MODEL PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48 MAX OUTPUT WATTAGE[W] 198 300 300 324 330 336 324 336 DC OUTPUT ACIN 100V 3.3V 60A 5V 60A 7.5V 40A 12V 27A 15V 22A 24V 14A 36V 9A 48V 7A ACIN 200V *3 3.3V 60A 5V 60A 7.5V 40A 12V 27A 15V 22A 24V 14(16.5)A 36V 9A 48V 7A SPECIFICATIONS MODEL PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48 INPUT VOLTAGE[V] AC85 - 264 1 for DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *4) CURRENT[A] ACIN 100V 3typ 4.1typ ACIN 200V 1.6typ 2typ FREQUENCY[Hz] 50/60 (4 7-6 3) EFFICIENCY[%] ACIN 100V 68typ 74typ 76typ 78typ 78typ 79typ 81typ 79typ ACIN 200V 71typ 77typ 79typ 81typ 81typ 82typ 84typ 82typ POWER FACTOR ACIN 100V 0.98typ (Io=100%) ACIN 200V 0.95typ (Io=100%) INRUSH CURRENT[A] ACIN 100V 20/40typ (Io=100%)( Primary inrush current /Secondary inrush current )( More then 3 sec. to re-start ) ACIN 200V 40/40typ (Io=100%)( Primary inrush current /Secondary inrush current )( More then 3 sec. to re-start ) LEAKAGE CURRENT[mA] 0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN) OUTPUT VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48 CURRENT[A] ACIN 100V 60 60 40 27 22 14 9 7 ACIN 200V *3 60 60 40 27 22 14 (16.5) 97 LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max LOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max RIPPLE[mVp-p] 0t o+ 5 0C*1 80max 80max 120max 120max 120max 120max 150max 150max - 2 0-0C*1 140max 140max 160max 160max 160max 160max 160max 400max RIPPLE NOISE[mVp-p] 0t o+ 5 0C*1 120max 120max 150max 150max 150max 150max 200max 200max - 2 0-0C*1 160max 160max 180max 180max 180max 180max 240max 500max TEMPERATURE REGULATION[mV] 0t o+ 5 0C*1 40max 50max 75max 120max 150max 240max 360max 480max - 2 0t o+ 5 0C*1 60max 75max 120max 180max 180max 290max 440max 600max DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192max START-UP TIME[ms] 300typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage. HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically OPERATING INDICATION LED (Green) REMOTE SENSING Provided REMOTE ON/OFF Provided ISOLATION INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 10mA , DC500V 50MWmin (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA , DC500V 50MWmin (At Room Temperature) OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA , DC500V 50MWmin (At Room Temperature) OUTPUT-RC-AUX AC100V 1minute, Cutoff current = 100mA , DC100V 50MWmin (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X , Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC Part15 classB , VCCI-B, CISPR22-B, EN55011-B, EN55022-B CE MARKING Low Voltage Directive, EMC Directive HARMONIC ATTENUATOR Complies with IEC61000-3-2 OTHERS CASE SIZE/WEIGHT 102X42X170mm (without terminal block and screw )( WXHXD) /1.0kg max COOLING METHOD Forced cooling (internal fan) *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail. *4 Derating is required.Consult us for details. * A sound may occur from power supply at pulse loading. PBA300F Unit type PB A 300 F -5 - O
Ordering information
C :with Coating G :Low leakage current U :Operation stop voltage is set at a lower value F3 :Reverse air exhaust type F4 :Low speed fan Refer to instruction manual 7.1. R 123456 PB A-18 Recommended Noise Filter NAC-06-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series *The Noise Filter is recommended *to connect with several devices. Distribution: RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de Änderungen vorbehalten / subject to change without notice
Output terminal(+) Output terminal(-) AC(N) AC(L) AIR FLOW ¶ Tolerance : ±1 ¶ Mass : 1.0kg or less ¶ PCB Material/thickness : FR-4 / 1.6mm ¶ Chassis material : Aluminum ¶ Dimensions in mm ¶ Mounting torque : 1.2N
- m max ¶ Screw fighting torque : 1.6N • m max ¶ The housing for the remote sensing unused is mounted on CN1 170 6max 50.5 102 (14) (15.5) 8.6 (23.5) 25max (87) (30) 28.5 64±0.5 (6)10 7 (50)12 1220±0.5 54 74±0.5 (75)12 H V.ADJ ¶ Please conect earth to FG terminal on the unit. FG( ) Mounting Hole (Bottom sides) PB A-19 PBA300F Block diagram 250V10A INRUSH CURRENT LIMIT RECTIFIER DC OUT RC(REMOTE ON / OFF) VB(VOLTAGE BALANCE) CB(CURRENT BALANCE) PG(POWER GOOD) AUX(12V 0.1A) ±M(MONITOR) ±S(REMOTE SENSING) NOISE FILTER SWITCHING DEVICE CONTROL RECTIFIER AND FILTER RECTIFIER AND FILTER VOLTAGE SENSING ACTIVE FILTER VOLTAGE SENSING CURRENT SENSING INVERTER CONTROL ALARMFANINTERNAL REGURATOR CONTROL MASTER SLAVE CONTROL THERMAL PROTECTION CURRENT SENSING AC IN FG FUSE 85 - 264V OVER VOLTAGE PROTECTION External view Distribution: RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de Änderungen vorbehalten / subject to change without notice