Doc. N o. PB314 Series Rev.J 29-9-15 PB314 Series 6 3 6 - 7 4 5 W A T T S B A T T E R Y C H A R G E R S Y S T E M
FEATURES
- 636 - 745W
- P SU for B attery B ackup
- D C U P S C onnectable
- C onstant Float Voltage & C urrent Lim it
- C ircuit B reaker & A larm R elays
- O ptional LVD - Low Volts B attery D isconnect
- O P ER ATIO N S & IN STA LLATIO N H A N D B O O K AVA ILA B LE SPECIFICATIO NS INPUT Input Voltage 85 -2 64Vac or 12 0-360Vdc Frequency: 47 to 63 Hz Input Current: 4.1A typical at 2 00Vac Inrush current: 40A typical cold start 2 00Vac Line regulation 60m V m axim um OUTPUT Output Voltage 13.8Vdc, 2 7 .6Vdc Output Pow er 636W - 7 45 W Output Current See Selection Table Efficiency 7 9% typical Load regulation 1% typical Ripple 160m Vp-p m ax Noise 180m Vp-p m ax PROTECTION Overvoltage shutdow n 16.2 to 19.8V latching Output short circuit Indefinite protection (Autoresetting) Battery charger short circuit Indefinite protection (Autoresetting) Load output protection Therm al - M agnetic Circuit Breaker Battery output protection Therm al - M agnetic Circuit Breaker. Isolation Input - Output: 3KVac 1 m in Input - Ground: 2 KVac 1 m in Output - Ground: 5 00Vac 1m in ENVIRONM ENT Operating tem perature -2 0°C to 7 1°C D erating from 5 0°C to 7 1°C to 5 0% pow er Hum idity 2 0-90% relative hum idity (non condensing) Cooling Forced cooling - internal fan D ISPLAYS AND ALARM S D C OK LED Green On = OK, Voltage-free changeover contact (32 V, 1A).Alarm on failure of AC/D C PSU and tripping of over tem perature lim it. AC OK LED Green On = OK, Voltage-free changeover contact (32 V, 1A). Alarm on m ains fail. Battery Ok LED Green On = OK, Voltage-free changeover contact(32 V, 1A). Alarm on battery low voltage or on opening of battery circuit breaker. Battery low alarm voltage -11.0Vdc Battery Low Voltage D isconnect Option LVD : Battery LVD disconnect 10.5 V Battery LVD reconnect 12 .0Vdc Voltage m eter 0 to 15 Vdc Load current m eter 0 to 100A Battery current m eter -100A to +100A scale. OPTIONAL FEATURES Battery Charge Lim it Option BCL: Specify battery charge current based on battery size. Battery LVD disconnect Option LVD : For 12 V and 2 4V m odels, not available in 48V m odels. STAND ARD S & APPROVALS C-Tick AS/NZS CISPR11 Group 1 Class A. Safety UL 6095 0 Class 1 EM C Em issions com ply w ith AS/NZ CISPR2 2 Class-B M ECHANICAL AC input socket IEC32 0 fused / on off sw itch Output term ination Hirose connector (-H version) Cage clam p term inals (-C version) Alarm relay contacts D B2 5 socket Load fault current proteciton breaker 63 A Battery fault current protection breaker 63 A Rack m ount size 2 64 L x 17 2 W x 67 H m m W eight 5 .0Kg
6 3 6 - 7 4 5 W A T T S B A T T E R Y C H A R G E R S Y S T E M M OD EL NUM BER OUTPUT VOLTAGE OUTPUT CURRENT BATTERY CHARGE CURRENT POW ER OUTPUT CONNECTOR PB314-12 -43-H 13.8Vdc 43A Balance of load current 645 W Hirose PB314-12 -43-C 13.8Vdc 43A Balance of load current 645 W Cage clam p PB314-12 -5 3-C 13.8Vdc 5 3A Balance of load current 636W Cage clam p PB314-12 -43-H 13.8Vdc 43A Balance of load current 645 W Hirose PB314-12 -5 3-C 13.8Vdc 5 3A Balance of load current 636W Cage clam p PB314-2 4-2 7 -H 2 7 .6Vdc 2 7 A Balance of load current 7 45 W Hirose PB314-2 4-2 7 -C 2 7 .6Vdc 2 7 A Balance of load current 7 45 W Cage clam p PB314-2 4-2 7 -H-LVD 2 7 .6Vdc 2 7 A Balance of load current 7 45 W Hirose PB314-2 4-2 7 -C-LVD 2 7 .6Vdc 2 7 A Balance of load current 7 45 W Cage clam p
Doc. N o. PB314 Series Rev.J 29-9-15 PB314 Series 6 3 6 - 7 4 5 W A T T S B A T T E R Y C H A R G E R S Y S T E M