PCN1-S_V01 CUI | Alldatasheet
Document overview
- Manufacturer or author: Provided By www.digicamel.com(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 9
Technical content
cui.com date 07/01/2021 page 1 of 9 SERIES: PCN1-S │ DESCRIPTION: DC-DC CONVERTER
FEATURES
- up to 1 W isolated output
- industry standard SIP package
- nominal input voltages: 5, 12, 24 Vdc
- single/dual unregulated output
- 1,500 Vdc isolation voltage
- low ripple and noise
- -40 to 100°C
- efficiency up to 83% MODEL input voltage output voltage output current output power ripple & noise1 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) max (mVp-p) typ (%) PCN1-S5-S5-S 5 4.5~5.5 5 0 200 1 75 79 PCN1-S5-S12-S 5 4.5~5.5 12 0 84 1 75 79 PCN1-S5-S15-S 5 4.5~5.5 15 0 67 1 75 79 PCN1-S5-D5-S 5 4.5~5.5 ±5 0 ±100 1 75 74 PCN1-S5-D12-S 5 4.5~5.5 ±12 0 ±42 1 75 78 PCN1-S5-D15-S 5 4.5~5.5 ±15 0 ±33 1 75 78 PCN1-S12-S5-S 12 10.8~13.2 5 0 200 1 75 80 PCN1-S12-S12-S 12 10.8~13.2 12 0 84 1 75 81 PCN1-S12-S15-S 12 10.8~13.2 15 0 67 1 75 81 PCN1-S12-D5-S 12 10.8~13.2 ±5 0 ±100 1 75 77 PCN1-S12-D12-S 12 10.8~13.2 ±12 0 ±42 1 75 80 PCN1-S12-D15-S 12 10.8~13.2 ±15 0 ±33 1 75 81 PCN1-S24-S5-S 24 21.6~26.4 5 0 200 1 75 80 PCN1-S24-S12-S 24 21.6~26.4 12 0 84 1 75 83 PCN1-S24-S15-S 24 21.6~26.4 15 0 67 1 75 81 PCN1-S24-D5-S 24 21.6~26.4 ±5 0 ±100 1 75 79 PCN1-S24-D12-S 24 21.6~26.4 ±12 0 ±42 1 75 81 PCN1-S24-D15-S 24 21.6~26.4 ±15 0 ±33 1 75 82 Notes: 1. At full load, nominal input, 20 MHz bandwidth oscilloscope, with a 0.33 µF ceramic capacitor on the output. 2. Required to add a 2.2 µF (5 & 12 Vdc input models) or 4.7 µF (24 Vdc input models) ceramic capacitor to the input to reduce input voltage stress. 3. All specifications are measured at Ta=25°C, nominal input voltage, and rated output load unless otherwise specified. PART NUMBER KEY Base Number Packaging Style: S = SIP PCN1 - SXX - X XX - S Output S = single D = dual Input Voltage Output Voltage Additional Resources: Product Page | 3D Model | PCB Footprint
cui.com date 07/01/2021 │ page 2 of 9CUI Inc │ SERIES: PCN1-S │ DESCRIPTION: DC-DC CONVERTER INPUT parameter conditions/description min typ max units operating input voltage
5 Vdc input models
12 Vdc input models
24 Vdc input models
4.5 10.8 21.6 5.5 13.2 26.4 Vdc Vdc Vdc surge voltage for maximum of 100 ms input reverse polarity protection no input fuse 0.5 A time delay fuse for all models (recommended) Notes: 1. Required to add a 2.2 µF (5 & 12 Vdc input models) or 4.7 µF (24 Vdc input models) ceramic capacitor to the input to reduce input voltage stress. OUTPUT parameter conditions/description min typ max units maximum capacitive load single output models dual output models 220 100 μF μF voltage accuracy ±3.0 % line regulation 1.0% change in input voltage ±1.2 % load regulation from 20% load to full load ±10 % switching frequency at nominal Vin, full load temperature coefficient ±0.05 %/°C PROTECTIONS parameter conditions/description min typ max units short circuit protection momentary 1 s SAFETY AND COMPLIANCE parameter conditions/description min typ max units isolation voltage input to output for 1 minute 1,500 Vdc isolation resistance input to output 1,000 MΩ isolation capacitance input to output 10 pF conducted emissions EN 55022 Class B (external circuit required, see Figure 4) MTBF as per MIL-HDBK-217F, full load, GB, 25°C 1,500,000 hours RoHS 2011/65/EU ENVIRONMENTAL parameter conditions/description min typ max units operating temperature see derating curve -40 100 °C storage temperature -55 125 °C operating humidity non-condensing 95 % Additional Resources: Product Page | 3D Model | PCB Footprint
