Features
Distributed DA&C Systems ADAM-5000/485 ADAM-5000E Introduction The ADAM-5000/485 and ADAM-5000E systems use the EIA RS-485 communication protocol. This is the industry's most widely used, balanced, bidirectional transmission line standard. The RS-485 was specifically developed for industrial applications to transmit and receive data at high rates over long distances. Processor CPU 16-bit microprocessor I/O module capacity 4 or 8 Watchdog Timer Yes Power Consumption 1.0 W (ADAM-5000/485)
4.0 W (ADAM-5000E)
Communication 2500 VDC (ADAM-5000/485) Isolation 3000 VDC (ADAM-5000E) Communication Power 3000 VDC Isolation I/O Module Isolation 3000 VDC Diagnosis Status Display Power, CPU, communication Self-test Yes, while on Software Diagnosis Yes Communication Network RS-232 or RS-485 (2-wire) to host Speeds (bps) 1200, 2400, 4800, 9600, 19.2 k, 38.4 k, 57.6 k, and 115.2 kbps Max. Communication 4000 feet (1.2 km) Distance Command Format ASCII command/response protocol Reliability Check Communication error checking with checksum Asynchronous 1 start bit, 8 data bits, 1 stop bit, no parity Data Format Maximum Nodes Up to 256 multi-drop systems per host serial port Protection Transient suppression on RS-485 communication lines Power Requirements Unregulated +10 to +30 VDC Protected against Power Reversal Power Protection Transient suppression on power input Mechanical Case KJW with captive mounting hardware Plug-in Screw Accepts 0.5 mm2 to 2.5 mm2 , 1 - #12 or 2 - #14 to Terminal Block #22 AWG Environment Operating Temperature -10 ~ 70° C (14 ~ 158° F) Storage Temperature -25 ~ 85° C (-13 ~ 185° F) Humidity 5 ~ 95%, non-condensing
Ordering Information
ADAM-5000/485 Distributed DA&C System Based on RS-485 (4 slot) ADAM-5000E Distributed DA&C System Based on RS-485 (8 slot) PCLS-OPC/ADM OPC Server for ADAM-4000/5000 Series (RS-485) PCLS-OCX ActiveX Control for Data Acquisition and Control PCLS-ADAMVIEW32 ADAMView Data Acquisition Software RS-485 Communication for easy installation and networking 4 or 8 slots for up to 128 points data monitoning card control in one module Extensive Software support, inclucles windows DLL drivers, OCX drivers, OPC server and popular HMI/SCAPA Software driver. Seamlessly inteqrated with easy-to-use ADAMView data acquisition Software. Distributed DA&C System Based on RS-485
www.advantech.com/productsOnline Download All product specifications are subject to change without notice Last updated : January 2005 Feature Details Two-wire Communication The ADAM-5000/485 and ADAM-5000E systems use a single twisted pair of wires to transmit and receive data. Special circuitry ensures clean, reliable communication and suppresses communication line noise. This reduces overall network cost by simplifying installation and minimizing the number of cables, connectors, communication repeaters and filters required. Surge Protection High-speed transient suppressors protect the system from dangerous voltage surges or power spikes. Network Expansion The ADAM-4510 repeater simply amplifies or boosts existing signals, enabling them to travel over longer distances. Each repeater allows you to add up to 32 ADAM-5000 units to your network, extending the network by another 4000 feet (1.2 km). Up to 256 ADAM-5000/485, ADAM-5000E units can be connected to a single RS-485 network. RS-232 to RS-485 Conversion RS-232 serial ports are standard with most industrial computer systems. Though widely accepted, RS-232 has limited transmission speed, range and networking capabilities. The RS-485 standard overcomes these limitations by using differential voltage lines for data and control signals. The ADAM-4520's isolated converter lets you take advantage of an RS-485 on an RS-232 system by converting RS-232 signals to RS-485 signals. Software written for half-duplex RS-232 may also be used without modification. The ADAM-4520 helps you build an industrial grade, long distance communication system with standard PC hardware. Panel/rack mounting hole Communication terminal (RS-485 port) Power terminal Diagnostic LED Panel/rack mounting hole Plug-in terminal DIP switch RS-485 port Locking buttons Industrial connector RS-485 port RS-232 port Intelligent RS-485 Data Flow Control The RS-485 communication protocol will support half-duplex communication. Only two wires are needed for transmitting and receiving data. Handshaking signals such as RTS (Request to Send) normally control the direction of the data flow. A special I/O circuit in the ADAM-4510 and ADAM-4520 senses the data flow direction and automatically switches the transmission direction, making handshaking signals unnecessary. The RS-485 bus control is completely transparent to the user. Built-in RS-232 Communication ADAM-5000/485 and ADAM-5000E systems provide up to 64/128 I/O points and an RS-232 port. A host PC can be locally connected to the system to control and monitor simple applications, thereby facilitating local troubleshooting. ASCII-based Protocol ADAM-5000 commands are issued in printable ASCII-based format. ADAM applications can be written in any high-level language that supports ASCII string functions, such as C, Pascal or BASIC. ASCII support means you can use virtually any computer to manage your ADAM network. ADAM-5000/485 ADAM-5000E