferable, because that minimizes the unwanted resistive losses in the system and improves efficiency. The PID controller smoothens the response to load transients while minimizing the error. The PID algorithm is expressed as - u(t) = KP * e(t) + KI * ∫e(t)dt + KD * de(t)/dt (11) where, KP, KI and KD = PID loop constants u(t) = output of controller e(t) = error signal

  • In general, increasing the KP will increase the speed of the control system response. However, if KP is too large, the current waveform will begin to oscillate. If KP is increased further, the oscillations will become larger and the system will become unstable and may even oscillate out of control.
  • The KI term sums the error over time, so the effect is to drive the steady-state error to zero.
  • Increasing the KD parameter will cause the control system to react more strongly to changes in the error term and will increase the speed of the overall control system response. Most practical control systems use very small KD, because the derivative response is highly sensitive to noise. Table 7-22 describes the major parameters associated with the PID control loop - Table 7-22. Parameters for auto-torque PID control loop ATQ_CALC ATQ_CALC is an output of the auto-torque algorithm. It has two components - a no-load loss component (ATQ_LRN) and another component (ATQ_CNT) proportional to load torque. ATQ_CALC = ATQ_LRN + ATQ_CNT A simplistic plot of the ATQ_CALC prameter is shown in Figure 7-27. ATQ_CNT The component of auto-torque algorithm output that changes proportional to load torque. The ATQ_CNT parameter is also inversely proportional to the full-scale current setting of the stepper driver. ATQ_CNT ∝ Load torque; and ATQ_CNT ∝ 1 / Full-scale Current ATQ_CNT has a length of 12 bits. ATQ_UL Upper and lower boundaries of the hysteretic loop within which ATQ_CNT is controlled by modifying the ATQ_TRQ_DAC parameter. The CNT_OFLW flag indicates ATQ_CNT is more than ATQ_UL, and the CNT_UFLW indicates ATQ_CNT is less than ATQ_LL. ATQ_LL KP Proportional, integral and differential gain parameters for the PID control loop. KP has a length of 8 bits. KI and KD each have a length of 4 bits.KI KD DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

46 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Table 7-22. Parameters for auto-torque PID control loop (continued) ATQ_AVG The ATQ_CNT parameter is a moving average of ATQ_AVG number of half-cycles. Therefore, a high value for ATQ_AVG slows down the loop response time to a sudden peak load demand, but ensures smooth jerk-free transition to higher torque output. A low value causes the loop to respond immediately to a sudden load demand. 2 - 2 cycle average 4 - 4 cycle average 7 - 8 cycle average Other values : no averaging ATQ_FRZ Delay in electrical half-cycles after which current is changed in response to the PID loop. A small value increases the current quickly to meet peak load demand. This parameter has a range of 1 to 7. 1 - Fastest response time, but the loop can become unstable 7 - Slowest response, but the loop will be stable ATQ_TRQ_DAC Read-only. Auto-torque current level readout. Represents the full-scale current setting of the stepper driver when auto-torque is enabled. ATQ_TRQ_DAC can vary between user programmable ATQ_TRQ_MIN (minimum regulation current) and ATQ_TRQ_MAX (maximum regulation current) levels. ATQ_D_THR If error change is less then ATQ_D_THR, then KD does not contribute to correction. KD contributes only when error change is greater than ATQ_D_THR. For example: if ATQ_D_THR = 10,

  • If error change is 9, u(t) = KP * e(t) + KI * ∫e(t)dt
  • If error change is 12, then u(t) = KP * e(t) + KI * ∫e(t)dt + KD * de(t)/dt ATQ_MAX_INTEGRAL Indicates the saturation point of error integration. For example: if ATQ_MAX_INTEGRAL=10, error integration stops at 10 u(t) = KP * e(t) + KI * 10 + KD * de(t)/dt ATQ_ERROR_TRUNCATE Number of LSB bits truncated from error before used in PID loop equations. This option helps removing noise in current. The auto-torque algorithm maintains the ATQ_CNT value within the hysteretic band defined by ATQ_UL and ATQ_LL, by modulating the full-scale current.
  • If load demand suddenly increases, the ATQ_CNT goes above the ATQ_UL threshold, and the algorithm brings the ATQ_CNT within the band by increasing the full-scale current.
  • When load demand drops and ATQ_CNT goes below ATQ_LL, the algorithm reduces the full-scale current to bring the ATQ_CNT within the hysteretic band.
  • If the hysteretic band between ATQ_UL and ATQ_LL is moved up, efficiency and thermal performance improves due to lower full-scale current. But in the event of a sudden peak load, it takes longer to increase the current to its maximum value, leading to chances of step loss.
  • If the hysteretic band between ATQ_UL and ATQ_LL is moved down, efficiency improvement is only moderate due to the higher value of full-scale current, but step loss is no longer a concern.
  • If the gap between ATQ_UL and ATQ_LL is increased, it improves the immunity of the loop against system noise. Guidelines to tune the PID loop parameters are as follows -
  • Observe the ATQ_CNT during no load and desired current level
  • Write ATQ_UL and ATQ_LL such that ATQ_CNT is within those limits
  • The ATQ_UL should be chosen depending on the max pull-out torque of the motor, with some safety margin accounted for
  • Set KI and KD to zero first
  • Program a minimum KP value
  • Enable auto-torque and observe the current waveform at different loads
  • Increase KP to obtain the desired response time to load transients
  • Increase KI and ATQ_ERROR_TRUNCATE to stop any oscillation in the current waveform www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 47 Product Folder Links: DRV8452

The flowchart for selecting ATQ_UL, ATQ_LL, ATQ_TRQ_MAX and ATQ_TRQ_MIN parameters is shown below. START No Load motor with minimum load torque SPI WRITE ATQ_CTRL11 = ATQ_CTRL12 = Max Current ATQ_CTRL6, 7 = UL, LL = 0 ATQ_CTRL8 = KP = 1 Select Min and Max Current to high values Reduce Current (ATQ_CTRL11 = ATQ_CTRL12) Note Current as IFS1 Note ATQ_CNT as AMIN Load motor with maximum load torque Yes Yes No Note Current as IFS5 Note ATQ_CNT as AMAX Set ATQ_TRQ_MIN = IFS1 + Margin Set ATQ_TRQ_MAX = IFS5 + Margin Set UL and LL between AMIN and AMAX Increase Current (ATQ_CTRL11 = ATQ_CTRL12) Motor Stalled? Motor Stalled? Figure 7-29. Selecting ATQ_UL, ATQ_LL, ATQ_TRQ_MIN, ATQ_TRQ_MAX The following flowchart is for selecting KP, KI and KD parameters for tuning the auto-torque PID loop. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

48 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

The following figure shows the coil current waveform when load torque changes over 40 ms. KP = 1, KD = 5, ATQ_D_THR = 20, ATQ_ERROR_TRUNCATE = 2, current waveform in yellow trace. Figure 7-32. Current waveform with 40 ms Load Transient

7.4.12.3 Troubleshooting Tips

Observation : Current waveform is noisy

  • Increase ATQ_ERROR_TRUNCATE
  • Choose a wider band.i.e increase ATQ_UL,Reduce ATQ_LL
  • Increase ATQ_FRZ (upto 7)
  • Make ATQ_AVG = 4 or 8
  • Reduce KP
  • If KD is non-zero, use a higher ATQ_D_THR Observation : Current response is slow
  • Reduce ATQ_UL
  • Increase KP
  • Increase KD
  • Reduce ATQ_D_THR
  • Set ATQ_FRZ = 1
  • Set ATQ_AVG = 0 (Averaging disabled) Observation : Full-scale current in no load is relatively high
  • Increase ATQ_LL
  • Check CNT_UFLW status. If it is high and full-scale current in no load is still high, reduce ATQ_TRQ_MIN.

7.4.12.4 Efficiency Improvement with Auto-torque

The following images show the thermal performance improvements as a result of auto-torque. The thermal images are captured at the following condition: VM = 24 V, 1/16 microstep, 4A full-scale current, 3000 pps speed, No load, Room temperature ambient, Power on time = 10 minutes DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

50 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Table 7-23. Thermal performance improvement with Auto-torque DRV8452 Thermal Image: Auto-torque disabled DRV8452 Thermal Image: Auto-torque enabled Motor Thermal Image: Auto-torque disabled Motor Thermal Image: Auto-torque enabled

7.4.13 Standstill Power Saving Mode

When the controller is not sending any step pulses and the motor is holding the same position, the DRV8452 can be configured to operate in the standstill power saving mode. When this mode is enabled by writing '1' to the EN_STSL bit, the power dissipation of the system can be reduced by lowering the coil current from run current to holding current. After the last STEP pulse, the device waits for an amount of time programmed by the TSTSL_DLY register, after which the coil currents are ramped down from run current to holding current over a time period programmed by the TSTSL_FALL register. The STSL flag goes up to indicate that the device is in standstill power saving mode. Once the next STEP pulse is detected, the coil current immediately ramps up to run current. The run current is programmed by the TRQ_DAC register and the holding current is programmed by the ISTSL register, as shown in Figure 7-33. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 51 Product Folder Links: DRV8452

TRQ_DAC tSTSL_DLY tSTSL_FALL Figure 7-33. Standstill Power Saving Mode Note

  • TSTSL_FALL in production samples will be 1/16 th of their value in the pre-production samples. For example, TSTSL_FALL = 0001b will mean fall time for each current step will be 1 ms.
  • If ISTSL has to be changed while the device is in standstill power saving mode, first cycle the EN_STSL bit from 1b to 0b and back to 1b.

7.4.14 Charge Pump

A charge pump is integrated to supply the high-side N-channel MOSFET gate-drive voltage. The charge pump requires a capacitor between the VM and VCP pins to act as the storage capacitor. Additionally a ceramic capacitor is required between the CPH and CPL pins to act as the flying capacitor. VM VCP 1 μF VM CPH Charge Pump Control VM CPL 0.1 μF Figure 7-34. Charge Pump Block Diagram

7.4.15 Linear Voltage Regulator

A linear voltage regulator is integrated in the device. When the VCC pin is connected to DVDD, the DVDD regulator provides power to the low-side gate driver and all the internal circuits. For proper operation, bypass the DVDD pin to GND using a 1 μF ceramic capacitor. The DVDD output is nominally 5-V. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

52 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

1 μF DVDD 5 V VM Figure 7-35. Linear Voltage Regulator Block Diagram If a digital input must be tied permanently high, tying the input to the DVDD pin instead of an external regulator is preferred. This method saves power when the VM pin is not applied or in sleep mode: the DVDD regulator is disabled and current does not flow through the input pulldown resistors. For reference, logic level inputs have a typical pulldown of 200 kΩ. The nSLEEP pin cannot be tied to DVDD, else the device will never exit sleep mode.

7.4.16 VCC Voltage Supply

An external voltage can be applied to the VCC pin to power the internal logic circuitry. The voltage on the VCC pin should be between 3.05V and 5.5V and should be well regulated. When an external supply is not available, VCC must be connected to the DVDD pin of the device. When powered by the VCC, the internal logic blocks do not consume power from the VM supply rail - thereby reducing the power loss in the DRV8452. This is highly beneficial in high voltage applications, and when thermal conditions are critical. Bypass the VCC pin to ground using a 0.1 μF ceramic capacitor.

7.4.17 Logic Level, Tri-Level and Quad-Level Pin Diagrams

Figure 7-36 shows the input structure for M0, DECAY0, DECAY1 and ENABLE pins. Figure 7-36. Tri-Level Input Pin Diagram Figure 7-37 shows the input structure for M1 and TOFF pins. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 53 Product Folder Links: DRV8452

Figure 7-37. Quad-Level Input Pin Diagram Figure 7-38 shows the input structure for STEP, DIR, MODE, SDI, SCLK and nSLEEP pins. Figure 7-38. Logic-Level Input Pin Diagram The diagram below shows the input structure for the logic-level pin nSCS. Figure 7-39. nSCS Input Pin Diagram

7.4.18 Spread Spectrum

Spread spectrum or frequency dithering is used to reduce the effect of EMI by converting a narrowband signal into a wideband signal, which will spread the energy across multiple frequencies. Figure 7-40 illustrates how manipulating the clock frequency over time has the effect of spreading the energy. In the context of the DRV8452, the frequencies of the internal clock for digital circuits (10 MHz typical) and the clock for charge pump (357 kHz typical) are manipulated to reduce the peak energy and is distributed to other frequencies and their harmonics. This feature combined with output slew rate control minimizes the radiated emissions from the device and helps pass strict EMI standards. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

54 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Figure 7-40. EMI Reduction by Spread Spectrum, Frequency Modulation When the DRV8452 is configured with the SPI interface, spread spectrum can be enabled or disabled by the DIS_SSC bit. By default, spread spectrum is disabled after power-up. Writing '0' to the DIS_SSC bit enables spread spectrum. If the device is operating with silent step decay mode, spread spectrum is disabled. Additionally, when the DRV8452 is configured with the GPIO interface, spread spectrum is permanently disabled. There are many ways to implement spread spectrum. The DRV8452 uses the triangular analog modulation profile. Figure 7-41 and Figure 7-42 show the spread spectrum profiles of the internal digital clock and the charge pump clock around their respective centre frequencies. The digital clock varies by equal amounts over 14 steps between 9 MHz and 11 MHz. Note that the centre frequencies themselves will vary with process and temperature changes as shown in the electrical characteristics table, and the variations due to spread spectrum will be in addition to those. Spread spectrum ON

10 MHz Triangular Modulation

11 MHz

9 MHz

1.2 µs 1.2 µs x 14 = 16.8 µs 16.8 µs DIS_SSC 1b 0b Figure 7-41. Triangular Spread Spectrum of Internal Digital Clock Spread spectrum ON 357 kHz Spread spectrum OFF Charge Pump Frequency 416 kHz 312 kHz 2.8 µs 2.8 µs x 4 = 11.2 µs 11.2 µs DIS_SSC 1b 0b 333 kHz 384 kHz Triangular Modulation Figure 7-42. Triangular Spread Spectrum of Charge Pump Clock www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 55 Product Folder Links: DRV8452

7.4.19 Protection Circuits

The device is fully protected against supply undervoltage, charge pump undervoltage, output overcurrent, open load, and device overtemperature events. In addition, when operating with SPI interface, the device is protected against stall detection in the event of overload or end-of-line movement.

