PDQE15-U CUI | Alldatasheet
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 10
Technical content
cui.com date 02/07/2022 page 1 of 10 SERIES: PDQE15-U │ DESCRIPTION: DC-DC CONVERTER
FEATURES
- up to 15 W isolated output
- 1,500 Vdc isolation
- ultra-wide 4:1 input range (9~36 Vdc, 18~75 Vdc)
- same side input/output connections
- single/dual regulated outputs
- input under-voltage, output short-circuit, over-current, & over-voltage protections
- wide operating temperature range (-40~105°C)
- efficiency up to 91%
- EN 62368-1
- meets UL 62368 MODEL input voltage output voltage output current output power ripple & noise1 efficiency2 typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) max (mVp-p) typ (%) PDQE15-Q24-D5-U 24 9~36 ±5 0 ±1500 15 200 87 PDQE15-Q24-D12-U 24 9~36 ±12 0 ±625 15 200 90 PDQE15-Q24-D15-U 24 9~36 ±15 0 ±500 15 200 90 PDQE15-Q24-D24-U 24 9~36 ±24 0 ±312 15 200 89 PDQE15-Q24-S3-U 24 9~36 3.3 0 4000 13.2 100 88 PDQE15-Q24-S5-U 24 9~36 5 0 3000 15 100 90 PDQE15-Q24-S12-U 24 9~36 12 0 1250 15 100 90 PDQE15-Q24-S15-U 24 9~36 15 0 1000 15 100 91 PDQE15-Q24-S24-U 24 9~36 24 0 625 15 100 91 PDQE15-Q48-D5-U 48 18~75 ±5 0 ±1500 15 200 86 PDQE15-Q48-D12-U 48 18~75 ±12 0 ±625 15 200 89 PDQE15-Q48-D15-U 48 18~75 ±15 0 ±500 15 200 89 PDQE15-Q48-D24-U 48 18~75 ±24 0 ±312 15 200 90 PDQE15-Q48-S3-U 48 18~75 3.3 0 4000 13.2 100 88 PDQE15-Q48-S5-U 48 18~75 5 0 3000 15 100 90 PDQE15-Q48-S12-U 48 18~75 12 0 1250 15 100 91 PDQE15-Q48-S15-U 48 18~75 15 0 1000 15 100 91 PDQE15-Q48-S24-U 48 18~75 24 0 625 15 100 91 Notes: 1. From 5~100% load, 20 MHz bandwidth oscilloscope, using the “parallel cable” method for testing. From 0~5% load, ripple and noise is <±5% Vo. 2. Measured at nominal input voltage and rated load. 3. All specifications are measured at Ta=25°C, humidity < 75%, nominal input voltage, and rated output load unless otherwise specified. Additional Resources: Product Page | 3D Model
cui.com date 02/07/2022 │ page 2 of 10CUI Inc │ SERIES: PDQE15-U │ DESCRIPTION: DC-DC CONVERTER INPUT parameter conditions/description min typ max units operating input voltage 24 Vdc input models
48 Vdc input models
start-up voltage 24 Vdc input models
24 Vdc input models
-0.7 -0.7 100 Vdc Vdc under voltage shutdown 24 Vdc input models 5.5 6.5 15.5 Vdc Vdc current (full load/no load) dual output models
24 Vdc input models 719/10 735/20 mA
48 Vdc input models 364/5 372/11 mA
24 Vdc input
3.3 Vdc output
5 Vdc output
12 Vdc output
15 Vdc output
24 Vdc output
48 Vdc input
remote on/off (CTRL) module ON (3.5~12 Vdc or CTRL pin open circuit or pulled high) module OFF (0~1.2 Vdc CTRL pin pulled low to GND) input current when switched off 2 7 mA start-up time nominal input, constant resistance load 10 ms filter Pi filter OUTPUT parameter conditions/description min typ max units maximum capacitive load4 3.3, 5 Vdc output models ±5 Vdc output models
12 Vdc output models
±12 Vdc output models
15 Vdc output models
±15 Vdc output models
24 Vdc output models
±24 Vdc output models 4,700 1,500 1,000 470 820 330 270 200 μF μF μF μF μF μF μF μF voltage accuracy5 0% to full load ±1 ±3 % line regulation from low line to high line, full load positive outputs negative outputs ±0.2 ±0.5 ±0.5 load regulation6 from 5% to full load ±0.5 ±1 % PART NUMBER KEY Base Number PDQE15 - QXX - X XX - U Input Voltage Output Voltage Mounting Style: U = U-frameOutput: S = single D = dual Additional Resources: Product Page | 3D Model
cui.com date 02/07/2022 │ page 3 of 10CUI Inc │ SERIES: PDQE15-U │ DESCRIPTION: DC-DC CONVERTER OUTPUT (CONTINUED) parameter conditions/description min typ max units cross regulation dual output models: positive output 50% load secondary output from 10~100% load ±5 % switching frequency7 PWM mode 3.3, 5 Vdc output models all other output models 300 270 kHz kHz transient recovery time 25% load step change, nominal input voltage 300 500 μs transient response deviation 25% load step change, nominal input voltage 3.3, 5 Vdc output models ±5 Vdc output model all other output models temperature coefficient at full load ±0.03 %/°C Note: 4. Specified maximum capacitive load for positive and negative outputs is identical. 