PBW-1201 LAMBDA | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
(1) For equipment designed to conform EMI regulations such as VCCI, CISPR, FCC, VDE, etc. (2) Attenuates conductive emission from power supply (3) Leakage current: 1mA max. (250V, 60Hz) (4) Compact and light weight m Safety standard UL1283, CSA Std. C22. 2 No. 8 VDE0565 Teil. 3 VDE0565 will transfer to EN133200 on and after July 23, 2003. m Specifications Rated voltage (AC, DC) Rated current (AC, DC) (Note) Test voltage (terminal to case, AC 1 minute) Isolation resistance (terminal to case, 500VDC) Leakage current DC resistance Temperature rise Operating temperature range Weight (typ) 250V 1500V 100M Ω min. 0.35mA max. 0.75mA max. 30°C max. –25 ~ +85°C 1A 2A 3A 6A Item Model PBW-1201-33 PBW-1202-33 PBW-1203-33 PBW-1206-33 60g 60g 60g 60g 125V, 60Hz 250V, 60Hz m Circuit m Derating (Note) : Value at Ta 55°C. Refer to the derating curve shown below at Ta > 55°C. v Request customer specification for further details of specifications, outline, characteristics, etc. Read the instruction manual before usage. v Contact us about delivery before ordering. m Outline drawings PBW-1203 PBW-1201 PBW-1206 PBW-1202 Case: Plastic (PBT: UL94V-0) (Unit: mm)
———— Asymmetrical Frequency (MHz) Frequency (MHz) Frequency (MHz) Frequency (MHz) Attenuation (dB) Attenuation (dB) Attenuation (dB) Attenuation (dB) CHARACTERISTICS m Typical Insertion Loss