7.4.19.1 VM Undervoltage Lockout

If at any time the voltage on the VM pin falls below the UVLO falling threshold voltage:

  • All the outputs are disabled (High-Z)
  • The charge pump is disabled
  • nFAULT is driven low Normal operation resumes (motor driver and charge pump) when the VM voltage recovers above the UVLO rising threshold voltage. When operating with SPI interface, if the voltage on the VM pin falls below the UVLO falling threshold voltage, but is above the VRST or VCC UVLO (shown in Figure 7-43) :
  • SPI communication is available and the digital core of the device is active
  • The FAULT and UVLO bits are made high
  • The nFAULT pin is driven low From this condition, if the VM voltage recovers above the UVLO rising threshold voltage:
  • nFAULT pin is released (is pulled-up to the external voltage)
  • The FAULT bit is reset
  • The UVLO bit remains latched high until cleared through the CLR_FLT bit or an nSLEEP reset pulse. VRST UVLO reset or VCC UVLO VUVLO rising VUVLO falling Device Status SPI available Digital Alive Outputs switching CP enabled UVLO, FAULT bits ‘0’* nFAULT high Time VM Voltage * FAULT bit will be ‘0’ if no fault is present UVLO bit will be ‘1’ till cleared by CLR_FLT or nSLEEP pulse SPI available Digital Alive Outputs switching CP enabled UVLO bit ‘1’ FAULT bit ‘0’* nFAULT high SPI available Digital Alive Outputs Hi-Z CP disabled UVLO, FAULT bits ‘1’ nFAULT low Figure 7-43. Supply Voltage Ramp Profile When the voltage on the VM pin falls below the VRST or VCC UVLO (shown in Figure 7-44) :
  • SPI communication is unavailable and the digital core is shutdown
  • The FAULT and UVLO bits are low
  • The nFAULT pin is high During a subsequent power-up, when the VM voltage exceeds the VRST voltage:
  • The digital core comes alive
  • UVLO bit stays low
  • The FAULT bit is made high
  • The nFAULT pin is pulled low
  • When the VM voltage exceeds the VM UVLO rising threshold DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

56 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

– FAULT bit is reset – UVLO bit stays low – nFAULT pin is pulled high. VRST UVLO reset or VCC UVLO VUVLO rising VUVLO falling Device Status SPI available Digital Alive Outputs switching CP enabled UVLO, FAULT bits ‘0’* nFAULT high Time VM Voltage SPI available Digital Alive Outputs Hi-Z CP disabled UVLO, FAULT bits ‘1’ nFAULT low SPI unavailable Digital Reset Outputs Hi-Z CP disabled UVLO, FAULT bits ‘0’ nFAULT High SPI available Digital Alive Outputs Hi-Z CP disabled UVLO bit ‘0’ FAULT bit ‘1’ nFAULT low * FAULT bit will be ‘0’ if no fault is present SPI available Digital Alive Outputs switching CP enabled UVLO, FAULT bits ‘0’* nFAULT high Figure 7-44. Supply Voltage Ramp Profile

7.4.19.2 VCP Undervoltage Lockout (CPUV)

If at any time the voltage on the VCP pin falls below the CPUV voltage:

  • All the outputs are disabled (High-Z)
  • nFAULT pin is driven low
  • The charge pump remains active
  • For the SPI version, the FAULT and CPUV bits are made high. Normal operation resumes (motor-driver operation and nFAULT released) when the VCP undervoltage condition is removed. The CPUV bit remains set until it is cleared through the CLR_FLT bit or an nSLEEP reset pulse.

7.4.19.3 Logic Supply Power on Reset (POR)

If at any time the voltage on the VCC pin falls below the VCCUVLO threshold:

  • All the outputs are disabled (High-Z)
  • Charge pump is disabled. VCC UVLO is not reported on the nFAULT pin. Normal motor-driver operation resumes when the VCC undervoltage condition is removed. When device operates with SPI interface:
  • The NPOR bit is reset and latched low once VCC goes above the UVLO threshold.
  • NPOR remains in reset condition until cleared through the CLR_FLT bit or nSLEEP reset pulse.
  • After power up, NPOR is automatically latched high once the CLR_FLT command is issued. The VCC UVLO scenario is shown in Figure 7-45. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 57 Product Folder Links: DRV8452

4.5V 65V nSLEEP VCC UVLO H-BRIDGE, CHARGE PUMP , DIGITAL ENABLED DISABLED DVDD nFAULT NPOR CLR_FLT Figure 7-45. Logic Supply POR

7.4.19.4 Overcurrent Protection (OCP)

An analog current-limit circuit on any MOSFET limits the current through that MOSFET by removing the gate drive. If this current limit persists for longer than the tOCP time, an overcurrent fault is detected.

  • The MOSFETs in both H-bridges are disabled
  • nFAULT is driven low
  • Charge pump remains active.
  • When operating with SPI interface - – FAULT and OCP bits are latched high – For xOUTy to VM short, corresponding OCP_LSy_x bit goes high. – For xOUTy to ground short, corresponding OCP_HSxy_x bit goes high. – The TOCP bit programs the overcurrent protection deglitch time. The overcurrent protection can operate in two different modes: latched shutdown and automatic retry. The operating modes can be changed on the fly.

7.4.19.4.1 Latched Shutdown

To select latched shutdown mode:

  • For H/W interface, the ENABLE pin has to be Hi-Z
  • For SPI interface, the OCP_MODE bit should be '0' In this mode, once the OCP condition is removed, normal operation resumes after applying a CLR_FLT command, an nSLEEP reset pulse or a power cycling.

7.4.19.4.2 Automatic Retry

To select automatic retry mode:

  • For H/W interface, the ENABLE pin has to be HIGH (> 2.7 V)
  • For SPI interface, the OCP_MODE bit should be '1' In this mode, normal operation resumes automatically (motor-driver operation and nFAULT released) after the tRETRY time has elapsed and the fault condition is removed. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

58 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

7.4.19.5 Stall Detection

When operating with the SPI interface, the DRV8452 supports stall detection. Stepper motors have a distinct relation between the winding current, back-EMF, and mechanical torque load of the motor, as shown in Figure 7-46. For an unloaded motor, the back-EMF is 90° out-of-phase with the winding current. As motor load approaches the maximum torque capability of the motor for a given winding current, the back-EMF will move in phase with the winding current. By detecting back-EMF phase shift between rising and falling current quadrants of the motor current, the DRV8452 can detect a motor overload stall condition or an end-of-line travel. Figure 7-46. Stall Detection by Monitoring Motor Back-EMF The Stall Detection algorithm is enabled when -

  • The device is programmed to operate with the SPI interface (MODE = 1)
  • The decay mode is programmed as smart tune Ripple Control (DECAY = '111')
  • EN_STL is '1'
  • No fault condition exists (UVLO, OCP, OL, OTSD etc.). The algorithm compares the back-EMF between the rising and falling current quadrants by monitoring PWM off time and generates a parameter called torque count, represented by the 12-bit register TRQ_COUNT. The comparison is done in such a way that the TRQ_COUNT is largely independent of motor current, ambient temperature and supply voltage. Motor stall can be detected even if the driver is operating in full step mode. TRQ_COUNT is calculated as a running average from the most recent four electrical half-cycles. TRQ_COUNT register is updated once every electrical half-cycle. The updated TRQ_COUNT is compared with the STALL_TH, and if a stall condition is detected, stall fault will be reported and latched at the electrical half-cycle current zero crossing. For a lightly loaded motor, the TRQ_COUNT will be a non-zero value. As the motor approaches stall condition, TRQ_COUNT will approach zero and can be used to detect stall condition.
  • If anytime TRQ_COUNT falls below the stall threshold (represented by the 12-bit STALL_TH register), the device will detect a stall.
  • STALL, STL and FAULT bits are latched high in the SPI register.
  • The STL_REP bit controls how stall is reported. – If STL_REP is '1', the nFAULT pin will be driven low when a stall is detected. – If STEL_REP is '0', the nFAULT pin will stay high even if stall is detected. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 59 Product Folder Links: DRV8452

In the stalled condition, the motor shaft does not spin. The motor starts to spin again when the stall condition is removed and the motor ramps to its target speed. The nFAULT is released and the fault registers are cleared when a clear faults command is issued either via the CLR_FLT bit or an nSLEEP reset pulse. High motor coil resistance can result in low TRQ_COUNT. The TRQ_SCALE bit allows scaling up low TRQ_COUNT values, for ease of further processing.

  • If the initially calculated TRQ_COUNT value is less than 500 and the TRQ_SCALE bit is '1', then the TRQ_COUNT output in register is multiplied by a factor of 8.
  • If the TRQ_SCALE bit is '0', TRQ_COUNT retains the value originally calculated by the algorithm. Stall threshold can be set in two ways –
  • The user can write the STALL_TH bits by observing the behavior of the TRQ_COUNT output at all operating conditions.
  • The algorithm can learn the stall threshold using the automatic stall learning process, described below: – Before learning, ensure that the motor has reached its target speed. Do not learn stall threshold while the motor speed is ramping up or down. – Start learning by setting the STL_LRN bit to '1'. – Run motor with no load. – Wait for 32 electrical cycles for the driver to learn the steady-state count. – Stall the motor. – Wait for 16 electrical cycles for the driver to learn the stall count. – The STL_LRN_OK bit becomes '1' if learning is successful. – Stall threshold is calculated as the average of steady count and stall count and stored in the STALL_TH register. The following flowchart shows the ways to set stall threshold. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

60 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

DRVOFF = 0 Spin Motor with desired DIR, STEP nFAULT = 0? SPI READ Fault status YES NO DRVOFF = 0 Spin Motor with desired DIR, STEP STL = 1? NO Stop Motor SPI WRITE CTRL4 = 0xB0 YES, Motor Stalled nFAULT = 1? EN_OUT = 0 Inves gate Fault Condi on NO YES Clear Fault Stall Motor SPI READ DIAG Status 2 STL_LRN_OK = nFAULT = 0? SPI READ Fault status YES NO STL = 1? Other Faults take ac on NO Stop Motor SPI WRITE CTRL4 = 0xB0 YES, Motor Stalled nFAULT = 1? EN_OUT = 0 Inves gate Fault Condi on NO YES Clear Fault SPI WRITE Ini alize Registers 4.5V /g1/g2VM /g1 65V MODE = 1 Wait tWAKE nSLEEP = 1 EN_OUT = 0 SPI WRITE CTRL4 = 0x3C Set Desired VREF EN_OUT =1 Spin Motor with desired DIR, STEP Stall Motor for > 16 Electrical Cycles SPI READ DIAG Status 2 Stop Motor Remove Stall Clear Fault Spin Motor with desired DIR, STEP SPI READ Fault status SPI READ Fault status Stop Motor Clear Fault Stop Motor Clear Fault Other Faults, Take ac on SPI WRITE CTRL5, 6 = STALL_TH CTRL4 = 0x1C Set Desired VREF EN_OUT = 1 Spin Motor with desired DIR, STEP NO YES, Learn Success Re-learn Clear Fault SPI_READ CTRL7 and CTRL8 Registers to get TRQ_COUNT while spinning at the desired speed. Start with a STALL_TH of TRQ_COUNT/2 and ne tune for reliable Stall detec on. Figure 7-47. Stall learning flowchart www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 61 Product Folder Links: DRV8452

Sometimes the automatic stall learning process might not be successful due to an unstable torque count while the motor is running or stalled. For example, when the motor has high coil resistance or is running at very high or low speeds, the torque count might vary a lot over time and the difference between steady count and stall count might be small. In such cases, it is recommended not to use the automatic stall learning method. Instead, the user should carefully study the steady count and torque count across the range of operating conditions and set the threshold midway between the minimum steady count and the maximum stall count. A stall threshold learnt at one speed may not work well for another speed. It is recommended to re-learn the stall threshold every time the motor speed is changed considerably. Note

  • The stall detection algorithm depends on back-EMF modifying the PWM off time. The back-EMF is directly proportional to the speed of the motor. In order for stall detection to work reliably, minimum motor speed is required for generating back-EMF with sufficient amplitude. Higher motor coil resistance would require higher minimum speed for reliable stall detection.
  • If there is loss of current regulation due to low supply voltage, high coil resistance or high speed of the motor, stall detection may not work reliably, because the TRQ_COUNT can be erratic and may jump to a high value. This can be checked and confirmed by looking at the coil current waveform. If the coil current has a standard sinusoidal waveform, and the peak of the sinusoid reaches the desired full-scale current, then stall detection will work reliably. If the current waveform is triangular due to high speed or low supply voltage, stall detection algorithm might not work reliably.
  • If EN_STL = '1' and auto-torque is also enabled, coil current goes to ATQ_TRQ_MAX when motor stall is detected
  • If EN_STL = '0' and auto-torque is enabled, coil current goes to ATQ_TRQ_MIN when motor is stalled.

7.4.19.6 Open-Load Detection (OL)

Open-load fault is detected -

  • When the motor is running, if the winding current in any coil drops below the open-load current threshold (IOL)
  • When the motor is in a holding condition, if the winding current in any coil drops below the ITRIP level set by the indexer.
  • If this condition persists for more than the open-load detection time (tOL)
  • The EN_OL bit is '1' if the device is operating with SPI interface. The open-load detection time (tOL) is set as follows - Table 7-24. Open-load Detection Time MODE OL_T Maximum tOL (ms) 0 (H/W interface) NA 60 1 (SPI interface) 00 30 01 (default) 60 10 120 Once the open-load fault is detected -
  • nFAULT is pulled low.
  • If the device is operating with SPI interface - – OL and FAULT bits are latched high – If the OL_A bit is high, it indicates an open load fault in winding A, between AOUT1 and AOUT2. – An open load fault between BOUT1 and BOUT2 causes the OL_B bit to go high. When the open-load condition is removed, the behavior depends on whether the device is configured with H/W interface or SPI interface. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

62 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

When the device is configured with H/W interface and open-load condition is removed:

  • If the ENABLE pin is logic HIGH, nFAULT is released immediately.
  • If the ENABLE pin is Hi-Z, nFAULT is released after a nSLEEP reset pulse has been applied. When the device is configured with SPI interface and open-load condition is removed:
  • If the OL_MODE bit is '1', nFAULT is released immediately.
  • If the OL_MODE bit is '0', nFAULT is released after a clear faults command is issued either via the CLR_FLT bit or an nSLEEP reset pulse. The open-load fault also clears when the device is power cycled or comes out of sleep mode. Note
  • The open-load fault detection is not supported in the silent step decay mode. Write '0' to EN_OL if EN_SS is '1'.
  • If ENABLE pin is changed from logic HIGH to Hi-Z on-the-fly, apply a nSLEEP reset pulse.
  • If OL_MODE is changed from '1' to '0' or EN_OL is changed from '1' to '0', apply a clear faults command.
  • When the device is operating with auto-torque enabled, if open-load fault is detected, the coil current goes to a value corresponding to TRQ_DAC.

