www.e-t-a.de ControlPlex® Rack 1623 Description – Power-D-Box® The ControlPlex® Rack is an intelligent and remotely controlla- ble 2U power distribution system made of aluminium in a closed housing, protected against brush contact featuring an extremely compact design. The system has been especially designed for the selective protection of systems with minus supply (DC -48 V or DC -60 V) which are widely used in communication engineering. In order to avoid voltage dips of switch-mode power supplies in the event of overload or short circuit, protection is effected by means of intelligent, short-circuit current limited electronic circuit protectors. The plug-in type terminal design of the loads and the design allowing extension in operation help to significantly reduce installation and maintenance time. Order number PDB Power-D-Box® 19" (supplied standard), with ETSI reversible flange – 19" Protected pole N Negative pole protected Module CP ControlPlex-Rack xx Number of load channels (total) A non-redundant design R redundant design (two supply entries, with main and load terminals on the rear) Main terminals R on the rear F on the front load terminals R on the rear F on the front Version A BUS PDB - N - CP 18 R- R R - A ordering example Benefits l Designed for plug-in type electronic circuit protectors type ESX300-S with short-circuit limitation and extended status indication, expandable in operation. Current per load channel 2 A...24 A l Extremely compact installation depth 175 mm with terminals on the front and 205 mm with rear-side terminals l With slot for signalling or control interface sub-assembly l Use of industrially manufactured power distribution modules – protected against brush contact l Supplied with blind covers l Other versions available on request, e.g. with back-up fuses, various terminal connectors and cross sections, customised marking etc. ControlPlex ® Rack: PDB –N– CP 09 A–RR-A: Supply current max. 150 A Load current max. 30 A with 9 load channels PDB –N– CP 09 A–FF-A: Supply current max. 100 A Load current max. 30 A with 9 load channels PDB –N– CP 09 A–RF-A: Supply current max. 150 A, Load current max. 30 A with 9 load channels PDB –N– CP 19 A–RR-A: Supply current max. 200 A Load current max. 30 A with 19 load channels PDB –N– CP 18 R–RR-A: Supply current max. 2 x 150 A Load current max. 30 A with 2 x 9 load channels Preferred types Technical data (Tamb = 25 °C, UB = DC -48 V) Application: Modular power distribution system for short circuit current limited DC -48 V / DC -60 V applications 19" Power-D-Box ® Length: 84 HP (462.72 mm) Height: 2U (88.90 mm) Material: aluminium Plug-in type circuit protectors ESX300-S – 300 – xx A (with ELBus ® interface) Plug-in type group signalling interface Plug-in type control interface RSI10-xxx-A or RCI10-xxx-A Rated voltage DC -48 V…-60 V Total current - 2x150 A with redundant design and line entry on the rear - 200 A with non-redundant design and double line entry on the rear - 100 A with non-redundant design and line entry on the front Ambient temperature -20 °C to +60 °C (without condensation) Supply terminals Terminal on the rear: screw terminals, cable cross section 16 mm²...50 mm² Terminals on the front: screw terminals, cable cross section 4 mm²...25 mm² Load terminals Terminal on the rear: plug-in type 2-pole screw terminals with mating connector, cable cross section 0.5 mm²...6 mm² Terminals on the front: plug-in type 3-pole high current SUB-D connector, cable cross section 2.5 mm²...10 mm², mating connector (not supplied with product): see accessories Ground terminal M6 studs, always on the rear Humidity 96 hours at 95% RH, 40 °C, to IEC 60068-2-78, climate class 3K3 to EN60721 EMC EN 61000-6-2 / EN 61000-6-3 Vibration 3 g to IEC 60068-2-6, Mass approx. 2.5 kg Conformity CE, EN60950-1

www.e-t-a.de ControlPlex® Rack 1623 Schematic diagram – non-redundant design Schematic diagram – redundant design A1- A1- A2- A3- A4- A5- A6- A7- A8- A9- A10- A11- A12- A13- A14- A15- A16- A17- A18- A19- -X3 -X3 -X3- X3 -X3 -X3 -X3 -X3 -X3 -X3 -X3 -X3 -X3 -X3 -X3 -X3 -X3 -X3 -X3 A1+ A- A+ signalling A (optional) A2-A 2+ A3-A 3+ A4-A 4+ A5- load outputs A supply A non-redundant design A5+A 6- A6+A 7- A7+A 8- A8+A 9- A9+A 10- A10+ A12- A12+ A13- A13+ A14- A14+ A15- A15+ A16- A16+ A17- A17+ A18- A18+ A19- A19+A11- A11+ 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 1