5. Output voltage accuracy of ±5 Vdc/±9 Vdc output converter for 0%~5% load is ±5% max. 6. Load regulation for 0%~100% load is ±5%. 7. Switching frequency is measured at full load. Module reduces switching frequency at light load (blow 50%), to increase efficiency. PROTECTIONS parameter conditions/description min typ max units over voltage protection 110 160 % over current protection single output models dual output models 110 110 150 200 190 270 short circuit protection continuous, auto recovery SAFETY AND COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute at 1 mA input to output-case for 1 minute at 1 mA 1,500 1,000 Vdc Vdc isolation resistance input to output at 500 Vdc 1,000 MΩ isolation capacitance input to output, 100 kHz / 0.1 V 2,000 pF safety approvals certified to 62368: EN, IEC conducted emissions CISPR32/EN55032 CLASS A (without extra components), CLASS B (see Fig. 3-2) EN50121-3-2 150kHz-500kHz 99dBuV (see Fig. 3-2) EN55016-2-1 500kHz-30MHz 93dBuV (see Fig. 3-2) radiated emissions CISPR32/EN55032 CLASS A (without extra components), CLASS B (see Fig. 3-2) EN50121-3-2 30MHz-230MHz 40dBuV/m at 10m (see Fig. 3-2) EN55016-2-1 230MHz-1GHz 47dBuV/m at 10m (see Fig.3-2) ESD IEC/EN61000-4-2 Contact ±4kV, perf. Criteria B EN50121-3-2 Contact ±6KV/Air ±8KV, perf. Criteria A radiated immunity IEC/EN61000-4-3 10V/m, perf. Criteria A EN50121-3-2 20V/m, perf Criteria A EFT/burst IEC/EN61000-4-4 ±2kV (see Fig. 3-1), perf. Criteria B EN50121-3-2 ±2kV 5/50ns 5kHz (see Fig. 3-1), perf. Criteria A surge IEC/EN61000-4-5 line to line ±2kV (see Fig. 3-1), perf. Criteria B EN50121-3-2 line to line ±1KV (42Ω , 0.5µF) (see Fig. 3-1), perf. Criteria A conducted immunity IEC/EN61000-4-6 3 Vr.m.s, perf. Criteria A EN50121-3-2 0.15MHz-80MHz 10V r.m.s, perf. Criteria A MTBF as per MIL-HDBK-217F, 25°C 1,000,000 hours RoHS yes Additional Resources: Product Page | 3D Model
cui.com date 02/07/2022 │ page 4 of 10CUI Inc │ SERIES: PDQE15-U │ DESCRIPTION: DC-DC CONVERTER ENVIRONMENTAL parameter conditions/description min typ max units operating temperature see derating curve 3.3, 5 Vdc output models all other output models -40 -40 105 storage temperature -55 125 °C storage humidity non-condensing 5 95 % DERATING CURVES SOLDERABILITY parameter conditions/description min typ max units pin soldering resistance temperature 1.5 mm from case for 10 seconds 300 °C Additional Resources: Product Page | 3D Model
cui.com date 02/07/2022 │ page 5 of 10CUI Inc │ SERIES: PDQE15-U │ DESCRIPTION: DC-DC CONVERTER units: mm [inch] wire range: 24-12 AWG tolerance: ±1.00[±0.039] tightening torque: Max 0.4 N·m MECHANICAL parameter conditions/description min typ max units case material aluminum alloy weight 46 g MECHANICAL DRAWING PIN CONNECTIONS PIN Function Single Dual
1 GND GND
2 Vin Vin
3 Ctrl Ctrl
4 Case Case
5 NC NC
7 Trim 0V
Additional Resources: Product Page | 3D Model
cui.com date 02/07/2022 │ page 6 of 10CUI Inc │ SERIES: PDQE15-U │ DESCRIPTION: DC-DC CONVERTER EFFICIENCY CURVES Additional Resources: Product Page | 3D Model
cui.com date 02/07/2022 │ page 7 of 10CUI Inc │ SERIES: PDQE15-U │ DESCRIPTION: DC-DC CONVERTER EFFICIENCY CURVES (CONTINUED) Additional Resources: Product Page | 3D Model
cui.com date 02/07/2022 │ page 9 of 10CUI Inc │ SERIES: PDQE15-U │ DESCRIPTION: DC-DC CONVERTER TRIM FUNCTION Figure 4 Trim Function for Output Voltage Adjustment (open if unused) Calculating Trim Resistor Values: Note: RT = Trim Resistance a = Self-defined parameter with no real meaning Vout (V) R1 (kΩ) R2 (kΩ) R3 (kΩ) Vref (V) 3.3 4.801 2.87 15 1.25 5 2.894 10 2.5 12 11.000 17.4 15 14.494 24 24.872 20 Table 3 Additional Resources: Product Page | 3D Model
date 02/07/2022 │ page 10 of 10CUI Inc │ SERIES: PDQE15-U │ DESCRIPTION: DC-DC CONVERTER CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com
REVISION HISTORY
rev. description date 1.0 initial release 12/06/2021 1.01 Vref updated for 3.3 Vdc output model 02/07/2022 The revision history provided is for informational purposes only and is believed to be accurate. Additional Resources: Product Page | 3D Model