7.4.19.7 Overtemperature Warning (OTW)

  • If the device is operating with SPI interface (MODE = 1)
  • If the die temperature exceeds the trip point of the overtemperature warning (TOTW) When the OTW is detected -
  • OTW and TF bits are set.
  • The device performs no additional action and continues to function.
  • The charge pump remains active.
  • If the TW_REP bit is '1' - – nFAULT is pulled low in the event of OTW – FAULT bit is set When the die temperature falls below the hysteresis point (T HYS_OTW) of the overtemperature warning, the OTW and TF bits clear automatically.

7.4.19.8 Thermal Shutdown (OTSD)

Thermal shutdown is detected if the die temperature exceeds the thermal shutdown limit (T OTSD). When thermal shutdown is detected -

  • All MOSFETs in the H-bridges are disabled
  • nFAULT is driven low
  • Charge pump is disabled
  • For operation with SPI interface – FAULT, TF and OTS bits are set high The recovery from thermal shutdown protection can be in two different modes: latched shutdown and automatic retry. The recovery modes can be changed on the fly.

7.4.19.8.1 Latched Shutdown

To select latched shutdown mode,

  • If device is operating with H/W interface, the ENABLE pin should be Hi-Z
  • If device is operating with SPI interface, OTSD_MODE should be '0' www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 63 Product Folder Links: DRV8452

In this mode, after the junction temperature falls below the overtemperature threshold limit minus the hysteresis (TOTSD – THYS_OTSD), normal operation resumes after applying an nSLEEP reset pulse or a power cycling.

7.4.19.8.2 Automatic Retry

To select automatic retry mode,

  • For H/W interface, the ENABLE pin has to be logic HIGH (>2.7V)
  • For SPI interface, OTSD_MODE bit should be '1' In this mode, normal operation resumes (motor-driver operation and the nFAULT line released) when the junction temperature falls below the overtemperature threshold limit minus the hysteresis (T OTSD – T HYS_OTSD). When operating with SPI interface, the TF and OTS bits remain latched high indicating that a thermal event occurred until a clear faults command is issued either via the CLR_FLT bit or an nSLEEP reset pulse. 7.4.19.9 nFAULT Output The nFAULT pin has an open-drain output and should be pulled up to a 5-V, 3.3-V or 1.8-V supply. nFAULT pin will be high after power-up. When a fault is detected, the nFAULT pin will be logic low. For a 5-V pullup, the nFAULT pin can be tied to the DVDD pin with a resistor. For a 3.3-V or 1.8-V pullup, an external supply must be used. Output nFAULT Figure 7-48. nFAULT Pin

7.4.19.10 Fault Condition Summary

Table 7-25. Fault Condition Summary FAULT CONDITION CONFIGURATION ERROR REPORT BRIDGE CHARGE PUMP INDEXER LOGIC RECOVERY VM undervoltage (UVLO) VM < VUVLO — nFAULT / SPI Disabled Disabled Disabled Reset VM > VUVLO VCP undervoltage (CPUV) VCP < VCPUV — nFAULT / SPI Disabled Operating Operating Operating VCP > VCPUV Logic Supply POR VCC < VCCUVLO — SPI Disabled Disabled Disbaled Reset VCC > VCCUVLO Overcurrent (OCP) IOUT > IOCP OCP_MODE = 0b / ENABLE = Hi-Z nFAULT / SPI Disabled Operating Operating Operating Latched: CLR_FLT / nSLEEP OCP_MODE = 1b / ENABLE = 1 nFAULT / SPI Disabled Operating Operating Operating Automatic retry: tRETRY Open Load (OL) No load detected Default (H/W) / EN_OL = 1b (SPI) nFAULT / SPI Operating Operating Operating Operating Report only Stall Detection (STALL) Stall / stuck motor STL_REP = 0b SPI Operating Operating Operating Operating CLR_FLT / nSLEEPSTL_REP = 1b nFAULT / SPI Operating Operating Operating Operating Overtemperature Warning (OTW) TJ > TOTW TW_REP = 1b nFAULT / SPI Operating Operating Operating Operating Automatic: TJ < TOTW - THYS_OTW TW_REP = 0b SPI Operating Operating Operating Operating DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

64 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Table 7-25. Fault Condition Summary (continued) FAULT CONDITION CONFIGURATION ERROR REPORT BRIDGE CHARGE PUMP INDEXER LOGIC RECOVERY Thermal Shutdown (OTSD) TJ > TOTSD OTSD_MODE = 0b / ENABLE = Hi-Z nFAULT / SPI Disabled Disabled Operating Operating Latched: CLR_FLT / nSLEEP OTSD_MODE = 1b / ENABLE = 1 nFAULT/ SPI Disabled Disabled Operating Operating Automatic: TJ < TOTSD - THYS_OTSD Note For pre-production samples, if the device is configured to operate with H/W interface, and the M0 pin is Hi-z at power-up, then the nFAULT pin will stay low even if there are no faults. To release the nFAULT, the user has to apply an nSLEEP reset pulse. This behavior will not be present in the production samples - nFAULT will be pulled-high after power- up if there are no faults.

7.4.20 Device Functional Modes

7.4.20.1 Sleep Mode

When the nSLEEP pin is low, the device enters a low-power sleep mode. In sleep mode, all the internal MOSFETs, the DVDD regulator, SPI and the charge pump is disabled. The tSLEEP time must elapse after a falling edge on the nSLEEP pin before the device enters sleep mode. The device is brought out of sleep automatically if the nSLEEP pin is brought high. The tWAKE time must elapse before the device is ready for inputs.

7.4.20.2 Disable Mode

The ENABLE pin is used to enable or disable the half bridges in the device. When the ENABLE pin is low, the output drivers are disabled (Hi-Z). For operation with SPI interface, the EN_OUT bit can also be used to disable the output drivers. When the EN_OUT bit is '0', the output drivers are disabled (Hi-Z). Table 7-26. Conditions to Enable or Disable Output Drivers nSLEEP ENABLE EN_OUT H-BRIDGE

0 Don't Care Don't Care Disabled

7.4.20.3 Operating Mode

This mode is enabled when -

  • nSLEEP is high
  • ENABLE pin is Hi-Z or 1
  • EN_OUT = '1' for SPI interface
  • VM > UVLO The tWAKE time must elapse before the device is ready for inputs. 7.4.20.4 nSLEEP Reset Pulse A latched fault can be cleared by an nSLEEP reset pulse. This pulse width must be greater than 20 µs and smaller than 40 µs. If nSLEEP is low for longer than 40 µs, but less than 120 µs, the faults are cleared and the www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 65 Product Folder Links: DRV8452

device may or may not shutdown, as shown in the timing diagram below. This reset pulse does not affect the status of the charge pump or other functional blocks. nSLEEP All faults cleared, device stays active All faults cleared, device may or may not shutdown Device shuts down (goes into sleep mode, faults cleared by default) 20 µs 40 µs 120 µs Figure 7-49. nSLEEP Reset Pulse Note For the pre-production samples, when the device is configured to operate with H/W interface, nFAULT will be pulled-low after device wakes up. An nSLEEP reset pulse has to be applied to release the nFAULT output. This behavior will not be present in production samples.

7.4.20.5 Functional Modes Summary

Table 7-27. Functional Modes Summary CONDITION CONFIGURATION H-BRIDGE DVDD Regulator CHARGE PUMP INDEXER Logic Sleep mode 4.5 V < VM <

48 V nSLEEP pin = 0 Disabled Disbaled Disabled Disabled Disabled

Operating 4.5 V < VM < 48 V nSLEEP pin = 1 ENABLE = 1 and EN_OUT = '1' Operating Operating Operating Operating Operating Disabled 4.5 V < VM < 48 V nSLEEP pin = 1 ENABLE pin = 0 or EN_OUT = '0' Disabled Operating Operating Operating Operating

7.5 Programming

7.5.1 Serial Peripheral Interface (SPI) Communication

When configured to operate with SPI interface, the device has full duplex, 4-wire synchronous communication that is used to set device configurations, operating parameters, and read out diagnostic information from the device. This section describes the SPI protocol, the command structure, and the control and status registers. The SPI operates in target mode and can be connected with a controller in the following configurations:

  • One target device
  • Multiple target devices in parallel connection
  • Multiple target devices in series (daisy chain) connection

7.5.1.1 SPI Format

The serial data input (SDI) word consists of a 16-bit word, with an 8 bit-command (A1), followed by 8-bit data (D1). The serial data output (SDO) word consists of 8 bits of status register with fault status indication (S1), followed by a report byte (R1). Figure 7-50 shows the data sequence between the controller and the SPI target driver. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

66 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Figure 7-50. SPI Format - Standard "16-bit" Frame A valid frame must meet the following conditions:

  • The SCLK pin must be low when the nSCS pin goes low and when the nSCS pin goes high.
  • The nSCS pin should be taken high for at least 500 ns between frames.
  • When the nSCS pin is asserted high, any signals at the SCLK and SDI pins are ignored, and the SDO pin is in the high-impedance state (Hi-Z).
  • A full 16 SCLK cycles must occur for a valid transaction for a standard frame, or alternately, for a daisy chainframe with "n" number of peripheral devices, 16 + (n x 16) SCLK cycles must occur for a valid transaction. Else, a frame error (SPI_ERROR) is reported and the data is ignored if it is a WRITE operation.
  • Data on SDO from the device is propagated on the rising edge of SCLK, while data on SDI is captured by thedevice on the subsequent falling edge of SCLK.
  • The most-significant bit (MSB) is shifted in and out first.
  • For a write command, the existing data in the register being written to is shifted out on the SDO pin following the 8-bit command data. The SDI input data word is 16 bits long and consists of the following format:
  • Command byte (first 8 bits) – MSB bit indicates frame type (bit B15 = 0 for standard frame). – Next to MSB bit, W0, indicates read or write operation (bit B14, write = 0, read = 1) – Followed by 6 address bits, A[5:0] (bits B13 through B8)
  • Data byte (last 8 bits) – Last 8 bits indicate data, D[7:0] (bits B7 through B0). For a read operation, these bits are typically set to null values, while for a write operation, these bits have the data value for the addressed register. Table 7-28. SDI - Standard Frame Format R/W ADDRESS DATA B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0

0 W0 A5 A4 A3 A2 A1 A0 D7 D6 D5 D4 D3 D2 D1 D0

The SDO output data word is 16 bits long and consists of the following format:

  • Status byte (first 8 bits) – 2 MSB bits are forced high (B15, B14 = 1). – Following 6 bits are from the FAULT register (bits B13 through B8)
  • Report byte (last 8 bits) – The last 8 bits (B7:B0) are either the data currently in the register being read for a read operation (W0 =1), or, existing data in the register being written to for a write command (W0 = 0). Table 7-29. SDO Output Data Word Format STATUS REPORT B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1 B0 1 1 UVLO CPUV OCP STL TF OL D7 D6 D5 D4 D3 D2 D1 D0 www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 67 Product Folder Links: DRV8452

7.5.1.2 SPI for Multiple Target Devices in Daisy Chain Configuration

Multiple devices can be connected to the controller with and without the daisy chain. For connecting a 'n' number of devices to a controller without using a daisy chain, 'n' number of GPIO resources from controller have to be utilized for nSCS pins. Whereas, if the daisy chain configuration is used, a single nSCS line can be used for connecting multiple devices. Figure 7-51 shows the topology when three devices are connected in daisy chain. This configuration saves GPIO ports when multiple devices are communicating to the same controller. Commander DRV8452 (1) DRV8452 (2) DRV8452 (3)SDI1 SDO1 / SDI2 SDO2 / SDI3 SDO3M-SDO M-nSCS M-SCLK M-SDI Figure 7-51. Three Devices Connected in Daisy Chain The first device in the chain receives data from the MCU in the following format for 3-device configuration: 2 bytes of header (HDRx) followed by 3 bytes of address (Ax) followed by 3 bytes of data (Dx). HDR1 HDR2 A3 A2 A1 D3 D2 D1 SDI1 nSCS S3 S2 S1 HDR1 HDR2 R3 R2 R1 SDO3 S1 HDR1 HDR2 A3 A2 R1 D3 D2 SDO1 / SDI2 S2 S1 HDR1 HDR2 A3 R2 R1 D3 SDO2 / SDI3 All Address bytes reach destination All Data bytes reach destination Reads executed here Writes executed hereStatus response here Figure 7-52. SPI Frame With Three Devices After the data has been transmitted through the chain, the MCU receives the data string in the following format for 3-device configuration: 3 bytes of status (Sx) followed by 2 bytes of header followed by 3 bytes of report (Rx). HDR1 HDR2 A3 A2 A1 D3 D2 D1 SDI nSCS S3 S2 S1 HDR1 HDR2 R3 R2 R1 SDO Figure 7-53. SPI Data Sequence for Three Devices DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

68 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

The header bytes contain information of the number of devices connected in the chain, and a global clear fault command that will clear the fault registers of all the devices on the rising edge of the chip select (nSCS) signal. Header values N5 through N0 are 6 bits dedicated to show the number of devices in the chain. Up to 63 devices can be connected in series for each daisy chain connection. The 5 LSBs of the HDR2 register are don’t care bits that can be used by the MCU to determine integrity of the daisy chain connection. Header bytes must start with 1 and 0 for the two MSBs. HDR 1 HDR 2 1 0 N5 N4 N3 N2 N1 N0 1 0 CLR x x x x x No. of devices in the chain (up to 26 ± 1= 63) 1 = global FAULT clear 0 = GRQ¶WFDUH 'RQ¶WFDUH Figure 7-54. Header Bytes The status byte provides information about the fault status register for each device in the daisy chain so that the MCU does not have to initiate a read command to read the fault status from any particular device. This keeps additional read commands for the MCU and makes the system more efficient to determine fault conditions flagged in a device. Status bytes must start with 1 and 1 for the two MSBs. Header Bytes (HDRx) Status Byte (Sx) 1 0 N5 N4 N3 N2 N1 N0 Data Byte (Dx) Address Byte (Ax) 1 0 CLR X X X X X 1 1 UVLO CPUV OCP STL TF OL D7 D6 D5 D4 D3 D2 D1 D0

0 R/W A5 A4 A3 A2 A1 A0

Figure 7-55. Contents of Header, Status, Address, and Data Bytes When data passes through a device, it determines the position of itself in the chain by counting the number of status bytes it receives followed by the first header byte. For example, in this 3-device configuration, device 2 in the chain receives two status bytes before receiving the HDR1 byte which is then followed by the HDR2 byte. From the two status bytes, the data can determine that its position is second in the chain. From the HDR2 byte, the data can determine how many devices are connected in the chain. In this way, the data only loads the relevant address and data byte in its buffer and bypasses the other bits. This protocol allows for faster communication without adding latency to the system for up to 63 devices in the chain. The address and data bytes remain the same with respect to a 1-device connection. The report bytes (R1 through R3) are the content of the register being accessed. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 69 Product Folder Links: DRV8452