2 LOAD-

SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK 12 14 21 21 42 12 14 21 21 42 12 14 21 21 42 12 14 21 21 42 12 14 21 21 42 12 14 21 21 42 12 14 21 21 42 12 14 21 21 42 12 14 21 21 42 12 14 -X2 -X1 1 2 LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LOAD- SI SISI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI LOAD- SI SI A1- A1- A2- A3- A4- A5- A6- A7- A8- A9- B1- B2- B3- B4- B5- B6- B7- B8- B9- -X3 A1+ A- A+ signalling A (optional) signalling B (optional) A2-A 2+ A3-A 3+ A4-A 4+ A5- load outputs A supply A redundant design supply B load outputs B A5+A 6- A6+A 7- A7+A 8- A8+A 9- A9+B 1- -X6 B1+ B- B+ B2-B 2+ B3-B 3+ B4-B 4+ B5-B 5+ B6-B 6+ B7-B 7+ B8-B 8+ B9-B 9+ 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 LOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- ESX300-S E-T-A SILOAD- SILINE- FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOKFAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK FAULTOK SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- SILINE- ESX300-S E-T-A 12 14 21 21 42 12 14 21 21 42 12 14 21 21 42 12 14 21 21 42 12 14 21 21 42 12 14 21 21 42 12 14 21 21 42 12 14 21 21 42 12 14 21 21 4 -X2 -X1 1 2 1 2 1-X5 -X4 LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+ LINE- GND+

www.e-t-a.de ControlPlex® Rack 1623 ControlPlex® Rack Dimensions – connection from the front (PDB-N-CP 09A-FF-x) Dimensions – connection from the rear (PDB-N-CP xxy-RR-x) 16046 171.5 271.5 cable grip set (optional) cable grip set (optional) cable guide loads cable guide supply 515 (ETS) 465 (19“) 1:2 76.2 (19“) 75 (ETS) 88.9 (2U) 515 (ETS) 465 (19") 76.2 (19“) 531.4 (ETS) 450 171.5 16014 201.5 271.5 cable grip set (optional) cable grip set (optional) cable grip set (optional) cable guide supply 482.6 (19") 75 (ETS) 88.9 (2U)

www.e-t-a.de ControlPlex® Rack 1623 All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effective- ness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. Accessories Cable grip (mounted when supplied) X 223 260 11 Consisting of: 2 mounting brackets 1 rod 6 screws 1 insulating tube Marking band 0.5U X 223 575 01 Consisting of: 1 0.5U stainless steel marking band with marking strips 2 screws with washers 24 moulded labels 1U marking band with cable gland X 223 576 01 Consisting of: 1 1U stainless steel marking band with marking strips and cable gland 4 screws with washers 24 moulded labels Load SUB-D connector (suitable for front connection) X 223 189 01 Consisting of: - enclosure - 3 contacts load terminals Supply cable terminal type max. current load on the rear on the front terminal 50 mm 2 150 A front terminal 25 mm² 100A PDB - N - CP09A - RR-x 6 mm² 30 A 0.5…0.8 Nm 6…8 Nm PDB - N - CP09A - RF-x 10 mm² 30 A crimp terminal 6…8 Nm PDB - N - CP09A - FF-x 10 mm² 30 A crimp terminal 4…4.5 Nm PDB - N - CP19A - RR-x 6 mm² 30 A 0.5…0.8 Nm 6…8 Nm (double supply terminal, max. 200 A) PDB - N - CP18R - RR-x 6 mm² 30 A 0.5…0.8 Nm 6…8 Nm (double supply terminal, 2 x 150 A) Ground studs M6 / 6 Nm

