INTELLIGENT POWER DISTRIBUTION SYSTEMS CP Power-D-Box ® for ControlPlex® Rack CP Power-D-Box ® The Power-D-Box ® CP is a modular power distribution system. Depending on the respective application, the compact 2 HU en- closure can accommodate these system components: ESX300- S, RSI10, RCI11 oder EAI300. User friendliness is of top priority in the event of a system extension with the system live without cau- sing dow ntim es. All sub-assem blies are hot-sw appable w ithout af- fecting neighbouring components. Depending on the application, term ination can be placed both on the front or on the rear. M ajor application areas of the ControlPlex® Rack system are com m u- nication technology equipment both in the negative (DC -48 V or DC -60 V) and in the positive voltage range (DC 24 V, 48 V, 60 V). INTELLIGENT POWER DISTRIBUTION SYSTEMS CP Power-D-Box ® for ControlPlex® Rack TYPICAL FEATURES YOUR BENEFITS
- 19" power distribution system, made of aluminium
- Compact design, protected against brush contact (2RU)
- Designed for plug-in type circuit protectors (ESX300-S)
- Slot for signalling module (RSI10) or control interface module (RCI11)
- Various preferred types w ith front side or rear side load outputs
- Easy system extension without shutdown thanks to plug-in type circuit protectors (ESX300-S).
- M axim um system protection through electronic current lim itation and load disconnection
- M axim um system availability through selective protection
- System stability in the event of a short circuit through avoidance of voltage dips
- More favourable design of the equipment power supplies thanks to the electronic circuit protectors PREFERRED TYPES Preferred types are E-T-A products, w hich are m ost frequently used by our custom ers. W e m anufacture these preferred types in substantial quantities. You can /f_ind an overview of our preferred types here (Page 3 ). TYPICAL APPLICATIONS COMPLIANCE Telecommunications and datacom, energy providers, industrial swit- ching and control systems, rail engineering, infrastructure WEB LINKS Further information, Mounting instructions (CP minus), Mounting in- structions (CP plus), REACH , RoHS , Contact global.e-t-a.com 1225
INTELLIGENT POWER DISTRIBUTION SYSTEMS CP Power-D-Box ® for ControlPlex® Rack GENERAL INFORMATION FURTHER INFORMATION Mounting instructions for the Power-D-Box ® CP minus voltage range https://www.e-t-a.com/datei/13849 Mounting instructions for the Power-D-Box ® CP plus voltage range https://www.e-t-a.com/datei/13850 TECHNICAL DATA (T u = +25 °C, Ub = DC -48 V) ELECTRICAL DATA Rated voltage range Minus: DC -38...-72 V Plus: DC 18...72 V Total current 2x150 A with redundant design and supply terminal at the back
200 A with non-redundant design and double supply terminal at the back
100 A for non-redundant design
Mounting dimensions (WxHxD) W idth: 482.6 m m (19" m ounting) x H eight: 89 m m (2H U ) x Installation depth: 205 m m (supply from the back) / Installation depth: 175 m m (front-side line entry) Mass Approx. 2.5 kg Material Aluminium Enclosure grounding M6 studs, always on the rear SUPPLY Terminals / Cable cross section Terminal at the back: Screw term inals, cable cross section, 16...50 m m 2 Terminal at the back: Screw term inals, cable cross section, 4...25 m m 2 LOADS Terminals / Cable cross section Terminals at the back: Plug-in type 2-pole screw term inals w ith m ating connector, cable cross section 0.5...6 m m 2 Term inals on the front: Plug-in type 3 -pole high current SU B-D socket, cable cross section 2.5… 10 m m 2, mating connec- tor (not included in the delivery scope), see accessories AMBIENT CONDITIONS Ambient temperature -20...+60 °C (without condensation) Damp heat Test according to IEC 60068-2-78, 3K6 climate class according to EN 60721 96 hours at 95 % relative humidity, 40 °C Vibration Test according to IEC 60068-2-6, test Fc 3 g IP code (standard) IP20 (power distribution modules protected against brush contact) EMC requirements (EMC directive, CE logo) emitted interference EN 61000-6-3 EMC requirements (EMC directive, CE logo) resistance to disturbances EN 61000-6-2 global.e-t-a.com 1225
INTELLIGENT POWER DISTRIBUTION SYSTEMS CP Power-D-Box ® for ControlPlex® Rack ORDERING NUMBER CODE P D B N C P R R R A
1 TYPE NUMBER
PDB Power-D-Box ® 19“ (condition as delivered), with ETSI reversible flange – 19“