Figure 7-56. SPI Transaction

7.5.1.3 SPI for Multiple Target Devices in Parallel Configuration

Figure 7-57 shows three DRV8452 devices connected in parallel configuration. Microcontroller DRV8452 (3)DRV8452 (2)DRV8452 (1) SPI SPI SPI M-CS1 M-CS2 M-CS3 M-CLK M-SDO M-SDI nSCS SCLK nSCS SCLK nSCS SCLK SDI1 SDO1 SDI2 SDO2 SDI3 SDO3 Figure 7-57. Three Devices Connected in Parallel Configuration

7.6 Register Maps

Table 7-30 lists the memory-mapped registers for the device. All register addresses not listed in Table 7-30 should be considered as reserved locations and the register contents must not be modified. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

70 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Table 7-30. Memory Map Register 7 6 5 4 3 2 1 0 Type Address FAULT FAULT SPI_ERROR UVLO CPUV OCP STL TF OL R 0x00 DIAG1 OCP_LS2_B OCP_HS2_B OCP_LS1_B OCP_HS1_B OCP_LS2_A OCP_HS2_A OCP_LS1_A OCP_HS1_A R 0x01 DIAG2 STSL OTW OTS STL_LRN_OK STALL LRN_DONE OL_B OL_A R 0x02 DIAG3 RSVD NHOME CNT_OFLW CNT_UFLW RSVD NPOR RSVD R 0x03 CTRL1 EN_OUT SR RSVD TOFF [1:0] DECAY [2:0] RW 0x04 CTRL2 DIR STEP SPI_DIR SPI_STEP MICROSTEP_MODE [3:0] RW 0x05 CTRL3 CLR_FLT LOCK [2:0] TOCP OCP_MODE OTSD_MODE OTW_REP RW 0x06 CTRL4 TBLANK_TIME[1:0] STL_LRN EN_STL STL_REP STL_FRQ STEP_FRQ_TOL[1:0] RW 0x07 CTRL5 STALL_TH [7:0] RW 0x08 CTRL6 RC_RIPPLE[1:0] DIS_SSC TRQ_SCALE STALL_TH[11:8] RW 0x09 CTRL7 TRQ_COUNT [7:0] R 0x0A CTRL8 RSVD TRQ_COUNT[11:8] R 0x0B CTRL9 EN_OL OL_MODE OL_T[1:0] STEP_EDGE RES_AUTO[1:0] EN_AUTO RW 0x0C CTRL10 ISTSL[7:0] RW 0x0D CTRL11 TRQ_DAC[7:0] RW 0x0E CTRL12 EN_STSL TSTSL_FALL[3:0] RSVD RW 0x0F CTRL13 TSTSL_DLY[5:0] RSVD RW 0x10 INDEX1 CUR_A_POS[7:0] R 0x11 INDEX2 CUR_A_SIGN RSVD R 0x12 INDEX3 CUR_B_POS[7:0] R 0x13 INDEX4 CUR_B_SIGN RSVD INDEX_POS[9:8] R 0x14 INDEX5 INDEX_POS[7:0] R 0x15 CUSTOM_CTRL1 RSVD EN_CUSTOM RW 0x16 CUSTOM_CTRL2 CUSTOM_CURRENT1[7:0] RW 0x17 CUSTOM_CTRL3 CUSTOM_CURRENT2[7:0] RW 0x18 CUSTOM_CTRL4 CUSTOM_CURRENT3[7:0] RW 0x19 CUSTOM_CTRL5 CUSTOM_CURRENT4[7:0] RW 0x1A CUSTOM_CTRL6 CUSTOM_CURRENT5[7:0] RW 0x1B CUSTOM_CTRL7 CUSTOM_CURRENT6[7:0] RW 0x1C CUSTOM_CTRL8 CUSTOM_CURRENT7[7:0] RW 0x1D CUSTOM_CTRL9 CUSTOM_CURRENT8[7:0] RW 0x1E ATQ_CTRL1 ATQ_CNT[7:0] R 0x1F ATQ_CTRL2 ATQ_CNT[10:8] RSVD ATQ_LRN_CONST1[10:8] RW 0x20 ATQ_CTRL3 ATQ_LRN_CONST1[7:0] RW 0x21 ATQ_CTRL4 ATQ_LRN_MIN_CURRENT[4:0] ATQ_LRN_CONST2[10:8] RW 0x22 ATQ_CTRL5 ATQ_LRN_CONST2[7:0] RW 0x23 ATQ_CTRL6 ATQ_UL[7:0] RW 0x24 ATQ_CTRL7 ATQ_LL[7:0] RW 0x25 ATQ_CTRL8 KP[7:0] RW 0x26 ATQ_CTRL9 KI[3:0] KD[3:0] RW 0x27 ATQ_CTRL10 ATQ_EN LRN_START ATQ_FRZ[2:0] ATQ_AVG[2:0] RW 0x28 www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 71 Product Folder Links: DRV8452

Table 7-30. Memory Map (continued) Register 7 6 5 4 3 2 1 0 Type Address ATQ_CTRL11 ATQ_TRQ_MIN[7:0] RW 0x29 ATQ_CTRL12 ATQ_TRQ_MAX[7:0] RW 0x2A ATQ_CTRL13 ATQ_D_THR[7:0] RW 0x2B ATQ_CTRL14 ATQ_MAX_INTEGRAL[7:0] RW 0x2C ATQ_CTRL15 ATQ_ERROR_TRUNCATE[3:0] ATQ_LRN_STEP[1:0] ATQ_LRN_CYCLE_SELECT[1:0] RW 0x2D ATQ_CTRL16 ATQ_TRQ_DAC[7:0] R 0x2E ATQ_CTRL17 RSVD RW 0x2F ATQ_CTRL18 RSVD VREF_INT_EN RSVD RW 0x30 SS_CTRL1 RSVD SS_PWM_FREQ[1:0] RSVD EN_SS RW 0x31 SS_CTRL2 RSVD SS_KP[6:0] RW 0x32 SS_CTRL3 RSVD SS_KI[6:0] RW 0x33 SS_CTRL4 RSVD SS_KI_DIV_SEL[2:0] RSVD SS_KP_DIV_SEL[2:0] RW 0x34 SS_CTRL5 SS_THR[7:0] RW 0x35 CTRL14 RSVD RW 0x3C Complex bit access types are encoded to fit into small table cells. Table 7-31 shows the codes that are used for access types in this section. Table 7-31. Access Type Codes Access Type Code Description Read Type R R Read Write Type W W Write Reset or Default Value -n Value after reset or the default value Note

  • The VREF_INT_EN bit is located in ATQ_CTRL18 register bit 5 in pre-production samples. For production samples, the VREF_INT_EN bit will be located in CTRL13 register bit 1.
  • The production samples will feature an INDEX_RESET bit located in CTRL1 register bit 5. This bit will reset the indexer to 45° electrical angle, but the contents of the registers will not change.
  • The production samples will feature a VM_SCALE bit located in ATQ_CTRL17 bit 6. When enabled, this bit will modify the auto-torque learning routine parameters in the event of a supply voltage change. In pre-production samples, this bit will be reserved.
  • The production samples will feature VM_ADC bits located in the CTRL14 register. These bits will output the value of the supply voltage. For the pre-production samples, the CTRL14 will be reserved.

7.6.1 Status Registers

The status registers are used to reporting warning and fault conditions. Status registers are read-only registers. Table 7-32 lists the memory-mapped registers for the status registers. All register offset addresses not listed in Table 7-32 should be considered as reserved locations and the register contents should not be modified. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

72 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Table 7-32. Status Registers Summary Table Address Register Name Section 0x00 FAULT Go 0x01 DIAG1 Go 0x02 DIAG2 Go 0x03 DIAG3 Go

7.6.1.1 FAULT (address = 0x00) [Default = 00h]

FAULT status is shown in Figure 7-58 and described in Table 7-33. Read-only Return to the Register Maps Table Figure 7-58. FAULT Register 7 6 5 4 3 2 1 0 FAULT SPI_ERROR UVLO CPUV OCP STL TF OL R-0b R-0b R-0b R-0b R-0b R-0b R-0b R-0b Table 7-33. FAULT Register Field Descriptions Bit Field Type Default Description 7 FAULT R 0b FAULT bit is '1' when device has any fault condition. During normal operation, FAULT bit is '0'. nFAULT pin is pulled down when FAULT bit is '1'. nFAULT pin is released during normal operation.

6 SPI_ERROR R 0b Indicates SPI protocol errors, such as more SCLK pulses than are required

or SCLK is absent even though nSCS is low. SPI_ERROR becomes '1' in fault and the nFAULT pin is driven low. Normal operation resumes when the protocol error is removed and a clear faults command has been issued either through the CLR_FLT bit or an nSLEEP reset pulse.

5 UVLO R 0b When this bit is '1', it indicates an supply undervoltage lockout fault

condition. 4 CPUV R 0b When this bit is '1', it indicates charge pump undervoltage fault condition.

3 OCP R 0b When this bit is '1', it indicates overcurrent fault condition

2 STL R 0b When this bit is '1', it indicates motor stall condition.

1 TF R 0b Logic OR of the overtemperature warning (OTW) and overtemperature

shutdown (OTSD). When this bit is '1', it indicates overtemperature fault. 0 OL R 0b When this bit is '1', it indicates open-load condition.

7.6.1.2 DIAG1 (address = 0x01) [Default = 00h]

DIAG1 is shown in Figure 7-59 and described in Table 7-34. Read-only Return to the Register Maps Table Figure 7-59. DIAG1 Register 7 6 5 4 3 2 1 0 R-0b R-0b R-0b R-0b R-0b R-0b R-0b R-0b www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 73 Product Folder Links: DRV8452

Table 7-34. DIAG1 Register Field Descriptions Bit Field Type Default Description

7 OCP_LS2_B R 0b When this bit is '1', it indicates overcurrent fault on the low-side FET of half

6 OCP_HS2_B R 0b When this bit is '1', it indicates overcurrent fault on the high-side FET of half

5 OCP_LS1_B R 0b When this bit is '1', it indicates overcurrent fault on the low-side FET of half

4 OCP_HS1_B R 0b When this bit is '1', it indicates overcurrent fault on the high-side FET of half

3 OCP_LS2_A R 0b When this bit is '1', it indicates overcurrent fault on the low-side FET of half

2 OCP_HS2_A R 0b When this bit is '1', it indicates overcurrent fault on the high-side FET of half

1 OCP_LS1_A R 0b When this bit is '1', it indicates overcurrent fault on the low-side FET of half

0 OCP_HS1_A R 0b When this bit is '1', it indicates overcurrent fault on the high-side FET of half

7.6.1.3 DIAG2 (address = 0x02) [Default = 00h]

DIAG2 is shown in Figure 7-60 and described in Table 7-35. Read-only Return to the Register Maps Table Figure 7-60. DIAG2 Register 7 6 5 4 3 2 1 0 STSL OTW OTS STL_LRN_OK STALL LRN_DONE OL_B OL_A R-0b R-0b R-0b R-0b R-0b R-0b R-0b R-0b Table 7-35. DIAG2 Register Field Descriptions Bit Field Type Default Description

7 STSL R 0b When this bit is '1', it indicates that the device is operating with

standstill power saving mode. 6 OTW R 0b When this bit is '1', it indicates overtemperature warning. 5 OTS R 0b When this bit is '1', it indicates overtemperature shutdown.

4 STL_LRN_OK R 0b When this bit is '1', it indicates stall detection learning is

successful. 3 STALL R 0b When this bit is '1', it indicates motor stall condition.

2 LRN_DONE R 0b When this bit is '1', it indicates auto torque learning is

successful.

1 OL_B R 0b When this bit is '1', it indicates open-load detection on BOUT

coil.

0 OL_A R 0b When this bit is '1', it indicates open-load detection on AOUT

coil.

7.6.1.4 DIAG3 (address = 0x03) [Default = 00h]

DIAG3 is shown in Figure 7-61 and described in Table 7-36. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

74 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Return to the Register Maps Table Figure 7-61. DIAG3 Register 7 6 5 4 3 2 1 0 RSVD NHOME CNT_OFLW CNT_UFLW RSVD NPOR RSVD R-0b R-0b R-0b R-0b R-0b R-0b R-00b Table 7-36. DIAG3 Register Field Descriptions Bit Field Type Default Description

7 RSVD R 0b Reserved

6 NHOME R 0b When this bit is '1', it indicates indexer is at a position other than

home position.

5 CNT_OFLW R 0b When this bit is '1', it indicates ATQ_CNT is more than ATQ_UL

4 CNT_UFLW R 0b When this bit is '1', it indicates ATQ_CNT is less than ATQ_LL

3 RSVD R 0b Reserved

2 NPOR R 0b 0b = Indicates a prior VCC UVLO event

1b = Indicates that the NPOR bit has been cleared by a CLR_FLT or nSLEEP reset pulse input after a VCC UVLO event 1-0 RSVD R 00b Reserved

7.6.2 Control Registers

The IC control registers are used to configure the device. Control registers are read and write capable. Table 7-37 lists the memory-mapped registers for the control registers. All register offset addresses not listed in Table 7-37 should be considered as reserved locations and the register contents should not be modified. Table 7-37. Control Registers Summary Table Address Register Name Section 0x04 CTRL1 Go 0x05 CTRL2 Go 0x06 CTRL3 Go 0x07 CTRL4 Go 0x08 CTRL5 Go 0x09 CTRL6 Go 0x0A CTRL7 Go 0x0B CTRL8 Go 0x0C CTRL9 Go 0x0D CTRL10 Go 0x0E CTRL11 Go 0x0F CTRL12 Go 0x1A CTRL13 Go 0x3C CTRL14 Go

7.6.2.1 CTRL1 (address = 0x04) [Default = 0Fh]

CTRL1 is shown in Figure 7-62 and described in Table 7-38. Read/Write www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 75 Product Folder Links: DRV8452

Return to the Register Maps Table Figure 7-62. CTRL1 Control Register 7 6 5 4 3 2 1 0 EN_OUT SR RSVD TOFF [1:0] DECAY [2:0] R/W-0b R/W-0b R/W-0b R/W-01b R/W-111b Table 7-38. CTRL1 Control Register Field Descriptions Bit Field Type Default Description

7 EN_OUT R/W 0b 0b = All outputs are disabled

1b = All outputs are enabled

6 SR R/W 0b 0b = Output rise/fall time 100 ns

1b = Output rise/fall time 50 ns 5 RSVD R/W 0b Reserved. 4-3 TOFF [1:0] R/W 01b 00b = 7 µs 01b = 16 µs 10b = 24 µs 11b = 32 µs 2-0 DECAY [2:0] R/W 111b 000b = Reserved 001b = SLOW - MIXED 30% decay 010b = SLOW - MIXED 60% decay 011b = SLOW - FAST decay 100b = MIXED 30% - MIXED 30% decay 101b = Reserved 110b = Smart tune Dynamic Decay 111b = Smart tune Ripple Control Note The production samples will feature an INDEX_RESET bit located in CTRL1 register bit 5. This bit will reset the indexer to 45° electrical angle, but the contents of the registers will not change. For pre-production samples, the CTRL1 bit 5 will be reserved.

