PBA150F TOTAL-POWER | Alldatasheet
Document overview
- Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
- PDF pages: 1
Technical content
Ordering information
R 1Series name
2 Output wattage
3 Universal input
4 Output voltage
5 Optional
C :with Coating G :Low leakage current (0.15mA max / ACIN 240V) E :Low leakage current and EMI class A (0.5mA max / ACIN 240V) T :Vertical terminal block J :Connector type R :with Remote ON/OFF N :with Cover (Only 24V UL508 is acquired) N1 :with DIN rail V :Output voltage setting potentiometer external- l y Specification is changed a t option. Please consult u s details. MODEL PBA150F-3R3 PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 PBA150F-24 PBA150F-36 PBA150F-48 MAX OUTPUT WATTAGE[W] 99 150 150.3 156 150 156 154.8 158.4 SPECIFICATIONS MODEL PBA150F-3R3 PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15 PBA150F-24 PBA150F-36 PBA150F-48 VOLTAGE[V] AC85 - 264 1f or DC120 - 370 (AC50 or DC70 optionally available *4) CURRENT[A] ACIN 100V 1.3typ 2.0typ ACIN 200V 0.7typ 1.0typ FREQUENCY[Hz] 50/60 (47 - 63) ACIN 100V 80typ 83typ 82typ 83typ 84typ 85typ 85typ 85typ INPUT EFFICIENCY[%] ACIN 200V 82typ 86typ 85typ 86typ 87typ 88typ 88typ 88typ POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typ ACIN 200V 0.87typ 0.93typ ACIN 100V 20typ (Io=100%) (At cold start)INRUSH CURRENT[A] ACIN 200V 40typ (Io=100%) (At cold start) OUTPUT LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1) VOLTAGE[V] 3.3 5 9 12 15 24 36 48 CURRENT[A] 30 30 16.7 13 10 6.5 4.3 3.3 LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max LOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max RIPPLE[mVp-p] 0t o+ 5 0C *1 80max 80max 120max 120max 120max 120max 150max 150max -10 - 0C *1 140max 140max 160max 160max 160max 160max 200max 200max 0t o+ 5 0C *1 120max 120max 150max 150max 150max 150max 250max 250max RIPPLE NOISE[mVp-p] -10 - 0C *1 160max 160max 180max 180max 180max 180max 300max 300max TEMPERATURE REGULATION[mV] 0t o+ 5 0C 50max 50max 90max 120max 150max 240max 360max 480max -10 to +50C 60max 60max 120max 150max 180max 290max 450max 600max DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 144max 192max START -UP TIME[ms] 350typ(ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS ISOLATION REMOTE SENSING Optional (Only -3R3, -5 Option -K) REMOTE ON/OFF Optional (Required external power source) INPUT -OUTPUT -RC *3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) INPUT -FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room T emperature) OUTPUT-RC-FG *3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature) OPERATING TEMP .,HUMID.AND ALTITUDE -10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max ENVIRONMENT VIBRATION 19.6m/s2 (2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis AGENCY APPROVALS UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input) SAFETY AND CONDUCTED NOISE Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B NOISE REGULATIONS CE MARKING Low Voltage Directive, EMC Directive HARMONIC ATTENUATOR Complies with IEC61000-3-2 OTHERS CASE SIZE/WEIGHT 34X93X168mm (without terminal block) (WXHXD) / 560g max (without cover) COOLING METHOD Convection *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and FG. *4 Derating is required.Consult us for details. * Parallel operation with other model is not possible. * Derating is required when operated with cover. * A sound may occur from power supply at peak loading.