PDBFS204 COOPER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

UL Listed, IP-20 Enclosed Power Distribution Block Offer High SCCR New 2005 NEC® and UL508A SCCR marking requirements state that the following equipment must be marked with an assembly SCCR:

  • Industrial Control Panels [409.110]
  • Industrial Machinery Electrical Panels [670.3(A)]
  • Certain HVAC Equipment [440.4(B)] This SCCR is based on the lowest-rated component, or weakest link, in the assembly. Unmarked power distribution blocks will default to a rating of 10kA. The new Cooper Bussmann ® enclosed Series PDBFS offers both high SCCR and enhanced shock protection.
  • UL Listing Meets Requirements Eliminating Investigation and Procedures Listed to UL1953 for minimum spacing requirements of at least 1˝ through air and 2˝ over surface as required for UL508A industrial control panel feeder applications. See back page.
  • High SCCR Up to 200kA rating enables the power distribution block to be one of the highest rated devices in the panel. This helps achieve a high assembly SCCR.
  • Enclosed for Enhanced Electrical Safety Safer work conditions. IP-20 finger-safe under specific conditions.
  • Easy Panel Mounting Gangable for flexible multi-pole installations, plus small footprint for tight spacing.
  • Simple and Fast Installation DIN rail mount or panel mount, (See datasheet 1049). Captive terminal screws are backed out at the factory.
  • Meet Wireway Requirements Series PDBFS can be used to meet the new 2005 NEC® 376.56(B) requirement. Maximize Short-Circuit Current Rating While Improving Safety Power Distribution Block

©2007 Cooper Bussmann • St. Louis, MO 63178 636-394-2877 • www.cooperbussmann.com Printed in USA Reorder # 3137 1-07-5M Cooper Bussmann UL Listed PDBs With High SCCRs Feature/Benefits

  • UL Listed 1953. File E256146
  • CSA Certified, Class 6228-01, File 15364
  • 600Vac or dc (UL1953), 690Vac or dc (IEC)
  • SCCR up to 200,000kA, see table for details
  • Single pole, gang for multiple pole applications with accessory part 2A1279 interlocking dovetail
  • Datasheet #1049 located at www.cooperbussmann.com Terminal Copper Conductor Capability Short-Circuit Current Rating Data Line Load Configuration Conductors Max Fuse Class & Amp** Catalog Number Openings per Pole Line Load J T RK1 RK5 (All Single Amps Wire Range Wire Range AWG or AWG or LPJ JJS LPS-RK FRS-R SCCR Pole) Line Load kcmil kcmil JJN LPN-RK FRN-R PDBFS204 175A 2/0 - 8 AWG 2/0 - 8 AWG 2/0 - 8 2/0 - 8 200 200 100 60 200kA70 - 10 mm2 70 - 10 mm2 2/0 - 8 AWG 4 - 14 AWG 4 - 12 200 200 100 † 60† 200kA PDBFS220 175A 70 - 10 mm2 25 - 2.5 mm2 2/0 - 8 4 - 14 175† 175† 100† 60† 100kA 200† 200† 100† 60† 50kA 350kcmil - 6 AWG 350kcmil - 6 AWG PDBFS303 310A 150 - 16 mm2 150 - 16 mm2 350 - 6 350 - 6 400 400 200 100 200kA 500kcmil - 6 AWG 2 - 14 AWG 2 - 6 400 400 200 † 100† 200kA PDBFS330 380A 240 - 16 mm2 35 - 2.5 mm2 500 - 6 2 - 14 200† 200† 100† 30† 50kA 175† 175† 100† 30† 100kA 300kcmil - 4 AWG 4 - 14 AWG 300 4 - 8 600 600 400 † 200† 200kA PDBFS377 570A 150 - 12 mm2 25 - 2.5 mm2 300 - 4 4 600 † 600† 400† 200† 50kA 4 - 14 200 † 200† 100† 30† 50kA PDBFS500 620A 350kcmil - 4 AWG 350kcmil - 4 AWG 350 350 600 600 400 200 200kA 185 - 12 mm2 185 - 12 mm2 350 - 4 350 - 4 600 800 600 200 100kA 500kcmil - 6 AWG 500kcmil - 6 AWG 500 500 600 800* 600 400 200kA PDBFS504 760A 240 - 16 mm2 240 - 16 mm2 600 800* 600 600 100kA 500 - 6 500 - 6 600 600 400 200 100kA Ampacities 75C per NEC® Table 310.16 and UL508A Table 28.1 *Class L 800A (KRP-C 800_SP) or less fuses suitable for this particular SCCR case. ** Class G 60A (SC-60) or less or Class CC 30A (LP-CC-30, FNQ-R-30, KTK-R-30) or less are suitable for all these SCCRs in this ta ble. †Higher SCCR may be available, check latest datasheet 1049. Series PDBFS Dimensions inches (mm) Part No. Width (A) Length (B) Height (C) UL Listed 1953 vs. UL Recognized 1059 Listed products require simply checking to ensure that the product is used in accordance with its listing and labeling. However, for recognized products, such as power terminal blocks, the “Conditions of Acceptability” must be investigated to ensure the product is suitable for the specific application, and then the procedure description must be documented in the manufacturer’s procedure for the assembly . For additional information see Datasheet #1049 located at www.cooperbussmann.com/products/datasheet.asp H A B