7.6.2.2 CTRL2 (address = 0x05) [Default = 06h]

CTRL2 is shown in Figure 7-63 and described in Table 7-39. Read/Write Return to the Register Maps Table Figure 7-63. CTRL2 Control Register 7 6 5 4 3 2 1 0 DIR STEP SPI_DIR SPI_STEP MICROSTEP_MODE [3:0] R/W-0b R/W-0b R/W-0b R/W-0b R/W-0110b Table 7-39. CTRL2 Control Register Field Descriptions Bit Field Type Default Description 7 DIR R/W 0b Direction input. When SPI_DIR = 1, if DIR = 1, motor moves in the forward direction; and when DIR = 0, motor moves in the reverse direction. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

76 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Table 7-39. CTRL2 Control Register Field Descriptions (continued) Bit Field Type Default Description 6 STEP R/W 0b Step input. Logic '1' causes the indexer to advance one step, when SPI_STEP = 1. This bit is self-clearing, automatically becomes '0' after writing '1'.

5 SPI_DIR R/W 0b 0b = Outputs follow input DIR pin for direction of stepping

1b = Outputs follow DIR bit in SPI register for direction of stepping

4 SPI_STEP R/W 0b 0b = Outputs follow input STEP pin for stepping

1b = Outputs follow STEP bit in SPI register for stepping 3-0 MICROSTEP_MODE [3:0] R/W 0110b 0000b = Full step (2-phase excitation) with 100% current 0001b = Full step (2-phase excitation) with 71% current 0010b = Non-circular 1/2 step 0011b = 1/2 step 0100b = 1/4 step 0101b = 1/8 step 0110b = 1/16 step 0111b = 1/32 step 1000b = 1/64 step 1001b = 1/128 step 1010b = 1/256 step 1011b to 1111b = Reserved

7.6.2.3 CTRL3 (address = 0x06) [Default = 38h]

CTRL3 is shown in Figure 7-64 and described in Table 7-40. Read/Write Return to the Register Maps Table Figure 7-64. CTRL3 Control Register 7 6 5 4 3 2 1 0 CLR_FLT LOCK [2:0] TOCP OCP_MODE OTSD_MODE OTW_REP R/W-0b R/W-011b R/W-1b R/W-0b R/W-0b R/W-0b Table 7-40. CTRL3 Control Register Field Descriptions Bit Field Type Default Description 7 CLR_FLT R/W 0b Write '1' to this bit to clear all latched fault bits. This bit automatically resets to '0' after '1' is written. 6-4 LOCK [2:0] R/W 011b Write 110b to lock the settings by ignoring further register writes except to these bits and address 0x06h bit 7 (CLR_FLT). Writing any sequence other than 110b has no effect when unlocked. Write 011b to this register to unlock all registers. Writing any sequence other than 011b has no effect when locked.

3 TOCP R/W 1b 1b = Overcurrent protection deglitch time is 2 μs

0b = Overcurrent protection deglitch time is 1 μs

2 OCP_MODE R/W 0b 0b = Overcurrent condition causes a latched fault

1b = Overcurrent condition fault recovery is auto-retry

1 OTSD_MODE R/W 0b 0b = Overtemperature condition causes a latched fault

1b = Overtemperature condition fault recovery is auto-retry www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 77 Product Folder Links: DRV8452

Table 7-40. CTRL3 Control Register Field Descriptions (continued) Bit Field Type Default Description

0 TW_REP R/W 0b 0b = Overtemperature or undertemperature warning is not reported on

1b = Overtemperature or undertemperature warning is reported on nFAULT

7.6.2.4 CTRL4 (address = 0x07) [Default = 49h]

CTRL4 control is shown in Figure 7-65 and described in Table 7-41. Read/Write Return to the Register Maps Table Figure 7-65. CTRL4 Control Register 7 6 5 4 3 2 1 0 TBLANK_TIME[1:0] STL_LRN EN_STL STL_REP FRQ_CHG STEP_FREQ_TOL[1:0] R/W-01b R/W-0b R/W-0b R/W-1b R/W-0b R/W-00b Table 7-41. CTRL4 Control Register Field Descriptions Bit Field Type Default Description 7-6 TBLANK_TIME[1:0] R/W 01b Controls the current sense blanking time. 00b = 1.5 μs blanking time 01b = 2 μs blanking time 10b = 2.5 μs blanking time 11b = 3 μs blanking time 5 STL_LRN R/W 0b Write '1' to enable automatic learning of stall detection threshold. This bit automatically returns to '0' when the stall learning process is complete.

4 EN_STL R/W 0b 0b = Stall detection is disabled

1b = Stall detection is enabled

3 STL_REP R/W 1b 0b = Stall detection is not reported on nFAULT

1b = Stall detection is reported on nFAULT

2 FRQ_CHG R/W 0b 0b = STEP input is filtered as per the STEP_FRQ_TOL bits

1b = STEP input is not filtered 1-0 STEP_FRQ_TOL[1: R/W 01b Programs the filter setting for the STEP input. 00b = 1% filtering 01b = 2% filtering 10b = 4% filtering 11b = 6% filtering

7.6.2.5 CTRL5 (address = 0x08) [Default = 03h]

CTRL5 is shown in Figure 7-66 and described in Table 7-42. Read/Write Return to the Register Maps Table Figure 7-66. CTRL5 Control Register 7 6 5 4 3 2 1 0 STALL_TH [7:0] R/W-00000011b DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

78 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Table 7-42. CTRL5 Control Register Field Descriptions Bit Field Type Default Description 7-0 STALL_TH [7:0] R/W 00000011b Lower 8-bits of stall threshold. 000000000000b = 0 count 000000000011b = 3 counts XXXXXXXXXXXXb = 1 to 4094 counts 111111111111b = 4095 counts

7.6.2.6 CTRL6 (address = 0x09) [Default = 20h]

CTRL6 is shown in Figure 7-67 and described in Table 7-43. Read/Write Return to the Register Maps Table Figure 7-67. CTRL6 Control Register 7 6 5 4 3 2 1 0 RC_RIPPLE[1:0] DIS_SSC TRQ_SCALE STALL_TH[11:8] R/W-00b R/W-1b R/W-0b R/W-0000b Table 7-43. CTRL6 Control Register Field Descriptions Bit Field Type Default Description 7-6 RC_RIPPLE[1:0] R/W 00b Controls the current ripple in smart tune ripple control decay mode. 00b = 1% ripple 01b = 2% ripple 10b = 4% ripple 11b = 6% ripple

5 DIS_SSC R/W 1b 0b = spread-spectrum enabled

1b = spread-spectrum disabled

4 TRQ_SCALE R/W 0b 0b = No torque count scaling is applied

1b = Torque count is scaled up by a factor of 8 3-0 STALL_TH[11:8] R/W 0000b 4 MSB bits of stall threshold.

7.6.2.7 CTRL7 (address = 0x0A) [Default = FFh]

CTRL7 is shown in Figure 7-68 and described in Table 7-44. Read-only Return to the Register Maps Table Figure 7-68. CTRL7 Control Register 7 6 5 4 3 2 1 0 TRQ_COUNT[7:0] R-11111111b Table 7-44. CTRL7 Control Register Field Descriptions Bit Field Type Default Description 7-0 TRQ_COUNT[7:0] R 11111111b 8 LSB bits of TRQ_COUNT. 000000000000b = 0 count XXXXXXXXXXXXb = 1 to 4094 counts 111111111111b = 4095 counts www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 79 Product Folder Links: DRV8452

7.6.2.8 CTRL8 (address = 0x0B) [Default = 0Fh]

CTRL8 is shown in Figure 7-69 and described in Table 7-45. Read-only Return to the Register Maps Table Figure 7-69. CTRL8 Control Register 7 6 5 4 3 2 1 0 RSVD TRQ_COUNT[11:8] R-0000b R-1111b Table 7-45. CTRL8 Control Register Field Descriptions Bit Field Type Default Description 7-4 RSVD R 0000b Reserved. 3-0 TRQ_COUNT[11:8] R 1111b 4 MSB bits of TRQ_COUNT.

7.6.2.9 CTRL9 (address = 0x0C) [Default = 10h]

CTRL9 is shown in Figure 7-70 and described in Table 7-46. Read/Write Return to the Register Maps Table Figure 7-70. CTRL9 Control Register 7 6 5 4 3 2 1 0 EN_OL OL_MODE OL_T[1:0] STEP_EDGE RES_AUTO[1:0] EN_AUTO R/W-0b R/W-0b R/W-01b R/W-0b R/W-00b R/W-0b Table 7-46. CTRL9 Control Register Field Descriptions Bit Field Type Default Description 7 EN_OL R/W 0b Write '1' to enable open load detection. When this bit is '0', open load detection is disabled.

6 OL_MODE R/W 0b 0b = nFAULT is released after latched OL fault is cleared

using CLR_FLT bit or nSLEEP reset pulse 1b = nFAULT is released immediately after OL fault condition is removed 5-4 OL_T[1:0] R/W 01b Controls the open load fault detection time. 00b = 30 ms (max) 01b = 60 ms (max) 10b = 120 ms (max) 11b = Reserved

3 STEP_EDGE R/W 0b 0b = Active edge for STEP input is only rising edge

1b = Active edge for STEP input is both rising and falling edges 2-1 RES_AUTO[1:0] R/W 00b Controls the microstepping resolution in automatic microstepping mode. 00b = 1/256 01b = 1/128 10b = 1/64 11b = 1/32

0 EN_AUTO R/W 0b 0b = Automatic microstepping disabled

1b = Automatic microstepping enabled DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

80 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

7.6.2.10 CTRL10 (address = 0x0D) [Default = 80h]

CTRL10 control is shown in Figure 7-71 and described in Table 7-47. Read/Write Return to the Register Maps Table Figure 7-71. CTRL10 Control Register 7 6 5 4 3 2 1 0 ISTSL[7:0] R/W-10000000b Table 7-47. CTRL10 Control Register Field Descriptions Bit Field Type Default Description 7-0 ISTSL[7:0] R/W 10000000b Determines the holding current. 11111111b = 256/256 x 100% 11111110b = 255/256 x 100% 11111101b = 254/256 x 100% 11111100b = 253/256 x 100% 00000000b = 1/256 x 100%

7.6.2.11 CTRL11 (address = 0x0E) [Default = FFh]

CTRL11 control is shown in Figure 7-72 and described in Table 7-48. Read/Write Return to the Register Maps Table Figure 7-72. CTRL11 Control Register 7 6 5 4 3 2 1 0 TRQ_DAC[7:0] R/W-11111111b Table 7-48. CTRL11 Control Register Field Descriptions Bit Field Type Default Description 7-0 TRQ_DAC[7:0] R/W 11111111b Determines the run current. 11111111b = 256/256 x 100% 11111110b = 255/256 x 100% 11111101b = 254/256 x 100% 11111100b = 253/256 x 100% 00000000b = 1/256 x 100%

7.6.2.12 CTRL12 (address = 0x0F) [Default = 20h]

CTRL12 is shown in Figure 7-73 and described in Table 7-49. Read/Write Return to the Register Maps Table Figure 7-73. CTRL12 Control Register 7 6 5 4 3 2 1 0 EN_STSL TSTSL_FALL[3:0] RSVD www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 81 Product Folder Links: DRV8452

Figure 7-73. CTRL12 Control Register (continued) R/W-0b R/W-0100b R/W-000b Table 7-49. CTRL12 Control Register Field Descriptions Bit Field Type Default Description

7 EN_STSL R/W 0b 0b = Standstill power saving mode disabled

1b = Standstill power saving mode enabled 6-3 TSTSL_FALL[3:0] R/W 0100b Controls the time it takes the current to reduce from TRQ_DAC to ISTSL after TSTSL_DLY time has elapsed 0000b: fall time = 0 0001b: fall time for each current step = 16 ms 0100b: fall time for each current step = 64 ms 1111b: fall time for each current step = 240 ms 2-0 RSVD R/W 000b Reserved Note TSTSL_FALL in production samples will be 1/16 th of their value in the pre-production samples. For example, TSTSL_FALL = 0001b will mean fall time for each current step will be 1 ms.

7.6.2.13 CTRL13 (address = 0x10) [Default = 10h]

CTRL13 is shown in Figure 7-74 and described in Table 7-50. Read/Write Return to the Register Maps Table Figure 7-74. CTRL13 Control Register 7 6 5 4 3 2 1 0 TSTSL_DLY[5:0] RSVD R/W-000100b R/W-00b Table 7-50. CTRL13 Control Register Field Descriptions Bit Field Type Default Description 7-2 TSTSL_DLY[5:0] R/W 000100b Controls the delay between last STEP pulse and activation of standstill power saving mode. 000000b: Reserved 000001b: Delay = 1 x 16 ms = 16 ms 000100b: Delay = 4 x 16 ms = 64 ms 111111b: Delay = 63 x 16 ms = 1.008 s 1-0 RSVD R/W 00b Reserved Note

  • Do not set TSTSL_DLY to 000000b.
  • The VREF_INT_EN bit is located in ATQ_CTRL18 register bit 5 in pre-production samples. For production samples, the VREF_INT_EN bit will be located in CTRL13 register bit 1. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

82 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

7.6.3 Indexer Registers

The indexer registers provide signed current values for coils A and B, and the position in the microstep table for the current in coil A. Indexer registers are read only. Table 7-51 lists the memory-mapped registers for the indexer registers. All register offset addresses not listed in Table 7-51 should be considered as reserved locations and the register contents should not be modified. Table 7-51. Indexer Registers Summary Table Address Register Name Section 0x11 INDEX1 Go 0x12 INDEX2 Go 0x13 INDEX3 Go 0x14 INDEX4 Go 0x15 INDEX5 Go

7.6.3.1 INDEX1 (address = 0x11) [Default = 80h]

INDEX1 is shown in Figure 7-75 and described in Table 7-52. Read only Return to the Register Maps Table Figure 7-75. INDEX1 Register 7 6 5 4 3 2 1 0 CUR_A[7:0] R-10000000b Table 7-52. INDEX1 Register Field Descriptions Bit Field Type Default Description 7-0 CUR_A[7:0] R 10000000b Indicates the current of motor coil A for the position indicated by the INDEX_POS bits.

