PDQ15-Q24-S3-D CUI | Alldatasheet
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 9
Technical content
cui.com date 07/12/2016 page 1 of 9 SERIES: PDQ15-D │ DESCRIPTION: DC-DC CONVERTER
FEATURES
- up to 15 W isolated output
- industry standard 1” x 1” package
- 4:1 input range
- single/dual regulated output
- over voltage, input under voltage lockout, and short circuit protections
- 1,500 Vdc isolation voltage
- five-sided shielded case
- remote on/off control
- output trim
- -40 to 105°C temperature range
- efficiency up to 88% MODEL input voltage output voltage output current output power ripple & noise1 efficiency typ (Vdc) range (Vdc) (Vdc) min (A) max (A) max (W) max (mVp-p) typ (%) PDQ15-Q24-S3-D 24 9~36 3.3 0 4.0 13.2 75 87 PDQ15-Q24-S5-D 24 9~36 5 0 3.0 15 75 87 PDQ15-Q24-S12-D 24 9~36 12 0 1.25 15 100 87 PDQ15-Q24-S15-D 24 9~36 15 0 1.0 15 100 88 PDQ15-Q24-D5-D 24 9~36 ±5 0 ±1.5 15 75 85 PDQ15-Q24-D12-D 24 9~36 ±12 0 ±0.625 15 100 87 PDQ15-Q24-D15-D 24 9~36 ±15 0 ±0.500 15 100 88 PDQ15-Q48-S3-D 48 18~75 3.3 0 4.0 13.2 75 88 PDQ15-Q48-S5-D 48 18~75 5 0 3.0 15 75 88 PDQ15-Q48-S12-D 48 18~75 12 0 1.25 15 100 87 PDQ15-Q48-S15-D 48 18~75 15 0 1.0 15 100 87 PDQ15-Q48-D5-D 48 18~75 ±5 0 ±1.5 15 75 85 PDQ15-Q48-D12-D 48 18~75 ±12 0 ±0.625 15 100 87 PDQ15-Q48-D15-D 48 18~75 ±15 0 ±0.500 15 100 87 Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, with 10 µF tantalum and 1 µF ceramic capacitors on the output. 2. All specifications are measured at Ta=25°C, nominal input voltage, and rated output load unless otherwise specified. PART NUMBER KEY Base Number Packaging Style: D = DIP PDQ15 - QXX - X XX - D Output S = single D = dual Input Voltage Output Voltage For more information, please visit the product page.
cui.com date 07/12/2016 │ page 2 of 9CUI Inc │ SERIES: PDQ15-D │ DESCRIPTION: DC-DC CONVERTER INPUT parameter conditions/description min typ max units operating input voltage 24 Vdc input models
48 Vdc input models
24 Vdc input models
current 24 Vdc input models 2.1 1.0 A A under voltage shutdown
24 Vdc input models, power up
24 Vdc input models, power down
48 Vdc input models, power up
48 Vdc input models, power down
8.8 8.0 Vdc Vdc Vdc Vdc remote on/off1 turn on (3.5~75 Vdc or open circuit) turn off (<1.2 Vdc) filter LC type input reverse polarity protection no input fuse
4 A time delay fuse for 24 Vdc input models
(recommended)
2 A time delay fuse for 48 Vdc input models
(recommended) Notes: 1. CMOS or open collector TTL, reference to –Vin. OUTPUT parameter conditions/description min typ max units maximum capacitive load
3.3 Vdc output models
5 Vdc output models
12 Vdc output models
15 Vdc output models
±5 Vdc output models ±12 Vdc output models ±15 Vdc output models 4,000 3,000 1,250 1,000 1,500 625 470 μF μF μF μF μF μF μF voltage accuracy ±1.5 % line regulation from high line to low line single output models dual output models ±0.2 ±0.5 load regulation from 100% load to minimum load single output models dual output models ±0.2 ±1.0 voltage balance dual output models ±2.0 % cross regulation load cross variation 10%/100% (dual output models) ±5 % turn-on delay time, from input from Vin, min to 10% Vo 10 ms turn-on delay time, from on/off control from Von/off to 10% Vo 10 ms rise time from 10% Vo to 90% Vo 10 ms adjustability2 see application notes ±10 % switching frequency 400 kHz dynamic load response 75%-100% step load change error band (Vout) recovery time 250 µs temperature coefficient ±0.03 %/°C Note: 2. For single output models only. For more information, please visit the product page.