cui.com date 07/01/2021 │ page 3 of 9CUI Inc │ SERIES: PCN1-S │ DESCRIPTION: DC-DC CONVERTER 0.02 [0.5] 0.40 [10.2] 0.08 [2.1] 0.13 [3.2] 0.77 [19.5] 0.100 [2.54] 0.010 [0.25] 0.06 [1.6] 21 4 0.24 [6.1] 0.73 [18.5] 0.020[0.50] 21 4 65 0.07 [1.8] 0.010 [0.25] 0.020[0.50] 0.73 [18.5] 0.28[7.2] 21 4 65 0.24[6.1] 0.058 [1.48] 0.093 [2.35] 0.77[19.5] 0.100 [2.54] 0.300 [7.62] 0.8mm PLATED THROUGH HOLE 1.5mm PAD SIZE Recommended PCB Layout Top View 21 4 65 0.28[7.2] 0.066[1.68] 0.093 [2.35] 0.77[19.5] 0.100 [2.54] 0.300 [7.62] 0.8mm PLATED THROUGH HOLE 1.5mm PAD SIZE Recommended PCB Layout Top View 0.02 [0.5] 0.40 [10.2] 0.08 [2.1] 0.13 [3.2] 0.77 [19.5] 0.100 [2.54] SOLDERABILITY parameter conditions/description min typ max units wave soldering see wave soldering profile 260 °C Temperature (°C) Time (Seconds) Notes: 1. Soldering materials: Sn/Cu/Ni 2. Ramp up rate during preheat: 1.4°C/s (from 50°C to 100°C) 3. Soaking temperature: 0.5°C/s (from 100°C to 130°C), 60±20 seconds 4. Peak temperature: 260°C, above 250°C for 3~6 seconds 5. Ramp down rate during cooling: -10°C/s (from 260°C to 150°C) units: inches [mm] tolerance: X.XX ±0.01 [±0.25] pin section tolerance: ±0.002[±0.05] PIN CONNECTIONS PIN Function Single Dual 1 +Vin +Vin 2 -Vin -Vin 4 -Vout -Vout
5 No pin Common
parameter conditions/description min typ max units inches inches case material non-conductive black plastic weight 24 Vdc input models all other models 2.7 1.8 g g MECHANICAL DRAWING
24 Vdc input models5, 12 Vdc input models
Additional Resources: Product Page | 3D Model | PCB Footprint
cui.com date 07/01/2021 │ page 4 of 9CUI Inc │ SERIES: PCN1-S │ DESCRIPTION: DC-DC CONVERTER DERATING CURVE EFFICIENCY CURVES Additional Resources: Product Page | 3D Model | PCB Footprint
cui.com date 07/01/2021 │ page 5 of 9CUI Inc │ SERIES: PCN1-S │ DESCRIPTION: DC-DC CONVERTER EFFICIENCY CURVES (CONTINUED) Additional Resources: Product Page | 3D Model | PCB Footprint
cui.com date 07/01/2021 │ page 6 of 9CUI Inc │ SERIES: PCN1-S │ DESCRIPTION: DC-DC CONVERTER EFFICIENCY CURVES (CONTINUED) Additional Resources: Product Page | 3D Model | PCB Footprint
cui.com date 07/01/2021 │ page 7 of 9CUI Inc │ SERIES: PCN1-S │ DESCRIPTION: DC-DC CONVERTER EFFICIENCY CURVES (CONTINUED) PACKAGING units: mm Tube size: 17.2 x 9 x 340 mm QTY: 16 pcs 5, 12 Vdc input models units: mm Tube size: 20 x 11 x 340 mm QTY: 14 pcs Additional Resources: Product Page | 3D Model | PCB Footprint
date 07/01/2021 │ page 9 of 9CUI Inc │ SERIES: PCN1-S │ DESCRIPTION: DC-DC CONVERTER CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com rev. description date 1.0 initial release 07/26/2016 1.01 company logo updated 04/12/2021 1.02 derating curve, efficiency curves and circuit figures updated 07/01/2021 The revision history provided is for informational purposes only and is believed to be accurate.
REVISION HISTORY
Additional Resources: Product Page | 3D Model | PCB Footprint