7.6.3.2 INDEX2 (address = 0x12) [Default = 80h]

INDEX2 is shown in Figure 7-76 and described in Table 7-53. Read only Return to the Register Maps Table Figure 7-76. INDEX2 Register 7 6 5 4 3 2 1 0 CUR_A_SIGN RSVD R-1b R-0000000b Table 7-53. INDEX2 Register Field Descriptions Bit Field Type Default Description

7 CUR_A_SIGN R 1b Outputs the sign of coil A current for the position indicated by

the INDEX_POS bits. 1b = Coil A current is positive 0b = Coil A current is negative 6-0 RSVD R 0000000b Reserved www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 83 Product Folder Links: DRV8452

7.6.3.3 INDEX3 (address = 0x13) [Default = 80h]

INDEX3 is shown in Figure 7-77 and described in Table 7-54. Read only Return to the Register Maps Table Figure 7-77. INDEX3 Register 7 6 5 4 3 2 1 0 CUR_B[7:0] R-10000000b Table 7-54. INDEX3 Register Field Descriptions Bit Field Type Default Description 7-0 CUR_B[7:0] R 10000000b Indicates the current of motor coil B for the position indicated by the INDEX_POS bits.

7.6.3.4 INDEX4 (address = 0x14) [Default = 80h]

INDEX4 is shown in Figure 7-78 and described in Table 7-55. Read only Return to the Register Maps Table Figure 7-78. INDEX4 Register 7 6 5 4 3 2 1 0 CUR_B_SIGN RSVD INDEX_POS[9:8] R-1b R-00000b R-00b Table 7-55. INDEX4 Register Field Descriptions Bit Field Type Default Description

7 CUR_B_SIGN R 1b Outputs the sign of coil B current for the position indicated by

the INDEX_POS bits. 1b = Coil B current is positive 0b = Coil B current is negative 6-2 RSVD R 00000b Reserved 1-0 INDEX_POS[9:8] R 00b Upper two MSBs of the indexer position

7.6.3.5 INDEX5 (address = 0x15) [Default = 80h]

INDEX5 is shown in Figure 7-79 and described in Table 7-56. Read only Return to the Register Maps Table Figure 7-79. INDEX5 Register 7 6 5 4 3 2 1 0 INDEX_POS[7:0] R-10000000b DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

84 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Table 7-56. INDEX5 Register Field Descriptions Bit Field Type Default Description 7-0 INDEX_POS[7:0] R 10000000b Outputs the lower 8 bits of the indexer position Note In production samples, the INDEX_POS bits will output the actual coil A current -> sin (90° x CUR_A / 255).

7.6.4 Custom Microstepping Registers

The custom microstep registers store the current values corresponding to the first quadrant of coil A current. Custom microstep registers are read and write capable. Table 7-57 lists the memory-mapped registers for the custom microstep registers. All register offset addresses not listed in Table 7-57 should be considered as reserved locations and the register contents should not be modified. Table 7-57. Custom microstep Registers Summary Table Address Register Name Section 0x16 CUSTOM_CTRL1 Go 0x17 CUSTOM_CTRL2 Go 0x18 CUSTOM_CTRL3 Go 0x19 CUSTOM_CTRL4 Go 0x1A CUSTOM_CTRL5 Go 0x1B CUSTOM_CTRL6 Go 0x1C CUSTOM_CTRL7 Go 0x1D CUSTOM_CTRL8 Go 0x1E CUSTOM_CTRL9 Go

7.6.4.1 CUSTOM_CTRL1 (address = 0x16) [Default = 00h]

CUSTOM_CTRL1 is shown in Figure 7-80 and described in Table 7-58. Read/Write Return to the Register Maps Table Figure 7-80. CUSTOM_CTRL1 Register 7 6 5 4 3 2 1 0 RSVD EN_CUSTOM R/W-0000000b R/W-0b Table 7-58. CUSTOM_CTRL1 Register Field Descriptions Bit Field Type Default Description 7-1 RSVD R/W 0000000b Reserved

0 EN_CUSTOM R/W 0b 0b = Custom microstepping table is disabled

1b = Custom microstepping table is enabled

7.6.4.2 CUSTOM_CTRL2 (address = 0x17) [Default = 00h]

CUSTOM_CTRL2 is shown in Figure 7-81 and described in Table 7-59. Read/Write www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 85 Product Folder Links: DRV8452

Return to the Register Maps Table Figure 7-81. CUSTOM_CTRL2 Register 7 6 5 4 3 2 1 0 CUSTOM_CURRENT1[7:0] R/W-00000000b Table 7-59. CUSTOM_CTRL2 Register Field Descriptions Bit Field Type Default Description 7-0 CUSTOM_CURRENT1[7:0] R/W 00000000b Current value for position 1 in first quadrant

7.6.4.3 CUSTOM_CTRL3 (address = 0x18) [Default = 00h]

CUSTOM_CTRL3 is shown in Figure 7-82 and described in Table 7-60. Read/Write Return to the Register Maps Table Figure 7-82. CUSTOM_CTRL3 Register 7 6 5 4 3 2 1 0 CUSTOM_CURRENT2[7:0] R/W-00000000b Table 7-60. CUSTOM_CTRL3 Register Field Descriptions Bit Field Type Default Description 7-0 CUSTOM_CURRENT2[7:0] R/W 00000000b Current value for position 2 in first quadrant

7.6.4.4 CUSTOM_CTRL4 (address = 0x19) [Default = 00h]

CUSTOM_CTRL4 is shown in Figure 7-83 and described in Table 7-61. Read/Write Return to the Register Maps Table Figure 7-83. CUSTOM_CTRL4 Register 7 6 5 4 3 2 1 0 CUSTOM_CURRENT3[7:0] R/W-00000000b Table 7-61. CUSTOM_CTRL4 Register Field Descriptions Bit Field Type Default Description 7-0 CUSTOM_CURRENT3[7:0] R/W 00000000b Current value for position 3 in first quadrant

7.6.4.5 CUSTOM_CTRL5 (address = 0x1A) [Default = 00h]

CUSTOM_CTRL5 is shown in Figure 7-84 and described in Table 7-62. Read/Write Return to the Register Maps Table Figure 7-84. CUSTOM_CTRL5 Register 7 6 5 4 3 2 1 0 CUSTOM_CURRENT4[7:0] R/W-00000000b DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

86 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Table 7-62. CUSTOM_CTRL5 Register Field Descriptions Bit Field Type Default Description 7-0 CUSTOM_CURRENT4[7:0] R/W 00000000b Current value for position 4 in first quadrant

7.6.4.6 CUSTOM_CTRL6 (address = 0x1B) [Default = 00h]

CUSTOM_CTRL6 is shown in Figure 7-85 and described in Table 7-63. Read/Write Return to the Register Maps Table Figure 7-85. CUSTOM_CTRL6 Register 7 6 5 4 3 2 1 0 CUSTOM_CURRENT5[7:0] R/W-00000000b Table 7-63. CUSTOM_CTRL6 Register Field Descriptions Bit Field Type Default Description 7-0 CUSTOM_CURRENT5[7:0] R/W 00000000b Current value for position 5 in first quadrant

7.6.4.7 CUSTOM_CTRL7 (address = 0x1C) [Default = 00h]

CUSTOM_CTRL7 is shown in Figure 7-86 and described in Table 7-64. Read/Write Return to the Register Maps Table Figure 7-86. CUSTOM_CTRL7 Register 7 6 5 4 3 2 1 0 CUSTOM_CURRENT6[7:0] R/W-00000000b Table 7-64. CUSTOM_CTRL7 Register Field Descriptions Bit Field Type Default Description 7-0 CUSTOM_CURRENT6[7:0] R/W 00000000b Current value for position 6 in first quadrant

7.6.4.8 CUSTOM_CTRL8 (address = 0x1D) [Default = 00h]

CUSTOM_CTRL8 is shown in Figure 7-87 and described in Table 7-65. Read/Write Return to the Register Maps Table Figure 7-87. CUSTOM_CTRL8 Register 7 6 5 4 3 2 1 0 CUSTOM_CURRENT7[7:0] R/W-00000000b Table 7-65. CUSTOM_CTRL8 Register Field Descriptions Bit Field Type Default Description 7-0 CUSTOM_CURRENT7[7:0] R/W 00000000b Current value for position 7 in first quadrant www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 87 Product Folder Links: DRV8452

7.6.4.9 CUSTOM_CTRL9 (address = 0x1E) [Default = 00h]

CUSTOM_CTRL9 is shown in Figure 7-88 and described in Table 7-66. Read/Write Return to the Register Maps Table Figure 7-88. CUSTOM_CTRL9 Register 7 6 5 4 3 2 1 0 CUSTOM_CURRENT8[7:0] R/W-00000000b Table 7-66. CUSTOM_CTRL9 Register Field Descriptions Bit Field Type Default Description 7-0 CUSTOM_CURRENT8[7:0] R/W 00000000b Current value for position 8 in first quadrant

7.6.5 Auto torque Registers

The auto torque registers control the auto torque feature. Auto torque registers are read and write capable. Table 7-67 lists the memory-mapped registers for the auto torque registers. All register offset addresses not listed in Table 7-67 should be considered as reserved locations and the register contents should not be modified. Table 7-67. Auto torque Registers Summary Table Address Register Name Section 0x1F ATQ_CTRL1 Go 0x20 ATQ_CTRL2 Go 0x21 ATQ_CTRL3 Go 0x22 ATQ_CTRL4 Go 0x23 ATQ_CTRL5 Go 0x24 ATQ_CTRL6 Go 0x25 ATQ_CTRL7 Go 0x26 ATQ_CTRL8 Go 0x27 ATQ_CTRL9 Go 0x28 ATQ_CTRL10 Go 0x29 ATQ_CTRL11 Go 0x2A ATQ_CTRL12 Go 0x2B ATQ_CTRL13 Go 0x2C ATQ_CTRL14 Go 0x2D ATQ_CTRL15 Go 0x2E ATQ_CTRL16 Go 0x2F ATQ_CTRL17 Go 0x30 ATQ_CTRL18 Go

7.6.5.1 ATQ_CTRL1 (address = 0x1F) [Default = 00h]

ATQ_CTRL1 is shown in Figure 7-89 and described in Table 7-68. Read ONLY Return to the Register Maps Table DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

88 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Figure 7-89. ATQ_CTRL1 Register 7 6 5 4 3 2 1 0 ATQ_CNT[7:0] R-00000000b Table 7-68. ATQ_CTRL1 Register Field Descriptions Bit Field Type Default Description 7-0 ATQ_CNT[7:0] R 00000000b Read-only. Indicates the 8 LSB bits of the ATQ_CNT output. ATQ_CNT is proportional to the mechanical load torque.

7.6.5.2 ATQ_CTRL2 (address = 0x20) [Default = 00h]

ATQ_CTRL2 is shown in Figure 7-90 and described in Table 7-69. Read/Write Return to the Register Maps Table Figure 7-90. ATQ_CTRL2 Register 7 6 5 4 3 2 1 0 ATQ_CNT[10:8] RSVD ATQ_LRN_CONST1[10:8] R/W-000b R/W-00b R/W-000b Table 7-69. ATQ_CTRL2 Register Field Descriptions Bit Field Type Default Description 7-5 ATQ_CNT[10:8] R/W 000b Indicates the 3 MSB bits of the ATQ_CNT output 4-3 RSVD R/W 00b Reserved 2-0 ATQ_LRN_CONST1[10:8] R/W 000b Indicates the 3 MSB bits of the ATQ_LRN parameter at the initial learning current level.

7.6.5.3 ATQ_CTRL3 (address = 0x21) [Default = 00h]

ATQ_CTRL3 is shown in Figure 7-91 and described in Table 7-70. Read/Write Return to the Register Maps Table Figure 7-91. ATQ_CTRL3 Register 7 6 5 4 3 2 1 0 ATQ_LRN_CONST1[7:0] R/W-00000000b Table 7-70. ATQ_CTRL3 Register Field Descriptions Bit Field Type Default Description 7-0 ATQ_LRN_CONST1[7:0] R/W 00000000b 8 LSB bits of the ATQ_LRN parameter at the initial learning current level.

7.6.5.4 ATQ_CTRL4 (address = 0x22) [Default = 20h]

ATQ_CTRL4 is shown in Figure 7-92 and described in Table 7-71. Read/Write Return to the Register Maps Table www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 89 Product Folder Links: DRV8452

Figure 7-92. ATQ_CTRL4 Register 7 6 5 4 3 2 1 0 ATQ_LRN_MIN_CURRENT[4:0] ATQ_LRN_CONST2[10:8] R/W-00100b R/W-000b Table 7-71. ATQ_CTRL4 Register Field Descriptions Bit Field Type Default Description 7-3 ATQ_LRN_MIN_CURRENT[4:0] R/W 00100b Represents the initial current level for auto torque learning. Initial learning current = ATQ_LRN_MIN_CURRENT * 8 2-0 ATQ_LRN_CONST2[10:8] R/W 000b 3 MSB bits of the ATQ_LRN parameter at the final learning current level.

7.6.5.5 ATQ_CTRL5 (address = 0x23) [Default = 00h]

ATQ_CTRL5 is shown in Figure 7-93 and described in Table 7-72. Read/Write Return to the Register Maps Table Figure 7-93. ATQ_CTRL5 Register 7 6 5 4 3 2 1 0 ATQ_LRN_CONST2[7:0] R/W-00000000b Table 7-72. ATQ_CTRL5 Register Field Descriptions Bit Field Type Default Description 7-0 ATQ_LRN_CONST2[7:0] R/W 00000000b 8 LSB bits of the ATQ_LRN parameter at the final learning current level.

7.6.5.6 ATQ_CTRL6 (address = 0x24) [Default = 00h]

ATQ_CTRL6 is shown in Figure 7-94 and described in Table 7-73. Read/Write Return to the Register Maps Table Figure 7-94. ATQ_CTRL6 Register 7 6 5 4 3 2 1 0 ATQ_UL[7:0] R/W-00000000b Table 7-73. ATQ_CTRL6 Register Field Descriptions Bit Field Type Default Description 7-0 ATQ_UL[7:0] R/W 00000000b Programs the upper limit of the auto torque hysterestic band. Upper band of desired operating region of ATQ_CNT.

7.6.5.7 ATQ_CTRL7 (address = 0x25) [Default = 00h]

ATQ_CTRL7 is shown in Figure 7-95 and described in Table 7-74. Read/Write Return to the Register Maps Table DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

90 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Figure 7-95. ATQ_CTRL7 Register 7 6 5 4 3 2 1 0 ATQ_LL[7:0] R/W-00000000b Table 7-74. ATQ_CTRL7 Register Field Descriptions Bit Field Type Default Description 7-0 ATQ_LL[7:0] R/W 00000000b Programs the lower limit of the auto torque hysterestic band. Lower Band of desired operating region of ATQ_CNT.

