CONVENTIONAL POWER DISTRIBUTION SYSTEMS Power board modules PBM V0060 The power distribution system has been designed to accommoda- te plug-in type thermal 1170-21, 1180 and 1610 circuit breakers. It is designed as printed circuit board m odule for rail m ounting. Ty- pical applications are m ainly in control cabinets for utility vehicles and special vehicles and for mobile construction machinery. The current supplied by a power supply is distributed onto 5 ways/ slots. There are tw o LE Ds for each circuit breaker. W hen the cir- cuit breaker has tripped, the red LE D lights up. The green LE D is lighted when the circuit breaker is in ON condition. The distribu- tion m odule generates a group signalling. This signal can be en- quired via a potential-free relay. The jum pers allow bridging the si- gnalling for individual circuit breakers if those are not fitted. CONVENTIONAL POWER DISTRIBUTION SYSTEMS Power board modules TYPICAL FEATURES YOUR BENEFITS

  • Power distribution system for rail mounting
  • Rated voltage DC 12 V / DC 24 V
  • max. 25 A per load channel
  • Different circuit breakers can be plugged in
  • Signalling via relays and LEDs
  • Space savings through PC B technology
  • Clear circuit breaker status indication
  • Quick and easy mounting
  • Easy and weight-optimised cable management PREFERRED TYPES Preferred types are E -T-A products, w hich are m ost frequently used by our custom ers. W e m anufacture these preferred types in substantial quantities. You can /f_ind an overview of our preferred types here (Page 3). TYPICAL APPLICATIONS COMPLIANCE Automation technology, boats & vehicles, motor vehicles, utility vehi- cles, rail vehicles WEB LINKS Further information, International approvals, Technical basics, REACH , RoHS , Contact global.e-t-a.com 1225

CONVENTIONAL POWER DISTRIBUTION SYSTEMS Power board modules GENERAL INFORMATION SAFETY AND INSTALLATION INSTRUCTIONS

  • The circuit breakers must only be plugged in or removed in the OFF condition!
  • The m ax. supply current of the individual printed circuit boards m ust be observed w hen looping through several distribution modules!
  • The LEDs and the signalling require a mass potential (0 V), max. 2 A connected via spring-loaded terminals up to 2.5 mm² (1.5 m m ² w ith w ire end ferrule w ith plastic collar), a second term inal allow s looping through.
  • O ther population versions or voltage ratings are available upon request.
  • C ircuit breakers are not included in the scope of delivery. TECHNICAL DATA ELECTRICAL DATA Rated voltage Un 12 V DC, 24 V DC MECHANICAL DATA Mounting dimensions (WxHxD) 121 x 92.3 x 66.2 bis 94 mm (l x w x h) SUPPLY Total current per supply Max. 75 A Terminals / Cable cross section Spring-loaded terminals up to 16 mm2 (10 mm2 w ith w ire end ferrule w ith plastic collar), a second term inal enables further looping LOADS Rated current per load channel Max. 25 A Terminals / Cable cross section 5 channels per channel 3 terminals Spring-loaded terminals up to 6 mm2 (Spring-loaded terminals up to 4 mm2for w ire end ferrule w ith plastic collar) GROUP SIGNALLING Parallel connection Changeover contact 0.5 A (12 V DC / 24 V DC) Spring-loaded terminal up to 2.5 mm2 (Spring-loaded terminals 1.5 mm2 for w ire end ferrule w ith plastic collar) AMBIENT CONDITIONS Ambient temperature -20...+70 °C (PCB protected against condensation by surface coating) ORDERING NUMBER CODE P B M V A

1 TYPE NUMBER

PBM Power distribution system

2 DEVICE TYPE

1170 Thermal circuit breaker

3 VERSION, MAX. NUMBER OF CIRCUIT PROTECTORS ON THE DISTRIBUTION SYSTEM

05 Number of slots

4 VERSION

global.e-t-a.com 1225

CONVENTIONAL POWER DISTRIBUTION SYSTEMS Power board modules

5 SIGNALLING

A Version A w ith signalling, red LE D, 24 V DC B Version B w ith signalling, green and red LE D, 24 V DC C Version C without signalling, without LED, 12 V DC / 24 V DC D Version D w ith signalling, green and red LE D, 12 V DC Looking for a customer-specific version you cannot /f_ind in our ordering number code? Please get in touch with us. C ircuit protectors are not included in the delivery scope. PREFERRED TYPES Preferred types Short description PBM-1170-05-V0060-B W ith signalling (relay). W ith green and red LE D 24 V DC PBM-1170-05-V0060-D W ith signalling (relay). W ith green and red LE D 12 V DC TIME-/CURRENT CHARACTERISTICS DERATING TABLE Rated current In [A] Max. load current at 100 % ED [A] - Ambient Ta = 60 °C Ta = 70 °C Supply Rated current In [A] 75 A 60 A 50 A Load output Rated current In [A] 25 A 18.5 A 16 A DIMENSIONS DIMENSIONS global.e-t-a.com 1225

CONVENTIONAL POWER DISTRIBUTION SYSTEMS Power board modules SCHEMATIC DIAGRAMS SCHEMATIC DIAGRAM FURTHER PRODUCTS

RELATED PRODUCTS

1170 Compact single pole thermal circuit breaker with colour coded manual re-

lease. Independent trip-free and snap action m echanism s ensure a reliable switching behaviour. Plug-in type for standard automotive fuse blocks. The 1176 device version is specifically designed for the automotive sector (rated currents correspond to those of the /f_lat fuse series).

1180 Miniaturised single pole thermal circuit breaker with switching function optio-

nal (push-push actuation). Independent trip-free and snap action m echanis- ms ensure a reliable switching behaviour. Corresponds to the EN 60934 (IEC 60934) standard: S-type, TO. Can be plugged into fuse terminal blocks for DIN rail mounting. 1610-21 Single pole thermal automotive circuit breaker in a miniaturised design, co- lour coded housing caps or m anual release buttons are optionally available. A lso available w ith autom atic reset for 12 V. In the term inal area optionally with blade fuse inserts according to DIN 72581 part 3. 1610-92 Single pole thermal automotive circuit breaker in a miniaturised design, co- lour coded housing caps or m anual release buttons are optionally available. A lso available w ith autom atic reset for 12 V. In the term inal area optionally with blade fuse inserts according to DIN 72581 part 3. 1610-H2 Single pole thermal automotive circuit breaker in a miniaturised design, co- lour coded housing caps or m anual release buttons are optionally available. A lso available w ith autom atic reset for 12 V. In the term inal area optionally with blade fuse inserts according to DIN 72581 part 3. global.e-t-a.com 1225

CONVENTIONAL POWER DISTRIBUTION SYSTEMS Power board modules All information and data given on our products are accurate and reliable to the best of our knowledge, but E-T-A does not accept any responsibility for the use in applications which are not in accordance with the present specification. E-T-A reserves the right to change specifications at any time in the interest of technical improvement. Dimensions are subject to change without notice. Please enquire for the latest dimensional drawing with tolerances if required. All dimensions, data, pictures and descriptions are for information only and are not binding. Amendments, errors and omissions excepted. Ordering part numbers may differ from the device marking. global.e-t-a.com 1225