2 PROTECTED POLE
CP ControlPlex® Rack
4 LOAD CHANNELS
xx Number of load channels (total)
5 REDUNDANCY
R Redundant design (two supply entries, with main and load terminals on the back)
6 MAIN TERMINALS
7 LOAD TERMINALS
8 VERSION
9 REVISION
2 Revision 2
Looking for a customer-specific version you cannot /f_ind in our ordering number code? Please get in touch with us. C ircuit protectors are not included in the delivery scope. PREFERRED TYPES Preferred types Short description Supply current [A] Minus version DC -48 V or DC -60 V - PDB-N-CP09A-RR- A2 Load current max. 30A with 9 load channels 150 PDB-N-CP09A-FF-A2 Load current max. 30A with 9 load channels 100 PDB-N-CP09A-RF-A2 Load current max. 30A with 9 load channels 150 PDB-N-CP19A-RR-A2 Load current max. 30A with 19 load channels 200 PDB-N-CP18R-RR-A2 Load current max. 30A with 2 x 9 load channels 2 x 150 Plus version DC 24 V, 48 V, 60 V - PDB-P-CP09A-RR-A2 Load current max. 30A with 9 load channels 150 global.e-t-a.com 1225
INTELLIGENT POWER DISTRIBUTION SYSTEMS CP Power-D-Box ® for ControlPlex® Rack PDB-P-CP09A-FF-A2 Load current max. 30A with 9 load channels 100 PDB-P-CP09A-RF-A2 Load current max. 30A with 9 load channels 150 PDB-P-CP19A-RR-A2 Load current max. 30A with 19 load channels 200 PDB-P-CP18R-RR-A2 Load current max. 30A with 2 x 9 load channels 2 x 150 COMPLIANCE CE according to EMC directive (combined with ESX300-S plus / with ESX300-S minus) Compliance accord- ing to EN60950-1 / UL60950-1 DIMENSIONS DIMENSIONAL DRAWING - FRONT CONNECTION (PDB-N-CP 09A-FF-X) global.e-t-a.com 1225
INTELLIGENT POWER DISTRIBUTION SYSTEMS CP Power-D-Box ® for ControlPlex® Rack DIMENSIONAL DRAWING - CONNECTION ON THE BACK (PDB-N-CP XXY-RR-X) SCHEMATIC DIAGRAMS SCHEMATIC DIAGRAM – REDUNDANT DESIGN – EXAMPLE: MINUS-POLE PROTECTED global.e-t-a.com 1225
INTELLIGENT POWER DISTRIBUTION SYSTEMS CP Power-D-Box ® for ControlPlex® Rack SCHEMATIC DIAGRAM - NON-REDUNDANT DESIGN – EXAMPLE: MINUS-POLE PROTECTED TERMINALS LOAD TERMINALS Preferred types Load terminals Supply cable Minus version Terminal [mm 2] Max. current load [A] At the back [Nm] At the front Terminal 50 mm 2 150 A Front-side terminal 25 mm 2 100 A PDB-N-CP09A-RF-A2 10 30 - Crimp terminal6...8 - PDB-N-CP09A-FF-A2 10 30 - Crimp terminal- 4...4.5 Nm 6...8 Nm (dou- ble supply ter- minal, max. 200 A) 6...8 Nm (dou- ble supply ter- minal, max. 200 A) Plus version Terminal [mm 2] Max. current load [A] At the back [Nm] At the front Terminal 50 mm 2 150 A Front-side terminal 25 mm 2 100 A PDB-P-CP09A-RF-A2 10 30 - Crimp terminal6...8 - PDB-P-CP09A-FF-A2 10 30 - Crimp terminal- 4...4.5 Nm 6... 8 (double supply termi- nal, max. 200 6... 8 (double supply termi- nal, max. 200 G round studs M 6 / 6 Nm global.e-t-a.com 1225
INTELLIGENT POWER DISTRIBUTION SYSTEMS CP Power-D-Box ® for ControlPlex® Rack ACCESSORIES REQUIRED ACCESSORIES ESX300-S minus The hot pluggable ESX300-S minus electronic circuit protector ensures re- liable overcurrent protection by means of electronic current limitation and load disconnection. It reliably prevents the destruction of electronic sub-as- semblies or load lines in power supply systems in a voltage range of DC -48 V and DC -60 V. Thanks to a selective load disconnection, a voltage dip is prevented in the event of a failure and other faultless devices in the circuit re- main working. The integral bus interface can transmit the recorded measuring values and status messages to the RCI11 control interface, where they can be used to automatically trigger actions or for data collection and monitoring. /uni00A0/uni00A0/uni00A0↳ X22387411 Tw o ESX3 00-S connected in parallel Consisting of: 1 front bridge 1 load output bridge /uni00A0/uni00A0/uni00A0↳ X22387401 Three ESX3 00-S connected in parallel Consisting of: 1 front bridge 1 load output bridge /uni00A0/uni00A0/uni00A0↳ X22385301 ESX300-S removing bracket Consisting of: 1 removing bracket 1 mounting bracket ESX300-S plus The hot pluggable ESX300-S plus electronic circuit protector ensures reliable overcurrent protection by means of electronic current limitation and load dis- connection. It reliably prevents the destruction of electronic sub-assem blies or load lines in pow er supply system s in DC +24 V, DC +48 V and DC +60 V voltage ranges. Thanks to its