7.6.5.8 ATQ_CTRL8 (address = 0x26) [Default = 00h]

ATQ_CTRL8 is shown in Figure 7-96 and described in Table 7-75. Read/Write Return to the Register Maps Table Figure 7-96. ATQ_CTRL8 Register 7 6 5 4 3 2 1 0 KP[7:0] R/W-00000000b Table 7-75. ATQ_CTRL8 Register Field Descriptions Bit Field Type Default Description 7-0 KP[7:0] R/W 00000000b Proportional constant for tuning the auto torque control loop.

7.6.5.9 ATQ_CTRL9 (address = 0x27) [Default = 00h]

ATQ_CTRL9 is shown in Figure 7-97 and described in Table 7-76. Read/Write Return to the Register Maps Table Figure 7-97. ATQ_CTRL9 Register 7 6 5 4 3 2 1 0 KI[3:0] KD[3:0] R/W-0000b R/W-0000b Table 7-76. ATQ_CTRL9 Register Field Descriptions Bit Field Type Default Description 7-4 KI[3:0] R/W 0000b Integral constant for tuning the auto torque control loop. 3-0 KD[3:0] R/W 0000b Differential constant for tuning the auto torque control loop.

7.6.5.10 ATQ_CTRL10 (address = 0x28) [Default = 08h]

ATQ_CTRL10 is shown in Figure 7-98 and described in Table 7-77. Read/Write Return to the Register Maps Table Figure 7-98. ATQ_CTRL10 Register 7 6 5 4 3 2 1 0 www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 91 Product Folder Links: DRV8452

Figure 7-98. ATQ_CTRL10 Register (continued) ATQ_EN LRN_START ATQ_FRZ[2:0] ATQ_AVG[2:0] R/W-0b R/W-0b R/W-001b R/W-000b Table 7-77. ATQ_CTRL10 Register Field Descriptions Bit Field Type Default Description

7 ATQ_EN R/W 0b 0 = auto torque is disabled

1 = auto torque is enabled 6 LRN_START R/W 0b Writing '1' to this bit enables the auto torque learning process. After learning is completed, the bit automatically goes to '0'. 5-3 ATQ_FRZ[2:0] R/W 001b After any output current update, delay in number of half cycles for which current update is frozen. 2-0 ATQ_AVG[2:0] R/W 000b Number of half cycles used for averaging in ATQ_COUNT calculation.

7.6.5.11 ATQ_CTRL11 (address = 0x29) [Default = 0Ah]

ATQ_CTRL11 is shown in Figure 7-99 and described in Table 7-78. Read/Write Return to the Register Maps Table Figure 7-99. ATQ_CTRL11 Register 7 6 5 4 3 2 1 0 ATQ_TRQ_MIN[7:0] R/W-00001010b Table 7-78. ATQ_CTRL11 Register Field Descriptions Bit Field Type Default Description 7-0 ATQ_TRQ_MIN[7:0] R/W 00001010b Auto torque minimum current limit.

7.6.5.12 ATQ_CTRL12 (address = 0x2A) [Default = FFh]

ATQ_CTRL12 is shown in Figure 7-100 and described in Table 7-79. Read/Write Return to the Register Maps Table Figure 7-100. ATQ_CTRL12 Register 7 6 5 4 3 2 1 0 ATQ_TRQ_MAX[7:0] R/W-11111111b Table 7-79. ATQ_CTRL12 Register Field Descriptions Bit Field Type Default Description 7-0 ATQ_TRQ_MAX[7:0] R/W 11111111b Auto torque maximum current limit.

7.6.5.13 ATQ_CTRL13 (address = 0x2B) [Default = 05h]

ATQ_CTRL13 is described below. Read/Write Return to the Register Maps Table DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

92 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Figure 7-101. ATQ_CTRL13 Register 7 6 5 4 3 2 1 0 ATQ_D_THR[7:0] R/W-00000101b Table 7-80. ATQ_CTRL13 Register Field Descriptions Bit Field Type Default Description 7-0 ATQ_D_THR R/W 00000101b Error limit above which KD is used in PID equations.

7.6.5.14 ATQ_CTRL14 (address = 0x2C) [Default = 0Fh]

ATQ_CTRL14 is described below. Read/Write Return to the Register Maps Table Figure 7-102. ATQ_CTRL14 Register 7 6 5 4 3 2 1 0 ATQ_MAX_INTEGRAL R/W-00001111b Table 7-81. ATQ_CTRL14 Register Field Descriptions Bit Field Type Default Description 7-0 ATQ_MAX_INTEGRAL R/W 00001111b Indicates the saturation point of error integration.

7.6.5.15 ATQ_CTRL15 (address = 0x2D) [Default = 00h]

ATQ_CTRL15 is described below. Read/Write Return to the Register Maps Table Figure 7-103. ATQ_CTRL15 Register 7 6 5 4 3 2 1 0 ATQ_ERROR_TRUNCATE[3:0] ATQ_LRN_STEP[1:0] ATQ_LRN_CYCLE_SELECT[1:0] R/W-0000b R/W-00b R/W-00b Table 7-82. ATQ_CTRL15 Register Field Descriptions Bit Field Type Default Description 7-4 ATQ_ERROR_TRUNCATE[3:0] R/W 0000b Number of LSB bits truncated from error before used in PID loop equations. 3-2 ATQ_LRN_STEP[1:0] R/W 00b Step increment in ATQ learn current. 1-0 ATQ_LRN_CYCLE_SELECT[1:0] R/W 00b Number of sine half cycles in one current level before which the learning routine lets the current jump to the next level.

7.6.5.16 ATQ_CTRL16 (address = 0x2E) [Default = FFh]

ATQ_CTRL16 is described below. Read only Return to the Register Maps Table www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 93 Product Folder Links: DRV8452

Figure 7-104. ATQ_CTRL16 Register 7 6 5 4 3 2 1 0 ATQ_TRQ_DAC[7:0] R-11111111b Table 7-83. ATQ_CTRL16 Register Field Descriptions Bit Field Type Default Description 7-0 ATQ_TRQ_DAC[7:0] R 11111111b Read-only. Auto torque current level readout. Note When auto-torque is disabled, ATQ_TRQ_DAC reads the value programmed to ATQ_TRQ_MAX.

7.6.5.17 ATQ_CTRL17 (address = 0x2F) [Default = 00h]

ATQ_CTRL17 is described below. Read/Write Return to the Register Maps Table Figure 7-105. ATQ_CTRL17 Register 7 6 5 4 3 2 1 0 RSVD R/W-00000000b Table 7-84. ATQ_CTRL17 Register Field Descriptions Bit Field Type Default Description 7-0 RSVD R/W 00000000b Reserved. Note The production samples will feature a VM_SCALE bit located in ATQ_CTRL17 bit 6. When enabled, this bit will modify the auto-torque learning routine parameters in the event of a supply voltage change. In pre-production samples, this bit will be reserved.

7.6.5.18 ATQ_CTRL18 (address = 0x30) [Default = 00h]

ATQ_CTRL18 is described below. Read/Write Return to the Register Maps Table Figure 7-106. ATQ_CTRL18 Register 7 6 5 4 3 2 1 0 RSVD VREF_INT_EN RSVD R/W-00b R/W-0b R/W-00000b Table 7-85. ATQ_CTRL18 Register Field Descriptions Bit Field Type Default Description 7-6 RSVD R/W 00b Reserved. 5 VREF_INT_EN R/W 0b 1b = Enables internal 3.3V reference voltage 0b = Device works with external reference voltage (VREF pin) DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

94 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Table 7-85. ATQ_CTRL18 Register Field Descriptions (continued) Bit Field Type Default Description 4 RSVD R/W 00000b Reserved. Note The VREF_INT_EN bit is located in ATQ_CTRL18 register bit 5 in pre-production samples. For production samples, the VREF_INT_EN bit will be located in CTRL13 register bit 1.

7.6.6 Silent Step Registers

The silent step registers control the silent step decay mode. Silent step registers are read and write capable. Table 7-86 lists the memory-mapped registers for the silent step registers. All register offset addresses not listed in Table 7-86 should be considered as reserved locations and the register contents should not be modified. Table 7-86. Silent step Registers Summary Table Address Register Name Section 0x31 SS_CTRL1 Go 0x32 SS_CTRL2 Go 0x33 SS_CTRL3 Go 0x34 SS_CTRL4 Go 0x35 SS_CTRL5 Go

7.6.6.1 SS_CTRL1 (address = 0x31) [Default = 00h]

SS_CTRL1 is shown in Figure 7-107 and described in Table 7-87. Read/Write Return to the Register Maps Table Figure 7-107. SS_CTRL1 Register 7 6 5 4 3 2 1 0 RSVD SS_PWM_FREQ[1:0] RSVD EN_SS R/W-0000b R/W-00b R/W-0b R/W-0b Table 7-87. SS_CTRL1 Register Field Descriptions Bit Field Type Default Description 7-4 RSVD R/W 0000b Reserved 3-2 SS_PWM_FREQ[1:0] R/W 00b Silent step decay PWM frequency configuration 00b - 25KHz 01b - 33KHz 10b - 42KHz 11b - 50KHz

1 RSVD R/W 0b Reserved

0 EN_SS R/W 0b 0b = silentstep decay mode is disabled

1b = silentstep decay mode is enabled

7.6.6.2 SS_CTRL2 (address = 0x32) [Default = 00h]

SS_CTRL2 is shown in Figure 7-108 and described in Table 7-88. Read/Write www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 95 Product Folder Links: DRV8452

Return to the Register Maps Table Figure 7-108. SS_CTRL2 Register 7 6 5 4 3 2 1 0 RSVD SS_KP[6:0] R/W - 0b R/W-0000000b Table 7-88. SS_CTRL2 Register Field Descriptions Bit Field Type Default Description 7 RSVD R/W 0b Reserved. 6-0 SS_KP[6:0] R/W 0000000b Silent step decay mode proportional constant of the compensation loop. Range from 0 to 127.

7.6.6.3 SS_CTRL3 (address = 0x33) [Default = 00h]

SS_CTRL3 is shown in Figure 7-109 and described in Table 7-89. Read/Write Return to the Register Maps Table Figure 7-109. SS_CTRL3 Register 7 6 5 4 3 2 1 0 RSVD SS_KI[6:0] R/W-0b R/W-0000000b Table 7-89. SS_CTRL3 Register Field Descriptions Bit Field Type Default Description 7 RSVD R/W 0b Reserved. 6-0 SS_KI[6:0] R/W 0000000b Silent step decay mode integral constant of the compensation loop. Range from 0 to 255.

7.6.6.4 SS_CTRL4 (address = 0x34) [Default = 00h]

SS_CTRL4 is shown in Figure 7-110 and described in Table 7-90. Read/Write Return to the Register Maps Table Figure 7-110. SS_CTRL4 Register 7 6 5 4 3 2 1 0 RSVD SS_KI_DIV_SEL[2:0] RSVD SS_KP_DIV_SEL[2:0] R/W-0b R/W-000b R/W-0b R/W-000b Table 7-90. SS_CTRL4 Register Field Descriptions Bit Field Type Default Description

7 RSVD R/W 0b Reserved

SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

96 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

Table 7-90. SS_CTRL4 Register Field Descriptions (continued) Bit Field Type Default Description 6-4 SS_KI_DIV_SEL[2:0] R/W 000b Silent step decay mode KI divider Actual KI = SS_KI/SS_KI_DIV_SEL 000b - SS_KI/32 001b - SS_KI/64 010b - SS_KI/128 011b - SS_KI/256 100b - SS_KI/512 101b - SS_KI/16 110b - SS_KI 3-1 RSVD R/W 0b Reserved

0 SS_KP_DIV_SEL[2:0] R/W 000b Silent step decay mode KP divider

Actual KP = SS_KP/SS_KP_DIV_SEL 000b - SS_KP/32 001b - SS_KP/64 010b - SS_KP/128 011b - SS_KP/256 100b - SS_KP/512 101b - SS_KP/16 110b - SS_KP

7.6.6.5 SS_CTRL5 (address = 0x35) [Default = FFh]

SS_CTRL5 is shown in Figure 7-111 and described in Table 7-91. Read/Write Return to the Register Maps Table Figure 7-111. SS_CTRL5 Register 7 6 5 4 3 2 1 0 SS_THR[7:0] R/W-11111111b Table 7-91. SS_CTRL5 Register Field Descriptions Bit Field Type Default Description 7-0 SS_THR[7:0] R/W 11111111b Programs the frequency at which the device transitions from silent step decay mode to another decay mode programmed by the DECAY bits. This frequency corresponds to the frequency of the sinusoidal current waveform. 00000001b = 2 Hz 00000010b = 4 Hz 11111111b = 510 Hz Note Do not set SS_THR to 00000000b. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 97 Product Folder Links: DRV8452

8 Application and Implementation

Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes, as well as validating and testing their design implementation to confirm system functionality.

8.1 Application Information

The DRV8452 is used in bipolar stepper control.

8.2 Typical Application

The following design procedure can be used to configure the DRV8452. CPL CPH VCP VM PGNDA AOUT1 AOUT2 BOUT2 BOUT1 PGNDB VM GND ENABLE DIR STEP nSLEEP SCLK SDI SDO nSCS VCC VREF nFAULT DVDD DRV8452 VM Step Motor + – VM 0.01 F100 F 0.1 F 1 F 0.01 F 1 F RREF1 RREF2 VCC 10 kΩ + – nHOME 10 kΩ MODE 0.1 F Figure 8-1. Typical Application Schematic

8.2.1 Design Requirements

Table 8-1 lists the design input parameters for system design. Table 8-1. Design Parameters DESIGN PARAMETER REFERENCE EXAMPLE VALUE Supply voltage VM 24 V Motor winding resistance RL 0.5 Ω/phase Motor winding inductance LL 0.4 mH/phase Motor full step angle θstep 1.8°/step Target microstepping level nm 1/32 step Target motor speed v 50 rpm Target full-scale current IFS 5 A DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

98 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

8.2.2 Detailed Design Procedure

8.2.2.1 Stepper Motor Speed

The first step in configuring the DRV8452 requires the desired motor speed and microstepping level. If the target application requires a constant speed, then a square wave with frequency ƒstep must be applied to the STEP pin. If the target motor speed is too high, the motor does not spin. Make sure that the motor can support the target speed. Use Equation 12 to calculate ƒstep for a desired motor speed (v), microstepping level (n m), and motor full step angle (θstep) step step m v (rpm) 360 ( / rot)¦ VWHSV V ( / step) n (steps / microstep) 60 (s / min) u q T q u u (12) The value of θstep can be found in the stepper motor data sheet, or written on the motor. For example, the motor in this application is required to rotate at 1.8°/step for a target of 50 rpm at 1/32 microstep mode. Using Equation 12, ƒstep can be calculated as 5300 Hz. The microstepping level is set by the M0 and M1 pins or the MICROSTEP_MODE bits and can be any of the settings listed in Table 7-5. Higher microstepping results in a smoother motor motion and less audible noise, but requires a higher ƒstep to achieve the same motor speed.