www.e-t-a.de ESX300S for ControlPlex® Rack 1623 ControlPlex® Rack Description – ESX300S Technical data (Tamb = 25 °C, UB = DC -48 V) The electronic circuit protector ESX300-S has been designed for protection and monitoring systems in telecommunications. Focus application of this device is the minus switching of loads widely used in telecommunications in power supply systems with rated voltage DC -48 V and DC -60 V. The additionally available overcurrent protection, realised by means of electronic current limitation and electronic disconnection, reliably prevents the destruction of electronic sub-assemblies or load lines by overload or short circuit. In addition, the electronic current limitation helps to prevent high currents flowing in the event of a short circuit, which could cause undesired voltage dips and lead to system crashes. Major applications are power distribution systems in telecommuni- cations engineering. The electronic circuit protectors type ESX300-S are fitted into 19" or ETSI racks and are available in various current ratings from 2 A to 24 A. Benefits l Availability on the highest level due to the reduction of the failure probability l Increasing the reliability of the systems (selectivity) l Hazard reduction by active and remotely controlled disconnection of equipment, triggered by warning messages such as fire and/ or water (optional) l Decreasing fire hazard by selective disconnection l Reliable disconnection even with long cable lengths l Reduced maintenance because of remotely controllable power reset – no maintenance on site required l Integral fail-safe-element l Status indication by LEDs l BUS-interface (optional) Order number Operating data Operating voltage DC -48 V and DC -60 V (-37...-72 V) Current rating range IN 2 A / 5 A / 8 A / 12 A / 16 A / 20 A / 24 A Power consumption I0 typically 16 mA Trip current typically 1.2 x IN Low voltage monitoring factory setting: type DC -36 V Excess voltage monitoring factory setting: type DC -73 V Load circuit Load output power MOSFET switching output (minus switching), no physical isolation Mounting position vertical Cooling convection cooling Trip times typically <20 ms at short circuit typically <30 sec. at overcurrent Temperature disconnection typically at T amb = 105 °C Inductive load external free wheeling diode recom- mended Capacitive load max. 7.000µF see table 2 Auxiliary circuit (option) Contact potential-free contact, break contact Max. switching voltage DC 72 V Max. switching current 1 A Rupture capacity 60 W / 62.5 VA Control interface (option) Interface type ESX300-S ELBus® interface General data Ambient temperature -20 °C...+60 °C without condensation see EN50240-1 Storage temperature -20 °C...+70 °C Back-up fuse not required due to integral fail-safe element. Leakage current in the off state typically 1 mA Terminals blade terminals DIN 46244-A 6.3-0.8 and 2.8- 0.5 Style rack without enclosure Degree of protection IP00 DIN 40050 EMC requirements to EN 61000-6-3 & EN 61000-6-2 ESD 4 kV/air 8 kV Humidity 96 hours at 95% RH, 40 °C, to IEC 60068-2-78, climate class 3K3 to EN60721 Vibration 3 g to IEC 60068-2-6, Approvals CE logo to EN 61000-6-3 & EN 61000-6-2 and UL 2367 Mass typically 50 g Type ESX300 Electronic circuit protector Version S Standard, pluggable (front plate, without housing) Interfaces

1 Signalling potential-free change-over contact just for

3 ELBus

® interface Voltage range

0 DC Minus 37 V – 72 V

0 Without additional functions

www.e-t-a.de ESX300S for ControlPlex® Rack 1623 Table 2: Current rating, voltage drop, load capacity Table 1: LED status indication current rating range IN typical voltage drop UON at IN active current limitation typically trip time typ. at 1,2 x IN fail-safe element max. load cur- rent at 100 % ON duty max. capacitive load (µF) TAMB = 40 °C 2 A 130 mV 1.20 x IN 0.2 – 3 s 4 A 2 A 1500 5 A 130 mV 1.20 x IN 0.2 – 3 s 10 A 5 A 2000 8 A 200 mV 1.20 x IN 0.2 – 3 s 10 A 8 A 3000 12 A 150 mV 1.20 x IN 0.2 – 3 s 20 A 12 A 4000 16 A 200 mV 1.20 x IN 0.2 – 3 s 20 A 16 A 5000 20 A 160 mV 1.20 x IN 0.2 – 3 s 30 A 20 A 6000 24 A 200 mV 1.20 x IN 0.2 – 3 s 30 A 24 A 7000 Note: The total current of neighbouring devices must not exceed 44 A. The derating factor at an ambient temperature of > 40 °C is 0.8 times rated current. operating state load output LED green LED red auxiliary contact N/C (optional) No error -> OFF locked flashing slowly OFF open Normal operation connected ON OFF open Error undervoltage with device in OFF condition (15 V < U < 37 V) locked OFF ON closed Error overvoltage with device in OFF condition (73 V > U < 75 V) locked OFF ON closed Overcurrent error detected (I > I N < 1.2 x IN) overcurrent failure has to be detected for approx. 30 sec before disconnection is effected connected ON flashing fast open Error - overcurrent or short circuit disconnection locked OFF ON closed Error undervoltage (U > 15 V < 37 V) connected ON ON closed Error overvoltage (72 V > U < 73 V) connected ON ON closed Error, no voltage or internal error locked

