PBA600F RSG | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 2

Technical content

MODEL PBA600F-3R3 PBA600F-5 PBA600F-7R5 PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48 MAX OUTPUT WATTAGE[W] 396 600 600 636 645 648 648 624 DC OUTPUT ACIN 100V 3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27A 36V 18A 48V 13A ACIN 200V *3 3.3V 120A 5V 120A 7.5V 80A 12V 53A 15V 43A 24V 27 (31)A 36V 18A 48V 13A SPECIFICATIONS MODEL PBA600F-3R3 PBA600F-5 PBA600F-7R5 PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 PBA600F-48 INPUT VOLTAGE[V] AC85 - 264 1 for DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *5) CURRENT[A] ACIN 100V 5.8typ 8.2typ ACIN 200V 3typ 4.1typ FREQUENCY[Hz] 50/60 (4 7-6 3) EFFICIENCY[%] ACIN 100V 70typ 75typ 76typ 79typ 79typ 81typ 82typ 81typ ACIN 200V 72typ 77typ 79typ 82typ 82typ 84typ 84typ 83typ POWER FACTOR ACIN 100V 0.98typ (Io=100%) ACIN 200V 0.95typ (Io=100%) INRUSH CURRENT[A] ACIN 100V 20/40typ (Io=100%)( Primary inrush current /Secondary inrush current )( More than 3 sec. to re-start ) ACIN 200V 40/40typ (Io=100%)( Primary inrush current /Secondary inrush current )( More than 3 sec. to re-start ) LEAKAGE CURRENT[mA] 0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN) OUTPUT VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48 CURRENT[A] ACIN 100V 120 120 80 53 43 27 18 13 ACIN 200V *3 120 120 80 53 43 27 (31) 18 13 LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max LOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max RIPPLE[mVp-p] 0t o+ 5 0C*1 80max 80max 120max 120max 120max 120max 150max 150max - 2 0-0C*1 140max 140max 160max 160max 160max 160max 160max 400max RIPPLE NOISE[mVp-p] 0t o+ 5 0C*1 120max 120max 150max 150max 150max 150max 200max 200max - 2 0-0C*1 160max 160max 180max 180max 180max 180max 240max 500max TEMPERATURE REGULATION[mV] 0t o+ 5 0C*1 40max 50max 75max 120max 150max 240max 360max 480max - 2 0t o+ 5 0C*1 60max 75max 120max 180max 180max 290max 440max 600max DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192max START-UP TIME[ms] 400typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage. HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically OPERATING INDICATION LED (Green) REMOTE SENSING Provided REMOTE ON/OFF Provided ISOLATION INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 10mA , DC500V 50MWmin (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA , DC500V 50MWmin (At Room Temperature) OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA , DC500V 50MWmin (At Room Temperature) OUTPUT-RC-AUX AC100V 1minute, Cutoff current = 100mA , DC100V 50MWmin (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X , Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC Part15 classB , VCCI-B, CISPR22-B, EN55011-B, EN55022-B CE MARKING Low Voltage Directive, EMC Directive HARMONIC ATTENUATOR Complies with IEC61000-3-2 OTHERS CASE SIZE/WEIGHT 120X61X190mm (without terminal block and screw )( WXHXD) /1.6kg max COOLING METHOD Forced cooling (internal fan) *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail. *4 Overvoltage protection circuit to follow to output voltage setting. *5 Derating is required.Consult us for details. * A sound may occur from power supply at pulse loading. PBA600F Unit type PB A 600 F -5 - O

Ordering information

C :with Coating G :Low leakage current U :Operation stop voltage is set at a lower value F1 :With Long-Life fan F3 :Reverse air exhaust type F4 :Low speed fan R 123456 PB A-20 Recommended Noise Filter NAC-16-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series *The Noise Filter is recommended *to connect with several devices. Refer to instruction manual 7.1. Distribution: RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de Änderungen vorbehalten / subject to change without notice

(N) (L) AC FG AC LED CN3 CN1 CN2 AC(N) AC(L) M4 Input terminal cover 4-M4 Mounting Hole (Bottom sides) Output voltage adjustable potentiometer Output terminal(+) Output terminal(-) AIR FLOW 8-M4 Mounting Hole (Both sides) Name plate Name plate Output terminal cover ¶ Tolerance : ±1 ¶ Mass : 1.6kg or less ¶ PCB Material/thickness : FR-4 / 1.6mm ¶ Chassis material : Aluminum ¶ Dimensions in mm ¶ Mounting torque : 1.2N · m(12.8kgf·cm)max ¶ Screw tighting torque : M4 1.6N • m(16.9kgf • cm)max M5 2.5N • m(24.5kgf • cm)max ¶ The housing for the remote sensing unused is mounted on CN1 ¶1 F1(Optional):190.5 (13.8) (18) 190 6max ¶1(F1:190.5) 61 120 24 150±0.5 24 150±0.5 12.5 38±0.5 25max 20max 8.7 (6)7 1414 27.5 (52.5) (48.5) (92.5) 100 ±0.5 FG( ) ¶ Please conect earth to FG terminal on the unit. PB A-21 PBA600F Block diagram 250V15A INRUSH CURRENT LIMIT RECTIFIER DC OUT RC(REMOTE ON / OFF) VB(VOLTAGE BALANCE) CB(CURRENT BALANCE) PG(POWER GOOD) AUX(12V 0.1A) ±M(MONITOR) ±S(REMOTE SENSING) NOISE FILTER SWITCHING DEVICE CONTROL RECTIFIER AND FILTER RECTIFIER AND FILTER VOLTAGE SENSING ACTIVE FILTER VOLTAGE SENSING CURRENT SENSING INVERTER CONTROL ALARMFANINTERNAL REGURATOR CONTROL MASTER SLAVE CONTROL THERMAL PROTECTION CURRENT SENSING AC IN FG FUSE 85 - 264V OVER VOLTAGE PROTECTION External view Distribution: RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de Änderungen vorbehalten / subject to change without notice