PBA1500F TOTAL-POWER | Alldatasheet

Document overview

  • Manufacturer or author: Provided By ALLDATASHEET.COM(FREE DATASHEET DOWNLOAD SITE)
  • PDF pages: 1

Technical content

MODEL PBA1500F-3R3 PBA1500F-5 PBA1500F-7R5 PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48 MAX OUTPUT WATTAGE[W] 990 1500 1500 1500 1500 1680 1692 1680 DC OUTPUT ACIN 100V 3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 65A 36V 42A 48V 32A ACIN 200V *3 3.3V 300A 5V 300A 7.5V 200A 12V 125A 15V 100A 24V 70 (105)A 36V 47 (70)A 48V 35A SPECIFICATIONS MODEL PBA1500F-3R3 PBA1500F-5 PBA1500F-7R5 PBA1500F-12 PBA1500F-15 PBA1500F-24 PBA1500F-36 PBA1500F-48 INPUT VOLTAGE[V] AC85 - 264 1 for DC120 - 370 CURRENT[A] ACIN 100V 15typ 19typ ACIN 200V 8typ 10typ FREQUENCY[Hz] 50/60 (4 7-6 3) EFFICIENCY[%] ACIN 100V 72typ 77typ 81typ 81typ 83typ 84typ 84typ 84typ ACIN 200V 75typ 81typ 83typ 84typ 86typ 87typ 87typ 87typ POWER FACTOR ACIN 100V 0.98typ (Io=100%) ACIN 200V 0.95typ (Io=100%) INRUSH CURRENT[A] ACIN 100V ACIN 200V LEAKAGE CURRENT[mA] 0.9/1.5max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1) OUTPUT VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48 CURRENT[A] ACIN 100V 300 300 200 125 100 65 42 32 ACIN 200V *3 300 300 200 125 100 70 (105) 47(70) 35 LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max LOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max RIPPLE[mVp-p] 0t o+ 5 0C*1 80max 80max 120max 120max 120max 120max 150max 150max - 2 0-0C*1 140max 140max 160max 160max 160max 160max 160max 400max RIPPLE NOISE[mVp-p] 0t o+ 5 0C*1 120max 120max 150max 150max 150max 150max 200max 200max - 2 0-0C*1 160max 160max 180max 180max 180max 180max 240max 500max TEMPERATURE REGULATION[mV] 0t o+ 5 0C*1 40max 50max 75max 120max 150max 240max 360max 480max -20 to +50C*1 60max 75max 120max 180max 180max 290max 440max 600max DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192max START-UP TIME[ms] 600typ(ACIN 100/200V, Io=100%) Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage. HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically OPERATING INDICATION LED (Green) REMOTE SENSING Provided REMOTE ON/OFF Provided ISOLATION INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 25mA , DC500V 50MWmin (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 25mA , DC500V 50MWmin (At Room Temperature) OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA , DC500V 50MWmin (At Room Temperature) OUTPUT-RC-AUX AC100V 1minute, Cutoff current = 100mA , DC100V 50MWmin (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max VIBRATION 19.6m/s2 (2G), 10 - 55Hz, 3minutes period, 60minutes each along X , Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input ) CONDUCTED NOISE Complies with FCC Part15 classB , VCCI-B, CISPR22-B, EN55011-B, EN55022-B, additional noise filter required for meeting class B. CE MARKING Low Voltage Directive, EMC Directive HARMONIC ATTENUATOR Complies with IEC61000-3-2 OTHERS CASE SIZE/WEIGHT 178X61X268mm (without terminal block and screw )( WXHXD) /3.4kg max COOLING METHOD Forced cooling (internal fan) 20/40typ (Io=100%)( Primary inrush current /Secondary inrush current )( More than 10 sec. to re-start ) 40/40typ (Io=100%)( Primary inrush current /Secondary inrush current )( More than 10 sec. to re-start ) *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Ripple and ripple noise is measured on measuring board with capacitor of 22mF within 150mm from the output terminal. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail. *4 Overvoltage protection circuit to follow to output voltage setting. * A sound may occur from power supply at pulse loading. PBA1500F Unit type PBA 1500 F -5 - O

Ordering information

C :with Coating G :Low leakage current U :Operation stop voltage is set at a lower value F1 :With Long-Life fan F3 :Reverse air exhaust type F4 :Low speed fan R 12345 PBA A-18