PBH POWERDYNAMICS | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 2
Technical content
Specifications subject to change without notice. Dimensions (mm). See Appendix A for recommended power cord. See PDI full line catalog for detailed specifications on power cords. 16/20A HIGH CURRENT, SNAP-IN/FLANGE MOUNT FILTER WITH IEC 60320 AC INLET SOCKET. PBH Series MECHANICAL DIMENSIONS
FEATURES
The PBH series offers filters for application that have high current (16/20A) requirements. The filters are available with different configurations of components and termination styles. These filters are available in flange mount and snap-in type. The medical grade filters offer excellent performance with maximum leakage current of 2µA at 120VAC, 60Hz. A ground choke can be added to enhance the grounding ability of the circuit. A bleeder resistor can also be added to prevent excessive voltages from developing across the filter capacitors when there is no load.
APPLICATIONS
Computer & networking equipment, Measuring & control equipment, Data processing equipment, laboratory instruments, Switching power supplies, other electronic equipment. TECHNICAL DATA
- Rated Voltage: 115/250VAC
- Rated Current: 16A, 20A
- Power Line Frequency: 50/60Hz
- Max. Leakage Current each Line to Ground: @ 115VAC 60Hz: 0.25mA @ 250VAC 50Hz: 0.50mA @ 115VAC 60Hz: 2 µA* @ 250VAC 50Hz: 5µA*
- Hipot Rating (one minute) Line to Ground: 2250VDC Line to Line: 1450VDC
- Temperature Range: -25C to +85C (Unit: mm) SEMKO, VDE approved to 16A * Medical application 52.8 42.0 30.1 CASE F CASE U CASE O 42.0 35.0 R3 TYP.27.0 2x 3.5 6.35 (79.5) 67.4 34.0 0.8 3.6 38.0 30.0 27.0 36.0 R3 TYP. SUGGESTED PANEL CUTOUT (MOUNTING FROM FRONT) THICKNESS OF PANEL IS FROM 1.00mm to 1.6mm 6.35 (79.5) 67.4 34.0 0.8 26.0 3.8 27.6 30.0 43.0 52.0 2x 6#32 RECOMMENDED PANEL CUTOUT (MOUNTING FROM REAR) R3.0 43.0+----0.1 34.5+0.5 10.0+----0.1 2x 3.5 6.35 79.5 75.7 0.8
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com • www.powerdynamics.com
CURRENT RATING (A): = 16 = 20 TERMINAL: = Q = S = W PBH OPTIONS: = 00 = 60 = 80 = 90 QUICK CONNECT SOLDER WIRE - - NO BLEEDER RESISTOR & NO GROUND CHOKE BLEEDER RESISTOR (1W, 1M) BLEEDER RESISTOR (1W, 1M) & GROUND CHOKE GROUND CHOKE (100µH) COMPONENT LOCATIONS: = 1 = 2 = 3 = 1M = 2M STANDARD TYPE WITHOUT C(X); C(Y) ONLY C(X) & C(Y) BEHIND L WITHOUT C(Y); C(X) ONLY WITHOUT C(Y); C(X) BEHIND L PBH Series Example & Ordering Code 6.3/0.25 4.0/0.187 UL 1015, 18AWG STRANDED, 4”
20 Q 60 1 C
8.0 3.0-3.6L 6.6 2.0-3.0L CASE CODE: = F = U = O FLANGE MOUNT SNAP-IN TABS - SIDE REAR PANEL MOUNT U Contact PDI for attenuation numbers ATTENUATION CODE TABLE: Case Code Cap. Cx (µF) 16/20A (mH) F,O,U 0.1 0.5 F,O,U 0.33 0.5 Medical applications,select Attenuation code with corresponding component values from the table. Non-Medical applications,select Attenuation code with corresponding component values from the table. Case Code Cap. Cx (µF) Cap. Cy (pF) 20A (mH) F,O,U 0.1 2200 0.5 F,O,U 0.1 3300 0.5 F,O,U 0.33 2200 0.5 = A = B = C = M1 = M2 Attenuation Comm. Mode(L-G) in MHz Diff. Mode(L-L) in MHz Code .15 .5 1 5 10 30 .15 .5 1 5 10 30 A 17 22 26 43 51 43 8 18 24 45 43 35 B 17 23 28 47 57 45 8 18 23 51 54 34 C 17 22 26 43 51 43 18 28 33 46 53 35 Attenuation Comm. Mode(L-G) in MHz Diff. Mode(L-L) in MHz Code .15 .5 1 5 10 30 .15 .5 1 5 10 30 M1 16 21 22 24 25 20 8 18 25 42 43 30 M2 16 20 22 24 25 20 17 28 33 41 40 31 O This table applies to schematic 1 only. Visit our website or contact PDI for other schematic attenuation numbers. "This table applies to schematic 1M only. Visit our website or contact PDI for other schematic attenuation numbers. Medical ApplicationsNon-Medical Applications O " Insertion loss in dB (50 Ohm circuit) Insertion loss in dB (50 Ohm circuit) SCHEMATICS CX G LINE LOAD L mH L mH Cy L N L Lg Cy R G LINE LOAD L mH L mH Cy L N L Lg Cy R G LINE LOAD L mH L mH L N L Lg R Cy Cy CX MEDICAL SCHEMATICS CX G LINE LOAD L mH L mH L N L Lg R G'G LINE LOAD L mH L mH L N L Lg R CX e-mail: filtersales@powerdynamics.com • www.powerdynamics.com