PBO-200 SLPOWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

MODEL PWR OUTPUT #1 OUTPUT #2 OUTPUT #3 OUTPUT #4 (Cont.) @ @ @ @ (Peak) 6.0 A (Peak) 6.0 A (Peak)

200 WATTS

WIDE RANGE ADJUSTABLE MULTIPLE OUTPUTS The PBO 200 series of high-reliability, AC input power supplies are designed for computer, networking, telecommuni- cation and industrial equipment applica- tions. These models feature a universal power factor corrected input plus inde- pendently isolated and regulated out- puts. The auxiliary outputs are adjustable over a wide range (up to 2.6 to 1). This wide range of adjustability provides greater flexibility, especially in meeting non-standard output voltage require- ments. Outputs may be connected in either polarity or stacked in series as needed. Outputs 2 and 3 accommo- date up to 50% greater peak currents for applications with surge require- ments. The optional cover with fan pro- vides a low-profile cooling solution that increases the overall height by only 0.25”. STANDARD PBO SERIES Option CF PBO-200 Featuring:

  • 200 W continuous – 240 W peak power
  • Universal input for 115 V or 230 V, 47-65 Hz, single phase AC
  • Four independently isolated and regulated outputs
  • Wide range of adjustable auxiliary outputs (up to 2.6:1)
  • Up to 50% greater peak currents on two outputs
  • Typical power factor – 0.99
  • Low ripple and noise on all outputs
  • Typical 70% efficiency
  • DC power good signal
  • Remote on/off and remote sense

features

  • Low profile fan/cover option

FUNCTION 115 VAC 230 VAC CONNECTOR TB1- Line Line 1 TB1- Neutral Line 2 TB1- Safety Ground Safety Ground AC INPUT (90-264 VAC Continuous Range) FUNCTION LOCATION NOTES CONNECTOR Output #1 TB2-1 4.75V to 5.25V TB2-2 Rtn (Isolated) Output #2 TB3-1 11.5V to 25.2V TB3-2 Rtn (Isolated) Output #3 TB3-3 9.5V to 15.8V TB3-4 Rtn (Isolated) Output #4 TB3-5 4.75V to 12.6V TB3-6 Rtn (Isolated) DC OUTPUT Barrier strip #6-32 screws 0.325 inch centers Bus Bars # 8 - 32 Screws Barrier strip #6-32 screws 0.375 inch centers FUNCTION LOCATION STATUS CONNECTOR Enable J1-1 Enable J1-2 Output #1 Rtn DC Power Good J1-4 DC Power Good J1-3 Output #1 Rtn Remote Sense J2-2 Output #1 Sense + J2-1 Output #1 Sense - STATUS AND CONTROL Molex part # 22 - 23 - 2041 mates with Molex part # 22 - 01 - 3047 SPECIFICATIONS: ALL MODELS INPUT AC Input: 85-264 V AC continuous range, 47 to 65 Hz. Internally fused at 6.3 A. Power Factor: 0.99 typical at full load. Meets EN61000-3-2. Inrush: Cold start AC current is less than 35 A at 115 Vac and 70 A at 230 Vac. Limited by a thermistor. Brownout Protection: Holds regulation to 85 Vac. Holdup Time: 20 ms after removal of power at nominal line and full load. Efficiency: 75% typical. AC Power Fail: Provides TTL “0” 6 ms before output voltage goes out of regulation band upon loss of ac power. Also provides a TTL level “0” for 100 ms (minimum) at starting. OUTPUT Adjustability: Output #1 is adjustable ±5%. Output #3 and 4 are wide range adjustable, (see table). Line & Load Reg: ±0.6% on all outputs over AC input range and loads within the ranges specified in the table. Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater. Remote Sense (Output #1): Compensates for 250 mV total line drop. Open sense lead protection. Temperature Coefficient: To be determined. Stability: 0.1% over 8 hours after 30 minutes warm-up. Transient Response: Output voltage returns to within 1% in less than 500 µs for a 25% load change. Peak transient does not exceed 3%. Overload Protection: All outputs are protected against overload and Input Cycling off/on is required to reset latched-off protection mode. Overvoltage Protection (Output #1): Protects load against power supply induced overvoltage. Trip point is factory set so that output voltage cannot exceed 6.5 V. Peak Output Current: (Outputs #2 and 3) Dual current ratings define continuous and peak currents. The peak current shown can be delivered for a maximum period of 15 seconds. Remote Inhibit: Contact closure to the negative sense line or a TTL level “0” turns off DC outputs. DC Power Good: Provides a TTL “1” open collector when output #1 is above 4.6 V nominal. Redundancy: External OR-ing diodes and forced current sharing on output #1 provide “N+1” capability. Remote sense (+S) compensates for additional 0.6 V diode voltage drop. When the current sharing terminal is connected between units, current sharing remains within 10% of the unit’s full output current rating. Reverse Voltage: Protected against reverse voltage up to supply current rating. Cooling: 30 CFM required to achieve full ratings. Enable: Contact closure in the negative output #1 terminal or a TTL level “0”, turns off DC outputs. 9”x 5”x 2” PBO-200 (L) (N) ( ) Dimensions: Inches Millimeters ENVIRONMENTAL Thermal Protection: Shuts down power supply if overheated. Automatic recovery. Temperature Range: 0° to 40°C at full ratings.Output power linearly derated to 50% at 70°C. Safety Agencies: UL1950; CSA 22.2 #950; VDE 0805 / EN 60950 CE markings to low voltage directive – All pending. Conducted RFI: Meets FCC Part 151 Class B. EN 55022/B. Output Isolation: Isolated from ground 50 Vdc. Cooling: 30 CFM required to achieve full ratings. OPTIONS: Option CF: Available with enclosed cover and fan. Consult factory for other available options. PBO-200 2.7 lbs - 1.4 kgs Molex part # 22 - 23 - 2021 mates with Molex part # 22 - 01 - 3027