MODEL PBA100F-3R3 PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48 MAX OUTPUT WATTAGE[W] 66 100 94.5 102 105 108 100.8 100.8 SPECIFICATIONS MODEL PBA100F-3R3 PBA100F-5 PBA100F-9 PBA100F-12 PBA100F-15 PBA100F-24 PBA100F-36 PBA100F-48 INPUT VOLTAGE[V] AC85 - 264 1 for DC120 - 370 (AC50 or DC70 Please refer to the instruction manual 2.1 Input voltage *4) CURRENT[A] ACIN 100V 0.9typ 1.3typ ACIN 200V 0.5typ 0.7typ FREQUENCY[Hz] 50/60 (4 7-6 3) EFFICIENCY[%] ACIN 100V 77typ 82typ 80typ 81typ 83typ 84typ 84typ 84typ ACIN 200V 79typ 84typ 82typ 83typ 86typ 86typ 86typ 86typ POWER FACTOR(Io=100%) ACIN 100V 0.98typ 0.99typ ACIN 200V 0.87typ 0.93typ INRUSH CURRENT[A] ACIN 100V 20typ (Io=100%)( At cold start ) ACIN 200V 40typ (Io=100%)( At cold start ) LEAKAGE CURRENT[mA] 0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1,DENAN) OUTPUT VOLTAGE[V] 3.3 5 9 12 15 24 36 48 LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max LOAD REGULATION[mV] 40max 40max 100max 100max 120max 150max 240max 240max RIPPLE[mVp-p] 0t o+ 5 0C*1 80max 80max 120max 120max 120max 120max 150max 150max - 1 0-0C*1 140max 140max 160max 160max 160max 160max 200max 200max RIPPLE NOISE[mVp-p] 0t o+ 5 0C*1 120max 120max 150max 150max 150max 150max 250max 250max - 1 0-0C*1 160max 160max 180max 180max 180max 180max 300max 300max TEMPERATURE REGULATION[mV] 0t o+ 5 0C 50max 50max 90max 120max 150max 240max 360max 480max -10 to +50C 60max 60max 120max 150max 180max 290max 450max 600max DRIFT[mV] *2 20max 20max 36max 48max 60max 96max 144max 192max START-UP TIME[ms] 350typ(ACIN 100V, Io=100%) HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically OPERATING INDICATION LED (Green) REMOTE SENSING Optional (Only -3R3, -5 Option -K) REMOTE ON/OFF Optional (Required external power source ) ISOLATION INPUT-OUTPUT-RC *3 AC3,000V 1minute, Cutoff current = 10mA , DC500V 50MWmin (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA , DC500V 50MWmin (At Room Temperature) OUTPUT-RC-FG *3 AC500V 1minute, Cutoff current = 100mA , DC500V 50MWmin (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X , Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC Part15 classB , VCCI-B, CISPR22-B, EN55011-B, EN55022-B CE MARKING Low Voltage Directive, EMC Directive HARMONIC ATTENUATOR Complies with IEC61000-3-2 OTHERS CASE SIZE/WEIGHT 32X93X147mm (without terminal block)( WXHXD) / 440g max (without cover) COOLING METHOD Convection *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101). *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and FG. *4 Derating is required. * Parallel operation with other model is not possible. * Derating is required when operated with cover. * A sound may occur from power supply at peak loading. PBA100F Unit type PB A 100 F -5 - O
Ordering information
C :with Coating G :Low leakage current (0.15mA max / ACIN 240V) E :Low leakage current and EMI class A (0.5mA max / ACIN 240V) T :Vertical terminal block J :Connector type R :with Remote ON/OFF N :with Cover (Only 24V UL508 is acquired) N1 :with DIN rail V :Output voltage setting potentiometer external- ly R 123456 PB A-14 Recommended Noise Filter NAC-06-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series *The Noise Filter is recommended *to connect with several devices. Cover is optional Distribution: RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de Änderungen vorbehalten / subject to change without notice
A 3-M3 2-M3 AC(N) AC(L) Name plate 13±0.59.5 15112.5 ±0.5 (13.5) 124±0.5 33.5 (11) (20) (81) (23.5) (14) (10) 147 8.61018 PBA100F¶ Tolerance : ±1 ¶ Mass : 440g or less (without cover) ¶ PCB Material/thickness : CEM3 / 1.6mm ¶ Chassis material : Aluminum ¶ Dimensions in mm ¶ Mounting torque : 0.49N • m(5kgf • cm)max ¶ Mounting torque : M4:1.6N • m(16.9kgf • cm)max Point A Terminal cover Mounting hole Mounting hole Voltage adjust LED ¶ External size of option T,J,R,N,N1,V and K is different from standard model and refer to 7 Option of instruction manual for details. 0.53.5 CN4 Connector for Remote sensing (option : only -3R3, -5) CN3 Connector for Remote ON/OFF (option) Cover (option) FG( ) ¶ Please connect safety ground to FG terminal on the unit. 1 2 Pin No. Contents RC(+) RC(-) CN3 Option (Mfr : J.S.T.) Connector type Model B2B-XH-A Mating Connector (Terminal) XHP-2 BXH-001T-P0.6 or SXH-001T-P0.6 Barrier strip type PB A-15 PBA100F Block diagram FG DC OUT AC IN 85 - 264V RC E 250V3.15A INRUSH CURRENT LIMIT RECTIFIER AND FILTER CONTROL TRANSFORMER CONTROL OVER VOLTAGE PROTECTION NOISE FILTER RECTIFIER AND FILTER INVERTER FUSE RECTIFIER CURRENT SENSING BOOSTER INDUCTER INVERTER CONTROL CURRENT SENSING EXTERNAL SOURCE OPTION External view Distribution: RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de Änderungen vorbehalten / subject to change without notice