PCI500-4A CANDD | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 4
Technical content
PCI500-4A 3/2001 REV C Page 1 PCI500-4APCI500-4A POWER ELECTRONICS DIVISION AC/DC Compact PCI Power Supply POWER: 500 Watt AC/DC SIZE: 5.08” X 12.27” X 4.48” NUMBER OF OUTPUTS: 4 www.cdtechno.com click on Power Electronics PRODUCT DAPRODUCT DAPRODUCT DAPRODUCT DAPRODUCT DA TTTTTA SHEETA SHEETA SHEETA SHEETA SHEET
DESCRIPTION
The PCI500-4A is a modular, 500 watt, quad output power supply with active power factor correction. This hot-swap supply is designed specifically for redundant applications with active current sharing on the 5V and 3.3V outputs. The PCI500 incorporates a unique architecture that supports migration of 5V requirements to 3.3V by deriving both of these outputs from a common winding on the main transformer. The PCI500 is also ideal for networking equipment, communications and computer equipment where fault-tolerance is a necessity. A DC-input counterpart is available as the PCI500-4D for telecommunications environments. All outputs have remote sense and are individually protected against overloads and short circuits. With UL/cUL approval to UL1950, VDE approval to EN60950, CE Mark, and EMI compliance to FCC/CISPR22 Class B, the PCI500 provides a truly global power solution for your CompactPCI TM requirements. AGENCY APPROVALS
FEATURES
!!!!! 90-264 VAC INPUT RANGE !!!!! ACTIVE POWER FACTOR CORRECTION !!!!! 500 WATT CONTINUOUS OUTPUT POWER !!!!! OUTPUTS INDIVIDUALLY PROTECTED AGAINST OVERLOADS; AUTOMATIC RECOVERY !!!!! QUAD OUTPUT CONFIGURATION !!!!! MEETS EMISSIONS SPECIFICATION FCC/EN55022 CLASS B !!!!! SAFETY AGENCY APPROVED !!!!! NO MINIMUM LOAD REQUIRED !!!!! 83A COMBINED CURRENT FROM V1, V2 Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s intended purpose and in user’s specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace applications. Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Phone: 800.547.2537 Fax: 520.770.9369 Power Electronics Division, Europe C&D Technologies (Power Electronics) Ltd. 132 Shannon Industrial Estate, Shannon, Co. Clare, Ireland C&D Technologies, (NCL) Tanners Drive Blakelands North Milton Keynes MK14 5BU UK Tel: +44 (0)1908 615232 Fax: +44 (0)1908 617545
PCI500-4A 3/2001 REV CPage 2 PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Input Voltage V in 47-63Hz 90 264 V AC Inrush Current 120VAC input (cold start) 37 A PK 240VAC input (cold start) 75 A PK Input Surge 1 second duration 300 V AC Power Factor* PF 120 V AC input, 500W load 0.99 *Harmonic Correction meets EN61000-3-2 (formerly IEC 555-2) +5V ADJ +12V ADJ -12V ADJ +3.3 ADJ 5.08 3.346.865 4.48 4.213 DC GOOD FAN GOOD POWER PRESENT 12.27 .171 2.18 .692 1.88 2.693 3.300 3.46 .68Input Connector Output Connector COMMON INPUT CHARACTERISTICS ENVIRONMENTAL/SAFETY The PCI500-4A is safety certified to UL/cUL 1950, EN60950/IEC 950. It is in agreement with the Global Emissions Compliance as specified by FCC Pt. 15 Class B.; CISPR 22/EN55022, Class B. It meets the Global Immunity Compliance as specified by EN 61000-4-2, -3, -4 and -5, Level 3. The Input Transient Protection is IEEE C62.41-1991, Class A2, IEEE 587B. The Power Module is CE marked in compliance with the low volt- age directive. Parameter Min Typ Max Units Temperature Operation 0 +40 C ° Storage -20 +70 C ° Altitude Operating Non-Operating Humidity SPECIFICATION CHART 95% max. (non-condensing) up to 10,000 feet up to 40,000 feet NOTES: All dimensions are in inches. COOLING: Internal fan supplied. SHOCK: MIL-STD-810D, Method 516.3, Procedure 1 VIBRATION: MIL-STD-810D, Method 514.3, Procedure 1 PIN ASSIGNMENTS: See chart on page 4. WEIGHT: 8 lbs. MECHANICAL INPUT Elcon 278-0454-00200B9926 OUTPUT Elcon 278-0453-00200B9925A MATING CONNECTORS (BACKPLANE) * The dimension from the rear of the front panel to the mating surface of the I/O connectors is 11.775”.
