PDC500 Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - DC Continuous input range. Full power at 42-75 VDC. 36 75 VDC Derate linearly from 40 VDC to 36 VDC, 400W. Low Voltage Protection Lowest DC input voltage. 34 VDC Hold-up Time At full load over DC input range. 17 ms Input Current 48 VDC at full rated load. 14 ADC Input Protection Non-user serviceable internally located fuse. Inrush Surge Current Vin = 75 VDC, cold thermistor. TBD A PK Output Specifications (PFC500 and PDC500) PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Efficiency Full rated load, 110 VAC (PFC500)/ 48VDC (PDC500). 75 % Minimum loads PFC/PDC500-1024 0.6 PFC500-1028 0.6 Amps PFC500-1048 1.2 Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Charts Output Power 300 LFM forced air cooling required for operation. See optional fan. 500 Watts Continuous power, multiple output models. PDC500 requires derating below 42 VDC; see PDC500 input specifications. Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 V Regulation Without connection of remote sense. PFC/PDC500-1024 0.8 PFC500-1028 0.7 % PFC500-1048 1.0 Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 1m s3% max. deviation. Turn-on Delay Time required for initial output voltage stabilization. 1 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 10 ms Interface Signals and Internal Protection (PFC500 and PDC500) PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection PFC/PDC500-1024 27.0 30.7 PFC500-1028 32.0 35.0 V PFC500-1048 60.0 70.0 Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condi tion. Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset. Remote Sense Total voltage compensation for cable losses with respect to the main output. 250 mV Current Share Accuracy of shared current with up to 6 parallel units. 10 % Inhibit TTL compatible logic signal will inhibit outputs by the application of a logic low signal. An open circuit or external TTL high signal allows normal operation. Input Power TTL compatible logic signal. Time before regulation dropout due to 4m sFail Warning loss of input power at 110 VAC. Power Good TTL compatible signal. Signal is low if main output is greater PFC/PDC500-1024 22.08 27.36 or less than 10% of nominal. For models without the PFC500-1028 25.20 30.80 V “D” option, internal pull-up resistor is 1k/H9024/H11022 For “D” option, PFC500-1048 44.20 54.72 pull-up resistor is 475/H9024. See Apps Note #P1 for details. Fan Voltage Provides 170mA current to user supplied fan if fan option is not selected. 12 V PFC500/PDC500 Series Data Sheet AUG 01, 2003 revised to JUL 13, 2006 Page 2 of 4 www.power-one.com
Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL1950. UL 60950 / CSA60950-00 (cULus Mark) ApprovedEN60950 (TÜV). PDC500 (Pending). Dielectric Withstand Meets reinforced insulation of IEC60950. Electromagnetic Interference FCC CFR title 47 Part 15 Sub-Part B - Conducted. B ClassEN55022 / CISPR 22 Conducted. B ESD Susceptibility Per EN61000-4-2, level 4. 8 kV Radiated Susceptibility Per EN61000-4-3, level 3. 10 V/M EFT/Burst (PFC500) Per EN61000-4-4, level 4. ±4 kV EFT/Burst (PDC500) Per EN61000-4-4, level 4. TBD kV Input Transient Protection PFC500 Per EN61000-4-5 class 3. PDC500 (class 2) Line to Line (PFC500) 1 Line to Ground (PFC500) 2 kVLine to Line (PDC500) 0.5 Line to Ground (PDC500) 0.5 Insulation Resistance Input to output. 10 M /H9024 Leakage Current (PFC500) Per EN60950, 264 VAC. 2.0 mA Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating. 10k ASL Ft. Non-Operating. 40k ASL Ft. Operating Temperature At 100% load 0 50 °C Derate linearly above 50°C by 2.5% per °C. At 50% load 0 70 °C Storage Temperature -55 85 °C Forced Air Cooling Forced air cooling of 300 LFM (400 LFM for PDC500) is required if the internal fan is not specified Cooling air velocity is measured at the output exiting window (2.5” x 5”). Airflow direction is from the input section to the output section. Temperature Coefficient 0°C to 70°C (after 15 minute warm-up). ±0.02 ±0.05 %/°C Relative Humidity Non-Condensing. 5 95 %RH Shock Operating: 10±3mSec, 3 axis, Half Sine. 20 G Non-operating: 10±3mSec, 3 axis, Half Sine. 40 Vibration Operating: 5-32Hz 0.02 in (DA) 32-2000Hz Sinusoidal 1 G PK Non-operating: 6.15 G RMS Options DESCRIPTION NOTES SIZE IMPACT Isolation Diodes Add “D” as a suffix to the model number to order factory installed isolation diodes N/Afor parallel or redundant operation. For 24V models with the “D” option, external caps are required to meet the 1% noise/ripple spec. Power Good has a pull-up resistor of 475/H9024 on the 24V models. See Application Note #P1 for details. Fan Add “F” as a suffix to the model number to order integral fan. 10.50" x 5.00" x 2.50" Fan provides the required 300 LFM (400 LFM for PDC500) of forced air cooling, (266.7mm x 127.0mm x 63.5mm) or otherwise provided by the end user. Metric Mounting Add “M” as a suffix to the model number to order chassis with N/AM4 x 0.7 mounting inserts. PFC500/PDC500 Series Data Sheet AUG 01, 2003 revised to JUL 13, 2006 Page 3 of 4 www.power-one.com
Overall Length With Fan: 10.50" (266.7mm) Weight: 4.3 lb (1.95 kg) Input and Output Connections: 6-32 Screw Terminal on 0.375" (9.5mm) centers Chassis: 0.090" (2.3mm) Aluminum Alloy, With Clear Finish DC+ or DC- or SUGGESTED AIRFLOW * * Airflow should be measured at the exiting window (5” x 2.5”). PFC500/PDC500 Series Data Sheet AUG 01, 2003 revised to JUL 13, 2006 Page 4 of 4 www.power-one.com NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. Specifications are subject to change without notice.