1 OFF OFF closed

Error high temperature locked1 OFF flashing slowly closed Remote disconnection (ordering Status indication via l Status LEDs (red/green): l ELBus® interface (optional) l Potential-free signal contacts (optional) 1 cannot be switched on

www.e-t-a.de ESX300S for ControlPlex® Rack 1623 ESX300S for ControlPlex® Rack 105 18.9 111.8 67.7 38.75 7.57.5 11.9 14.5 11114122 98.8 104.2 BUS LOAD (-) Minus (-) LINEPlus (+) ON / OFF FAULT (red) OK (green) Bus / Si electronic control system Fuse Fail-Save RSENSE 1L INE (–) 11 + LOAD (–) Si / address Si / Bus Ik time in seconds 1000 s 100 s 10 s 1 s 0,00 s 0,1 s 0,01 s 1,00 1,10 1,20 1,30 1,40 1,50 Dimensions Schematic diagram Connection diagram (pin assignment)Time/current characteristics l The electronic current limitation typically begins in at 1.2 x IN. This means: under all overload conditions (independent of power supply and load circuit resistance) typically 1.2 times rated cur- rent is applied until disconnection. The trip time varies between 10 ms and 30 s depending on the multiple of the current rating. l Without the current limitation getting into effect at typically 1.2 x I N there would be a much higher overcurrent in the event of an overload or short circuit.

www.e-t-a.de Remote Signalling Interface RSI10 ControlPlex® Rack 1623 Description – Remote Signalling Interface Typical applications of the Remote Signalling Interface RSI10 include the potential-free signalling of alarms of the ESX300-S electronic circuit pro- tectors with bus interface used in the ControlPlex ® Rack system (type: ESX300-S-3xx). The competitive edge of this sub-assembly is its compatibility for future system extensions with the remote control and monitoring module RCI10. When using the RSI10 sub-assembly, the electronic circuit protectors do no longer have to be replaced in the event of a possible system exten- sion when operating the ControlPlex ® Rack with group signalling. Other advantages include an additional visual failure indication by means of the integral tricoloured LED and the well-known plug-and-play capability. Major applications are in centralised control units of decentralised systems, e.g. in telecommunications engineering. The RSI10 Remote Signalling Interface can be extended in operation in 19” racks or ETSI racks (hot plug-and-play). Order number RSI Remote Signalling Interface

10 Standard, steckbar (Frontplatte, ohne Gehäuse)

Interfaces (intern) 0 mit EL-BUS Schnittstelle (Standard) Voltage range (supply)

0 DC 20 V – DC 72 V

Interfaces (external) 0 potentialfreier Gruppensignalanschluss Anschlusstechnik A 2 x 3 polig, Schraubklemmen steckbar Benefits l Installation in ControlPlex® Rack without system downtimes (hot plug & play) l Complete compatibility for future ControlPlex® Rack extensions l No need to replace electronic circuit protectors in the event of future automation by means of RCI10 module l No system failures in the event of future automation by means of RCI10 module l Early failure detection due external alarm l Enhanced alarm indication on site by means of integral LED l Potential-free split-up group signalisation with contact terminals accessible from the front Technical data (Tamb = 25 °C, UB = DC 48 V) Operating data Operating voltage UB DC 20 V...DC 75 V (Power-D-Box® input voltage) Dielectric strength DC 100 V for 1 ms Current consumption1 typically 25 mA at DC 48 V operating voltage Power input1 typically 1.2 W Interfaces and connection technology Internal interface ELBus®/ power, 20-pole pcb connector External terminals two plug-in type 3-pole screw terminals with mating connector Auxiliary circuit (alarm contacts) Contact potential-free change-over contact Max. switching voltage DC 72 V Max. switching current 1 A Rupture capacity 60 W / 62.5 VA Status indication / momentary switch (function see table 1) Status LED multicoloured (red, green, blue) General data Mounting position vertical Design rack without enclosure Front plate mounting rack guidance with catch mechanism in the front plate Operating temperature -20...+60 °C (without condensation, cf. EN 60204-1) Storage temperature -20...+70 °C Humidity 96 hrs / 95 % RH / 40 °C to IEC 60068-2-78, test Cab. climate class 3K3 to EN 60721 Vibration 3 g to IEC 60068-2-6 Degree of protection IP00 DIN 40050 EMC requirements to EN 61000-6-3 & EN 61000-6-2 ESD 4kV / air 8kV Insulation co-ordination (IEC 60934) 0,6 kV/ pollution degree 2 reinforced insulation at operating area Approvals CE logo to EN 61000-6-3 & EN 61000-6-2 Conformity EN60950-1 / UL60950-1 compliant (when installed in PDB) Mass approx 60 g All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effective- ness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 112,4 101 1,5 33,4 11,6 22,25 27,2 67,7 15,6 Dimensions