PCI500-4A 3/2001 REV C Page 3 IOUT VOUT RATED OUTPUT CURRENT OUTPUT NUMBER RATED OUTPUT VOLTAGE MIN MAX V1 +5.0V 0A 74A* V2 +3.3V 0A 60A* V3 +12.0V 0A 10A V4 -12.0V 0A 2.5A OUTPUT VOLTAGE/CURRENT NOTES: Outputs 1 and 2 share common return. Outputs 3 and 4 have isolated Returns. *Combined current output of 1 and 2 not to exceed 83A. Transient Response For a step load change of 25%, the peak output voltage excursion will not exceed 5% of nominal voltage, and will recover within 1% of nominal voltage in 400 microsec- onds. Output Isolation All outputs isolated from chassis. Holdup Time 50 mSec minimum holdup at 250W load. Holdup time is approximately inversely proportional to the load. Remote Sense Remote Sense is on all outputs and is capable of com- pensating for 0.7V of line drop. Automatic local sensing is enabled on all outputs when remote sense leads are open. Remote sense leads are protected for open, reverse, and shorted conditions. Hot Pluggable Active Current Share circuitry on outputs V1 and V2, to- gether with ORing diodes on all outputs and synchro- nous starting circuitry, allow for hot-swap in redundant applications. COMMON OUTPUT CHARACTERISTICS REGULATION (All Outputs) PARAMETER LIMIT Line ± 0.2% Load ±0.5% Cross ±0.2% COMMON OUTPUT SPECIFICATIONS PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS Voltage Adjustment All outputs ±5 % Temperature Coefficient TC 0-40 °C ambient after 0.02 %/ °C 30 minute warm-up PARD 20MHz bandwidth 1% P-P or 50mV P-P whichever is greater Output Power 40 °C max temp. 500 W
PCI500-4A 3/2001 REV CPage 4 OUTPUT CONNECT OR WIRING PIN # FUNCTION 45 to 54 +3.3V 55 to 64 +3.3V 85 to 94 +5V 95 to 104 +5V 65 to 74 GND (3.3V/5V) 75 to 84 GND (3.3V/5V) 1 to 10 +12V 11 to 20 GND (+12V) 24, 25, 28 -12V 21 to 23 GND (-12V) 29 +5V Sense 39 +3.3V Sense 41 +12V Sense 35 -12V Sense 34 (Short) Hot Swap Enable 33 +5V Current Share 27 +3.3V Current Share 26 +5V Sense RTN 36 +3.3V Sense RTN 38 +12V Sense RTN 32 -12V Sense RTN
44 Fan Alarm
30 DC Good
42 Remote Inhibit
37 Power Supply Present (GND)
40 GND
43 GND
31 Sync Start
PIN # FUNCTION 1 to 10 AC Line 11 to 20 AC Neutral 21 to 30 (Long) Chassis GND 21-30 95-104 85-94 75-84 65-74 55-64 45-5411-20 1-10 1-10 11-20 Hot Swap Short Pin "Postmate" Long Pin, Premate CONNECTOR PINOUT DIAGRAMPINOUT ASSIGNMENTS OUTPUT PROTECTION Over Current/Short Circuit Protection: Outputs individually protected against overload and indefi- nite short circuit; automatic recovery after removal of fault. Over Voltage Protection: Output #1: 6.5V ±.5VDC typical Output #2 4.3V ±.4VDC typical Over Voltage Protection will latch the power supply off until input power is cycled. Power Limit: Auto recovery; at 530W output power typical, the unit will cycle. Reverse Voltage Protection: All outputs protected up to rated current. Over Temperature Protection: Over Temperature shutdown with automatic recovery. CONTROL/ALARM SIGNALS Remote Inhibit: Referenced to RTN (Logic), Pin 40 or 43. The power supply is off when the Remote Inhibit is less than 1V, typical. Power Present LED: A green LED will light when AC is applied and exceeds mini- mum operating limits. DC Good Indicator: A green LED will be illuminated when all outputs are be- tween 90% and 110% (typical) of their nominal output volt- age and extinguish when any voltage is out of this range. Fan Fail: TTL level signal goes low when fan fails. Referenced to RTN (Logic), Pin 40 or 43. A green LED gives a visual indication that the fan is operational. DC OK: An open collector output signal with an internal 2.2KΩ pull up resistor is connected to the +5V output. TTL signal will go high when all outputs are between 90% and 110% of their nominal output voltage. Sync Start A power supply generated signal used to simultaneously start supplies operated in parallel. These pins must be tied together at the backplane in parallel/redundant (N+0 or N+n) applications when N>1. In simple redundant (1+1) or non- parallel (1+0) applications, the pin can be ignored. Current Share Bus A power supply generated signal used to force current shar- ing between supplies operated in parallel (V1 and V2). These pins must be tied together at the backplane (5V CS to 5V CS and 3.3V CS to 3.3V CS). Hot Swap Enable This pin must be tied to the DC GND at the backplane for the power supply to operate. Since this pin is staged as the shortest in the connectors, it is a “last-make/first break” pin. Power Supply Present This pin presents a DC ground signal to the mating pin in the backplane. It is intended to be used by the system to detect if a power supply module is plugged into an available position. CONTROL/ALARM SIGNALS (cont’d)