SPE-11-8-045/E Page 1 of 11 Specification Part No. : PC29.09.0100A Product Name : TheStripe™ Penta-band Cellular 850 / 900 / 1800 / 1900 UMTS / WCDMA (3G) 2100 MHz PCB Antenna Feature : 100mm long, 1.13 mm diameter Miniature Co-axial Cable MMCX(M)RA Average Efficiency 62% Tested in Free space Dims: 80*30mm RoHS Compliant

SPE-11-8-045/E Page 2 of 11 1. Introduction This high performance, low profile, PCB antenna is based on smart TheStripe™ antenna technology. It consists of a PCB antenna and mini coaxial cable. The product is a high gain Penta-band 850/900/1800/1900/2100 antenna suitable for worldwide GSM, UMTS and WCDMA applications. Its high efficiency (62% average) makes it an ideal choice to pass telecom operator’s testing approvals. The product should be tested in free space conditions connected to the client’s cellular device. Further optimization can be done upon receipt of the client’s device at a local Taoglas facility. 2. Specifications CELLULAR Communication system AMPS GSM DCS PCS UMTS/WCDMA Frequency Band 850MHz 900MHz 1800MHz 1900MHz 2100MHz Impedance 50 Ohm Radiation Pattern Omnidirectional Polarization Horizontal MECHANCIAL Dimensions 80 * 30mm RF Cable RF Coaxial Cable ψ1.13 ± 0.1mm, L = 100 mm Gray Color RF Connector MMCX(M)RA ENVIRONMENTAL Operation Temperature -40°C to + 85°C Storage Temperature -40°C to + 95°C Relative Humidity 40% to 95%

SPE-11-8-045/E Page 3 of 11 3. Antenna Characteristics 3.1. Return loss

SPE-11-8-045/E Page 4 of 11 4. Reliability Test Items Procedure Requirement Thermal Shock Starting at -40 for 30minutes and then cycled to +85 to remain 30minutes (a complete cycle). To repeat 5 complete cycles. (Refer to IEC 68-2-14 Method Na) 1. The value of return loss must be within product specifications after this test. 2. No physical deformation should be evident. Storage Temperature (Cold) Samples must be put into -30°C chamber for 72 hours and samples shall be powered during test. (Refer to IEC 68-2-1 Method Aa) 1. The value of return loss must be within product specifications after this test. 2. No physical deformation should be evident. Storage Temperature (Dry Heat) Samples must be put into +75°C chamber for 72 hours and samples shall be powered during test. (Refer to IEC 68-2-1 Method Ba) 1. The value of return loss must be within product specifications after this test. 2. No physical deformation should be evident. Operating Temperature (Cold) Samples must be put into -20°C chamber for 2 hours and samples shall be powered during test. (Refer to IEC 68-2-1 Method Aa) 1. The value of return loss must met specification during test/after test 2. No mechanical defects after test. Operating Temperature (Dry Heat) Samples must be put into +65°C chamber for 72 hours and samples shall be powered during test. (Refer to IEC 68-2-1 Method Ba) 1. The value of return loss must met specification during test/after test 2. No mechanical defects after test.

SPE-11-8-045/E Page 5 of 11 5. Antenna Test Procedures and Setup 5.1. Test Procedure for VSWR/Return Loss 5.1.1. STEP 1 Route Cable in Correct Position 5.1.2. STEP 2 Connect Antenna to Module Connect feed-line to network analyze 5.1.3. STEP 3 - Assemble Antenna in Correct Position 5.1.4. STEP 4 - Assemble Housing 5.2. 3D Radiation Pattern Testing Test Setup Diagram

SPE-11-8-045/E Page 6 of 11 5.3. 3D Radiation Pattern Testing 850MHz 900MHz

SPE-11-8-045/E Page 7 of 11 1800MHz 1900 MHz 2100MHz

SPE-11-8-045/E Page 8 of 11 5.4. 3D Chamber Testing – Tabular Results

SPE-11-8-045/E Page 9 of 11 6. Mechanical Drawings (Unit: mm) 6.1. Dimensions and Drawing 6.2. Antenna Placement Antenna designed to for testing when connected outside the client’s device and placed in frees pace conditions, for example on plastic foam block. Final product can use pre- applied double sided adhesive tape, slot or screw mount.

SPE-11-8-045/E Page 10 of 11 7. Packaging (Unit: mm)

SPE-11-8-045/E Page 11 of 11 Taoglas makes no warranties based on the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications and product descriptions at any time without notice. Taoglas reserves the rights to this document and the information contained herein. Reproduction, use or disclosure to third parties without express permission is strictly prohibited. Copyright © Taoglas Ltd.