www.e-t-a.de Remote Signalling Interface RSI10 ControlPlex® Rack 1623 Remote Signalling Interface RSI10 ControlPlex® Rack Table 1 Operating conditions and LED indication operating state circuit protector ESX300-S-3xx load output circuit protector ESX300-S-3xx LED status RSI10 sub-assembly auxiliary contact RSI10 sub-assembly group signal “NC contact” status RSI10 sub-assembly no error -> OFF locked green open normal operation normal operation connected green open normal operation error undervoltage with device in OFF condition (15V < U <37V) locked green closed normal operation error undervoltage with device in OFF condition (U > 72V) locked green closed normal operation overcurrent error detected (I > IN < 1.2 x IN); over- current failure has to be detected for approx. 30 sec before disconnection is effected connected green open normal operation error - overcurrent or short circuit disconnection locked green closed normal operation error undervoltage (15 V < U < 37 V) connected green closed normal operation error overvoltage (72 V < U < 75 V) connected green closed normal operation error: no voltage locked OFF (green) 1 closed normal operation1 error high temperature locked green closed normal operation protector check if ESX300-S-3xx bus version is plugged in internal bus error ESX300-S was identified 1 In a redundant system with two supply voltages the green LED lights if only one voltage supply fails, otherwise the RSI10 sub-assembly is dead-voltage.

www.e-t-a.de Remote Control Interface RCI10 ControlPlex® Rack 1623 Description – Remote control interface The Remote Control Interface RCI10 has been designed for the con- nection of the ControlPlex® Rack system to an superordinate control and monitoring unit. The Ethernet connection with integral SNMP protocol provides ease of implementation to a centralised management system. In addition the system can be controlled and monitored via a web browser surface. The RCI10 sub-assembly allows access to all installed ESX300-S circuit protectors by means of an internal bus system and can query or buffer individual measuring data, status conditions and fault indications and forward them to the superordi- nate control unit. In addition connected loads can be switched ON or OFF , either remotely or manually or in dependance of the data values. Major applications are in centralised control units of decentralised system, e.g. in telecommunications engineering. The Remote Control Interface type RCI10 can be extended in operation in the Power-D-Box (hot plug-and-play). Order numbering code RCI Remote Control Interface

10 Standard, pluggable (front plate, without housing)

0 with EL-BUS interface (standard) Voltage range (supply)

0 DC 20 V – DC 75 V

0 Ethernet with RJ45 connection

A IPv4, IPv6, SNMP v1, v2c, v3, http, https, SSH v2 RCI 10 - 0 0 0 - A ordering example Benefits l Extendable in operation in the ControlPlex® Rack (hot plug & play) l Early detection of errors with connected electronic assemblies by continuous recording of measuring data l Ease of network connection through standard Ethernet l Hazard reduction by active and remote disconnection of equipment, triggered by warning messages such as fire and/or water l Reduced maintenance because of remotely controllable power reset – no maintenance on site required l Integral software update function via network l Recording and evaluation of electrical consumption values Technical data (Tamb = 25 °C, UB = DC 48 V) Operating data Operating voltage range UB DC 20 V...DC 75 V (Power-D-Box ® input voltage) Dielectric strength DC 100 V for 1 ms Current consumption typically 80 mA at DC 48 V operating voltage Power consumption typically 3 W Max. power consumption 5 W Interfaces and protocols Internal connection ELBus®/ power, 20-pole pcb connector External connection 10 / 100 Mbit/s, 10 Base-T Ethernet, RJ45-connection sleeve for standard network cable of category Cat-5, type “Shielded Twisted Pair” http / https (Hypertext Transfer Protocol) Supported browser types integral web server internet explorer v9, Mozilla Firefox v28.8.1, Google Chrome v26.0 SNMP v1, v2c, v3 - protocol protocol for integration into a management system SNMP-MIB (management information base) file: CP-RCIxx_SNMP-MIB_Vxx.mib SSH v2 (Secure Shell) system configuration and safety settings Recommended SSH v2 terminal programme LePutty © 1997-2006 Simon Tathman NTP (Network Time Protocol) automatic time synchronisation via an NTP server IP protocol (internet pro- tocol) IPv4 and IPv6 address formats are supported DHCP-Server (Dynamic Host Config. Protocol) is supported, allows automatic assigment of network parameters such as the IP address System data Processor ARM Cortex A5 L1 Cache 2 x 32 KByte Operating system Linux Kernel, OpenEmbedded Volatile storage 256 Mbyte Non-volatile storage 128 Kbyte + 8 Mbyte Status indication / momentary switch (function see table 1) Status-LED multicoloured (red, green, blue) Reset momentary switch system reset; reset IP address to factory settings All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effective- ness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted.