8.2.3 Thermal Application

This section presents the power dissipation calculation and junction temperature estimation of the device.

8.2.3.1 Power Dissipation

The total power dissipation constitutes of three main components - conduction loss (P COND), switching loss (PSW) and power loss due to quiescent current consumption (PQ).

8.2.3.2 Conduction Loss

The current path for a motor connected in full-bridge is through the high-side FET of one half-bridge and low-side FET of the other half-bridge. The conduction loss (PCOND) depends on the motor rms current (IRMS) and high-side (RDS(ONH)) and low-side (RDS(ONL)) on-state resistances as shown in Equation 13. PCOND = 2 x (IRMS)2 x (RDS(ONH) + RDS(ONL)) (13) The conduction loss for the typical application shown in Table 8-1 is calculated in Equation 14. PCOND = 2 x (IRMS)2 x (RDS(ONH) + RDS(ONL)) = 2 x (5-A / √2)2 x (0.1-Ω) = 2.5-W (14) Note This power calculation is highly dependent on the device temperature which significantly effects the high-side and low-side on-resistance of the FETs. For more accurate calculation, consider the dependency of on-resistance of FETs with device temperature.

8.2.3.3 Switching Loss

The power loss due to the PWM switching frequency depends on the output voltage rise/fall time (t RF), supply voltage, motor RMS current and the PWM switching frequency. The switching losses in each H-bridge during rise-time and fall-time are calculated as shown in Equation 15 and Equation 16. PSW_RISE = 0.5 x VVM x IRMS x tRF x fPWM (15) PSW_FALL = 0.5 x VVM x IRMS x tRF x fPWM (16) The DRV8452 features two values of output rise/fall time (t RF) - 140 ns and 70 ns. The smaller rise/fall time obviously results in lesser switching loss. Assuming t RF = 140 ns and 30-kHz PWM frequencyfor this exercise, www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 99 Product Folder Links: DRV8452

and after substituting the values of various parameters, the switching losses in each H-bridge are calculated as shown below - PSW_RISE = 0.5 x 24-V x (5-A / √2) x (140 ns) x 30-kHz = 0.178-W (17) PSW_FALL = 0.5 x 24-V x (5-A / √2) x (100 ns) x 30-kHz = 0.178-W (18) The total switching loss for the stepper motor driver (P SW) is calculated as twice the sum of rise-time (P SW_RISE) switching loss and fall-time (PSW_FALL) switching loss as shown below - PSW = 2 x (PSW_RISE + PSW_FALL) = 2 x (0.178-W + 0.178-W) = 0.712-W (19) Note The output rise/fall time (t RF) is expected to change based on the supply-voltage, temperature and device to device variation. The switching loss is directly proportional to the PWM switching frequency. The PWM frequency in an application will depend on the supply voltage, inductance of the motor coil, back emf voltage and OFF time or the ripple current (for smart tune ripple control decay mode).

8.2.3.4 Power Dissipation Due to Quiescent Current

When the VCC pin is connected to an external voltage, the quiescent current is typically 5 mA. The power dissipation due to the quiescent current consumed by the power supply is calculated as shown below - PQ = VVM x IVM (20) Substituting the values, quiescent power loss can be calculated as shown below - Note The quiescent power loss is calculated using the typical operating supply current (I VM) which is dependent on supply-voltage, temperature and device to device variations.

8.2.3.5 Total Power Dissipation

The total power dissipation (P TOT) is calculated as the sum of conduction loss, switching loss and the quiescent power loss as shown in Equation 22. PTOT = PCOND + PSW + PQ = 2.5-W + 0.712-W + 0.12-W = 3.332-W (22)

8.2.3.5.1 Device Junction Temperature Estimation

For an ambient temperature of T A and total power dissipation (P TOT), the junction temperature (T J) is calculated as - TJ = TA + (PTOT x RθJA) Considering a JEDEC standard 4-layer PCB, the junction-to-ambient thermal resistance (R θJA) is 22.5 °C/W for the DDW package and 24.5 °C/W for the PWP package. Assuming 25°C ambient temperature, the junction temperature for the DDW package is calculated as shown below - The junction temperature for the PWP package is calculated as shown below - DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

100 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

As explained before, for more accurate calculation, consider the dependency of on-resistance of FETs with device junction temperature shown in the Typical Operating Characteristics section. For example,

  • At 100 °C junction temperature, the on-resistance will likely increase by a factor of 1.3 compared to the on-resistance at 25 °C.
  • The initial estimate of conduction loss was 2.5 W.
  • New estimate of conduction loss will therefore be 2.5 W x 1.3 = 3.25 W.
  • New estimate of the total power loss will accordingly be 4.082 W.
  • New estimate of junction temperature for the DDW package will be 116.8 °C.
  • Further iterations are unlikely to increase the junction temperature estimate by significant amount. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 101 Product Folder Links: DRV8452

9 Thermal Considerations

9.1 Thermal Pad

Thermal pad of both DDW and PWP packages is attached at bottom of device to improve the thermal capability of the device. The thermal pad has to be soldered with a very good coverage on PCB in order to deliver the power specified in the datasheet. Refer to the Layout Guidelines section for more details.

9.2 PCB Material Recommendation

FR-4 Glass Epoxy material with 2 oz. (70 μm) copper on both top and bottom layer is recommended for improved thermal performance and better EMI margin (due to lower PCB trace inductance). DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

102 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

10 Power Supply Recommendations

The DRV8452 device is designed to operate from an input voltage supply (VM) range from 4.5 V to 48 V. A 0.01-µF ceramic capacitor rated for VM must be placed close to the VM pins of DRV8452. In addition, a bulk capacitor must be included on VM.

10.1 Bulk Capacitance

Having appropriate local bulk capacitance is an important factor in motor drive system design. It is generally beneficial to have more bulk capacitance, while the disadvantages are increased cost and physical size. The amount of local capacitance needed depends on a variety of factors, including:

  • The highest current required by the motor system
  • The power supply’s capacitance and ability to source current
  • The amount of parasitic inductance between the power supply and motor system
  • The acceptable voltage ripple
  • The type of motor used (brushed DC, brushless DC, stepper)
  • The motor braking method The inductance between the power supply and motor drive system will limit the rate current can change from the power supply. If the local bulk capacitance is too small, the system will respond to excessive current demands or dumps from the motor with a change in voltage. When adequate bulk capacitance is used, the motor voltage remains stable and high current can be quickly supplied. The data sheet generally provides a recommended value, but system-level testing is required to determine the appropriate sized bulk capacitor. The voltage rating for bulk capacitors should be higher than the operating voltage, to provide margin for cases when the motor transfers energy to the supply. Local Bulk Capacitor Parasitic Wire Inductance Motor Driver Power Supply Motor Drive System VM GND IC Bypass Capacitor Copyright © 2016, Texas Instruments Incorporated Figure 10-1. Example Setup of Motor Drive System With External Power Supply

10.2 Power Supplies

The DRV8452 needs only a single supply voltage connected to the VM pins.

  • The VM pin provides the power supply to the H-Bridges.
  • An internal voltage regulator provides a 5V supply (DVDD) for the digital and low-voltage analog circuitry. The DVDD pin is not recommended to be used as a voltage source for external circuitry.
  • An external low-voltage supply can be connected to the VCC pin to power the internal circuitry. A 0.1-µF decoupling capacitor should be placed close to the VCC pin to provide a constant voltage during transient.
  • Additionally, the high-side gate drive requires a higher voltage supply, which is generated by the built-in charge pump. The charg pump requires external capacitors. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 103 Product Folder Links: DRV8452

11 Layout

11.1 Layout Guidelines

  • The VM pins should be bypassed to PGND pins using low-ESR ceramic bypass capacitors with a recommended value of 0.01 µF rated for VM. The capacitors should be placed as close to the VM pins as possible with a thick trace or ground plane connection to the device PGND pins.
  • The VM pins should be bypassed to PGND using a bulk capacitor rated for VM. This component can be an electrolytic capacitor.
  • A low-ESR ceramic capacitor must be placed in between the CPL and CPH pins. A value of 0.1 µF rated for VM is recommended. Place this component as close to the pins as possible.
  • A low-ESR ceramic capacitor must be placed in between the VM and VCP pins. A value of 1 µF rated for 16 V is recommended. Place this component as close to the pins as possible.
  • Bypass the DVDD pin to ground with a low-ESR ceramic capacitor. A value of 1 µF rated for 6.3 V is recommended. Place this bypassing capacitor as close to the pin as possible.
  • Bypass the VCC pin to ground with a low-ESR ceramic capacitor. A value of 0.1 µF rated for 6.3 V is recommended. Place this bypassing capacitor as close to the pin as possible.
  • In general, inductance between the power supply pins and decoupling capacitors must be avoided.
  • The thermal PAD of the package must be connected to system ground. – It is recommended to use a big unbroken single ground plane for the whole system / board. The ground plane can be made at bottom PCB layer. – In order to minimize the impedance and inductance, the traces from ground pins should be as short and wide as possible, before connecting to bottom layer ground plane through vias. – Multiple vias are suggested to reduce the impedance. – Try to clear the space around the device as much as possible especially at bottom PCB layer to improve the heat spreading. – Single or multiple internal ground planes connected to the thermal PAD will also help spreading the heat and reduce the thermal resistance.

11.2 Layout Example

Follow the layout example of the DRV8452 EVM. The design files can be downloaded from the DRV8452EVM product folder. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

104 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

12 Device and Documentation Support

TI offers an extensive line of development tools. Tools and software to evaluate the performance of the device, generate code, and develop solutions are listed below.

12.1 Related Documentation

  • Texas Instruments, How to Reduce Audible Noise in Stepper Motors application report
  • Texas Instruments, How to Improve Motion Smoothness and Accuracy application report
  • Texas Instruments, How to Drive Unipolar Stepper Motors with DRV8xxx application report
  • Texas Instruments, Calculating Motor Driver Power Dissipation application report
  • Texas Instruments, Current Recirculation and Decay Modes application report
  • Texas Instruments, Understanding Motor Driver Current Ratings application report
  • Texas Instruments, Motor Drives Layout Guide application report
  • Texas Instruments, Semiconductor and IC Package Thermal Metrics application report

12.2 Receiving Notification of Documentation Updates

To receive notification of documentation updates, navigate to the device product folder on ti.com. Click on Subscribe to updates to register and receive a weekly digest of any product information that has changed. For change details, review the revision history included in any revised document.

12.3 Support Resources

TI E2E™ support forums are an engineer's go-to source for fast, verified answers and design help — straight from the experts. Search existing answers or ask your own question to get the quick design help you need. Linked content is provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use.

12.4 Trademarks

12.5 Electrostatic Discharge Caution

This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.

12.6 Glossary

TI Glossary This glossary lists and explains terms, acronyms, and definitions. www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 105 Product Folder Links: DRV8452

13 Mechanical, Packaging, and Orderable Information

The following pages include mechanical, packaging, and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation. DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

106 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 107 Product Folder Links: DRV8452

SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

108 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 109 Product Folder Links: DRV8452

SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

110 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 111 Product Folder Links: DRV8452

SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

112 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

13.1 Tape and Reel Information

Reel Width (W1) REEL DIMENSIONS W Dimension designed to accommodate the component length Dimension designed to accommodate the component thickness Overall width of the carrier tape Pitch between successive cavity centers Dimension designed to accommodate the component width TAPE DIMENSIONS B0 W A0Cavity QUADRANT ASSIGNMENTS FOR PIN 1 ORIENTATION IN TAPE Pocket Quadrants Sprocket Holes Q1 Q1Q2 Q2 Q3 Q3Q4 Q4 Reel Diameter User Direction of Feed Device Package Type Package Drawing Pins SPQ Reel Diameter (mm) Reel Width W1 (mm) (mm) (mm) (mm) (mm) W (mm) Pin1 Quadrant www.ti.com DRV8452 SLOSE84 – AUGUST 2022 ADVANCE INFORMATION Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 113 Product Folder Links: DRV8452

TAPE AND REEL BOX DIMENSIONS Width (mm) W L H Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) DRV8452PWPR HTSSOP PWP 28 2500 356.0 356.0 35.0 DRV8452SPWPR HTSSOP PWP 28 2500 356.0 356.0 35.0 DRV8452DDWR HTSSOP PWP 44 2500 367.0 367.0 45.0 DRV8452 SLOSE84 – AUGUST 2022 www.ti.com ADVANCE INFORMATION

114 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated

Product Folder Links: DRV8452

www.ti.com 19-Aug-2022 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Drawing Pins Package Qty Eco Plan (2) Lead finish/ Ball material (6) MSL Peak Temp (3) Op Temp (°C) Device Marking (4/5) Samples PDRV8452DDWR ACTIVE HTSSOP DDW 44 2500 TBD Call TI Call TI -40 to 125 Samples (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of <=1000ppm threshold. Antimony trioxide based flame retardants must also meet the <=1000ppm threshold requirement. (3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. (4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device. (5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device. (6) Lead finish/Ball material - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead finish/Ball material values may wrap to two lines if the finish value exceeds the maximum column width. Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 1

www.ti.com GENERIC PACKAGE VIEW This image is a representation of the package family, actual package may vary. Refer to the product data sheet for package details. PowerPAD TSSOP - 1.2 mm max heightDDW 44 PLASTIC SMALL OUTLINE6.1 x 14, 0.635 mm pitch 4224876/A

IMPORTANT NOTICE AND DISCLAIMER TI PROVIDES TECHNICAL AND RELIABILITY DATA (INCLUDING DATA SHEETS), DESIGN RESOURCES (INCLUDING REFERENCE DESIGNS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, SAFETY INFORMATION, AND OTHER RESOURCES “AS IS” AND WITH ALL FAULTS, AND DISCLAIMS ALL WARRANTIES, EXPRESS AND IMPLIED, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF THIRD PARTY INTELLECTUAL PROPERTY RIGHTS. These resources are intended for skilled developers designing with TI products. You are solely responsible for (1) selecting the appropriate TI products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable standards, and any other safety, security, regulatory or other requirements. These resources are subject to change without notice. TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource. Other reproduction and display of these resources is prohibited. No license is granted to any other TI intellectual property right or to any third party intellectual property right. TI disclaims responsibility for, and you will fully indemnify TI and its representatives against, any claims, damages, costs, losses, and liabilities arising out of your use of these resources. TI’s products are provided subject to TI’s Terms of Sale or other applicable terms available either on ti.com or provided in conjunction with such TI products. TI’s provision of these resources does not expand or otherwise alter TI’s applicable warranties or warranty disclaimers for TI products. TI objects to and rejects any additional or different terms you may have proposed. IMPORTANT NOTICE Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2022, Texas Instruments Incorporated