MODEL PBA1000F-3R3 PBA1000F-5 PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48 MAX OUTPUT WATTAGE[W] 660 1000 1005 1056 1050 1056 1044 1056 DC OUTPUT ACIN 100V 3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44A 36V 29A 48V 22A ACIN 200V *3 3.3V 200A 5V 200A 7.5V 134A 12V 88A 15V 70A 24V 44 (51)A 36V 29A 48V 22A SPECIFICATIONS MODEL PBA1000F-3R3 PBA1000F-5 PBA1000F-7R5 PBA1000F-12 PBA1000F-15 PBA1000F-24 PBA1000F-36 PBA1000F-48 INPUT VOLTAGE[V] AC85 - 264 1 for DC120 - 350 (AC50 or DC70 Please refer to the instruction manual 7. option *5) CURRENT[A] ACIN 100V 9typ 13typ ACIN 200V 5typ 7typ FREQUENCY[Hz] 50/60 (4 7-6 3) EFFICIENCY[%] ACIN 100V 74typ 79typ 80typ 82typ 82typ 84typ 84typ 84typ ACIN 200V 76typ 81typ 83typ 84typ 84typ 86typ 86typ 86typ POWER FACTOR ACIN 100V 0.98typ (Io=100%) ACIN 200V 0.95typ (Io=100%) INRUSH CURRENT[A] ACIN 100V 20/40typ (Io=100%)( Primary inrush current /Secondary inrush current )( More then 10 sec. to re-start ) ACIN 200V 40/40typ (Io=100%)( Primary inrush current /Secondary inrush current )( More then 10 sec. to re-start ) LEAKAGE CURRENT[mA] 0.5/1.0max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1, DENAN) OUTPUT VOLTAGE[V] 3.3 5 7.5 12 15 24 36 48 CURRENT[A] ACIN 100V 200 200 134 88 70 44 29 22 ACIN 200V *3 200 200 134 88 70 44(51) 29 22 LINE REGULATION[mV] 20max 20max 36max 48max 60max 96max 144max 192max LOAD REGULATION[mV] 40max 40max 60max 100max 120max 150max 150max 300max RIPPLE[mVp-p] 0t o+ 5 0C*1 80max 80max 120max 120max 120max 120max 150max 150max - 2 0-0C*1 140max 140max 160max 160max 160max 160max 160max 400max RIPPLE NOISE[mVp-p] 0t o+ 5 0C*1 120max 120max 150max 150max 150max 150max 200max 200max - 2 0-0C*1 160max 160max 180max 180max 180max 180max 240max 500max TEMPERATURE REGULATION[mV] 0t o+ 5 0C*1 40max 50max 75max 120max 150max 240max 360max 480max - 2 0t o+ 5 0C*1 60max 75max 120max 180max 180max 290max 440max 600max DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192max START-UP TIME[ms] 400typ(ACIN 100/200V, Io=100%) *Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage. HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%) PROTECTION CIRCUIT AND OTHERS OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically OPERATING INDICATION LED (Green) REMOTE SENSING Provided REMOTE ON/OFF Provided ISOLATION INPUT-OUTPUT-RC AC3,000V 1minute, Cutoff current = 25mA , DC500V 50MWmin (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 25mA , DC500V 50MWmin (At Room Temperature) OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA , DC500V 50MWmin (At Room Temperature) OUTPUT-RC-AUX AC100V 1minute, Cutoff current = 100mA , DC100V 50MWmin (At Room Temperature) ENVIRONMENT OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C(Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X , Y and Z axis IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axis SAFETY AND NOISE REGULATIONS AGENCY APPROVALS (At only AC input) UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN CONDUCTED NOISE Complies with FCC Part15 classB , VCCI-B, CISPR22-B, EN55011-B, EN55022-B CE MARKING Low Voltage Directive, EMC Directive HARMONIC ATTENUATOR Complies with IEC61000-3-2 OTHERS CASE SIZE/WEIGHT 150X61X240mm (without terminal block and screw )( WXHXD) /2.2kg max COOLING METHOD Forced cooling (internal fan) *1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :RM101). Ripple and ripple noise is measured on measuring board with capacitor of 22mF within 150mm from the output terminal. *2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail. *4 Overvoltage protection circuit to follow to output voltage setting. *5 Derating is required.Consult us for details. * A sound may occur from power supply at pulse loading. PBA1000F Unit type PB A 1000 F -5 -O
Ordering information
C :with Coating G :Low leakage current U :Operation stop voltage is set at a lower value F1 :With Long-Life fan F3 :Reverse air exhaust type F4 :Low speed fan R 123456 PB A-22 Recommended Noise Filter NAC-20-472 High voltage pulse noise type : NAP series Low leakage current type : NAM series *The Noise Filter is recommended *to connect with several devices. Refer to instruction manual 7.1. Distribution: RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de Änderungen vorbehalten / subject to change without notice
AC(N) AC(L) LED 8-M4 Mounting Hole (Both sides) Name plate Input terminal cover Output voltage adjustable potentiometer Output terminal(+) Output terminal(-) ¶ Tolerance : ±1 ¶ Mass : 2.2kg or less ¶ PCB Material/thickness : FR-4 / 1.6mm ¶ Chassis material : Aluminum ¶ Dimensions in mm ¶ Mounting torque : 1.2N
- m(12.8kgf • cm)max ¶ Screw tighting torque : 1.6N • m(16.9kgf • cm)max ¶ The housing for the remote sensing unused is mounted on CN1 AIR FLOW 2-M4 2-º9 Name plate AC (L) FG AC CN1 H (N) CN3 CN2 V.ADJ Mounting Hole (Bottom sides) 4-M4 (18) 15.85 51.25 (25) 240 6max 150 25max (35) (7.5)13 9 29 165±0.5 11.5 38±0.5 104.75(24) 110±0.5 29 165 ±0.5 2.5 FG( ) ¶ Please conect earth to FG terminal on the unit. PB A-23 PBA1000F Block diagram 250V30A INRUSH CURRENT LIMIT RECTIFIER DC OUT RC(REMOTE ON / OFF) VB(VOLTAGE BALANCE) CB(CURRENT BALANCE) PG(POWER GOOD) AUX(12V 0.1A) ±M(MONITOR) ±S(REMOTE SENSING) NOISE FILTER SWITCHING DEVICE CONTROL RECTIFIER AND FILTER RECTIFIER AND FILTER VOLTAGE SENSING ACTIVE FILTER VOLTAGE SENSING CURRENT SENSING INVERTER CONTROL ALARMFANINTERNAL REGURATOR CONTROL MASTER SLAVE CONTROL THERMAL PROTECTION CURRENT SENSING AC IN FG FUSE 85 - 264V OVER VOLTAGE PROTECTION External view Distribution: RSG Electronic Components GmbH ■ Sprendlinger Landstr. 115 ■ D-63069 Offenbach/Germany Tel. +49 69 984047-0 ■ Fax +49 69 984047-77 ■ info@rsg-electronic.de ■ www.rsg-electronic.de Änderungen vorbehalten / subject to change without notice