cui.com date 07/12/2016 │ page 3 of 9CUI Inc │ SERIES: PDQ15-D │ DESCRIPTION: DC-DC CONVERTER PROTECTIONS parameter conditions/description min typ max units over voltage protection zener or TVS clamp
5 Vdc output models (single and dual)
12 Vdc output models (single and dual)
15 Vdc output models (single and dual)
3.9 6.2 Vdc Vdc Vdc Vdc over current protection hiccup mode 110 140 160 % short circuit protection continuous, automatic recovery SAFETY AND COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute 1,500 Vdc isolation resistance input to output 1,000 MΩ isolation capacitance input to output 1,000 pF conducted emissions EN 55022 Class A (external circuit required, see Figure 3) MTBF as per MIL-HDBK-217F, GB, full load, 25°C 3.3, 5 Vdc output models all other models 950,000 1,300,000 hours hours RoHS 2011/65/EU ENVIRONMENTAL parameter conditions/description min typ max units operating temperature see derating curves -40 105 °C storage temperature -55 125 °C operating humidity non-condensing 95 % SOLDERABILITY parameter conditions/description min typ max units wave soldering see wave soldering profile 260 °C Temperature (°C) Time (Seconds) Notes: 1. Soldering materials: Sn/Cu/Ni 2. Ramp up rate during preheat: 1.4°C/s (from 50°C to 100°C) 3. Soaking temperature: 0.5°C/s (from 100°C to 130°C), 60±20 seconds 4. Peak temperature: 260°C, above 250°C for 3~6 seconds 5. Ramp down rate during cooling: -10°C/s (from 260°C to 150°C) For more information, please visit the product page.
cui.com date 07/12/2016 │ page 4 of 9CUI Inc │ SERIES: PDQ15-D │ DESCRIPTION: DC-DC CONVERTER 54 3 1.00 [25.4] 1.00 [25.4] 0.10 [2.5] 0.800 [20.32] 0.400 [10.16] 0.400 [10.16] 0.40 [10.2] 0.200 [5.08] 0.40 [10.2] 0.22 [5.6] 0.04 [1.0] min. 0.300 [7.62] Recommended PCB Layout Top View MECHANICAL DRAWING units: inches [mm] tolerance: X.XX ±0.02 [±0.5] pin diameter tolerance: ±0.004[±0.1] MECHANICAL parameter conditions/description min typ max units case material black coated copper with non-conductive base weight 18 g PIN CONNECTIONS PIN Function Single Dual 1 +Vin +Vin 2 -Vin -Vin 3 +Vout +Vout
4 Trim Common
6 Remote Remote
For more information, please visit the product page.
cui.com date 07/12/2016 │ page 5 of 9CUI Inc │ SERIES: PDQ15-D │ DESCRIPTION: DC-DC CONVERTER DERATING CURVE Ambient Temperature (°C) Load (%) -40 100 -20 02 04 06 08 0 Temperature Derating Curve (Natural Convention) 120 10568
9 Vdc
24 Vdc
36 Vdc
Load Current (%) 20 30 40 50 60 70 80 90 100 100 Efficiency (%) EFFICIENCY CURVES PDQ15-Q24-S3-D Efficiency Curve (Efficiency vs. Line Voltage and Load Current) Load Current (%) 20 30 40 50 60 70 80 90 100 100 Efficiency (%) PDQ15-Q24-D5-D Efficiency Curve (Efficiency vs. Line Voltage and Load Current) Load Current (%) 20 30 40 50 60 70 80 90 100 100 Efficiency (%) PDQ15-Q24-S12-D Efficiency Curve (Efficiency vs. Line Voltage and Load Current) Efficiency (%) Load Current (%) 20 30 40 50 60 70 80 90 100 PDQ15-Q24-S15-D Efficiency Curve (Efficiency vs. Line Voltage and Load Current) For more information, please visit the product page.
cui.com date 07/12/2016 │ page 6 of 9CUI Inc │ SERIES: PDQ15-D │ DESCRIPTION: DC-DC CONVERTER EFFICIENCY CURVES (CONTINUED)
18 Vdc
48 Vdc
75 Vdc
70Efficiency (%) Load Current (%) 20 30 40 50 60 70 80 90 100 PDQ15-Q48-S12-D Efficiency Curve (Efficiency vs. Line Voltage and Load Current) Efficiency (%) Load Current (%) 20 30 40 50 60 70 80 90 100 PDQ15-Q48-S15-D Efficiency Curve (Efficiency vs. Line Voltage and Load Current) Efficiency (%) Load Current (%) 20 30 40 50 60 70 80 90 100 PDQ15-Q24-D15-D Efficiency Curve (Efficiency vs. Line Voltage and Load Current) 70Efficiency (%) Load Current (%) 20 30 40 50 60 70 80 90 100 PDQ15-Q48-S3-D Efficiency Curve (Efficiency vs. Line Voltage and Load Current) Efficiency (%) Load Current (%) 20 30 40 50 60 70 80 90 100 PDQ15-Q48-D5-D Efficiency Curve (Efficiency vs. Line Voltage and Load Current) 90Efficiency (%) Load Current (%) 20 30 40 50 60 70 80 90 100 PDQ15-Q48-D15-D Efficiency Curve (Efficiency vs. Line Voltage and Load Current) For more information, please visit the product page.
date 07/12/2016 │ page 9 of 9CUI Inc │ SERIES: PDQ15-D │ DESCRIPTION: DC-DC CONVERTER CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com rev. description date 1.0 initial release 07/12/2016 The revision history provided is for informational purposes only and is believed to be accurate.
REVISION HISTORY
For more information, please visit the product page.