www.e-t-a.de Remote Control Interface RCI10 ControlPlex® Rack 1623 Remote Control Interface RCI10 ControlPlex® Rack General data Mounting position vertical Style rack without enclosure Front plate mounting rack guidance with catch mechanism in the front plate Operating temperature -20...+60 °C (without condensation, cf. EN 60204-1) Storage temperature -30…+70 °C Humidity 96 hrs / 95% RH Humidity/40°C to IEC 60068-2-78, test Cab climate class 3K3 to EN60721 Vibration 3 g to IEC 60068-2-6, Degree of protection IP00 DIN 40050 EMC requirements to EN 61000-6-3 / EN 61000-6-2 ESD 4kV/air 8kV Insulation co-ordination (IEC 60934) 0.6 kV / pollution degree 2 reinforced insulation in the operating area Approvals CE logo to EN 61000-6-3 & EN 61000-6-2 Conformity EN 60950-1 / UL 60950-1 compliant (when installed in PDB) Mass typically 100 g Table 1 Indication of operating conditions via LED and momentary switch function Momentary switch Status LED colour Condition LED Meaning Description - green ON normal operation The green LED is lighted continuously when booting is completed and the RCI10 is operating faultlessly. Network connection can be established after another 10 sec. pushed down for 35 sec green blinking reset IP address to factory settings By pushing the reset button for 35 seconds, the IP settings can be reset to factory settings. For visual control that the reset button was pushed down long enough, the green LED will blink for 5 seconds (see fig. 1). - red ON internal failure RCI10 Serious internal fault in the RCI10 assembly. The sub-assembly is no longer operational. The RCI10 sub-assembly should be replaced. - red ON serious internal fail- ure BUS (EL-BUS) ELBus ® fault. The communication with the circuit protector ESX300-S and the RCI10 is disrupted. - blue ON Ethernet link available If a network connection is established in operation (layer 1), the LED will be lighted blue for some 10 seconds. - blue ON reset IP address to factory settings The blue LED will be lighted for 10 seconds when the IP address has successfully been reset to factory settings, see fig. 1. Automatic booting will follow, this can last up to 60 seconds. - - OFF booting The RCI10 sub-assembly is booting. Booting can take up to 60 seconds. - - OFF no supply voltage No supply voltage or wrong polarity. pushed down for 3 sec - OFF warm boot The system can be reset by pushing the reset button for 3 seconds (warm boot). - OFF RCI10 sub-assembly defective Serious internal fault in the RCI10 assembly. LED remains dark after booting (max. 60 sec). The RCI10 sub-assembly must be replaced. Pin assignment of 20-pin pcb connector Shield A1 NC A2 NC A3 Suppy (+) A4 NC A5 NC A6 Supply (-) NC EL-BUS Supply (-) Shield NC NC Suppy (+) NC NC Supply (-) Supply (-) Red_Sys Supply (-) A10 B10

www.e-t-a.de Remote Control Interface RCI10 ControlPlex® Rack 1623 Fig. 1: Function IP-reset by pressing the reset button with LED Dimensions Front RCI10 Legal references and licences http://www.e-t-a.de/Licenses reset button green greengreen blue status LED approx 3 s 30 s 10 s max. 5 s System-Reset 1.5 Outside the shown area free of components status LED green momentary switch Contacting area of connector 15.611.6 67.7 22.25 27.2 12.3 62.1 112.4 101 2.8 RGB status LED RJ45 / Ethernet engagement nose momentary switch / resetlabel