cui.com date 11/25/2020 page 1 of 6 SERIES: PDRB-60 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY MODEL output1 voltage output current output power ripple and noise2 efficiency3 (Vdc) range (Vdc) max (A) max (W) max (mVp-p) typ (%) PDRB-60-5 5 4.9 ~ 5.5 6.5 33 100 84 PDRB-60-12 12 10.8 ~ 13.8 4.5 54 120 88 PDRB-60-15 15 13.5 ~ 18.0 4.0 60 120 89 PDRB-60-24 24 21.6 ~ 29.0 2.5 60 150 90 PDRB-60-48 48 43.2 ~ 55.2 1.25 60 240 91 Notes: 1. Output adjustable via built-in trimpot. The actual adjustment range may extend beyond the values listed and care should be taken to ensure the output voltage and output power do not exceed stated limits. 2. At full load, nominal input, 20 MHz bandwidth oscilloscope. 3. At 230 Vac input.

FEATURES

  • universal input range (85 ~ 264 Vac)
  • IEC/EN/UL 62368 certified
  • designed to meet 61558 system requirements
  • over Voltage Category (OVC) III design
  • over voltage, over current, and short circuit protections
  • 4kVac isolation input to output
  • withstand up to 300 Vac input surge events
  • Class B emissions PART NUMBER KEY Base Number PDRB-60 - XX Output Voltage Additional Resources: Product Page | 3D Model

cui.com date 11/25/2020 │ page 2 of 6CUI Inc │ SERIES: PDRB-60 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY INPUT parameter conditions/description min typ max units input voltage ac input dc input 120 264 370 Vac Vdc frequency 47 63 Hz current at 115 Vac at 230 Vac 1.2 0.8 A A inrush current at 115 Vac at 230 Vac A A leakage current at 264 Vac 0.25 mA OUTPUT parameter conditions/description min typ max units capacitive load

5 Vdc output models

12 Vdc output models

15 Vdc output models

24 Vdc output models

48 Vdc output models

20,000 10,000 8,000 4,000 680 µF µF µF µF µF initial set point accuracy 0% ~ 100% load ±2 % line regulation at rated load ±0.5 % load regulation at 230 Vac ±1.5 % start-up time 3 s hold-up time at 115 Vac at 230 Vac ms ms switching frequency 65 kHz temperature coefficient ±0.02 %/°C no load power consumption at 230 Vac

5 Vdc, 12 Vdc, 15 Vdc, 24 Vdc output models

0.3 0.4 W W PROTECTIONS parameter conditions/description min typ max units over voltage protection clamp or hiccup 7.5 Vdc Vdc Vdc Vdc Vdc over current protection auto recovery 120 % short circuit protection continuous, auto recovery, hiccup Additional Resources: Product Page | 3D Model

cui.com date 11/25/2020 │ page 3 of 6CUI Inc │ SERIES: PDRB-60 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY ENVIRONMENTAL parameter conditions/description min typ max units operating temperature see the derating curve -40 70 °C storage temperature -40 85 °C storage humidity non-condensing 0 95 % altitude 2,000 m SAFETY & COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output 5 mA for 1 minute 4,000 Vac safety approvals certified to 62368:IEC, EN, UL/cUL safety class Class II conducted emissions CISPR32/EN55032 CLASS B radiated emissions CISPR32/EN55032 CLASS B ESD IEC/EN61000-4-2 Contact ±6KV/Air ±8KV perf. Criteria A radiated immunity IEC/EN61000-4-3 10V/m perf. Criteria A EFT/burst IEC/EN61000-4-4 ±2KV perf. Criteria A surge IEC/EN61000-4-5 line to line ±2KV perf. Criteria A conducted immunity IEC/EN61000-4-6 10Vr.m.s perf. Criteria A voltage dips and interruption IEC/EN61000-4-11 0%, 70% perf. Criteria A MTBF as per MIL-HDBK-217F at 25°C 300,000 hours RoHS yes Additional Resources: Product Page | 3D Model

cui.com date 11/25/2020 │ page 4 of 6CUI Inc │ SERIES: PDRB-60 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY units: mm [inch] ADJ: built-in trimpot wire range: 24-12 AWG tightening torque: Max 0.4 N·m mounting rail: TS35 general tolerances: ±1.0 [±0.039] TERMINAL CONNECTIONS TERMINAL Function

1 AC (L)

2 AC (N)

parameter conditions/description min typ max units dimensions 92.66 x 52.00 x 58.00 mm material plastic, heat-resistant (UL94V-0) weight 175 g cooling natural convection MECHANICAL DRAWING Additional Resources: Product Page | 3D Model

cui.com date 11/25/2020 │ page 5 of 6CUI Inc │ SERIES: PDRB-60 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY EFFICIENCY CURVES DERATING CURVE Additional Resources: Product Page | 3D Model

date 11/25/2020 │ page 6 of 6CUI Inc │ SERIES: PDRB-60 │ DESCRIPTION: AC-DC DIN RAIL POWER SUPPLY CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com rev. description date 1.0 initial release 11/25/2020 The revision history provided is for informational purposes only and is believed to be accurate.

REVISION HISTORY

Additional Resources: Product Page | 3D Model