selective load disconnection, a voltage dip is prevented in the event of a failure and fault-free devices can be further ope- rated. The integral bus interface can transmit the recorded measuring values and status messages to the RCI11 control interface, where they can be used to automatically trigger actions or for data collection and monitoring. /uni00A0/uni00A0/uni00A0↳ X22387411 Tw o ESX3 00-S connected in parallel Consisting of: 1 front bridge 1 load output bridge /uni00A0/uni00A0/uni00A0↳ X22387401 Three ESX3 00-S connected in parallel Consisting of: 1 front bridge 1 load output bridge /uni00A0/uni00A0/uni00A0↳ X22385301 ESX300-S removing bracket Consisting of: 1 removing bracket 1 mounting bracket OPTIONAL ACCESSORIES RCI11 The RCI11 Remote Control Interface allows remote control and monitoring of the system and its connected loads, reducing maintenance costs and provi- ding maximum transparency. It helps integrate the ControlPlex® Rack sys- tem into the network surroundings and into the centralised corporate ma- nagement system. The RCI11 provides access to all installed ESX300-S cir- cuit protectors via the internal bus system and can enquire or store individual measuring data, status conditions and fault indications and forward them to the superordinate control unit or execute com m ands from the control unit for controlling purposes. The RCI11 Remote Control Interface can be extended during operation “Hot Plug & Play“. RSI10 The RSI10 Remote Signalling Interface ensures reliable and early detection of critical system conditions. It can communicate with all circuit protectors in- stalled in the ControlPlex® Rack via internal BUS connection. When one of the circuit protectors is disconnected from the related load due to an over- current etc., the RSI10 w ill externally indicate this status via a potential-free group signal, e.g. to a m onitoring system . It is the perfect w ay to m inim ise downtimes and reduce operational and maintenance costs. global.e-t-a.com 1225
INTELLIGENT POWER DISTRIBUTION SYSTEMS CP Power-D-Box ® for ControlPlex® Rack EAI300 Combined with the RCI11, the EAI300 External Alarm Interface allows record- ing of external sensor data and alarm signalling in the management system. It includes e.g. additional monitoring and indication of door contacts or tempe- rature sensors in the technical room . This provides high system transparency and fast intervention in the event of alarms. Thanks to programmable logical links, operating conditions of the ESX300-S can be linked to external encoder signals that enable automatic switching operations. Instead of the ESX300-S electronic circuit protector, the EAI300 can be easily plugged into an empty slot of the ControlPlex® Rack system without shutting down the connected loads. This allows connection of external signalling devices in the control ca- binets without requiring additional space. X22326011 Cable strain relief Consisting of: 2 mounting brackets 1 rod 6 screw s 1 insulating tube X22318901 Load-SU B-D connector (suitable for front connection) including:
- Enclosure
- 3 contacts X22357601 1U marking band with cable gland Consisting of: 1 - 1 HU stainless steel marking band with marking strips and cable duct 2 - Screw s w ith w ashers 24 - Plastic marking labels X22357501 Marking strip 0.5 HU Consisting of: 1 - 0.5 HU stainless steel marking strip with marking labels 2 - Screw s w ith w ashers 24 - Plastic marking labels FURTHER INFORMATION ABOUT ACCESSORIES (DRAWINGS) ACCESSORIES ACCESSORIES global.e-t-a.com 1225
INTELLIGENT POWER DISTRIBUTION SYSTEMS CP Power-D-Box ® for ControlPlex® Rack ACCESSORIES All information and data given on our products are accurate and reliable to the best of our knowledge, but E-T-A does not accept any responsibility for the use in applications which are not in accordance with the present specification. E-T-A reserves the right to change specifications at any time in the interest of technical improvement. Dimensions are subject to change without notice. Please enquire for the latest dimensional drawing with tolerances if required. All dimensions, data, pictures and descriptions are for information only and are not binding. Amendments, errors and omissions excepted. Ordering part numbers may differ from the device marking. global.e-t-a.com 1225